Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlated double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.

Source record↗

A CCD System for Photometry of Direct and Spectroscopic Images

A charge-coupled device (CCD) for direct imagery at the focus of a ground-based telescope and for high dispersion spectroscopy of stars is evaluated. The CCD is an RCA SID 53612 thinned, buried channel array of 512x320 30-micron square pixels that are back-illuminated and refrigerated to about -60 C in a rugged, RF-shielded vacuum housing. The double-correlated sampling (integrator) readout system, the Z80 microprocessor readout control system, and the data collection system are described. The readout noise is 120 electron-hole pairs (ehp) per pixel per readout, the thermal dark current is 50 ehp/pixel/sec, and the scale of the 12-bit analog-to-digital converter is 25 ehp/AD unit. Unique features of this system are compared to other astronomical implementations of the same model of CCD.

Frecker, J. E.↗

IRAC test report. Gallium doped silicon band 2: Read noise and dark current

A direct readout infrared detector array, a candidate for the Space Infrared Telescope Facility (SIRTF) Infrared Array Camera (IRAC), has been tested. The array has a detector surface of gallium doped silicon, bump bonded to a 58x62 pixel MOSFET multiplexer on a separate chip. Although this chip and system do not meet all the SIRTF requirements, the critically important read noise is within a factor of 3 of the requirement. Significant accomplishments of this study include: (1) development of a low noise correlated double sampling readout system with a readout noise of 127 to 164 electrons (based on the detector integrator capacitance of 0.1 pF); (2) measurement of the readout noise of the detector itself, ranging from 123 to 214 electrons with bias only (best to worst pixel), and 256 to 424 electrons with full clocking in normal operation at 5.4 K where dark current is small. Thirty percent smaller read noises are obtained at a temperature of 15K; (3) measurement of the detector response versus integration time, showing significant nonlinear behavior for large signals, well below the saturation level; and (4) development of a custom computer interface and suitable software for collection, analysis and display of data.

Lamb, Gerald↗

Analysis and Enhancement of Low-Light-Level Performance of Photodiode-Type CMOS Active Pixel Images Operated with Sub-Threshold Reset

Noise in photodiode-type CMOS active pixel sensors (APS) is primarily due to the reset (kTC) noise at the sense node, since it is difficult to implement in-pixel correlated double sampling for a 2-D array. Signal integrated on the photodiode sense node (SENSE) is calculated by measuring difference between the voltage on the column bus (COL) - before and after the reset (RST) is pulsed. Lower than kTC noise can be achieved with photodiode-type pixels by employing "softreset" technique. Soft-reset refers to resetting with both drain and gate of the n-channel reset transistor kept at the same potential, causing the sense node to be reset using sub-threshold MOSFET current. However, lowering of noise is achieved only at the expense higher image lag and low-light-level non-linearity. In this paper, we present an analysis to explain the noise behavior, show evidence of degraded performance under low-light levels, and describe new pixels that eliminate non-linearity and lag without compromising noise.

Pain, Bedabrata↗

Ionizing Radiation Effects on Hole Collection Backside-Illuminated P-Type Deep-Trench Pinned Photo-MOS Pixels under Image Acquisition

Dark current degradation, origins, and annealing behavior after x-ray irradiation are studied in a P-type, hole collecting, backside-illuminated image sensor currently being developed at STMicroelectronics and based on deep-trenched photo-MOS pixels. Different biasing conditions during irradiation, i.e. grounded or biased and sequenced, are compared. The dark current increase with total ionizing dose (TID) and the dark current annealing behavior seem to be driven by the backside interface between the P-epitaxy of the pixels and the ONO stack. Despite still being under development, this pixel architecture already exhibits both very good electro-optical performance and a better radiation hardness than pinned photodiode-based CMOS Image sensors that benefit from the same advanced CIS processing technologies. At high total dose range, the photogate challenges custom Radiation-Hardened-by-Design photodiodes by exhibiting a comparable radiation tolerance while bringing new features such as high-resolution or Correlated Double Sampling.

