Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solution for Direct Solar Impingement Problem on Landsat-7 ETM+ Cooler Door During Cooler Outgas in Flight

There was a thermal anomaly of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) radiative cooler cold stage during the cooler outgas phase in flight. With the cooler door in the outgas position and the outgas heaters enabled, the cold stage temperature increased to a maximum of 323 K when the spacecraft was in the sunlight, which was warmer than the 316.3 K upper set point of the outgas heater controller on the cold stage. Also, the outgas heater cycled off when the cold stage was warming up to 323 K. A corrective action was taken before the attitude of the spacecraft was changed during the first week in flight. One orbit before the attitude was changed, the outgas heaters were disabled to cool off the cold stage. The cold stage temperature increase was strongly dependent on the spacecraft roll and yaw. It provided evidence that direct solar radiation entered the gap between the cooler door and cooler shroud. There was a concern that the direct solar radiation could cause polymerization of hydrocarbons, which could contaminate the cooler and lead to a thermal short. After outgas with the cooler door in the outgas position for seven days, the cooler door was changed to the fully open position. With the cooler door fully open, the maximum cold stage temperature was 316.3 K when the spacecraft was in the sunlight, and the duty cycle of the outgas heater in the eclipse was the same as that in the sunlight. It provided more evidence that direct solar radiation had entered the gap between the cooler door and cooler shroud. Cooler outgas continued for seven more days, with the cooler door fully open. The corrective actions had prevented overheating of the cold stage and cold focal plane array (CFPA), which could damage these two components. They also minimized the risk of contamination on the cold stage, which could lead to a thermal short.

Choi, Michael K.↗

The Goddard Space Flight Center mechanical cooler program

The Philips Stirling Cooler Program will ensure that a cooler is available to meet NASA's needs in the 40 to 120K temperature range in the 1990's. The Creare turbomachinery based cooler may provide an improved cooler for the 40 to 120K range. The design of advanced multistage coolers for use down to 2K will begin in 1988. Requirements, the history of the Stirling cooler, features of the photoflight cooler, advantages of the Philips cooler, mechanical reliability, and potential advantages of the Creare reverse Brayton cycle cooler are presented in viewgraph form.

Castles, Stephen H.↗

Current developments in NASA cryogenic cooler technology

Cooler technologies that are being developed by NASA to meet the varying temperature and cooling power requirements of NASA instruments are described. In addition to providing the desired operating temperature and cooling power by stabilizing temperatures from room temperature down to 0.1 K or less, these coolers will have working lifetimes commensurate with the 10 to 15 year lifetime expected for major future NASA facilities. The types of coolers currently under development are discussed, including radiative coolers, solid cryogen coolers, surface tension confined liquid cryogen coolers, mechanical coolers, liquid helium dewars, He3 adsorption coolers, adiabatic demagnetization refrigerators, and dilution refrigerators.

Castles, Stephen H.↗

Thermal Assessment of Landsat-7 ETM+ Radiative Cooler in Instrument and Spacecraft Thermal Vacuum Tests and in Flight

During the radiative cooler cool-down phase of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument thermal vacuum test #3, the coldest temperature that the Cold Focal Plane Array (CFPA) achieved was 89.5 K. The cold stage/CFPA temperature decreased from 315 K to 89.5 K in 80 hours. In the spacecraft and instrument integrated thermal vacuum test, the cold stage/CFPA temperature decreased from 315 K to 86.9 K in 80 hours, and was still decreasing at a rate of 0.08 K/hr when the cool-down was terminated. The cool-down was faster, and a colder CFPA temperature was obtained. In flight, the cooler cool- down was even faster, and colder. The cold stage/CFPA temperature decreased from 315 K to 89.7 K in 33 hours, and was still decreasing at a rate of 1 K/hr when cool- down was terminated at 89.7 K. The factors that affected the ETM+ cooler cool-down are the radiation heat sink temperature for the cold stage and intermediate stage, parasitic radiation heat load to the cooler, parasitic conduction heat load to the cooler, and cooler outgas time preceding cooler cool-down.

Choi, Michael K.↗

Refurbishment of the cryogenic coolers for the Skylab earth resources experiment package

Skylab Earth Resources Experiment Package (EREP) experiments, S191 and S192, required a cold temperature reference for operation of a spectrometer. This cold temperature reference was provided by a subminiature Stirling cycle cooler. However, the failure of the cooler to pass the qualification test made it necessary for additional cooler development, refurbishment, and qualification. A description of the failures and the cause of these failures for each of the coolers is presented. The solutions to the various failure modes are discussed along with problems which arose during the refurbishment program. The rationale and results of various tests are presented. The successful completion of the cryogenic cooler refurbishment program resulted in four of these coolers being flown on Skylab. The system operation during the flight is presented.

Smithson, J. C.↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

ATS-F radiant cooler contamination test in a hydrazine thruster exhaust

A test was conducted under simulated space conditions to determine the potential thermal degradation of the ATS-F radiant cooler from any contaminants generated by a 0.44-N(0.1-lbf) hydrazine thruster. The radiant cooler, a 0.44-N(0.1-lbf)hydrazine engine, and an aluminum plate simulating the satellite interface were assembled to simulate their flight configuration. The cooler was provided with platinum sensors for measuring temperature, and its surfaces were instrumented with six quartz crystal microbalance units (QCM) to measure contaminant mass deposits. The complete assembly was tested in the molecular sink vacuum facility (Molsink) at the Jet Propulsion Laboratory. This was the first time that a radiant cooler and a hydrazine engine were tested together in a very-high-vacuum space simulator, and this test was the first successful measurement of detectable deposits from hydrazine rocket engine plumes in a high vacuum. The engine was subjected to an accelerated duty cycle of 1 pulse/min, and after 2-hr of operation, the QCMs began to shift in frequency. The tests continued for several days and, although there was considerable activity in the QCMs, the cooler never experienced thermal degradation.

