Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhanced resolution particle size distributions by multiple angle photon correlation spectroscopy

Photon correlation spectroscopy (PCS) has become a method of choice for measuring submicrometer particles. It is capable of rapid, accurate measurements of mean particle size. Since the measurements are nonperturbing, it is ideal for monitoring systems undergoing dynamic changes. Despite its widespread acceptance, the information content of PCS measurements for particle size distributions is low and provides limited resolution. A method is presented whereby PCS measurements made at several scattering angles plus the angular distribution of light scattered from the particles are combined in a single simultaneous analysis to effect an enhanced resolution particle size distribution. The efficacy of the method is assessed by recovering size distributions from computer simulated data and by comparisons of conventional PCS measurements of polystyrene spheres with those made by the new method.

Bott, Steven E.↗

Measurements of Doppler shifts by gas correlation spectroscopy

IR gas correlation spectroscopy is a sensitive technique for the measurement of small Doppler shifts in spectra. This technique also exhibits several important advantages over alternative methods in the remote sensing of stratospheric and mesospheric winds from spacecraft. Attention is presently given to laboratory tests demonstrating gas correlation spectroscopy's quantitative measurement of small Doppler shifts in spectra, whose close agreement with theoretical predictions suggests that measurements of the change in the radiant flux through a gas correlation spectrometer can be used to measure the relative velocity between gas and instrument for a moving parcel of gas.

Mccleese, D. J.↗

Electrooptic phase modulation gas correlation spectroscopy - A laboratory demonstration

A new gas-correlation spectroscopy technique is described which uses electrooptic phase modulation (EOPM) of atmospheric emission spectra together with a reference cell to selectively detect radiatively active gases. Laboratory results demonstrate that the EOPM gas-correlation technique is a sensitive approach to species abundance measurements, and support the feasibility of an instrument for measurement of winds in the stratosphere and mesosphere using an EOPM. Through the measurement of wind-induced Doppler shifts in the spectra of atmospheric species, this instrument offers a means of monitoring the wind field in the 20-100 km altitude range from a satellite.

Rider, D. M.↗

Phase-Modulation Gas-Correlation Spectroscopy

Electro-optic phase-modulation gas-correlation spectroscopy demonstrated in laboratory tests promising candidate technique for remote sensing of gases, temperatures, and wind velocities in atmosphere. In technique radiation emitted by sample atmosphere passed through electro-optic phase modulator, and modulated and unmodulated versions of spectrum alternately passed through reference absorption cell containing gas to be detected. Radiation emerging from reference cell band-pass filtered and detected. Correlation signal is difference in intensity between phase-modulated and unmodulated detected signals.

Rider, David M.↗

Statistical fitting accuracy in photon correlation spectroscopy

Continuing our experimental investigation of the fitting accuracy associated with photon correlation spectroscopy, we collect 150 correlograms of light scattered at 90 deg from a thermostated sample of 91-nm-diameter, polystyrene latex spheres in water. The correlograms are taken with two correlators: one with linearly spaced channels and one with geometrically spaced channels. Decay rates are extracted from the single-exponential correlograms with both nonlinear least-squares fits and second-order cumulant fits. We make several statistical comparisons between the two fitting techniques and verify an earlier result that there is no sample-time dependence in the decay rate errors. We find, however, that the two fitting techniques give decay rates that differ by 1 percent.

Shaumeyer, J. N.↗

Active-passive correlation spectroscopy - A new technique for identifying ocean color algorithm spectral regions

A new active-passive airborne data correlation technique has been developed which allows the validation of existing in-water oceoan color algorithms and the rapid search, identification, and evaluation of new sensor band locations and algorithm wavelength intervals. Thus far, applied only in conjunction with the spectral curvature algorithm (SCA), the active-passive correlation spectroscopy (APCS) technique shows that (1) the usual 490-nm (center-band) chlorophyll SCA could satisfactorily be placed anywhere within the nominal 460-510-nm interval, and (2) two other spectral regions, 645-660 and 680-695 nm, show considerable promise for chlorophyll pigment measurement. Additionally, the APCS method reveals potentially useful wavelength regions (at 600 and about 670 nm) of very low chlorophyll-in-water spectral curvature into which accessory pigment algorithms for phycoerythrin might be carefully positioned. In combination, the APCS and SCA methods strongly suggest that significant information content resides within the seemingly featureless ocean color spectrum.

