Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cooling Tests of an Airplane Equipped with an NACA Cowling and a Wing-duct Cooling System

Cooling tests were made of a Northrop A-17A attack airplane successively equipped with a conventional.NACA cowling and with a wing-duct cooling system. The method of cooling the engine by admitting air from the propeller slipstream into wing ducts, passing it first through the accessory compartment and then over the engine from rear to front, appeared to offer possibilities for improved engine cooling, increased cooling of the accessories, and better fairing of the power-plant installation. The results showed that ground cooling for the wing duct system without cowl flap was better than for the NACA cowling with flap; ground cooling was appreciably improved by installing a cowl flap. Satisfactory temperatures were maintained in both climb and high-speed flight, but, with the use of conventional baffles, a greater quantity of cooling air appeared to be required for the wing duct system.

Turner, L I , Jr↗

Personal Cooling System

Cool Head, a personal cooling system for use in heat stress occupations, is a spinoff of a channeled cooling garment for space wear. It is portable and includes a heat exchanger, control display unit, liquid reservoir and temperature control unit. The user can eliminate 40 to 60 percent of his body's heat storage and lower heart rate by 50 to 80 beats a minute. The system is used by the Army, Navy, crop dusting pilots, heavy equipment operators and auto racing drivers and is marketed by Life Enhancement Technologies, LLC. Further applications are under consideration.

Source record↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling systems utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Modeling District Heating and Cooling Systems with URBANopt, GeoJSON to Modelica Translator, and the Modelica Buildings Library

The URBANopt project has successfully leveraged OpenStudio/EnergyPlus to model buildings and electrical systems at an urban scale; however, URBANopt has lacked the ability to model district thermal energy systems until recently. This paper will present the modeling infrastructure that was developed specifically for the analysis of district heating and cooling systems, and how it is integrated into the existing URBANopt framework. The paper also discusses the development of new models added to the Modelica Buildings Library to model various district energy system components including loads, energy transfer stations (ETS), distribution networks, and central plants. The paper describes how different building loads can be modeled including time series, TEASER reduced-order models, or Spawn of EnergyPlus models. URBANopt District Energy Systems allows the user to switch between the various configurations.

district heating and cooling↗

System Testing of Ground Cooling System Components

This internship focused primarily upon software unit testing of Ground Cooling System (GCS) components, one of the three types of tests (unit, integrated, and COTS/regression) utilized in software verification. Unit tests are used to test the software of necessary components before it is implemented into the hardware. A unit test determines that the control data, usage procedures, and operating procedures of a particular component are tested to determine if the program is fit for use. Three different files are used to make and complete an efficient unit test. These files include the following: Model Test file (.mdl), Simulink SystemTest (.test), and autotest (.m). The Model Test file includes the component that is being tested with the appropriate Discrete Physical Interface (DPI) for testing. The Simulink SystemTest is a program used to test all of the requirements of the component. The autotest tests that the component passes Model Advisor and System Testing, and puts the results into proper files. Once unit testing is completed on the GCS components they can then be implemented into the GCS Schematic and the software of the GCS model as a whole can be tested using integrated testing. Unit testing is a critical part of software verification; it allows for the testing of more basic components before a model of higher fidelity is tested, making the process of testing flow in an orderly manner.

Unit Test↗

Enhanced Air-Cooling System with Optimized Asynchronously-Cooled Thermal Energy Storage

A transformative dry-cooling system that includes two primary dry-cooling components has been developed in this project. The two main features of this new technology consist of: (a) an ultra-enhanced air-cooled condenser (ACC), with novel swirl-producing and boundary-layer disrupting enhanced surface on the air-side of the condenser that substantially increase the heat transfer coefficients, and (b) a novel daytime peak-load shifting system that reduces the ambient air inlet temperature for air cooling, consisting of a highly compact and enhanced air pre-cooler that transfers the heat load to a unique thermal energy storage (TES), and which is coupled to the ACC in (a).

20 FOSSIL-FUELED POWER PLANTS↗

Improved natural convection heat transfer correlations for reactor cavity cooling systems of high-temperature gas-cooled reactors: From computational fluid dynamics to Pronghorn

