Search NASA⌕ Search

SEARCH · Search NASA

Results for “coolant injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

System Study: High-Pressure Coolant Injection 1998–2013

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: High-Pressure Coolant Injection 1998-2012

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: High-Pressure Coolant Injection 1998-2020

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hour, and failure data from 1998–2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

99 GENERAL AND MISCELLANEOUS↗

System Study: High-Pressure Coolant Injection 1998-2014

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: High-Pressure Coolant Injection 1998-2022

This report presents an unreliability evaluation of the high-pressure coolant injection (HPCI) system at 22 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

99 GENERAL AND MISCELLANEOUS↗

System Study: High-Pressure Coolant Injection 1998-2024

This report presents an unreliability evaluation of the high-pressure coolant injection (HPCI) system at 22 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: High-Pressure Coolant Injection 1998–2018

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hours, and failure data from 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

99 GENERAL AND MISCELLANEOUS↗

Development of a Large-Scale Open Geometry for Squealer Tip Coolant Injection Research

In this work, a large-scale symmetric canonical axial turbine squealer tip model is developed, which allows for the investigation of incoming gas path flow interaction with coolant flow injected into the squealer cavity. The model is developed to investigate Reynolds numbers on the order of one million for their applicability to novel supercritical CO2 cycles.

Tuite, Logan M.↗

Laser Intertial Fusion Energy: Neutronic Design Aspects of a Hybrid Fusion-Fission Nuclear Energy System

This study investigates the neutronics design aspects of a hybrid fusion-fission energy system called the Laser Fusion-Fission Hybrid (LFFH). A LFFH combines current Laser Inertial Confinement fusion technology with that of advanced fission reactor technology to produce a system that eliminates many of the negative aspects of pure fusion or pure fission systems. When examining the LFFH energy mission, a significant portion of the United States and world energy production could be supplied by LFFH plants. The LFFH engine described utilizes a central fusion chamber surrounded by multiple layers of multiplying and moderating media. These layers, or blankets, include coolant plenums, a beryllium (Be) multiplier layer, a fertile fission blanket and a graphite-pebble reflector. Each layer is separated by perforated oxide dispersion strengthened (ODS) ferritic steel walls. The central fusion chamber is surrounded by an ODS ferritic steel first wall. The first wall is coated with 250-500 μm of tungsten to mitigate x-ray damage. The first wall is cooled by Li 17 Pb 83 eutectic, chosen for its neutron multiplication and good heat transfer properties. The Li 17 Pb 83 flows in a jacket around the first wall to an extraction plenum. The main coolant injection plenum is immediately behind the Li 17 Pb 83 , separated from the Li 17 Pb 83 by a solid ODS wall. This main system coolant is the molten salt flibe (2LiF-BeF 2 ), chosen for beneficial neutronics and heat transfer properties. The use of flibe enables both fusion fuel production (tritium) and neutron moderation and multiplication for the fission blanket. A Be pebble (1 cm diameter) multiplier layer surrounds the coolant injection plenum and the coolant flows radially through perforated walls across the bed. Outside the Be layer, a fission fuel layer comprised of depleted uranium contained in Tristructural-isotropic (TRISO) fuel particles having a packing fraction of 20% in 2 cm diameter fuel pebbles. The fission blanket is cooled by the same radial flibe flow that travels through perforated ODS walls to the reflector blanket. This reflector blanket is 75 cm thick comprised of 2 cm diameter graphite pebbles cooled by flibe. The flibe extraction plenum surrounds the reflector bed. Detailed neutronics designs studies are performed to arrive at the described design. The LFFH engine thermal power is controlled using a technique of adjusting the 6 Li/ 7 Li enrichment in the primary and secondary coolants. The enrichment adjusts system thermal power in the design by increasing tritium production while reducing fission. To perform the simulations and design of the LFFH engine, a new software program named LFFH Nuclear Control (LNC) was developed in C++ to extend the functionality of existing neutron transport and depletion software programs. Neutron transport calculations are performed with MCNP5. Depletion calculations are performed using Monteburns 2.0, which utilizes ORIGEN 2.0 and MCNP5 to perform a burnup calculation. LNC supports many design parameters and is capable of performing a full 3D system simulation from initial startup to full burnup. It is able to iteratively search for coolant 6Li enrichments and resulting material compositions that meet user defined performance criteria. LNC is utilized throughout this study for time dependent simulation of the LFFH engine. Two additional methods were developed to improve the computation efficiency of LNC calculations. These methods, termed adaptive time stepping and adaptive mesh refinement were incorporated into a separate stand alone C++ library name the Adaptive Burnup Library (ABL). The ABL allows for other client codes to call and utilize its functionality. Adaptive time stepping is useful for automatically maximizing the size of the depletion time step while maintaining a desired level of accuracy. Adaptive meshing allows for analysis of fixed fuel configurations that would normally require a computationally burdensome number of depletion zones. Alternatively, Adaptive Mesh Refinement (AMR) adjusts the depletion zone size according to the variation in flux across the zone or fractional contribution to total absorption or fission. A parametric analysis on a fully mixed fuel core was performed using the LNC and ABL code suites. The resulting system parameters are found to optimize performance metrics using a 20 MT DU fuel load with a 20% TRISO packing and a 300 μm kernel radius operated with a fusion input power of 500 MW and a fission blanket gain of 4.0. LFFH potentially offers a proliferation resistant technology relative to other nuclear energy systems primarily because of no need for fuel enrichment or reprocessing. A figure of merit of the material attractiveness is examined and it is found that the fuel is effectively contaminated to an unattractive level shortly after the system is started due to fission product and minor actinide build up.