CMOS Image Sensor (CIS)↗

A back-illuminated megapixel CMOS image sensor

In this paper, we present the test and characterization results for a back-illuminated megapixel CMOS imager. The imager pixel consists of a standard junction photodiode coupled to a three transistor-per-pixel switched source-follower readout [1]. The imager also consists of integrated timing and control and bias generation circuits, and provides analog output. The analog column-scan circuits were implemented in such a way that the imager could be configured to run in off-chip correlated double-sampling (CDS) mode. The imager was originally designed for normal front-illuminated operation, and was fabricated in a commercially available 0.5 pn triple-metal CMOS-imager compatible process. For backside illumination, the imager was thinned by etching away the substrate was etched away in a post-fabrication processing step.

Complementary Metal Oxide Semiconductor imager (CM↗

Electronic Still Camera

A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.

Holland, S. Douglas↗

A radiation-hard, low-background multiplexer design for spacecraft imager applications

A possible multiplexer design for the focal plane for the Cassini Visible and Infrared Mapping Spectrometer (VIMS) is reviewed. The instrument's requirements for the multiplexed array are summarized. The VIMS instrument has a modest radiation-hardness requirement due to the trajectory and planetary environments in which the instrument will be required to operate. The total ionizing dose hardness requirement is a few tens of kilorads. A thin-gate oxide of a few hundred angstroms thickness is to be used. Field hardness is to be achieved by guard bands or hardened dielectric isolation. The design is argued to meet the low-noise and radiation-hardness required for imaging at Saturn. The design is versatile enough to provide double-correlated and double-uncorrelated sampling, which is accomplished in the signal processing electronics outside the focal plane.

Staller, Craig↗

CCD correlated quadruple sampling processor

A correlated quadruple sampling processor for improved signal-to-noise ratio in the output of a charge-coupled device (CCD) is comprised of: switching means for momentarily clamping a CCD signal line at a first reference level A before a CCD data pulse and then obtaining a first data sample B with respect to the reference A during a CCD data pulse, and storing the positive sample B-A; switching means for momentarily clamping the CCD signal line a second time at the level C during the presence of the CCD data pulse and then obtaining a second data sample D with respect to the reference level C after the CCD data pulse, and storing the negative sample D-C; and means for obtaining the difference between the stored samples +(B-A) and -(D-C), thus increasing the net signal amplitude by a factor of about 2 while the noise would be increased by only a factor of square root of 2 since there will be no correlation in the noise between the double samples +(B-A) and -(D-C) effectively added.

Gaalema, S. D.↗

Forecasting Coronal Mass Ejections from Magnetograms

We report further results from our ongoing assessment of magnetogram-based measures of active-region nonpotentiality (magnetic shear and twist) and size as predictors of coronal mass ejections (CMEs). From a set of 36 vector magnetograms of bipolar active regions (Falconer, Moore, & Gary 2004, ApJ, submitted), we have found that (1) each of our 5 measures of active-region nonpotentiality has a 75-80% success rate in predicting whether an active region will produce a CME within 2 days after the magnetogram, (2) the correlation of each of these measures with CME production in this window is statistically significant (confidence level greater than 95%), (3) our measure of active-region size has a 65% success rate in predicting CMEs in this window, but (4) the correlation between active-region size and CME productivity is not statistically significant (confidence level approximately 80%). As part of the work under our pending 2003 LWS TR&T proposal, we will double our sample to approximately 70 active regions in order to demonstrate a statistically significant correlation between active-region size and CME productivity, and to determine whether this correlation is a byproduct of any Sun-produced correlation between magnetic twist and size of active regions. Since the 2002 LWS Science Workshop, we have found a measure of active-region nonpotentiality (the length of strong-gradient neutral line) that can be measured from a line-of-sight magnetogram, and we have generalized this measure and the corresponding measure from a vector magnetogram (the length of strong-shear neutral line) so that they can be applied to multiple-bipole complex active regions as well as to bipolar active regions. Preliminary results will be presented from application of these two generalized measures to our sample of bipolar active regions and to a new sample of multiple-bipole active regions.

