Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High Propane and Isobutane Adsorption Cooling Capacities in Zirconium-Based Metal–Organic Frameworks Predicted by Molecular Simulations

Adsorption cooling systems are emerging alternatives to traditional compression-based cooling systems due to their reduced electricity costs. Metal–organic frameworks (MOFs) have the potential to be ideal adsorbent materials for this application, as they can be tuned to have desired adsorption behavior for different refrigerants. In this study, we studied the adsorption behaviors of propane and isobutane, which are environmentally friendly refrigerants that have been recommended as substitutes for (hydro)chlorofluorocarbons, in two mesoporous Zr-based MOFs, namely, NU-1000 and NU-1003, which have the same topology but different pore sizes. Both MOFs showed high cooling capacities with the refrigerants, and for isobutane, the cooling capacities were 2 to 4 times higher than MIL-101, which is the only MOF with a previously reported isobutane adsorption cooling capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro- & Nano-Technology: A Critical Design Key in Advanced Thermoelectric Cooling Systems

Advanced, thermoelectric cooling technologies now are receiving more research attention to provide cooling in advanced vehicles and residential systems to assist in increasing overall system energy efficiency and reduce greenhouse gas impacts from leakage by current R-134a systems. This work explores the systems-related impacts, barriers, and challenges of using micro-technology solutions integrated with advances in nano-scale thermoelectric materials in advanced TE cooling systems. Integrated system-level analyses that simultaneously account for thermal energy transport into / dissipation out of the TE device, environmental effects, temperature-dependent TE and thermo-physical properties, thermal losses, and thermal and electrical contact resistances are presented to establish accurate optimum system designs using both BixSb2-xTe3 / Bi2Te3 TE systems and Bi2Te3 TE systems. This work established the design trends and identified optimum design regimes and metrics for these types of systems that will minimize system mass, volume and cost to maximize their commercialization potential in vehicular and residential applications. The relationships between important design metrics, like coefficient of performance, specific cooling capacity and cooling heat flux requirements, upper limits, and critical differences in these metrics in BixSb2-xTe3 / Bi2Te3 TE systems and Bi2Te3 TE systems are explored and quantified. Finally, the work discusses the critical role that micro-technologies and nano-technologies can play in enabling miniature TE cooling systems in advanced vehicle and residential applications and gives some key relevant examples.

36 MATERIALS SCIENCE↗

CryoTARPOS Vibration Mitigation System for Layered Experiments

The goal of this project is to implement a system that can eliminate or mitigate vibration so that clear images can be taken without bypassing the cryocooler. By allowing for layer characterization and cryocooler operation at the same time, cooling capacity and thermal stability of the target would be improved, and more layer characterization data could be taken. Increased cooling capacity and thermal stability could allow for layering during occasional off normal conditions that would typically result in a loss of temperature control and NIF operational delays ranging from several hours to several days per month. The increased cooling capacity and thermal stability could also allow for layering of new target platforms that have less cooling margin. Additional layer images could be used for better characterization of defects and non-uniformities in the layer and would reduce the likelihood of layer seed loss, which typically adds ~12 hours per week in layering time. Motion blur from vibration due to off normal activity in the NIF Target Bay could also be mitigated that would usually result in NIF operational delays of several hours every month.

42 ENGINEERING↗

Lithium chloride - Expanded graphite composite sorbent for solar powered ice maker

Consolidated composite material made from expanded graphite (EG) powder impregnated with LiCl salt is proposed for use in solar powered adsorption ice makers. Laboratory experiments were done to test the adsorption and desorption performance of the sorbent under different temperature conditions suitable for solar energy utilization. More than 75% of the reaction between LiCl and ammonia was completed after 30 min of synthesis at evaporation temperatures of -10 and -5 C and adsorption temperature between 25 and 35 C. Under the same period, it was possible to obtain 80% conversion in the desorption phase, when the generation temperatures ranged between 75 and 80 C, and the condensation temperature varied from 25 to 35 C. The highest average specific cooling power during the synthesis phase was 117 W per kg of the block. The calculated theoretical coefficient of performance (COP) under different cycle conditions was nearly constant at 0.47. Moreover, the new composite sorbent showed higher Specific Cooling Capacity (SCC), compared to activated carbon (AC)/methanol pair. Experiments done with blocks with different proportion of EG, showed that the proportion of EG influence the cooling capacity per unit mass of salt and had almost no influence on the cooling capacity per unit mass of the block. Moreover, the reaction enthalpy ({delta}H) and entropy ({delta}S) were calculated from experimental data obtained experimentally, and confirmed previous reported values. (author)

14 SOLAR ENERGY↗

Modular Thermal Hub For Building Cooling, Heating and Water Heating

A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low-grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling-up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Thermal Hub For Building Cooling, Heating and Water Heating

A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.