42 ENGINEERING↗

Probabilistic methods in a study of trip setpoints

Most early vintage Boiling Water Reactors have a high head and high capacity High Pressure Coolant Injection (HPCI) pump to keep the core covered following a loss of coolant accident (LOCA). However, the protection afforded by the HPCI pump for mitigating a LOCA introduces the potential that a spurious start of the HPCI pump could oversupply the reactor vessel and lead to an automatic trip of the main turbine due to high water level. A turbine trip and associated increase in moderator density could challenge the bases of fuel integrity operating limits. To prevent turbine trip during spurious operation of the HPCI pump, the reactor protection system includes instrumentation and logic to sense high water level and automatically trip the HPCI pump prior to reaching the turbine trip setpoint. This paper describes an analysis that was performed to determine if existing reactor vessel water level trip instrumentation, logic and setpoints result in a high probability that the HPCI pump will trip prior to actuation of the turbine trip. Using nominal values for the initial water level and for the HPCI pump and turbine trip setpoints, and using the probability distribution functions for measurement uncertainty in these setpoints, a Monte Carlo simulation was employed to determine probabilities of successfully tripping the HPCI pump prior to tripping of the turbine. The results of the analysis established that the existing setpoints, instrumentation and logic would be expected to reliably prevent a trip of the main turbine. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of F and B Operation Strategy with LPSI and H-SIT

