Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

Addressing Data Center Cooling Needs through the Use of Subsurface Thermal Energy Storage Systems

This study aims to evaluate the feasibility of addressing the cooling needs for information technology (IT) equipment in data centers by using reservoir thermal energy storage (RTES) to provide reliable and sustainable low-temperature fluid. This project focuses on the technical viability of operating such a system in Houston, Texas, which is a representative location for crypto mining data centers. An analysis has been performed to investigate the technical feasibility with climate data for Houston. Results show that data centers on the scale of 30 MW, and operating at a temperature of 27 degrees C, can be reliably cooled by a combined RTES and dry coolers setup. A techno-economic analysis will be performed and energy/water saving benefits will be quantified in the future. In addition, the study will be extended to other representative data center locations with different climates and geographical locations.

cooling↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

15 GEOTHERMAL ENERGY↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

Chainer, Timothy J.↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

Sandia’s Liquid-Cooled Data Center Boosts Efficiency and Resiliency

The Federal Energy Management Program (FEMP) encourages federal agencies and organizations to improve data center energy efficiency, which can offer tremendous opportunities for energy and cost savings. In this success story, a novel liquid cooling system provides reliable, resilient, and energy-efficient cooling for high performance computing (HPC) systems at Sandia National Laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sandia's Liquid-Cooled Data Center Boosts Efficiency and Resiliency

The Federal Energy Management Program (FEMP) encourages federal agencies and organizations to improve data center energy efficiency, which can offer tremendous opportunities for energy and cost savings. In this success story, a novel liquid cooling system provides reliable, resilient, and energy-efficient cooling for high-performance computing (HPC) systems at Sandia National Laboratories.

data center↗

Data Center Immersion Cooling: A Case Study and Summary of High-Performance Computing Cooling Technologies

The future of High Performance Computing (HPC) is carved out for all high-performance facilities. As computer processing increases exponentially, especially with the demand for AI training, more speed will equate to more computing density and ultimately more power draw and resource demand. Sandia National Laboratories has not seen or known of anything that would lead us to think this might change in the next 5 to 10 years.

97 MATHEMATICS AND COMPUTING↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

A Novel and Scalable Method for Microencapsulating Salt Hydrate Phase Change Materials in Core–Shell Fibers

Phase change materials (PCMs) are in high demand for applications such as thermal energy storage in buildings, electronics cooling, and thermal management of electric vehicle batteries and data centers. Among these materials, salt hydrate PCMs are particularly attractive due to their high thermal energy storage capacity and low cost. However, they suffer from two major issues: leakage in the melted phase and phase segregation during phase transitions. Microencapsulation is the primary process capable of addressing both of these challenges. However, there is no reliable or scalable method available for microencapsulating salt hydrate PCMs. As a result, the full potential of salt hydrates for building and data center applications has yet to be realized. In this work, we present an innovative method for the microencapsulation of salt hydrate PCMs using a co‐axial pushing technique. This process creates core–shell fibers, with the salt hydrate as the core and a polymer as the shell. Our approach demonstrates strong potential for scalable microencapsulation of salt hydrate PCMs. In conclusion, achieving scalability could enable their widespread use in applications such as data center cooling, battery thermal management, and building climate control.

Sharma, Jaswinder [Oak Ridge National Laboratory (↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