HVAC↗

Impacts of building geometry modeling methods on the simulation results of urban building energy models

We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building's footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

THE CRYOPLANT FOR THE ITER NEUTRAL BEAM TEST FACILITY TO BE BUILT AT RFX IN PADOVA, ITALY

The Neutral Beam Test Facility (NBTF), planned to be constructed in Padua (Italy), will constitute the prototype of the two Neutral Beam Injectors (NBI), which will be installed in the ITER plant (Cadarache-France). The NBTF is composed of a 1 MV accelerator that can produce a 40 A deuteron pulsed neutral beam particles. The necessary vacuum needed in the accelerator is achieved by two large cryopumps, designed by FZK-Karlsruhe, with radiation shields cooled between 65 K and 90 K and with cryopanels cooled by 4 bar supercritical helium (ScHe) between 4.5 K and 6.5 K. A new cryoplant facility will be installed with two large helium refrigerators: a Shield Refrigerator (SR), whose cooling capacity is up to 30 kW between 65 K and 90 K, and a helium Main Refrigerator (MR), whose equivalent cooling capacity is up to 800 W at 4.5 K. The cooling of the cryopanels is obtained with two (ScHe) 30 g/s pumps (one redundant), working in a closed cycle around 4 bar producing a pressure head of 100 mbar. Two heat exchangers are immersed in a buffer dewar connected to the MR. The MR and SR different operation modes are described in the paper, as well as the new cryoplant installation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development, calibration, and validation of a novel gray-box energy model for residential split air conditioners

Energy models for vapor compression refrigeration in residential air conditioners have been developed through white-box, gray-box, and black-box methods in decades. However, existing white-box and gray-box models require complicated equations with detailed geometries while black-box models require substantial experimental data. Further, this paper aims to develop and validate a simple gray-box steady-state energy model without the need for detailed geometries, which can accurately predict the cooling capacity and electrical power input based on outdoor and indoor air conditions, and supply airflow rates. First three state variables, including the evaporation and condensation temperatures, and refrigerant mass flowrate, are applied to develop the energy model and are solved by three physical equations, including the energy conservations at the evaporator and condenser, and the refrigerant volume-mass flow correlation of the compressor. Secondly, seven performance property functions related to three state variables and three physical equations are identified and calibrated by simple temperature and power measurements. Finally, field experiments are conducted on a residential air conditioner to calibrate these performance property functions and validate the developed model. The validated results reveal the model can accurately predict the cooling capacity and electrical power input, with the normalized root mean square errors of 2.3% and 0.87% respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LBNF/DUNE Nitrogen Refrigeration System Update

The Deep Underground Neutrino Experiment (DUNE) is supported by the infrastructure of the Long Baseline Neutrino Facility (LBNF). The central feature of DUNE is the liquid argon filled cryostats, which house the neutrino detector components. In order to maintain the argon in a liquid state, heat must be continuously removed. Argon condensers will remove this heat, and liquefy the argon, through the evaporation of liquid nitrogen. The supply of liquid nitrogen relies heavily on a near-industrial scale nitrogen refrigeration/liquefaction system. The nitrogen system will be a closed loop, in which the liquid nitrogen is supplied to users and, after being vaporized, is recycled to the nitrogen liquefaction units to be liquefied again. The system will also include nitrogen generation, to increase inventory in the closed loop, as well as to make up for losses. All of this will be installed nearly one mile underground (1.5km) on the 4850 level of the Sanford Underground Research Facility (SURF). The final DUNE vision requires 400kW of liquid nitrogen cooling capacity. Based on the operation modes and phased installation of the experiment, modularity of this cooling capacity is required. Nitrogen liquefaction will occur in four units which will afford a wide operational range of production (nominally 100kW each). Due to the experiment’s location deep underground in an inactive gold mine, there are unique and challenging constraints. These include limited access, footprint, and utilities. This poster describes the engineering effort, and provides an overview of the refrigeration system. The design includes a unique compressor arrangement which is covered in detail. Pictures and models are included where possible to help visualize the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Thermal link design for conduction cooling of SRF cavities using cryocoolers

Superconducting radio frequency (SRF) cavities with quality factors ~1010 near 4 K have potential to be cooled using re-generative-cycle cryocoolers. Contrary to using liquid helium, cry-ogen-free operation can be realized by conductively linking a cavity to a cryocooler. The cavity-cryocooler thermal link needs careful design for balancing cooling capacity of the cryocooler with the dissipation rate in the cavity. We present a thermal analysis of a conduction-cooled SRF cavity that identifies the link thermal con-ductance requirement. The analysis uses published or expected RF dissipation characteristics of an Nb3Sn coated niobium cavity and in-house measured cooling capacity of a commercial pulse tube cryocooler. We describe mechanical design of a link that is con-structed using commercial high-purity aluminum and facilitates bolted-connection to elliptical SRF cavities. The thermal perfor-mance of the link is assessed by finite element simulations, taking into account temperature dependent thermal conductivities and measured thermal contact resistance of aluminum and niobium. The link is shown to support operation at an accelerating gradient of 10 MV/m with the lowest-known ‘perfect’ Nb3Sn surface re-sistance (10 nΩ) and also under non-ideal cases that assume certain static heat leak into the system and non-perfect Nb3Sn coatings

