Yonkers Urban Development: Utilizing NASA Earth Observations to Identify Environmental and Social Drivers of Urban Heat Vulnerability and Model Urban Cooling Interventions in Yonkers, New York

The City of Yonkers, New York, is located directly north of the Bronx in Westchester County and currently hosts a population of nearly 200,000. In response to increasing hot-weather episodes, the risk of heat-related illnesses and mortality is disproportionately affecting neighborhoods in Yonkers historically subjected to race-based housing segregation. NASA DEVELOP collaborated with Groundwork Hudson Valley to determine regions within Yonkers that are experiencing the most intense urban heat island effects, identify and rank sociodemographic and environmental determinants of increasing community-level vulnerability, map these vulnerabilities as a combined vulnerability index, complete a proximity analysis of walkability to local cooling centers and health facility locations, and model potential cooling strategies. The study area consisted of Yonkers, NY and the analyses used data from 2015-2020 (June through August). The project utilized NASA Earth observation products including Landsat 4 and 5 Thematic Mapper (TM), Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Terra Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). We assessed the benefits of different heat-mitigation scenarios by utilizing the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model. Results from these analyses can be used by Groundwork Hudson Valley, supporting the New York State’s Climate Safe Communities Certifiable Planning Actions, expanding knowledge on the relationship between historic redlining and environmental equity, and informing their Climate Safe Neighborhoods initiative to identify and prioritize mitigation efforts to abate the worst impacts of extreme heat.

Jillian Walechka↗

H2 fueled flightweight ramjet construction and test

The ACES Program began the investigation of regeneratively cooled ramjet engines for propelling aircraft at Mach 6 to 8 flight regimes while collecting and processing air for later use as oxidizer in rocket propulsion into an orbit flight mode. The Marquardt Company had as its prime task the design and demonstration of a ramjet capable of steady state operating using hydrogen as the regenerative coolant and with fuel flow limited to a theta = 1. Marquardt progressed from shell type combustors to advanced tubular combustion chambers in direct connect test rigs. The first tests were made with water cooled center bodies and plug nozzles using a pebble bed air heater to simulate flight air temperature. Later tests were made on completely H2 cooled flight weight V/G assemblies direct connected to a SUE burner heater. Design studies were also conducted on integrated systems for take-off capability using offset turbojets connected to 2-D or axisymmetric inlets. An 18 inch hypersonic ramjet evaluation scale model was designed based on the hot test results using a fully V/G inlet and exit nozzle. This thruster would provide 25000 lbs. of thrust with an estimated weight of 250 lbs. A V/G inlet would also incorporate an inlet seal for possible take-off thrust by rocket operation. Hypersonic ramjet construction features and chamber thrust development are discussed.

Malek, Albert↗

Numerical simulation of natural convection in a spherical container due to cooling at the center (idealization of the Lal/Kroes experiment)

Natural convection in a spherical container with cooling at the center was numerically simulated using a numerical fluid dynamics computer program. The numerical analysis was simplified by assuming axisymmetric flow in the spherical container, with the symmetry axis being a sphere diagonal parallel to the gravity vector. This axisymmetric spherical geometry was intended as an idealization of the proposed Lal/Kroes crystal growing experiment to be performed on Spacelab. Results were obtained for a range of Rayleigh numbers from 25 to 10,000. The computed velocities were found to be approximately proportional to the Rayleigh number over the range of Rayleigh numbers investigated.

Robertson, S. J.↗

The cryogenic wind tunnel for high Reynolds number testing

An improved way to increase the Reynolds numbers capability of wind tunnels has been developed at the Langley Research Center. Cooling the test gas to cryogenic temperatures by spraying liquid nitrogen into the tunnel circuit increases Reynolds number with no increase in dynamic pressure and a reduction in drive power. In addition, the ability to vary the temperature of the test gas independently of pressure and Mach number allows for the first time the independent determination of Reynolds number, Mach number, and aeroelastic effects. A new fan-driven transonic cryogenic tunnel being built at the Langley Research Center will provide an order of magnitude increase in Reynolds number capability over existing transonic tunnels in the United States when it is completed later this year.

