Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray dark-field and phase-contrast imaging using a grating interferometer

In this letter, we report results obtained with a recently developed approach for grating-based x-ray dark-field imaging [F. Pfeiffer et al., Nat. Mater. 7, 134 (2008)]. Since the image contrast is formed through the mechanism of small-angle scattering, it provides complementary and otherwise inaccessible structural information about the specimen at the micron and submicron length scales. Our approach is fully compatible with conventional transmission radiography and the grating-based hard x-ray phase-contrast imaging scheme [F. Pfeiffer et al., Nat. Phys. 2, 258 (2006)]. Since it can be used with standard x-ray tube sources, we envisage widespread applications to x-ray medical imaging, industrial nondestructive testing, or security screening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Whole-cell phase contrast imaging at the nanoscale using Fresnel Coherent Diffractive Imaging Tomography

X-ray tomography can provide structural information of whole cells in close to their native state. Radiation-induced damage, however, imposes a practical limit to image resolution, and as such, a choice between damage, image contrast, and image resolution must be made. New coherent diffractive imaging techniques, such Fresnel Coherent Diffractive Imaging (FCDI), allows quantitative phase information with exceptional dose efficiency, high contrast, and nano-scale resolution. Here we present three-dimensional quantitative images of a whole eukaryotic cell by FCDI at a spatial resolution below 70 nm with sufficient phase contrast to distinguish major cellular components. From our data, we estimate that the minimum dose required for a similar resolution is close to that predicted by the Rose criterion, considerably below accepted estimates of the maximum dose a frozen-hydrated cell can tolerate. Based on the dose efficiency, contrast, and resolution achieved, we expect this technique will find immediate applications in tomographic cellular characterisation.

MICROSCOPY↗

Phase-contrast imaging using ultrafast x-rays in laser-shocked materials

High-energy x-rays, >10 keV, can be efficiently produced from ultrafast laser target interactions with many applications to dense target materials in inertial confinement fusion and high-energy density physics. These same x-rays can also be applied to measurements of low-density materials inside high-density Hohlraum environments. In the experiments presented, high-energy x-ray images of laser-shocked polystyrene are produced through phase contrast imaging. The plastic targets are nominally transparent to traditional x-ray absorption but show detailed features in regions of high density gradients due to refractive effects often called phase contrast imaging. The 200 TW Trident laser is used both to produce the x-ray source and to shock the polystyrene target. X-rays at 17 keV produced from 2 ps, 100 J laser interactions with a 12 {mu}m molybdenum wire are used to produce a small source size, required for optimizing refractive effects. Shocks are driven in the 1 mm thick polystyrene target using 2 ns, 250 J, 532 nm laser drive with phase plates. X-ray images of shocks compare well to one-dimensional hydro calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative hard x-ray phase contrast imaging of micropipes in SiC

Peculiarities of quantitative hard x-ray phase contrast imaging of micropipes in SiC are discussed. The micropipe is assumed as a hollow cylinder with an elliptical cross section. The major and minor diameters can be restored using the least square fitting procedure by comparing the experimental data, i.e. the profile across the micropipe axis, with those calculated based on phase contrast theory. It is shown that one projection image gives an information which does not allow a complete determination of the elliptical cross section, if an orientation of micropipe is not known. Another problem is a weak accuracy in estimating the diameters, partly because of using pink synchrotron radiation, which is necessary because a monochromatic beam intensity is not sufficient to reveal the weak contrast from a very small object. The general problems of accuracy in estimating the two diameters using the least square procedure are discussed. Two experimental examples are considered to demonstrate small as well as modest accuracies in estimating the diameters.