In the current nuclear power plants (NPPs), most of the critical safety functions are provided by many active safety systems. However, in order to meet the futuristic goals of safety, relying on these active safety systems alone does not seem to be viable. As passive system has a strength on the mitigation of station black out accident and it also contributes to increase the diversity of mitigation way, application of passive system becomes a paramount in the nuclear industry to enhance the nuclear plant safety. Recently, many researches for developing passive systems and operation strategies have been carried out in the nuclear field. General passive systems and strategies, however, have a critical limitation, especially for passive injection systems. As these systems use gravity as their driving force, it is difficult to inject coolant in a passive way in a high-pressure condition thus depressurization has to be preferentially performed to do passive injection. The problem is that depressurization inevitably causes the loss of core inventory thus it is not preferred in order to secure plant safety. Hybrid safety injection tank (H-SIT) system was newly suggested a few years ago to passively inject the coolant into the reactor coolant system (RCS) without depressurization in a high-pressure condition. The H-SIT system is planned to be integrated into advanced power reactor plus (APR+). Generally, the H-SIT system can inject water using the pressure from nitrogen gas as a conventional safety-injection tank in low-pressure accidents, such as large and medium-break loss of coolant accidents (LOCA). Additionally, the H-SIT system can also inject water using gravitational force in high-pressure accidents. If a high pressure accident occurs, the pressure of each H-SIT is equalized with pressure of pressurizer through equalizing pipes, thus allowing the H-SITs to inject water by gravitational force. In the target plant, four H-SITs are planned to be installed. Each has a 2.5 in diameter equalizing pipe and it can be operated manually. Long-term cooling of core is an ultimate goal of all mitigation actions for plant safety and feed and bleed (F and B) operation strategy is one of the long-term cooling strategies in conventional pressurized water reactor (PWR). The important point of F and B operation is that injection for feed operation is performed by only high pressure safety injection (HPSI) pump because operation of low pressure safety injection (LPSI) pump needs the depressurization and it causes core dry out. As H-SIT is passively operated in an accident situation, it was originally designed for mitigation of station black out accident. Besides, operator can use the H-SIT system same as high pressure injection pump in any accident situations. Thus, function of high pressure injection by H-SIT can be used for feed operation when HPSI pumps fail. If it is possible, H-SIT can make up the core during depressurization then LPSI pumps can be used for F and B operation. In this study, F and B operation strategy with LPSI and HSIT is developed. This is a new concept for the long-term cooling operation. If this strategy is applied, low pressure injection pump can be successfully used for F and B operation thus operator has the additional mitigation way. As this strategy make plant safe even though HPSI and PAFS are both failed, it can effectively enhance the plant safety. For this strategy two RCGVSs and two POSRVs are needed as a depressurization system for bleed operation and only one LPSI is enough for feed operation. H-SIT operation is also needed to make up core inventory during bleed operation. For this operation, four H-SITs have to be used to make up core safely. Based on the risk analysis using PSA method, if this strategy is applied, core damage frequency is 1.868 e-6 which declined 7 percent from original model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improved Safety Injection Flow Map Associated with Target RCS Depressurization to Maintain Core Coolability of OPR1000

In Korea, Severe Accident Management Guidance (SAMG) for Optimized Power Reactor (OPR1000) has been developed through the research results related to the WOG SAMG, in which the operation phase shifts from the Emergency Operation Procedure (EOP) to the SAMG when the Core Exit Temperature (CET) reaches 923 K. Among 7 mitigation strategies envisioned, the third management strategy, injecting coolant into Reactor Coolant System (RCS) by depressurizing the RCS is one of the key strategies to fortify the in-vessel retention capability. As an aid to such mitigation strategy, a safety injection (SI) flow map has been developed by Lee et al. for predicting required flow rate associated with target RCS depressurization to recover in-vessel coolability. The mechanistic SI flow map used the CET increase rate and core water level decrease rate obtained from MELCOR code simulation. It should be noted that during the severe accident, the total heat generated is sum of the decay heat and the oxidation heat. Thus, it is necessary to consider additional heat sources by oxidation reaction between cladding, structure, control rod, and hot steam prior to the injection of coolant. It was believed that the SI model estimated required flow rate rather conservatively by considering the expected amount decay heat and the accumulated heat in the core based on the RCS pressure. However, it was confirmed that the SI model developed by Lee et al. could not represent the total heat removal especially since start of oxidation. Under transient conditions, the heat sources accumulated in the heat structures (fuel, cladding, supporting structures) should be embarked in the model for accurate contribution of the total heat source to the required flow rate. Therefore, the objective of this study is to improve the previous SI flow map predicting the injection flow rate associated with target RCS depressurization to satisfy the in-vessel coolability during severe accidents. Additional terms were developed to reflect accurate heat accumulating and included in the existing model. Resulting SI flow map includes the target RCS depressurization, which enables discharge of the required flow rate by utilizing the flow rate-pressure curve with operation of two high pressure safety injections (HPSIs). Also recent MELCOR simulation result of a postulated steam generator tube rupture (SGTR) accident verified the accuracy of the improved map.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Core Status of Fukushima Daiichi Nuclear Power Plant

