Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlated systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Review of image correlation systems - Hybrid and optical

The operating principles, design, and development histories of three image correlation systems, the Portable Correlator Unit (PCU), the Miniature Correlator Unit (MCU), and the Coherence Interferometer (CI) are reviewed. The PCU and MCU are compact versions of the classical Vander Lught filter optical correlator, essentially parallel optical processors by light valve; the CI is a white-light correlator which functions entirely by interfering light waves, with electronic detection only at the final output, and thus represents a parallel optical processor by rotational-shear interferometer. Details of the design and construction are discussed and illustrated with drawings and photographs. Also considered are applications of the MCU to NASA tasks such as rendezvous and docking on the Mars Rover and Sample Return mission, autonomous robotic exploration of planetary surfaces, and compression and pattern-recognition of remote-sensing data.

Breckinridge, James B.↗

Joint-transform correlator systems using deformable-mirror spatial light modulators

Two joint-transform correlator systems based on deformable-mirror-device (DMD) spatial light modulators and CCD video cameras are described. The system designs provide for real-time correlation between video-formatted input scenes and stored reference images. The DMD light modulators are used exclusively for inputting data in the optical stages of these systems, and the CCD cameras are used to provide the critical square-law detection required in joint-transform achitectures. Experimental verification of the functionality of these DMD/CCD joint-transform systems is also presented.

Florence, James M.↗

A theoretical analysis of the MSFC holographic correlation system

A theoretical analysis was completed for the correlation output signal for the MSFC holographic correlation filtering system. Under appropriate assumptions, the correlation output was derived as a function of the roughness of the tested surface, the displacement of the illuminated area of the test surface, the characteristics of the optical components used in the system, and the system configuration. In addition, an approximate relationship between the displacement of the detected signal (which is focused on the photomultiplier tube) and the displacement of the illuminated area on the test surface was also derived.

Liu, H. K.↗

Developing new architectures for the Block 2 VLBI correlator system

The overall LSI (large-scale integrated circuits) architecture design and current status of the VBLI (very long baseline interferometry) block 2 correlator is addressed. The VBLI correlator algorithms demand a computing system that provides a throughput of hundreds of millions of instructions per second to perform cross-correlation detection for six baselines. The LSI technology lights the way for the computation of complex parallel process and is raising the upper bound of computerization.

Peterson, J. C.↗

Problems in correlation caused by propulsion systems

Correlation efforts and selected results for transonic drag are reviewed. A process to reduce the typical error sources to decrease the errors inherent in the transonic aircraft development process is summarized.

Smith, R. H.↗

Survey of current correlators and applications

With this summary an attempt is made to contact as many users as possible so as to provide summary data on correlation systems, both in use and as planned. Data on currently available very large scale integration (VLSI) chips and complete systems are included. Also, several planned correlator systems are described and summarized in tabular form. Finally, a description is given of the work being done in the Communications Systems Research Section on VLSI correlator chips and complete correlator systems.

Lahmeyer, C. R.↗

An inter-comparison of surface energy flux measurement systems used during FIFE, 1987

During the first International Satellite Land Surface Climatology Program Field Experiment (FIFE-87), surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to nearly all the flux stations to serve as a reference for estimating the instrument related differences. The rover system was installed within a few meters from the host instrument of a site. Net radiation, Bowen ratio, and latent heat fluxes were compared between the rover and the host for the stations visited. Linear regression analysis was used to examine the relationship between rover measurements and host measurements. These inter-comparisons are needed to examine the influence of instrumentation on measurement uncertainty. Highly significant effects of instrument type were detected from these comparisons. Instruments of the same type showed average differences of less than 5 percent for net radiation, 10 percent for Bowen ratio, and 6 percent for latent heat flux. The corresponding average differences for different types of instruments can be up to 10, 30, and 20 percent respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected REBS model. The 4-way components methed and the Thornswaite type give similar values to the REBS. The SERBS type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the AZET systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems.