The Reactor Cavity Cooling System (RCCS) is a common reactor safety system in High Temperature Gas Cooled Reactors (HTGR) that removes heat from the Reactor Pressure Vessel (RPV) by radiation ($\sim 80\%$) and natural convection ($\sim 20\%$). For simulation of accident scenarios of HTGRs, intermediate fidelity and system codes models must be employed for limiting the models' execution time. While accurate quantification of the radiative heat transfer is available in these models, quantification of natural convection must rely on correlations of questionable accuracy for the Nusselt number. Commonly used correlations are based in experiments performed at low Rayleigh numbers and/or using isothermal walls in simplified geometries. Here, this work improves on the accuracy of natural convection heat transfer correlations in support for HTGR designs. These correlations include both local and average Nusselt numbers as a function of the global Rayleigh number, the local Rayleigh number, and the temperature profile at the hot wall of the RCCS. In the absence of dedicated experiments and the difficulty of performing high-fidelity simulations at realistic Rayleigh numbers, the data to fit the correlations are generated with Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier-Stokes (RANS) models. First, a careful selection of the RANS turbulence model is performed by comparing the results obtained with different RANS turbulence models against high fidelity simulations of natural convection at $Ra \ 1 \times 10^{11}$ in a rectangular cavity. Next, the selected model is used to perform simulations of an HTGR cavity at different high Rayleigh numbers $\in [6.1 \times 10^{11},2.9 \times 10^{13}]$ to encompass several HTGR designs, assuming an isothermal RPV wall. The results obtained are used to fit a correlation for the average and space-varying Nusselt number as a function of the global and local Rayleigh numbers via a sparsity-promoting least-squares method. The selected RANS model is then used to perform simulations of a PBMR 400 HTGR cavity with the temperature profiles at the RPV wall obtained during a PLOFC transient. We use the results obtained to fit a temperature-dependent correction to the space-varying Nusselt number with the sparsity-promoting least-squares method. The results obtained in this work, enable system-level codes, such as Pronghorn, to perform higher-fidelity simulations of the heat exchange process in the RCCS while still maintaining a low computational cost.

42 ENGINEERING↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Design and evaluation of active cooling systems for Mach 6 cruise vehicle wings

Active cooling systems, which included transpiration, film, and convective cooling concepts, are examined. Coolants included hydrogen, helium, air, and water. Heat shields, radiation barriers, and thermal insulation are considered to reduce heat flow to the cooling systems. Wing sweep angles are varied from 0 deg to 75 deg and wing leading edge radii of 0.05 inch and 2.0 inches are examined. Structural temperatures are varied to allow comparison of aluminum alloy, titanium alloy, and superalloy structural materials. Cooled wing concepts are compared among themselves, and with the uncooled concept on the basis of structural weight, cooling system weight, and coolant weight.

Mcconarty, W. A.↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

Chainer, Timothy J.↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes two highly adsorptive structures positioned to receive thermal energy from a thermal energy source, each highly adsorptive structure includes a substrate and a metal-organic framework (MOF) coupled to the respective substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The adsorptive cooling system includes a cooling unit and a circulation system adapted for circulating the refrigerant from one of the highly adsorptive structures to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to the same or other highly adsorptive structure. Each substrate may include a plurality of microchannels, providing ingress and egress paths for a refrigerant, defined by grooves in a surface of the substrate nearest the MOF and/or surfaces of a plurality of microcapillaries of the substrate. The microchannels provide ingress and egress paths for a refrigerant.

Baumann, Theodore F.↗

Water cooling system for an air-breathing hypersonic test vehicle

This study provides concepts for hypersonic experimental scramjet test vehicles which have low cost and low risk. Cryogenic hydrogen is used as the fuel and coolant. Secondary water cooling systems were designed. Three concepts are shown: an all hydrogen cooling system, a secondary open loop water cooled system, and a secondary closed loop water cooled system. The open loop concept uses high pressure helium (15,000 psi) to drive water through the cooling system while maintaining the pressure in the water tank. The water flows through the turbine side of the turbopump to pump hydrogen fuel. The water is then allowed to vent. In the closed loop concept high pressure, room temperature, compressed liquid water is circulated. In flight water pressure is limited to 6000 psi by venting some of the water. Water is circulated through cooling channels via an ejector which uses high pressure gas to drive a water jet. The cooling systems are presented along with finite difference steady-state and transient analysis results. The results from this study indicate that water used as a secondary coolant can be designed to increase experimental test time, produce minimum venting of fluid and reduce overall development cost.

Petley, Dennis H.↗

A fuselage/tank structure study for actively cooled hypersonic cruise vehicles: Active cooling system analysis

The effects of fuselage cross section and structural arrangement on the performance of actively cooled hypersonic cruise vehicles are investigated. An active cooling system which maintains the aircraft's entire surface area at temperatures below 394 K at Mach 6 is developed along with a hydrogen fuel tankage thermal protection system. Thermodynamic characteristics of the actively cooled thermal protection systems established are summarized. Design heat loads and coolant flowrate requirements are defined for each major structural section and for the total system. Cooling system weights are summarized at the major component level. Conclusions and recommendations are included.

Stone, J. E.↗