43 PARTICLE ACCELERATORS↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

The Design of an Ultra-Low Background Thermosyphon for the Majorana Demonstrator

The MAJORANA DEMONSTRATOR (MJD) is an ultra-low background neutrinoless double-beta decay (0νββ) experiment that will deploy up to 40 kg of high purity germanium detectors (HPGe). The goal of this experiment is to demonstrate the feasibility of building a detector array with less than 1 event/ton-year in a 4 keV region of interest around the 0νββ signal. HPGe diodes, when used as ionizing radiation detectors, need to be maintained at a temperature close to that of liquid nitrogen (77 K). This work describes the R&D results of a cryogenic system capable of meeting the requirements of low background and the cooling capacity required to successfully operate such a detector system. The MJD germanium detector modules will operate at liquid nitrogen temperature to provide adequate cooling for a full range of HPGe impurity concentrations. This paper shows the experimental results obtained using a two-phase horizontal thermosyphon using liquid nitrogen as the MJD’s cooling system. The cold test shows that the proposed thermosyphon has sufficient cooling power to handle the heat load of an MJD module. Results for the temperature gradient across the thermosyphon, cooling capacity, and design considerations demonstrate that the thermosyphon can effectively remove the calculated heat load of each module of the experiment. The thermosyphon will be bolted to a cold plate from which detector strings will hang. The thermal conductivity of a mockup of the MJD bolted thermal joint is experimentally determined to be below 0.1 K/W.

Detector arrays↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Comprehensive Compressor Calorimeter Testing of Lower-GWP Alternative Refrigerants for Heat Pump and Medium Temperature Refrigeration Applications

In response to environmental concerns raised by the use of refrigerants with high Global Warming Potential (GWP), the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) has launched an industry-wide cooperative research program, referred to as the Low-GWP Alternative Refrigerants Evaluation Program (AREP), to identify and evaluate promising alternative refrigerants for major product categories. This paper reports one of the Oak Ridge National Laboratory (ORNL) contributions to AREP. It compares performance of alternative refrigerants to that of R-410A and R-404A for heat pump and medium temperature applications, respectively. The alternatives reported in this paper are: R-32, DR-5, and L-41a for R-410A and ARM-31a, D2Y-65, L-40, and a mixture of R-32 and R-134a for R-404A. All performance comparison tests were conducted using scroll compressors of ~1.85 tons (6.5 kW) cooling capacity. Tests were conducted over a range of combinations of saturation suction and saturation discharge temperatures for both compressors. The tests showed that, in general, energy efficiency ratio (EER) and cooling capacity of R-410A alternative refrigerants were slightly lower than that of the baseline refrigerant with a moderate increases in discharge temperature. On the other hand, R-404A alternative refrigerants showed relative performance dependence on saturation suction and saturation discharge temperatures and larger increases in discharge temperature than for the R-410A alternatives. This paper summarizes the relative performance of all alternative refrigerants compared to their respective baseline.

Alternative Refrigerants↗

Experimental Evaluation of a Residential Refrigerator with a Novel Rotating Heat Exchanger as an Evaporator

Residential refrigerator designs have improved significantly over the recent years to achieve the required federal minimum energy standard and match with consumer expectations. Designers have been able to use innovative design features and components; however, evaporator designs have lagged in performance improvement due to the need to properly manage frost and maximize the freezer interior volume. Rotating Heat Exchangers (RHX) provide an innovative solution that addresses both of these concerns. The rotation of the fins results in continuous disruption to the boundary layer, hence reducing the overall thermal resistance. Thus, for the same capacity, the heat transfer area can be greatly reduced. Furthermore, the rotation inhibits frost growth on the fins and reduces the time and frequency of defrosting. In this paper, we present an experimental evaluation of the RHX in a benchtop refrigerant loop system showing results for different operating configurations. Cooling capacity, cooling COP, and overall energy consumption are investigated. High-speed imaging is also used to capture frost growth patterns over time on the RHX fins in the presence and absence of rotation. The results show that the rotating heat exchanger evaporator is capable of meeting the 100 W capacity requirement of residential refrigerators, while offering the potential of significant reduction in defrost energy consumption.

Evaporator↗