Kilgore, R. A.↗

Fairfax County Urban Development: Identifying Urban Heat Mitigation Strategies for Climate Adaptation Planning in Fairfax County, Virginia

Extreme high temperatures lead to increased instances of cardiovascular disease, pulmonary disease, and even death, as well as increased energy consumption and infrastructure costs. People in urbanized areas experience higher temperatures than rural areas due to diminished vegetation and increased impervious surfaces which absorb and radiate heat. Fairfax County, Virginia has embarked on Resilient Fairfax, a program aimed at addressing climate adaptation and resilience. The DEVELOP team partnered with the Fairfax County Office of Environmental and Energy Coordination (OEEC) to assess the extent of the urban heat island effect on the county and its most vulnerable populations. The team used data from Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) for the years 2013 to 2021 and found that the hottest spots were in densely urbanized areas, with temperatures as much as 47°F above that of undeveloped reference areas. The team used the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) urban cooling model and determined that areas with higher tree canopy cover had greater heat mitigation capacity. Estimates from the InVEST model showed that a 4.5% increase in canopy cover across the county could result in a temperature reduction of up to 2.4°F in some areas. The results will allow partners to assess heat distribution across Fairfax County and implement effective mitigation strategies, including locating prime locations for cooling centers and increasing canopy cover.

W. Pierce Holloway↗

Self-regulated cooling flows in elliptical galaxies and in cluster cores - Is exclusively low mass star formation really necessary?

A self-consistent treatment of the heating by supernovae associated with star formation in a spherically symmetric cooling flow in a cluster core or elliptical galaxy is presented. An initial stellar mass function similar to that in the solar neighborhood is adopted. Inferred star-formation rates, within the cooling region - typically the inner 100 kpc around dominant galaxies at the centers of cooling flows in XD clusters - are reduced by about a factor of 2, relative to rates inferred when the heat input from star formation is ignored. Truncated initial mass functions (IMFs) are also considered, in which massive star formation is suppressed in accordance with previous treatments, and colors are predicted for star formation in cooling flows associated with central dominant elliptical galaxies and with isolated elliptical galaxies surrounded by gaseous coronae. The low inferred cooling-flow rates around isolated elliptical galaxies are found to be insensitive to the upper mass cutoff in the IMF, provided that the upper mass cutoff exceeds 2 M solar mass. Comparison with observed colors favors a cutoff in the IMF above 1 M solar mass in at least two well-studied cluster cooling flows, but a normal IMF cannot be excluded definitively. Models for NGC 1275 support a young (less than about 3 Gyr) cooling flow. As for the isolated elliptical galaxies, the spread in colors is consistent with a normal IMF. A definitive test of the IMF arising via star formation in cooling flows requires either UV spectral data or supernova searches in the cooling-flow-centered galaxies.

Silk, J.↗

Summary of NASA Lewis Research Center solar heating and cooling and wind energy programs

Plans for the construction and operation of a solar heating and cooling system in conjunction with a office building being constructed at Langley Research Center, are discussed. Supporting research and technology includes: testing of solar collectors with a solar simulator, outdoor testing of collectors, property measurements of selective and nonselective coatings for solar collectors, and a solar model-systems test loop. The areas of a wind energy program that are being conducted include: design and operation of a 100-kW experimental wind generator, industry-designed and user-operated wind generators in the range of 50 to 3000 kW, and supporting research and technology for large wind energy systems. An overview of these activities is provided.

Vernon, R. W.↗

Summary of NASA-Lewis Research Center solar heating and cooling and wind energy programs

NASA is planning to construct and operate a solar heating and cooling system in conjunction with a new office building being constructed at Langley Research Center. The technology support for this project will be provided by a solar energy program underway at NASA's Lewis Research Center. The solar program at Lewis includes: testing of solar collectors with a solar simulator, outdoor testing of collectors, property measurements of selective and nonselective coatings for solar collectors, and a solar model-systems test loop. NASA-Lewis has been assisting the National Science Foundation and now the Energy Research and Development Administration in planning and executing a national wind energy program. The areas of the wind energy program that are being conducted by Lewis include: design and operation of a 100 kW experimental wind generator, industry-designed and user-operated wind generators in the range of 50 to 3000 kW, and supporting research and technology for large wind energy systems. An overview of these activities is provided.

