Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost effectiveness tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using Cost-Effectiveness Tests to Design CHP Incentive Programs

This paper examines the structure of cost-effectiveness tests to illustrate how they can accurately reflect the costs and benefits of CHP systems. This paper begins with a general background discussion on cost-effectiveness analysis of DER and then describes how cost-effectiveness tests can be applied to CHP. Cost-effectiveness results are then calculated and analyzed for CHP projects in five states: Arkansas, Colorado, Iowa, Maryland, and North Carolina. Based on the results obtained for these five states, this paper offers four considerations to inform regulators in the application of cost-effectiveness tests in developing CHP programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characteristics of a cost-effective blood test for colorectal cancer screening

Background: Blood-based biomarker tests can potentially change the landscape of colorectal cancer (CRC) screening. We characterize the conditions under which blood test screening would be as effective and cost-effective as annual fecal immunochemical testing or decennial colonoscopy. Methods: We used the 3 Cancer Information and Surveillance Modeling Network–Colon models to compare scenarios of no screening, annual fecal immunochemical testing, decennial colonoscopy, and a blood test meeting Centers for Medicare & Medicaid (CMS) coverage criteria (74% CRC sensitivity and 90% specificity). We varied the sensitivity to detect CRC (74%-92%), advanced adenomas (10%-50%), screening interval (1-3 years), and test cost ($25-$500). Primary outcomes included quality-adjusted life-years (QALY) gained from screening and costs for a US average-risk cohort of individuals aged 45 years. Results: Annual fecal immunochemical testing yielded 125-163 QALY gained per 1000 at a cost of 3811-5384 dollars per person, whereas colonoscopy yielded 132-177 QALY gained at a cost of 5375-7031 dollars per person. A blood test with 92% CRC sensitivity and 50% advanced adenoma sensitivity yielded 117-162 QALY gained if used every 3 years and 133-173 QALY gained if used every year but would not be cost-effective if priced above $$125 per test. If used every 3 years, a $500 blood test only meeting CMS coverage criteria yielded 83-116 QALY gained at a cost of $8559-$9413 per person. Conclusion: Blood tests that only meet CMS coverage requirements should not be recommended to patients who would otherwise undergo screening by colonoscopy or fecal immunochemical testing because of lower benefit. Blood tests need higher advanced adenoma sensitivity (above 40%) and lower costs (below $125) to be cost-effective.

60 APPLIED LIFE SCIENCES↗

Testbeds for test Readiness: Strategic Snapshot

Test bed engineering, monitoring for underground explosive and nuclear testing will be needed if the United States returns to a test posture of nuclear device testing. To maintain and rebuild the capability of test readiness, agile cost-effective test beds are needed and LANL as well as NNSS are the perfect locations to do this. Shallow and deep boreholes should be created to research containment science, diagnostic placement and optimization, coupling and emplacement science, tracer use for fracture and cratering research, and validation of test article performance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

University of New Hampshire Center for Ocean Renewable Energy (CORE) Infrastructure Enhancements

Several key components of the University of New Hampshire (UNH) Center for Ocean Renewable Energy (CORE) research, development and evaluation infrastructure for marine renewable energy (MRE) systems were enhanced under this project. These consisted of (1) A Tidal Turbine Deployment Platform (TDP) for marine hydrokinetic (MHK) turbines for use at the two UNH tidal energy test sites in Great Bay Estuary/Piscataqua River, (2) Laboratory Upgrades at Chase Ocean Engineering Laboratory (COEL), including a new towing mechanism for the UNH tow tank, a one-meter scale turbine test bed with instrumentation and a new test section for a high-speed cavitation tunnel, and the (3) Refurbishment of a Wave/Wind Offshore Test Site Environmental Buoy (for use with WEC testing). The UNH-CORE Infrastructure Enhancement Project was very successful. Existing MRE infrastructure was improved and upgraded and new MRE infrastructure was created at UNH. The infrastructure has already been extensively utilized by MHK industry and collaborators from National Laboratories and other universities, and will continue to serve the R&D mission in support of the Marine Renewable Energy and Powering the Blue Economy (PBE) industries. Testing infrastructure for marine hydrokinetic turbines was created which enables very cost-effective testing of intermediate scale turbines in a real tidal flow. A floating Turbine Deployment Platform (TDP) of dimensions 50 ft x 20 ft (15 m x 6 m), which can be used to deploy and test axial-flow or cross-flow MHK turbines with diameters up to approximately 10 ft (3 m), is now available for the marine energy industry. The platform is currently moored via pile-guides in a “floating-dock” configuration next to a bridge pier at Memorial Bridge in Portsmouth, NH, and turbines can be rotated in and out of the water via a turbine pitching mechanism. Using this new test infrastructure, the MHK industry can perform medium-to-long-term testing with inexpensive device deployment and retrieval, and re-deployment to facilitate low-cost incremental testing.