Hoge, F. E.↗

Two-Photon Fluorescence Correlation Spectroscopy

We will describe a two-photon microscope currently under development at the NASA Glenn Research Center. It is composed of a Coherent Mira 900 tunable, pulsed Titanium:Sapphire laser system, an Olympus Fluoview 300 confocal scanning head, and a Leica DM IRE inverted microscope. It will be used in conjunction with a technique known as fluorescence correlation spectroscopy (FCS) to study intracellular protein dynamics. We will briefly explain the advantages of the two-photon system over a conventional confocal microscope, and provide some preliminary experimental results.

Zimmerli, Gregory A.↗

Development of an Early Warning Fire Detection System using Correlation Spectroscopy

Combustion byproducts are numerous. A few examples of the gaseous byproducts include carbon dioxide, carbon monoxide, hydrogen chloride, hydrogen cyanide and ammonia. For detecting these chemical species, classic absorption spectroscopy has been used for many decades, but the sensitivity of steady-state methods is often unsuitable for the detection of trace compounds at the low levels (parts per million to parts per billion) appropriate for scientific purposes. This is particularly so for monitoring equipment, which must be compact and cost-effective, and which is often subjected to shock, vibration, and other environmental effects that can severely degrade the performance of high-sensitivity spectrometers in an aircraft. Steady-state techniques also suffer from a lack of specificity; the deconvolution of the spectra of complex mixtures is a laborious and error prone process. These problems are exacerbated in remote fiber-optic monitoring where, for practical reasons, the fundamental absorbance region of the spectrum (often between 3 and 8 microns) is inaccessible, and the low-strength, closely spaced, near-infrared overtone absorbance bands must be used. We circumvented these challenges by employing correlation spectroscopy, a variation of modulation spectroscopy.

Goswami, K.↗

Use of near infrared correlation spectroscopy for quantitation of surface iron, absorbed water and stored electronic energy in a suite of Mars soil analog materials

A number of questions concerning the surface mineralogy and the history of water on Mars remain unresolved using the Viking analyses and Earth-based telescopic data. Identification and quantitation of iron-bearing clays on Mars would elucidate these outstanding issues. Near infrared correlation analysis, a method typically applied to qualitative and quantitative analysis of individual constituents of multicomponent mixtures, is adapted here to selection of distinctive features of a small, highly homologous series of Fe/Ca-exchanged montmorillonites and several kalinites. Independently determined measures of surface iron, relative humidity and stored electronic energy were used as constituent data for linear regression of the constituent vs. reflectance data throughout the spectral region 0.68 to 2.5 micrometers. High correlations were found in appropriate regions for all three constituents, though that with stored energy is still considered tenuous. Quantitation was improved using 1st and 2nd derivative spectra. High resolution data over a broad spectral range would be required to quantitatively identify iron-bearing clays by remotely sensed reflectance.

Coyne, Lelia M.↗

Detecting the Onset of Fire in an Aircraft by Employing Correlation Spectroscopy

The cause of aircraft fire and locations of the fires are numerous. Worldwide, numerous in-flight fires have been passenger initiated, the prime location being the lavatory areas. Most in-flight fires in commercial carriers are of electrical origin and cigarettes. A cargo bay fire can be caused by a variety of reasons. The sheer number of different types of cargo makes it difficult to identify the origin, especially when the fire reaches the catastrophic level. The damage can be minimized, and fire can be suppressed effectively if a warning system for the onset of fire is available for onboard monitoring.

Goswami, Kisholoy↗

Miniature instrumentation for laser light scattering experiments

Traditional optical systems for photon correlation spectroscopy and laser anemometry have relied upon physically large and fairly expensive lasers, bulk-optics such as lenses of a few inches diameter, large mechanical mounts and carefully selected, fragile and bulky photon counting photomultiplier detectors. In some cases, experimental fluid dynamics at a desired position in a flow, perhaps deep inside complex machinery, is physically impossible or very difficult. Similar problems exist with photon correlation spectroscopy, e.g., remote and heterodyne experiments. Various optical and electro optical components were investigated and characterized with the aim of replacing existing photon correlation laser spectroscopy and anemometry techniques in miniaturized form, and with significant cost reduction. Very recently, a range of miniature, modular light scattering systems were constructed from little solid state optical and electro optical components, and experimentally verified measurement performance comparable to standard lab photon correlation spectroscopy and laser anemometry equipment.

Brown, Robert G. W.↗

Optical remote measurement of toxic gases

Enactment of the Clean Air Act Amendments (CAAA) of 1990 has resulted in increased ambient air monitoring needs for industry, some of which may be met efficiently using open-path optical remote sensing techniques. These techniques include Fourier transform spectroscopy, differential optical absorption spectroscopy, laser long-path absorption, differential absorption lidar, and gas cell correlation spectroscopy. With this regulatory impetus, it is an opportune time to consider applying these technologies to the remote and/or path-averaged measurement and monitoring of toxic gases covered by the CAAA. This article reviews the optical remote sensing technology and literature for that application.

