Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlated double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Spatially resolved gas and stellar kinematics in compact starburst galaxies

The kinematics of galaxies provide valuable insights into their physics and assembly history. Kinematics are governed not only by the gravitational potential, but also by merger events and stellar feedback processes such as stellar winds and supernova explosions. We aim to identify what governs the kinematics in a sample of SDSS-selected nearby starburst galaxies, by obtaining spatially resolved measurements of the gas and stellar kinematics. We obtained near-infrared integral-field K-band spectroscopy with VLT/SINFONI for 15 compact starburst galaxies. We derived the integrated as well as spatially resolved stellar and gas kinematics. The stellar kinematics were derived from the CO absorption bands, and Paα and Brγ emission lines were used for the gas kinematics. Based on the integrated spectra, we find that the majority of galaxies have gas and stellar velocity dispersion that are comparable. A spatially resolved comparison shows that the six galaxies that deviate show evidence for a bulge or stellar feedback. Two galaxies are identified as mergers based on their double-peaked emission lines. In our sample, we find a negative correlation between the ratio of the rotational velocity over the velocity dispersion (v rot /σ) and the star formation rate surface density. We propose a scenario where the global kinematics of the galaxies are determined by gravitational instabilities that affect both the stars and gas. This process could be driven by mergers or accretion events. Effects of stellar feedback on the ionised gas are more localised and detected only in the spatially resolved analysis. The mass derived from the velocity dispersion provides a reliable mass even if the galaxy cannot be spatially resolved. The technique used in this paper is applicable to galaxies at low and high redshift with the next generation of infrared-focussed telescopes (JWST and ELT).

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning the microscopic form of nematic order in twisted double-bilayer graphene

Modern scanning probe techniques, such as scanning tunneling microscopy, provide access to a large amount of data encoding the underlying physics of quantum matter. In this work, we show how convolutional neural networks can be used to learn effective theoretical models from scanning tunneling microscopy data on correlated moiré superlattices. Moiré systems are particularly well suited for this task as their increased lattice constant provides access to intra-unit-cell physics, while their tunability allows for the collection of high-dimensional data sets from a single sample. Using electronic nematic order in twisted double-bilayer graphene as an example, we show that incorporating correlations between the local density of states at different energies allows convolutional neural networks not only to learn the microscopic nematic order parameter, but also to distinguish it from heterostrain. These results demonstrate that neural networks are a powerful method for investigating the microscopic details of correlated phenomena in moiré systems and beyond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An efficient random-sampling method for calculating double occupancy of Gutzwiller wave function in single-band 1D and 2D lattices

In this paper, we report a random sampling method for computing the expectation value of physical quantities based on the Gutzwiler variational wave function. As the first application, we calculated the double occupancy, which is a critical quantity for under- standing the correlation effects in many-body systems, for single-band 1D and 2D lattices. We demonstrated that the random sampling scheme is more efficient than an existing Metropolis Monte-Carlo algorithm. For the 1D Hubbard model with only nearest-neighbor hopping, our results are almost identical to the exact analytic solution. We have also studied systems to which analytic solutions are not available, including the 1D lattices with next-nearest-neighbor hopping and 2D lattices. In addition, constraints on real-space con gurations can be easily implemented in the current scheme to further improve the Gutzwiller wave function. As an example, we calculated the double occupancy for 1D Hubbard model by applying the constraint that all double-occupied sites are paired with an empty site. With enhanced correlation between double-occupied and empty sites, the constraint results in much improved ground-state energy for 1D Hubbard model with strong on-site repulsion.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nearly hyperuniform, nonhyperuniform, and antihyperuniform density fluctuations in two-dimensional transition metal dichalcogenides with defects

Hyperuniform many-body systems in d-dimensional Euclidean space R d are characterized by completely suppressed (normalized) infinite-wavelength density fluctuations, and appear to be endowed with novel exotic physical properties. Recently, hyperuniform systems of disordered varieties have been observed in the context of various atomic-scale two-dimensional (2D) materials. Here, we analyze the effects of localized defects on the density fluctuations across length scales and on the hyperuniformity property of experimental samples of two-dimensional transition metal dichalcogenides. In particular, we extract atomic coordinates from time series annular dark field-scanning transmission electron microscopy (ADF-STEM) imaging data of 2D tungsten chalcogenides with the 2H structure (Te-doped 2H-WSe 2 ) showing continuous development and evolution of electron-beam induced defects, and construct the corresponding chemical-bonding informed coordination networks between the atoms. We then compute a variety of pair statistics and bond-orientational statistics to characterize the samples. At low defect concentrations, the corresponding materials are nearly hyperuniform, characterized by significantly suppressed scattering at the zero wave-number limit (omitting forward/ballistic scattering). As more defects are introduced, the (approximate) hyperuniformity of the materials is gradually destroyed, and the system becomes non-hyperuniform even when the material still contains a significant amount of crystalline regions. At high defect concentrations, the structures become antihyperuniform with diverging (normalized) large-scale density fluctuations, mimicking those typically observed at the thermal critical points associated with phase transitions. Overall, the defected materials possess varying degrees of orientation order, and there is apparently no intermediate hexatic phase emerging. To understand the observed nearly hyperuniform density fluctuations in the slightly defected materials, we construct a minimalist structural model and demonstrate that the experimental samples can be essentially viewed as perturbed honeycomb crystals with small correlated displacements and double chalcogen vacancies. Moreover, the small correlated displacements alone can significantly degrade hyperuniformity of the perfect honeycomb structure. Therefore, even a small amount of vacancies, when coupled with correlated displacements, can completely destroy hyperuniformity of the system.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ab Initio Many Body Quantum Embedding and Local Correlation in Crystalline Materials using Interpolative Separable Density Fitting