13 HYDRO ENERGY↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Coupled Aero-Hydro-Mechanical Hybrid Simulation Testing of Offshore Wind Turbines Subjected to Operational and Extreme Loading Conditions

Understanding the response of the Offshore Wind Turbine (OWT) subjected to realistic applied loads requires modeling the whole structure including its soil-foundation system. This requires unique and innovative testing facilities. OWT systems experience cyclic and dynamic loading due to wind, wave, current, rotor vibrations (i.e., 1P load) and vibrations caused by the blade shadowing effects (2P/3P loads). These loads are complicated in nature and have varying amplitudes, frequencies, and directions. Investigating the response of the entire OWT system including the soil-foundation system under these complex loading conditions, requires: (1) full understanding of the loading characteristics including: the power take-off mechanical load (1P and 3P), and areo- and hydrodynamic loads that the OWT system is subjected to; (2) testing facility with unique multidirectional loading capabilities that allows for simultaneous application of realistic wind, wave and machine loads, axial gravity loads, and induced overturning moments; and (3) unique and cost-effective testing techniques that allow for accurate analysis of the overall response of the OWT system under realistic conditions such as: Real-Time Hybrid Simulation (RTHS).

17 WIND ENERGY↗

Fire Whirl Investigation

A series of experiments were performed with the objective of achieving an extreme thermal environment by creating a fire whirl in an enclosure in facilities at the Thermal Test Complex (TTC) at Sandia National Laboratories. The motivation for the experiments is based on results from previous experiments performed at Sandia in an igloo representing a mock weapon's storage facility. In that test series, a fire whirl developed within the igloo resulting in extremely high heat flux levels. This environment was created with a pool fire of 4.6-m in diameter and was not under controlled, repeatable conditions. The objective of the current tests is to have the ability to create this environment in a repeatable controlled environment at a smaller scale, namely with a pool fire not above 3-m diameter effectively, thereby allowing for repeatable, cost-effective testing. In FY15, six tests were conducted in the Crosswind Test Facility (XTF), using a 1.77 m square pan. In FY16, three tests were conducted in the Fire Laboratory for Accreditation of Modeling by Experiment (FLAME) using a 3-m diameter pan. Both of these test series utilized the same enclosure. In FY17, a single test was performed in XTF using a 2.7 m square pan using a modified enclosure which included a ceiling. All tests used Jet-A as the fuel. The wind speed and gap width of the enclosure were varied for the FY15 XTF tests and the gap width and effect of insulation on the enclosure walls were varied for the FY16 FLAME tests. Fuel regression rates, heat flux, and gas velocity measurements were obtained. The results from the FY15 and FY16 test series indicate that fuel regression rates and peak heat flux levels are a factor of two higher than non-fire whirl pool fires of equivalent diameter. The results from the FY17 test using an enclosure with a ceiling met the objective of the test series by achieving temperatures of nearly 1400°C and heat flux levels of 400 kW/m 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Efficiency Potential in the U.S. Single-Family Housing Stock

Typical approaches for assessing energy efficiency potential in buildings use a limited number of prototypes, and therefore suffer from inadequate resolution when pass-fail cost-effectiveness tests are applied, which can significantly underestimate or overestimate the economic potential of energy efficiency technologies. This analysis applies a new approach to large-scale residential energy analysis, combining the use of large public and private data sources, statistical sampling, detailed building simulations, and high-performance computing to achieve unprecedented granularity - and therefore accuracy - in modeling the diversity of the single-family housing stock. The result is a comprehensive set of maps, tables, and figures showing the technical and economic potential of 50 plus residential energy efficiency upgrades and packages for each state. Policymakers, program designers, and manufacturers can use these results to identify upgrades with the highest potential for cost-effective savings in a particular state or region, as well as help identify customer segments for targeted marketing and deployment. The primary finding of this analysis is that there is significant technical and economic potential to save electricity and on-site fuel use in the single-family housing stock. However, the economic potential is very sensitive to the cost-effectiveness criteria used for analysis. Additionally, the savings of particular energy efficiency upgrades is situation-specific within the housing stock (depending on climate, building vintage, heating fuel type, building physical characteristics, etc.).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery↗

Utility Combined Heat and Power (CHP) Programs

This issue brief provides an overview of energy efficiency portfolios offered by electric and gas utilities that include CHP incentive programs, with examples of program drivers, structures, and eligibility criteria. The document discusses best practices for designing and administering a utility CHP incentive program, including cost-effectiveness tests and market outreach strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of PCR Systems for Field Screening of Bacillus anthracis