Vernon, R. W.↗

Estimating Future Changes of Energy Demand for Heating and Cooling Buildings at NASA Centers GC23J-1198

With its unique and trusted earth observations, NASA is a critical source in informing decisions that will help achieve the U.S. goal of Net-Zero Greenhouse Gas (GHG) Emissions by 2050. NASA’s Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data holdings within the energy, agricultural, and building heating/cooling design industries. POWER packages solar and meteorological data from several NASA projects in a user friendly GIS-enabled web services system (https://power.larc.nasa.gov). As part of the development of new data products to support the energy and building heating/cooling design communities, we estimate the changes in energy required to heat and cool buildings in the future climate at 14 different NASA site locations spread throughout the continental United States, as projected by CMIP6 climate models under different emissions scenarios. Bias-corrected downscaled time series of meteorological variables are taken from NASA Earth Exchange (NEX) Global Daily Downscaled Projections (GDDP-CMIP6) downscaled climate model data. The spread between the different model projections is accounted for by analyzing both the ensemble average of 22 CMIP6 models and 6 representative models with different climate sensitivities and different interannual variability. Changes in energy use are estimated in two ways. First, changes in the total annual heating and cooling degree days (HDD and CDD, respectively) are calculated relative to the current climate. This is done at all 14 sites. Second, the downscaled time series are used as inputs into RETScreen(R), a clean energy management decision tool, to give an estimate of heating/cooling energy use for a typical office building. We use this estimation method with model data at Langley Research Center. In the next 50 years, the annual total of HDD (CDD) is projected to decrease by 8-38% (increase by 5-28%) at all sites, with the increase in CDD typically a larger magnitude the decrease in HDD. For a typical small office building at Langley Research Center, the amount of energy needed to cool increases by 33-54% and the amount of energy to heat decreases by 29-40%. POWER is working to develop long term climate data services based on these results to include in future data products to provide to users.

Bradley M. Hegyi↗

Really Cool Stars at the Galactic Center

New and existing K-band spectra for 19 Galactic center late-type stars have been analyzed along with representative spectra of disk and bulge M giants and supergiants. Absorption strengths for strong atomic and molecular features have been measured. The Galactic center stars generally exhibit stronger absorption features centered near Na I (2.206 microns) and Ca I (2.264 microns) than representative disk M stars at the same CO absorption strength. Based on the absolute K - band magnitudes and CO and H2O absorption strengths for the Galactic center stars and known M supergiants and asymptotic giant branch (AGB) stars, we conclude that only IRS 7 must be a supergiant. Two other bright stars in our Galactic center sample are likely supergiant as well. The remaining bright, cool stars in the Galactic center that we have observed are most consistent with being intermediate mass/age AGB stars. We identify four of the Galactic center stars as long period variables based on their K-band spectral properties and associated photometric variability. Estimates of initial masses and ages for the GC stars suggest multiple epochs of star formation have occurred in the Galactic center over the last 7-100 Myr. 0 1996 American Astronomical Society.

Blum, R. D.↗

Really Cool Stars at the Galactic Center

New and existing K-band spectra for 19 Galactic center late-type stars have been analyzed along with representative spectra of disk and bulge M giants and supergiants. Absorption strengths for strong atomic and molecular features have been measured. The Galactic center stars generally exhibit stronger absorption features centered near Na I (2.206 microns) and Ca I (2.264 microns) than representative disk M stars at the same CO absorption strength. Based on the absolute K-band magnitudes and CO and H2O absorption strengths for the Galactic center stars and known M supergiants and asymptotic giant branch (AGB) stars, we conclude that only IRS 7 must be a supergiant. Two other bright stars in our Galactic center sample are likely supergiants as well. The remaining bright, cool stars in the Galactic center that we have observed are most consistent with being intermediate mass/age AGB stars. We identify four of the Galactic center stars as long period variables based on their K-band spectral properties and associated photometric variability. Estimates of initial masses and ages for the GC stars suggest multiple epochs of star formation have occurred in the Galactic center over the last 7-100 Myr.