Nie, D.↗

An intercomparison of surface energy flux measurement systems used during FIFE 1987

During FIFE 1987, surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to 20 of the flux stations to serve as a reference for estimating the instrument-related differences. The rover system was installed within a few meters from the host instrument of a site. Using linear regression analysis, net radiation, Bowen ratio, and latent heat fluxes were compared between the rover measurements and the host measurements. The average differences in net radiation, Bowen ratio, and latent heat flux from different types of instruments can be up to 10, 30, and 20 percent, respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected radiation energy balance system (REBS) model. The four-way components method and the Thornthwaite type give similar values to the REBS. The surface energy radiation balance systems type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the arid zone evapotranspiration systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems. It is recommended that users of the flux data take these differences into account.

Nie, D.↗

Viscous-flow analysis of a subsonic transport aircraft high-lift system and correlation with flight data

High-lift system aerodynamics has been gaining attention in recent years. In an effort to improve aircraft performance, comprehensive studies of multi-element airfoil systems are being undertaken in wind-tunnel and flight experiments. Recent developments in Computational Fluid Dynamics (CFD) offer a relatively inexpensive alternative for studying complex viscous flows by numerically solving the Navier-Stokes (N-S) equations. Current limitations in computer resources restrict practical high-lift N-S computations to two dimensions, but CFD predictions can yield tremendous insight into flow structure, interactions between airfoil elements, and effects of changes in airfoil geometry or free-stream conditions. These codes are very accurate when compared to strictly 2D data provided by wind-tunnel testing, as will be shown here. Yet, additional challenges must be faced in the analysis of a production aircraft wing section, such as that of the NASA Langley Transport Systems Research Vehicle (TSRV). A primary issue is the sweep theory used to correlate 2D predictions with 3D flight results, accounting for sweep, taper, and finite wing effects. Other computational issues addressed here include the effects of surface roughness of the geometry, cove shape modeling, grid topology, and transition specification. The sensitivity of the flow to changing free-stream conditions is investigated. In addition, the effects of Gurney flaps on the aerodynamic characteristics of the airfoil system are predicted.

Potter, R. C.↗

Conserving approximations for strongly correlated electron systems - Bethe-Salpeter equation and dynamics for the two-dimensional Hubbard model

A semianalytical approach is described for strongly correlated electronic systems which satisfies microscopic conservation laws, treats strong frequency and momentum dependences, and provides information on both static and dynamic properties. This approach may be used to treat large systems and temperatures lower than those currently accessible to finite-temperature quantum Monte Carlo techniques. Examples of such systems include heavy-electron compounds, organic Bechegaard salts, bis-(ethylenedithiolo)-TTF superconductors, and the oxide superconductors. The technique is based on the derivation and self-consistent solution of infinite-order conserving approximations. The technique is used to derive a low-temperature phase diagram and dynamic correlation functions for the two-dimensional Hubbard lattice model.

Bickers, N. E.↗

Mark 3 correlator hardware and software

The Mark 3 correlator system is described in some detail. The correlator system is based on a modular philosophy. Each correlator module independently processes the data from one track pair. Therefore, 28 modules are necessary to complete a full one baseline processor and 84 modules for a full 3 baseline processor. Each correlator module has two interfaces: (1) data and clock from each of the two tracks to be correlated and (2) Computer Automated Measurement and Control (CAMAC) dataway interface to the computer. The processor is organized around the IEEE CAMAC standard architecture, housing 15 correlator modules in each of 6 crates. This allows one pass processing of a full 3 baseline 28 track observation or a 6 baseline (4 station) 14 track observation. The correlator architecture allows easy expansion for up to 8 stations. The computer system is an HP 1000 system utilizing a 16 bit minicomputer with disc and tape peripherals. The processing software is also organized in a modular fashion with many independent but cooperative programs controlling the operation of the Mark 3 processor. Processing time through the correlator is normally real time or faster, with graphics displays providing real time monitor and control of the processing operation.

Whitney, A. R.↗