Falconer, D. A.↗

Range vegetation type mapping and above-ground green biomass estimations using multispectral imagery

The author has identified the following significant results. Range vegetation types have been successfully mapped on a portion of the 68,000 acre study site located west of Baggs, Wyoming, using ERTS-1 imagery. These types have been ascertained from field transects over a five year period. Comparable studies will be made with EREP imagery. Above-ground biomass estimation studies are being conducted utilizing double sampling techniques on two similar study sites. Information obtained will be correlated with percent relative reflectance measurements obtained on the ground which will be related to image brightness levels. This will provide an estimate of above-ground green biomass with multispectral imagery.

Houston, R. S.↗

Estimating acreage by double sampling using LANDSAT data

Double sampling techniques employing LANDSAT data for estimating the acreage of corn and soybeans was investigated and evaluated. The evaluation was based on estimated costs and correlations between two existing procedures having differing cost/variance characteristics, and included consideration of their individual merits when coupled with a fictional 'perfect' procedure of zero bias and variance. Two features of the analysis are: (1) the simultaneous estimation of two or more crops; and (2) the imposition of linear cost constraints among two or more types of resource. A reasonably realistic operational scenario was postulated. The costs were estimated from current experience with the measurement procedures involved, and the correlations were estimated from a set of 39 LACIE-type sample segments located in the U.S. Corn Belt. For a fixed variance of the estimate, double sampling with the two existing LANDSAT measurement procedures can result in a 25% or 50% cost reduction. Double sampling which included the fictional perfect procedure results in a more cost effective combination when it is used with the lower cost/higher variance representative of the existing procedures.

Pont, F.↗

Forecasting Coronal Mass Ejections from Vector Magnetograms

In a 17 vector magnetogram study of 12 bipolar active regions (Falconer, Moore, & Gary, 2002, ApJ in press), we correlated four quantitative global magnetic measures with the Coronal Mass Ejections (CME) productivity of the active region. The global measures included a measure of active region size, the total magnetic flux phi and three measures of an active region global nonpotentiality 1) the net current (I (sub N)), 2) the length of the strong-shear, strong-field main neutral line (L(sub SS)) and 3) and the normalized twist (alpha = muIN/PHI). The CME productivity was determined from YOHKOH/SXT observations, Geostationary Operational Environmental Satellite (GOES), and when possible Solar and Heliospheric Observatory/Large Angle and Spectrometric Coronagraph Experiment (SOHO/LASCO) observations within 12 days of the day of the magnetogram. We found that the three measures of global nonpotentiality (I(sub N), L(sub SS), alpha) were all well correlated (greater than 99% confidence level) with an active region's CME productivity. The sample size was to small to confirm if there was a statistical significant correlation of the globally nonscientist measures with future CME activity (i.e. from the date of the magnetogram forward). We are doubling our sample, and will report on the statistical significance of global nonpotentiality as a predictor of future CME productivity. The new active regions are all from the first year of the upgraded MSFC vector magnetograms. This work, is funded by NSF through the Space Weather Program, by NASA through the Living with the Star, Targeted Research and Technology, and by NASA Solar Physics Supporting Research and Technology Program. The upgrade to the MSFC vector magnetograph was supported by the High Energy Solar Spectroscopic Imager (HESSI) mission.