There is little published data on the performance of hand-portable polymerase chain reaction (PCR) instruments that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated five commercially available hand-portable PCR instruments for detection of Bacillus anthracis (Ba). We designed a cost-effective, statistically-based test plan that allows instruments to be evaluated at performance levels ranging from 0.85-0.95 lower confidence bound (LCB) on the probability of detection (POD) at confidence levels of 80-95%. We assessed specificity using purified genomic DNA from 13 Ba strains and 18 Bacillus near neighbors, interference with 22 common hoax powders encountered in the field, and PCR inhibition when Ba spores were spiked into these powders. Our results indicated that three of the five instruments achieved >0.95 LCB on the POD with 95% confidence at test concentrations of 2,000 genome equivalents/mL (comparable to 2,000 spores/mL), displaying more than sufficient sensitivity for screening suspicious powders. These instruments exhibited no false positive results or PCR inhibition with common hoax powders, and reliably detected Ba spores spiked into common hoax powders, though some issues with instrument controls were observed. Our testing approach enables efficient instrument performance testing to a statistically rigorous and cost-effective test plan to generate performance data that will allow users to make informed decisions regarding the purchase and use of biodetection equipment in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Servo-aero-gravo-elastic (SAGE) scaling and its application to a 13-MW downwind turbine

Reduced scale wind turbines can be extremely cost-effective to test new rotor concepts since prototype costs are heavily dependent on the rotor diameter. Ideally, the scaled model would have the same non-dimensional deflections, dynamics, and control behavior as the full-scale model. This would provide a high-fidelity demonstration of the full-scale performance, which is ideal if the full-scale turbine has significant aeroelastic interactions. To this end, servo-aero-gravo-elastic (SAGE) scaling is developed and applied to a 13-MW turbine that is scaled to a 20% scale model. The scaling preserves the tip-speed ratio, the rotor speed normalized by the flapping frequency, and the tip deflections normalized by the blade length. In addition, the controller employs the same control structure (gain-scheduled pitch control and variable speed torque control) and is scaled dynamically (e.g., matching non-dimensional time constant of the pitch angle, etc.). Furthermore, the thrust, gravity, and centrifugal moments are scaled such that the load angles are preserved as a function of a non-dimensional wind speed. However, the environmental scaling must consider differences in Reynolds number (since this parameter cannot be held constant) and subsequent changes in the axial induction factor. While the presented results showcase these differences during operational conditions, the non-dimensional tip deflections remain comparable through all wind speed ranges, indicating the viability of the SAGE scaling method in matching full-scale aeroelastic responses.

Kaminski, Meghan (ORCID:0000000322334784)↗

An Advanced Meso-Scale Peridynamic Modeling Technology using High-Performance Computing for Cost-Effective Product Design and Testing of Carbon Fiber Reinforced Polymer Composites in Light-weight Vehicles

We study a peridynamic composite modeling technology based on the discontinuous Galerkin finite element method, implemented in the commercial LS-DYNA software, for modeling and prediction of failure in carbon fiber reinforced polymer composites. The proposed technology is developed for the material failure analysis at the meso-scale, which provides the prevailing fiber-matrix interaction mechanism, without adoption of the representative volume element method and thus avoiding complicated numerical calibration procedures. Three types of experimental tests—in-plane coupon test, out-of-plane coupon test, and a component crash test—are simulated in a high-performance computing environment to assess the performance of the proposed peridynamic composite modeling technology.