36 MATERIALS SCIENCE↗

Simultaneous X-ray diffraction and phase-contrast imaging for investigating material deformation mechanisms during high-rate loading

Using a high-speed camera and an intensified charge-coupled device (ICCD), a simultaneous X-ray imaging and diffraction technique has been developed for studying dynamic material behaviors during high-rate tensile loading. A Kolsky tension bar has been used to pull samples at 1000 s -1 and 5000 s -1 strain-rates for super-elastic equiatomic NiTi and 1100-O series aluminium, respectively. By altering the ICCD gating time, temporal resolutions of 100 ps and 3.37 µs have been achieved in capturing the diffraction patterns of interest, thus equating to single-pulse and 22-pulse X-ray exposure. Furthermore, the sample through-thickness deformation process has been simultaneously imaged via phase-contrast imaging. It is also shown that adequate signal-to-noise ratios are achieved for the detected white-beam diffraction patterns, thereby allowing sufficient information to perform quantitative data analysis diffraction via in-house software ( WBXRD_GUI ). Of current interest is the ability to evaluate crystal d -spacing, texture evolution and material phase transitions, all of which will be established from experiments performed at the aforementioned elevated strain-rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contact and Phase-Contrast Imaging of Nanostructures by Femtosecond-Laser-Driven-Cluster-Based Debris-Free Soft X-Ray Source

The high-intensive source of soft X-ray emission was developed by femtosecond laser pulses irradiation of submicron size CO{sub 2} clusters, produced in custom designed super-sonic nozzle while mixing the 10% CO{sub 2}+90% He expanding gases. The LiF crystal soft X-ray detectors have been used for obtaining absorption images of ultrathin (nanoscale) foils and biological structures illuminated by the developed source. It was demonstrated that even if the foil is essentially transparent for the soft X-ray radiation (like 100 nm thick Zr foil), the image contrast could be significantly increased due to the influence of propagation-based phase-contrast effect, by placing the detector at the proper distance from the sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamic compaction of nickel powder examined by x-ray phase contrast imaging

Understanding the shock response of porous, granular materials is important for many scientific applications. In this work, a propagation-based x-ray phase contrast imaging technique was used to examine the shock compaction response of Ni powder (particle size: 30 and 45 µm), encapsulated in PMMA cylinders, in situ and in real time. The propagating shock wave in the PMMA cylinder and the deformation of the Ni powder column were recorded, but the compaction wave in the Ni powder could not be observed due to insufficient penetration of x-ray photons through the sample. The overall shape of the deformed Ni column downstream of the PMMA shock looked qualitatively similar for both particle sizes: it deformed inward and then outward similar to a converging-diverging nozzle, followed by a ‘mushroom’-like structure at the impact face. A preliminary analysis of our data using shock-polar method provided insight into the observed shock and flow deflection angles at the PMMA/Ni interface, and permitted evaluation of the Ni powder EOS used in this work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast, high resolution, phase contrast imaging of impact response with synchrotron radiation

Understanding the dynamic response of materials at extreme conditions requires diagnostics that can provide real-time, in situ, spatially resolved measurements on the nanosecond timescale. The development of methods such as phase contrast imaging (PCI) typically used at synchrotron sources offer unique opportunities to examine dynamic material response. In this work, we report ultrafast, high-resolution, dynamic PCI measurements of shock compressed materials with 3 {mu}m spatial resolution using a single 60 ps synchrotron X-ray bunch. These results firmly establish the use of PCI to examine dynamic phenomena at ns to {mu}s timescales.

36 MATERIALS SCIENCE↗

Thermodynamics of Bose-Einstein-condensed clouds using phase-contrast imaging

Phase contrast imaging is used to observe Bose-Einstein condensates at finite temperature in situ. The imaging technique is used to accurately derive the absolute phase shift of a probe laser beam due to both the condensate and the thermal cloud. The accuracy of the method is enhanced by using the periodicity of the intensity signal as a function of the accumulated phase. The measured density profiles can be described using a two-relevant-parameter fit, in which only the chemical potential and the temperature are to be determined. This allows us to directly compare the measured density profiles to different mean-field models in which the interaction between the condensed and the thermal atoms is taken into account to various degrees.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images