Falconer, D. A.↗

Crop identification and acreage measurement utilizing ERTS imagery

The author has identified the following significant results. Results of temporal overlays, equal and unequal prior probabilities, and independent test data are discussed. The amount of improvement that each technique contributed are summarized: (1) Results in Missouri where temporal overlays were made, show that temporal information improved the overall classification by 10%. (2) The dates were not optimum that were overlaid. (3) Data analysis in both Missouri and Idaho indicates that the use of prior probabilities improves the overall classification rates by at least 10% overusing the assumption that the crops are all equally likely. (4) Using both procedures together indicates that overall performance can be improved by 20% over one data and equal prior probabilities. (5) Idaho data has banding problems that may have caused serious problems in the crop classification. (6) The twelve crop types in Idaho seem to be quite similar spectrally, and hence, classification is quite difficult. (7) ERTS may not contain enough information to have perfect classification, but the data may still be useful for making crop acreage estimates. (8) Remotely sensed data could be used with a regression estimator if there is a correlation between ground data and classification results. (9) Remotely sensed data could be used with a double sample model.

Vonsteen, D. H.↗

An integrated study of earth resources in the state of California using remote sensing techniques

The author has identified the following significant results. A weighted stratified double sample design using hardcopy LANDSAT-1 and ground data was utilized in developmental studies for snow water content estimation. Study results gave a correlation coefficient of 0.80 between LANDSAT sample units estimates of snow water content and ground subsamples. A basin snow water content estimate allowable error was given as 1.00 percent at the 99 percent confidence level with the same budget level utilized in conventional snow surveys. Several evapotranspiration estimation models were selected for efficient application at each level of data to be sampled. An area estimation procedure for impervious surface types of differing impermeability adjacent to stream channels was developed. This technique employs a double sample of 1:125,000 color infrared hightflight transparency data with ground or large scale photography.

Colwell, R. N.↗

A homogeneous sample of binary galaxies: Basic observational properties

A survey of optical characteristics for 585 binary systems, satisfying a condition of apparent isolation on the sky, is presented. Influences of various selection effects distorting the average parameters of the sample are noted. The pair components display mutual similarity over all the global properties: luminosity, diameter, morphological type, mass-to-luminosity ratio, angular momentum etc., which is not due only to selection effects. The observed correlations must be caused by common origin of pair members. Some features (nuclear activity, color index) could acquire similarity during synchronous evolution of double galaxies. Despite the observed isolation, the sample of double systems is seriously contaminated by accidental pairs, and also by members of groups and clusters. After removing false pairs estimates of orbital mass-to-luminosity ratio range from 0 to 30 f(solar), with the mean value (7.8 plus or minus 0.7) f(solar). Binary galaxies possess nearly circular orbits with a typical eccentrity e = 0.25, probably resulting from evolutionary selection driven by component mergers under dynamical friction. The double-galaxy population with space abundance 0.12 plus or minus 0.02 and characteristic merger timescale 0.2 H(exp -1) may significantly influence the rate of dynamical evolution of galaxies.

Karachentsev, I. D.↗

An X-ray survey of a complete sample of 3CR radio galaxies

The X-ray survey of the galaxies, 40 in all, was made with the Einstein Observatory. By comparing the distributions of X-ray luminosities, it is found that 3CR galaxies with double radio morphology (FR 2) and optical emission-line spectra tend to be the more powerful X-ray emitters, with broad-line galaxies at the top of the distribution. It is also found that the X-ray luminosity is strongly correlated with the 5 GHz radio nuclear luminosity. Through an analysis of the complete optical and radio sample with the Spearman partial rank correlation technique, it is determined that nuclear radio luminosity at 5 GHz is correlated with both total radio luminosity at 178 MHz and with galaxy optical luminosity. Other weaker correlations are found of the X-ray luminosity with the total radio luminosity at 178 MHz and the optical luminosity of the galaxy. The results are seen as underlining the importance of nuclear phenomena in radio galaxies and indicating a nuclear origin of their X-ray emission. In addition, it is found that the 3CR emission-line galaxies are similar to both Seyfert galaxies and quasars with double radio morphology in their X-ray properties, strongly reinforcing a unified picture of active nuclei.

Fabbiano, G.↗