We present an efficient implementation of ab initio many-body quantum embedding and local correlation methods for infinite periodic systems through translational symmetry adapted interpolative separable density fitting, an approach which reduces the scaling of the calculations to only linear with the number of k-points. Employing this methodology, we compute correlated ground-state coupled cluster energies within density matrix embedding and local natural orbital correlation frameworks for both weakly and strongly correlated solids, using up to 1000 k-points. By extrapolating the local correlation domains and k-point sampling we further obtain estimates of the full coupled cluster with singles, doubles, and perturbative triples ground-state energies in the thermodynamic limit.

Chemical Physics (physics.chem-ph)↗

Robust long-range magnetic correlation across antiphase domain boundaries in Sr 2 CrReO 6

Here, we report a resonant elastic x-ray scattering study of a thin-film sample of Sr 2 CrReO 6 , which has one of the highest ferrimagnetic transition temperatures among ordered double perovskites.We found resonantly enhanced magnetic Bragg peaks at Q = (odd, odd, odd) at both the rhenium L 2 and L 3 edges, which coincide with the structural Bragg peaks of Sr 2 CrReO 6 . By analyzing the widths of these Bragg peaks, we extracted very different structural and magnetic correlation lengths. The former is about 15 nm, while the latter is constrained by the instrumental resolution to be at least 90 nm. We argue that a finite structural correlation length is consistent with the existence of antiphase nanodomains in our sample. On the other hand, a much larger magnetic correlation length indicates that the magnetic correlation extends far beyond the boundaries of individual domains and is consistent with strong antiferromagnetic coupling between different antiphase domains. Last, from the azimuthal dependence of the magnetic intensity, we show that the magnetic moments lie perpendicular to the c axis, which explains the earlier bulk magnetization data.

36 MATERIALS SCIENCE↗

The Effect of Geometry, Spin, and Orbital Optimization in Achieving Accurate, Correlated Results for Iron–Sulfur Cubanes

Iron–sulfur clusters comprise an important functional motif in the catalytic centers of biological systems, capable of enabling important chemical transformations at ambient conditions. This remarkable capability derives from a notoriously complex electronic structure that is characterized by a high density of states that is sensitive to geometric changes. The spectral sensitivity to subtle geometric changes has received little attention from correlated, large active space calculations, owing partly to the exceptional computational complexity for treating these large and correlated systems accurately. Here, to provide insight into this aspect, we report the first Complete Active Space Self Consistent Field (CASSCF) calculations for different geometries of the [Fe(II/III) 4 S 4 (SMe) 4 ] -2 clusters using two complementary, correlated solvers: spin-pure Adaptive Sampling Configuration Interaction (ASCI) and Density Matrix Renormalization Group (DMRG). We find that the previously established picture of a double-exchange driven magnetic structure, with minute energy gaps (<1 mHa) between consecutive spin states, has a weak dependence on the underlying geometry. However, the spin gap between the singlet and the spin state 2S + 1 = 19, corresponding to a maximal number of Fe-d electrons being unpaired and of parallel spin, is strongly geometry dependent, changing by a factor of 3 upon slight deformations that are still within biologically relevant parameters. The CASSCF orbital optimization procedure, using active spaces as large as 86 electrons in 52 orbitals, was found to reduce this gap compared to typical mean-field orbital approaches. Our results show the need for performing large active space calculations to unveil the challenging electronic structure of these complex catalytic centers and should serve as accurate starting points for fully correlated treatments upon inclusion of dynamical correlation outside the active space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing host DNA contamination in 16S rRNA gene surveys of anthozoan microbiomes using PNA clamps