There were some events and phenomena that occurred which have been deemed specific to the Fukushima Daiichi NPP. The primary issues were as follows: - Direct steam leakage from the reactor pressure vessels (RPVs) to the dry-wells through the gaskets of the safety relief valves and/or due to creep damage of the main steam line, and damage of the in-core monitor guide tubes due to buckling. - Direct corium leakage from the RPVs to the pedestal floors through the melt portions of the in-core monitor housings. - Alternative water injection by the fire trucks with large amount of leakages through the branch lines. - Partial load operation of the Reactor Core Isolation Cooling system and the High Pressure Coolant Injection system. - Gas leakage from the primary containment vessels to the reactor buildings due to over pressure than the design maximum value. - Thermal stratification in the suppression pool resulting in incomplete steam condensation in the pool. The accident progressions were analyzed with the newly developed physical models for the above issues. And also considering the qualitatively estimated core status based on the plant parameters measured after the accident, the current core status was assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary analysis of loss-of-coolant accident in Fukushima nuclear accident

Loss-of-Coolant Accident (LOCA) in Boiling Water Reactor (BWR) especially on Fukushima Nuclear Accident will be discussed in this paper. The Tohoku earthquake triggered the shutdown of nuclear power reactors at Fukushima Nuclear Power station. Though shutdown process has been completely performed, cooling process, at much smaller level than in normal operation, is needed to remove decay heat from the reactor core until the reactor reach cold-shutdown condition. If LOCA happen at this condition, it will cause the increase of reactor fuel and other core temperatures and can lead to reactor core meltdown and exposure of radioactive material to the environment such as in the Fukushima Dai Ichi nuclear accident case. In this study numerical simulation has been performed to calculate pressure composition, water level and temperature distribution on reactor during this accident. There are two coolant regulating system that operational on reactor unit 1 at this accident, Isolation Condensers (IC) system and Safety Relief Valves (SRV) system. Average mass flow of steam to the IC system in this event is 10 kg/s and could keep reactor core from uncovered about 3,2 hours and fully uncovered in 4,7 hours later. There are two coolant regulating system at operational on reactor unit 2, Reactor Core Isolation Condenser (RCIC) System and Safety Relief Valves (SRV). Average mass flow of coolant that correspond this event is 20 kg/s and could keep reactor core from uncovered about 73 hours and fully uncovered in 75 hours later. There are three coolant regulating system at operational on reactor unit 3, Reactor Core Isolation Condenser (RCIC) system, High Pressure Coolant Injection (HPCI) system and Safety Relief Valves (SRV). Average mass flow of water that correspond this event is 15 kg/s and could keep reactor core from uncovered about 37 hours and fully uncovered in 40 hours later.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Single Rod Reflood Quenching Experiments with Simulated Decay Heat for Accident-Tolerant Fuel Claddings

The Loss-of-Coolant Accident (LOCA) is a hypothetical situation which includes a sudden loss of coolant, overheating of fuel rods, and emergency coolant injection. This situation could be modeled as a quenching process of cladding material into the coolants, a reverse process of boiling the coolants. The KAERI have been developing a CrAl-coating type Accident-Tolerant Fuel (ATF) claddings to enhance safety margin in such severe accident situations and evaluations for the performance in various aspects are on process. We established a single-rod type reflood quenching experiment setup to simulate the LOCA process. Unlike other conventional quenching experiment setup, our experiment setup is capable of heating during the reflooding process, simulating the decay heat in the real core. We installed heaters and thermocouples (TC) inside the cladding specimens to minimize any disturbances on the interfacial layer during the experiment. Currently the setup is on test run and we present experiment data and verification with conventional Zircaloy-4 claddings. We are going to conduct the reflood quenching experiment with KAERI's CrAl-coated ATF claddings to evaluate the cooling performances.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Turbomachine injection nozzle including a coolant delivery system