Review↗

Photosynthetic accessory pigments - Evidence for the influence of phycoerythrin on the submarine light field

Upwelled water-leaving spectral radiances and the submarine light-field source are theorized to have the physical scattering and absorption effects of photosynthetic accessory pigments. A laser is employed to induce phycoerythrin pigment fluorescence, and the presence of the photosynthetic accessory pigment is measured in oceanic waters with a spectral fluorescence method. Experimental data from active-passive correlation spectroscopy demonstrate that water-leaving spectral radiances of about 600 nm are highly correlated with phycoerythrin pigment fluorescence. Because the data on the phycoerythrin and chlorophyll fluorescences are entered randomly in the correlation the results are considered unambiguous. An estimate of the photopigment is derived that agrees with measurements of its laser-induced fluorescence.

Hoge, Frank E.↗

Novel Optical Technique Developed and Tested for Measuring Two-Point Velocity Correlations in Turbulent Flows

A novel technique for characterizing turbulent flows was developed and tested at the NASA Glenn Research Center. The work is being done in collaboration with the University of Pittsburgh, through a grant from the NASA Microgravity Fluid Physics Program. The technique we are using, Homodyne Correlation Spectroscopy (HCS), is a laser-light-scattering technique that measures the Doppler frequency shift of light scattered from microscopic particles in the fluid flow. Whereas Laser Doppler Velocimetry gives a local (single-point) measurement of the fluid velocity, the HCS technique measures correlations between fluid velocities at two separate points in the flow at the same instant of time. Velocity correlations in the flow field are of fundamental interest to turbulence researchers and are of practical importance in many engineering applications, such as aeronautics.

Zimmerli, Gregory A.↗

Laser light scattering review

Since the development of laser light sources and fast digital electronics for signal processing, the classical discipline of light scattering on liquid systems experienced a strong revival plus an enormous expansion, mainly due to new dynamic light scattering techniques. While a large number of liquid systems can be investigated, ranging from pure liquids to multicomponent microemulsions, this review is largely restricted to applications on Brownian particles, typically in the submicron range. Static light scattering, the careful recording of the angular dependence of scattered light, is a valuable tool for the analysis of particle size and shape, or of their spatial ordering due to mutual interactions. Dynamic techniques, most notably photon correlation spectroscopy, give direct access to particle motion. This may be Brownian motion, which allows the determination of particle size, or some collective motion, e.g., electrophoresis, which yields particle mobility data. Suitable optical systems as well as the necessary data processing schemes are presented in some detail. Special attention is devoted to topics of current interest, like correlation over very large lag time ranges or multiple scattering.

Schaetzel, Klaus↗

Critical fluid light scattering

The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments were severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure fluctuation decay rates at least two decades closer to the critical point than is possible on earth, with a resolution of 3 microK. This will require loading the sample to 0.1 percent of the critical density and taking data as close as 100 microK to the critical temperature. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The experiment entails measurement of the scattering intensity fluctuation decay rate at two angles for each temperature and simultaneously recording the scattering intensities and sample turbidity (from the transmission). The analyzed intensity and turbidity data gives the correlation length at each temperature and locates the critical temperature. The fluctuation decay rate data from these measurements will provide a severe test of the generalized hydrodynamic theories of transport coefficients in the critical regions. When compared to equivalent data from binary liquid critical mixtures they will test the universality of critical dynamics.

Gammon, Robert W.↗

The Stratospheric and Mesospheric Sounder (SAMS) experiment

Thermal emission and solar resonance fluorescence from the atmospheric limb are reported. Global measurements are made of radiation from the molecular species. The gas correlation spectroscopy technique based on the use of gas cells to select emission from chosen spectral lines or from particular parts of spectral lines is used. The source function and departure from the thermodynamic equilibrium between 80 and 130 kilometers associated with CO2 emission bands were investigated. The zonal wind velocity component along the line of sight is measured.

Drummond, J. R.↗

Light scattering and dynamics of interacting Brownian particles

The relative motions of interacting Brownian particles in liquids may be described as radial diffusion in an effective potential of the mean force. By using a harmonic approximation for the effective potential, the intermediate scattering function may also be evaluated. For polystyrene spheres of 250 A mean radius in aqueous environment at 0.00125 g/cu cm concentration, the results for the calculated mean square displacement are in qualitative agreement with experimental data from photon correlation spectroscopy. Because of the interactions, the functions deviate considerably from the exponential forms for the free particles.

Tsang, T.↗