36 MATERIALS SCIENCE↗

Cross-current leaching of indium from end-of-life LCD panels

Graphical abstract: Display Omitted - Highlights: • End-of-life LCD panels represent a source of indium. • Several experimental conditions for indium leaching have been assessed. • Indium is completely extracted with 2 M sulfuric acid at 80 °C for 10 min. • Cross-current leaching improves indium extraction and operating costs are lowered. • Benefits to the environment come from reduction of CO{sub 2} emissions and reagents use. - Abstract: Indium is a critical element mainly produced as a by-product of zinc mining, and it is largely used in the production process of liquid crystal display (LCD) panels. End-of-life LCDs represent a possible source of indium in the field of urban mining. In the present paper, we apply, for the first time, cross-current leaching to mobilize indium from end-of-life LCD panels. We carried out a series of treatments to leach indium. The best leaching conditions for indium were 2 M sulfuric acid at 80 °C for 10 min, which allowed us to completely mobilize indium. Taking into account the low content of indium in end-of-life LCDs, of about 100 ppm, a single step of leaching is not cost-effective. We tested 6 steps of cross-current leaching: in the first step indium leaching was complete, whereas in the second step it was in the range of 85–90%, and with 6 steps it was about 50–55%. Indium concentration in the leachate was about 35 mg/L after the first step of leaching, almost 2-fold at the second step and about 3-fold at the fifth step. Then, we hypothesized to scale up the process of cross-current leaching up to 10 steps, followed by cementation with zinc to recover indium. In this simulation, the process of indium recovery was advantageous from an economic and environmental point of view. Indeed, cross-current leaching allowed to concentrate indium, save reagents, and reduce the emission of CO{sub 2} (with 10 steps we assessed that the emission of about 90 kg CO{sub 2}-Eq. could be avoided) thanks to the recovery of indium. This new strategy represents a useful approach for secondary production of indium from waste LCD panels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small-Scale Experiments.10-gallon drum experiment summary

A series of sub-scale (10-gallon) drum experiments were conducted to characterize the reactivity, heat generation, and gas generation of mixtures of chemicals believed to be present in the drum (68660) known to have breached in association with the radiation release event at the Waste Isolation Pilot Plant (WIPP) on February 14, 2014, at a scale expected to be large enough to replicate the environment in that drum but small enough to be practical, safe, and cost effective. These tests were not intended to replicate all the properties of drum 68660 or the event that led to its breach, or to validate a particular hypothesis of the release event. They were intended to observe, in a controlled environment and with suitable diagnostics, the behavior of simple mixtures of chemicals in order to determine if they could support reactivity that could result in ignition or if some other ingredient or event would be necessary. There is a significant amount of uncertainty into the exact composition of the barrel; a limited sub-set of known components was identified, reviewed with Technical Assessment Team (TAT) members, and used in these tests. This set of experiments was intended to provide a framework to postulate realistic, data-supported hypotheses for processes that occur in a “68660-like” configuration, not definitively prove what actually occurred in 68660.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Refined BISON-Griffin Workflow For Designing Targeted TRISO Transient Experiments In The Transient Reactor Test Facility

U.S. industry is expected to deploy tristructural isotropic (TRISO) particle fuel technologies for commercial reactors within the next decade. In our previous work, we defined a preliminary transient design space for TRISO fuels, identified potential gaps in the available data, and began to develop multiphysics modeling tools that could be applied to design targeted Transient Reactor Test Facility (TREAT) experiments to fill these gaps. This work builds on that foundation by (1) updating BISON fuel performance and Griffin reactor physics models to reflect the current TREAT experiment tube and capsule designs,(2) coupling the codes to improve the accuracy and usability of the transient design analyses, and (3) demonstrating their use over an expanded design space that includes fuel burnup. The simulated mechanical responses of the TRISO particles were complex functions of fission product accumulation, fission gas release, and irradiation-induced dimensional change in the pyrolytic carbon layers. Predicted tangential stresses in particle silicon carbide layers were least compressive for preheated tests involving fresh fuels but remained compressive throughout the ranges of temperature, heat rate, and burnup considered in this work. Finally, comparisons between the potential TREAT transients and historical test reactor irradiations showed that the TREAT tests would produce significantly lower average energy deposition rates, yielding less severe transients with greater relevance to near-term commercial applications. Use of these predictive capabilities has the potential to increase the value of each test, improving the overall efficiency and cost effectiveness of transient testing for TRISO and other advanced fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WellSTIC: A Cost-Effective Sensor for Performing Point Dilution Tests to Measure Groundwater Velocity in Shallow Aquifers

Many individual measurement points are required to characterize groundwater velocity within an aquifer. Groundwater velocity is most commonly measured using a network of >5 cm diameter monitoring wells, which, if not already present at a site, are expensive and labor-intensive to install. Drive-point piezometers—simple, cost-effective wells that can be installed by hand—are a common tool for sampling groundwater in shallow, alluvial aquifers, but most groundwater velocity measurement techniques require equipment that is too large for these narrow (usually <2 cm inside diameter) piezometers. In this technical note, we introduce a low-cost sensor and well packer system (<$90 USD) for performing point dilution tests in narrow piezometers. Field data show that the magnitude of groundwater velocity measured with this technique agrees with velocities computed from natural gradient tracer tests. Additionally, with proper calibration, these sensors can be used to continuously monitor in-well specific conductance, either during inter-well tracer tests with saline tracers or for water quality monitoring. Finally, this system is a viable tool for rapid assessment of the magnitude of groundwater velocity in shallow aquifers.

54 ENVIRONMENTAL SCIENCES↗