An injection nozzle for a turbomachine includes a main body having a first end portion that extends to a second end portion defining an exterior wall having an outer surface. A plurality of fluid delivery tubes extend through the main body. Each of the plurality of fluid delivery tubes includes a first fluid inlet for receiving a first fluid, a second fluid inlet for receiving a second fluid and an outlet. The injection nozzle further includes a coolant delivery system arranged within the main body. The coolant delivery system guides a coolant along at least one of a portion of the exterior wall and around the plurality of fluid delivery tubes.

42 ENGINEERING↗

Hybrid large-eddy simulation with adaptive downstream anisotropic eddy viscosity model

Turbulence pervades most flows of engineering interest, and its prediction remains a challenge on both accuracy and cost. One promising predictive approach that reduces cost combines large-eddy simulation (LES) with simulation based on Reynolds averaged Navier–Stokes equations (RANS). This study presents a method to overcome stability and accuracy issues associated with these hybrid LES-RANS methods. The method developed involves extracting the Reynolds stresses from the upstream LES solution and then using that information to convert the downstream RANS model from a scalar eddy-viscosity model to an anisotropic nonlinear eddy-viscosity model. The method developed differs from the downstream tensorial eddy-viscosity model by being independent of the coordinate system. The method developed was evaluated by computing film cooling of a flat plate with the coolant injected through one row of circular holes. Results obtained show instabilities at the LES-to-RANS interface to be eliminated. Also, the method developed yielded solutions that compare reasonably well with those from LES, even though a significant portion of the flow is computed by the adapted anisotropic RANS model instead of LES, which significantly reduced the number of grid points and computational time needed. Since modification of the downstream RANS model is based on information extracted from the upstream LES solution, the method developed is adaptive to the problem being studied.

42 ENGINEERING↗

Experimental Investigation on Additively Manufactured Transpiration and Film Cooling Structures

The last 50 years has witnessed significant improvement in film cooling technologies while transpiration cooling is still not implemented in turbine airfoil cooling. Although transpiration cooling could provide higher cooling efficiency with less coolant consumption compared to film cooling, the fine pore structure and high porosity in transpiration cooling metal media always raised difficulties in conventional manufacturing. Recently, the rapid development of additive manufacturing (AM) has provided a new perspective to address such challenge. With the capability of the innovative powder bed selective laser metal sintering (SLMS) AM technology, the complex geometries of transpiration cooling part could be precisely fabricated and endued with improved mechanical strength. This study utilized the SLMS AM technology to fabricate the transpiration cooling and film cooling structures with Inconel 718 superalloy. Five different types of porous media including two perforated plates with different hole pitches, metal sphere packing, metal wire mesh, and blood vessel shaped passages for transpiration cooling were fabricated by EOS M290 system. One laidback fan-shaped film cooling coupon was also fabricated with the same printing process as the control group. Heat transfer tests under three different coolant mass flow rates and four different mainstream temperatures were conducted to evaluate the cooling performance of the printed coupons. The effects of geometry parameters including porosity, surface outlet area ratio, and internal solid–fluid interface area ratio were investigated as well. The results showed that the transpiration cooling structures generally had higher cooling effectiveness than film cooling structure. The overall average cooling effectiveness of blood vessel-shaped transpiration cooling reached 0.35, 0.5, and 0.57, respectively, with low (1.2%), medium (2.4%), and high (3.6%) coolant injection ratios. The morphological parameters analysis showed the major factor that affected the cooling effectiveness most was the internal solid–fluid interface area ratio for transpiration cooling. This study showed that additive manufactured transpiration cooling could be a promising alternative method for turbine blade cooling and worthwhile for further investigations.

Engineering↗