Efforts to study the microbial communities associated with corals can be limited by inefficiencies in the sequencing process due to high levels of host amplification by universal bacterial 16S rRNA gene primers. Here, we develop an inexpensive peptide nucleic acid (PNA) clamp that binds to a target sequence of host DNA during PCR and blocks amplification. We then test the ability of this PNA clamp to mitigate host contamination and increase overall microbial sequence coverage on samples from three coral species: the gorgonians Eunicea flexuosa and Gorgonia ventalina, and the scleractinian Porites panamensis. The 20-bp PNA clamp was designed using DNA from E. flexuosa. Adding the PNA clamp during PCR increased the percentage of microbial reads in E. flexuosa samples more than 11-fold. Microbial community diversity was similar without- and with-PNA clamps, as were the relative frequencies of the ten most abundant ASVs (amplicon sequence variants), indicating that the clamps successfully blocked host DNA amplification while simultaneously increasing microbial DNA amplification proportionally across the most abundant taxa. The reduction of E. flexuosa DNA correlated with an increase in the abundance of rarer taxa. The clamp also increased the average percentage of microbial reads in another gorgonian, G. ventalina, by 8.6-fold without altering the microbial community beta diversity, and in a distantly related scleractinian coral, P. panamensis, by nearly double. The reduction of host contamination correlated with the number of nucleotide mismatches between the host amplicon and the PNA clamp. The PNA clamp costs as little as $0.48 per sample, making it an efficient and cost-effective solution to increase microbial sequence coverage for high-throughput sequencing of coral microbial communities.

16S rRNA gene sequencing↗

UFCC Calibration Measurements for Bulk U 3 O 8 Powder Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF 6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. The sample enrichments varied from 0.72% to 91% to establish the shape of the calibration curve and the measurement uncertainties. The measurements included the singles, doubles, and triples rates. The time correlations between the 252 Cf source and the induced fission reactions reduced the statistical error in the doubles and triples rates to be small enough for useful measurements in 5-10 minutes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing DNA structural heterogeneity by identifying conformational subensembles of a bicovalently bound cyanine dye

DNA is a re-configurable, biological information-storage unit, and much remains to be learned about its heterogeneous structural dynamics. For example, while it is known that molecular dyes templated onto DNA exhibit increased photostability, the mechanism by which the structural dynamics of DNA affect the dye photophysics remains unknown. Here, we use femtosecond, two-dimensional electronic spectroscopy measurements of a cyanine dye, Cy5, to probe local conformations in samples of single-stranded DNA (ssDNA–Cy5), double-stranded DNA (dsDNA–Cy5), and Holliday junction DNA (HJ–DNA–Cy5). A line shape analysis of the 2D spectra reveals a strong excitation–emission correlation present in only the dsDNA–Cy5 complex, which is a signature of inhomogeneous broadening. Molecular dynamics simulations support the conclusion that this inhomogeneous broadening arises from a nearly degenerate conformer found only in the dsDNA–Cy5 complex. These insights will support future studies on DNA’s structural heterogeneity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thin-film chemical expansion of ceria based solid solutions: laser vibrometry study

The chemical expansion of Pr 0.1 Ce 0.9 O 2-δ (PCO) and CeO 2-δ thin films is investigated in the temperature range between 600 °C and 800 °C by laser Doppler vibrometry (LDV). It enables non-contact determination of nanometer scale changes in film thickness at high temperatures. The present study is the first systematic and detailed investigation of chemical expansion of doped and undoped ceria thin films at temperatures above 650 °C. The thin films were deposited on yttria stabilized zirconia substrates (YSZ), operated as an electrochemical oxygen pump, to periodically adjust the oxygen activity in the films, leading to reversible expansion and contraction of the film. This further leads to stresses in the underlying YSZ substrates, accompanied by bending of the overall devices. Film thickness changes and sample bending are found to reach up to 10 and several hundred nanometers, respectively, at excitation frequencies from 0.1 to 10 Hz and applied voltages from 0–0.75 V for PCO and 0–1 V for ceria. At low frequencies, equilibrium conditions are approached. As a consequence maximum thin-film expansion of PCO is expected due to full reduction of the Pr ions. The lower detection limit for displacements is found to be in the subnanometer range. At 800 °C and an excitation frequency of 1 Hz, the LDV shows a remarkable resolution of 0.3 nm which allows, for example, the characterization of materials with small levels of expansion, such as undoped ceria at high oxygen partial pressure. As the correlation between film expansion and sample bending is obtained through this study, a dimensional change of a free body consisting of the same material can be calculated using the high resolution characteristics of this system. A minimum detectable dimensional change of 5 pm is estimated even under challenging high-temperature conditions at 800 °C opening up opportunities to investigate electro-chemo-mechanical phenomena heretofore impossible to investigate. The expansion data are correlated with previous results on the oxygen nonstoichiometry of PCO thin films, and a defect model for bulk ceria solid solutions is adopted to calculate the cation and anion radii changes in the constrained films during chemical expansion. The constrained films exhibit anisotropic volume expansion with displacements perpendicular to the substrate plane nearly double that of bulk samples. The PCO films used here generate high total displacements of several 100 nm’s with high reproducibility. Consequently, PCO films are identified to be a potential core component of high-temperature actuators. They benefit not only from high displacements at temperatures where most piezoelectric materials no longer operate while exhibiting, low voltage operation and low energy consumption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