Chirivella, J. E.↗

Radiant coolers - Theory, flight histories, design comparisons and future applications

Radiant coolers have been developed for application to the cooling of infrared detectors aboard NASA earth observation systems and as part of the Defense Meteorological Satellite Program. The prime design constraints for these coolers are the location of the cooler aboard the satellite and the satellite orbit. Flight data from several coolers indicates that, in general, design temperatures are achieved. However, potential problems relative to the contamination of cold surfaces are also revealed by the data. A comparison among the various cooler designs and flight performances indicates design improvements that can minimize the contamination problem in the future.

Donohoe, M. J.↗

Development of a space qualified Surface Tension Confined Liquid Cryogen Cooler (STCLCC)

The Surface Tension Confined Liquid Cryogen Cooler (STCLCC), a new type of cryogenic cooler which is being developed by the NASA-GSFC for spaceflight payloads, is described. The STCLCC will be capable of maintaining instrumentation within the temperature range of 10-120 K and will allow liquid cryogens to be flown in space without the risk of liquid being entrained in the vent gas. A low-density open-cell material in the STCLCC acts as a 'sponge', with the surface tension trapping the liquid cryogen within its pores and keeping the liquid away from the cooler's vent during launch, zero-g operations, and landing. It is emphasized that the STCLCC concept is amenable to a wide variety of applications, whenever a passive low-cost cooler is required or when the on-orbit service of a cooler would increase a mission's lifetime.

Castles, Stephen H.↗

Mechanical cooler-to-Dewar interfacing in a long-lifetime, hybrid stored cryogen system

The means for making efficient use of mechanical coolers to limit the parasitic heating into the Dewar are addressed. Thermal efficiency is achieved by minimizing the parasitic heating and thermal impedance of the cooler-to-Dewar interface within the mechanical constraints. The important issues related to compatibility with the instrument system are also briefly discussed. Parasitic heating from the nonoperating (reserved or failed) cooler pair can be reduced with an active thermal switch that isolates the cooler cold tips from the cold finger. An analysis was performed to determine the optimal switch-operating characteristics for this application. Requirements associated with the use of the coolers, analyses performed, and the interface design concept are discussed.

Hopkins, R. A.↗

Spaceborne Passive Radiative Cooler

Radiative coolers are passive refrigeration devices for satellites and space probes that provide refrigeration for an infrared or other type of detector that operates at cryogenic temperatures. Typically a cooler can supply 20 mW of cooling at about 85 K, and over 500 mW of cooling at about 165 K. The exact cooler temperatures and heat loads are dependent upon the clear field of view of the cooler to space. Some features of the Arthur D. Little passive radiative cooler are given.

Mathias, S.↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Optical Properties of Wigglers for EIC Ring Electron Cooler

Electron Ion Collider (EIC) requires cooling of protons at top energy (275 GeV) to achieve the average design luminosity. Such a cooler must be capable of counteracting an IBS-driven emittance growth in proton bunches. The Ring Electron Cooler (REC) is a candidate for the EIC top energy cooler. The REC is a non-magnetized RF-based 150 MeV electron cooler, in which electrons are kept in the storage ring and re-utilized for several million turns. The REC is equipped with 18 damping wigglers, which keep electrons’ emittance constant by counteracting both electrons’ IBS and a proton electron beam-beam scattering happening in the cooling section. These wigglers operate at a relatively low energy but must have a rather high field to provide the required radiation cooling of electrons. As a result of this unique range of parameters, the wigglers’ optics exhibits interesting features The actual design parameters of the wigglers will be finalized in the REC lattice optimization.

43 PARTICLE ACCELERATORS↗

Radiation cooler for 10 micrometer wavelength engineering model receiver model no. 7172, serial no. 201

The design, fabrication, and testing of a radiative cooler are described. This cooler is an engineering model suitable for bench testing in the laboratory as a part of the 10-micrometer wavelength engineering model receiver, and conforms to the standard radiative cooler configuration, except that the inner stage and its support system were redesigned to accommodate the larger, heavier SAT detector. This radiative cooler will cool the detector to cryogenic temperature levels when the receiver is in a space environment or in a suitable thermal vacuum chamber. Equipment specifications are given along with the results of thermal tests, vibration tests, and electrical integrity tests.

Source record↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

Preliminary design trade-offs for a multi-mission stored cryogen cooler

Preliminary design studies were performed for a multi-mission solid cryogen cooler having a wide range of application for both the shuttle sortie and free flyer missions. This multi-mission cooler (MMC) is designed to be utilized with various solid cryogens to meet a wide range of instrument cooling from 10 K (with solid hydrogen) to 90 K. The baseline cooler utilizes two stages of solid cryogen and incorporates an optional, higher temperature third stage which is cooled by either a passive radiator or a thermoelectric cooler. The MMC has an interface which can accommodate a wide variety of instrument configurations. A shrink fit adapter is incorporated which allows a drop-in instrument integration. The baseline design provides cooling of approximately 1 watt over a 60 to 100 K temperature range and about 0.5 watts from 15 to 60 K for a one year lifetime. For low cooling loads and with use of the optional radiator shield, cooling lifetimes as great as 8 years are predicted.

Sherman, A.↗