Blum, R. D.↗

The effect of direct heating and cooling of heat regulation centers on body temperature

Experiments were done on 28 rabbits in which puncture instruments were left in the brain for 1-2 days until the calori-puncture hyperthermia had passed and the body temperature was again normal. The instrument remaining in the brain was then used as a galvanic electrode and a second fever was produced, this time due to the electrical stimulus. It was concluded that heat is a centrally acting antipyretic and that cold is a centrally acting stimulus which produces hyperpyrexia cold-induced fever.

Barbour, H. G.↗

municipal recreation center is heated and cooled by solar energy

Major fraction of energy requirements for community building is ksupplied by Sun. The 238 flat plate solar collectors are roof mounted on single story structure enclosing gymnasium, locker area, and health care clinic; heat exchanger transfers collected energy to 6,000 gallon storage tank. Final report chronicles project from inception to completion, documenting performance, costs, operating modes, and data acquisition system. Appendix contains manufacturers' product literature and engineering drawings.

Source record↗

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

Thermal short improves sensitivity of cryogenically cooled maser

In-line, quarter-wave thermal short cools the center conductor of the signal-input coaxial transmission line to a cryogenically cooled traveling wave maser. It reduces both the thermal noise contribution of the coaxial line and the heat leak through the center conductor to the maser at 4.4 degrees K.

Clauss, R. C.↗

Lightweight, Actively Cooled Ceramic Matrix Composite Thrustcells Successfully Tested in Rocket Combustion Lab

In a joint effort between the NASA Glenn Research Center and the NASA Marshall Space Flight Center, regeneratively cooled ceramic matrix composite (CMC) thrustcells were developed and successfully tested in Glenn's Rocket Combustion Lab. Cooled CMC's offer the potential for substantial weight savings over more traditional metallic parts. Two CMC concepts were investigated. In the first of these concepts, an innovative processing approach utilized by Hyper-Therm, Inc., allowed woven CMC coolant containment tubes to be incorporated into the complex thruster design. In this unique design, the coolant passages had varying cross-sectional shapes but maintained a constant cross-sectional area along the length of the thruster. These thrusters were silicon carbide matrix composites reinforced with silicon carbide fibers. The second concept, which was supplied by Ceramic Composites, Inc., utilized copper cooling coils surrounding a carbon-fiber-reinforced carbon matrix composite. In this design, a protective gradient coating was applied to the inner thruster wall. Ceramic Composites, Inc.'s, method of incorporating the coating into the fiber and matrix eliminated the spallation problem often observed with thermal barrier coatings during hotfire testing. The focus of the testing effort was on screening the CMC material's capabilities as well as evaluating the performance of the thermal barrier or fiber-matrix interfacial coatings. Both concepts were hot-fire tested in gaseous O2/H2 environments. The test matrix included oxygen-to-fuel ratios ranging from 1.5 to 7 with chamber pressures to 400 psi. Steady-state internal wall temperatures in excess of 4300 F were measured in situ for successful 30-sec test runs. Photograph of actively cooled composite thrustcell fabricated by Hyper-Therm is shown. The thrustcell is a silicon-carbide-fiber-reinforced silicon carbide matrix composite with woven cooling channels. The matrix is formed via chemical vapor infiltration. Photograph of hot-fire test of an actively cooled carbon-fiber-reinforced carbon matrix composite thrustcell is also shown. This composite thrustcell, which was fabricated by CCI, Inc., was wound with copper cooling coils to contain the water coolant. The tests were run with oxygen fuel ratios up to seven with chamber pressures of 200 psia.

Jaskowiak, Martha H.↗