Purpose: To develop and validate an automated technique for measuring image contrast in chest computed tomography (CT) exams. Methods: An automated computer algorithm was developed to measure the distribution of Hounsfield units (HUs) inside four major organs: the lungs, liver, aorta, and bones. These organs were first segmented or identified using computer vision and image processing techniques. Regions of interest (ROIs) were automatically placed inside the lungs, liver, and aorta and histograms of the HUs inside the ROIs were constructed. The mean and standard deviation of each histogram were computed for each CT dataset. Comparison of the mean and standard deviation of the HUs in the different organs provides different contrast values. The ROI for the bones is simply the segmentation mask of the bones. Since the histogram for bones does not follow a Gaussian distribution, the 25th and 75th percentile were computed instead of the mean. The sensitivity and accuracy of the algorithm was investigated by comparing the automated measurements with manual measurements. Fifteen contrast enhanced and fifteen non-contrast enhanced chest CT clinical datasets were examined in the validation procedure. Results: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast enhanced chest CT exams. The automated measurements were in agreement with manual measurements. The algorithm has sufficient sensitivity as indicated by the near unity slope of the automated versus manual measurement plots. Furthermore, the algorithm has sufficient accuracy as indicated by the high coefficient of determination, R2, values ranging from 0.879 to 0.998. Conclusion: Patient-specific image contrast can be measured from clinical datasets. The algorithm can be run on both contrast enhanced and non-enhanced clinical datasets. The method can be applied to automatically assess the contrast characteristics of clinical chest CT images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

Validation of full-wave simulations for mode conversion of waves in the ion cyclotron range of frequencies with phase contrast imaging in Alcator C-Mod

Mode conversion of fast waves in the ion cyclotron range of frequencies (ICRF) is known to result in current drive and flow drive under optimised conditions, which may be utilized to control plasma profiles and improve fusion plasma performance. To describe these processes accurately in a realistic toroidal geometry, numerical simulations are essential. Quantitative comparison of these simulations and the actual experimental measurements is important to validate their predictions and to evaluate their limitations. The phase contrast imaging (PCI) diagnostic has been used to directly detect the ICRF waves in the Alcator C-Mod tokamak. The measurements have been compared with full-wave simulations through a synthetic diagnostic technique. Recently, the frequency response of the PCI detector array on Alcator C-Mod was recalibrated, which greatly improved the comparison between the measurements and the simulations. In this study, mode converted waves for D-{sup 3}He and D-H plasmas with various ion species compositions were re-analyzed with the new calibration. For the minority heating cases, self-consistent electric fields and a minority ion distribution function were simulated by iterating a full-wave code and a Fokker-Planck code. The simulated mode converted wave intensity was in quite reasonable agreement with the measurements close to the antenna, but discrepancies remain for comparison at larger distances.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study on the effect of nozzle hole-to-hole angle on the near-field spray of diesel injector using fast X-ray phase-contrast imaging

Fuel atomization and vaporization process play a critical role in determining the engine combustion and emission. The primary near-nozzle breakup is the vital link between the fuel emerging from the nozzle and the fully atomized spray. In this study, the near-nozzle spray characteristics of diesel injector with different umbrella angle (UA) were investigated using high-speed X-ray phase-contrast imaging and quantitative image processing. A classic ‘dumbbell’ profile of spray width (SW) composed of three stages: opening stage, semisteady stage and closing stage. The SW peak of two-hole injectors was more than twice of that of single-hole injector at the opening and closing stages, corresponding to the hollow-cone spray. This indicated the vortex flow was formed with the increase of the UA. The higher injection pressure had little influence on the SW while led to earlier breakup closer to the nozzle. Significant fuel effect on the SW at higher needle lift was found. However, this effect could be neglect at lower needle lift due to the leading role of internal flow and cavitation on the near-field spray characteristics. In addition, the morphology-based breakup process was observed, which highlighted the important effect of internal flow on the spray development. The possibility of using hollow-cone spray in diesel injector was also discussed.

biodiesel↗

Calculation of integrated intensities in aberration-corrected Z-contrast images

Inclusion of spatial incoherence has been shown to give quantitative agreement between non-aberration-corrected high-angle annular dark-field scanning transmission electron microscopy images and theoretical simulations. Here we show that, using the same approach, a significant improvement in the correlation between calculated and experimental normalized integrated intensities is obtained in the InAsP ternary semiconductor alloy, but residual discrepancies remain. We have demonstrated, in good agreement with experimental intensities obtained in calibrated samples, that normalized integrated intensities show a low dependence on the sample thickness over a wide range of thickness values. This behaviour does not occur in conventional (non-aberration-corrected) images and constitutes a powerful tool for straightforward interpretation of high-resolution images in terms of atomic column-resolved compositional maps.

36 MATERIALS SCIENCE↗