Search NASA⌕ Search

SEARCH · Search NASA

Results for “cross calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Methods for Radiometric Cross-Calibration of Imaging Sensors With and Without Overlapping Collections

This slide presentation reviews methods of cross calibration for imaging sensors. Cross calibration methods fall under two categories: (1) Relies on knowledge of a source that is common to both sensors, (2) Typically near-coincident views. Some work has used methods that do not require simultaneous data collections. This talk discusses the International System of Units (SI) -traceable approaches that permit cross-calibration. It describes on-orbit cross-calibration methods that are typically used, with and without overlapping views. It reviews sample results. It also describes a method without overlapping views and without on-site measurements.

Thome, K. J.↗

Cross Calibration and Validation Using CLARREO

The presentation focuses on study questions, effort, and result. Study questions include a focus on MW/LW, error sources and what can be expected, how validation will be performed and what resolution is required, and spatial resolution required for cross-calibration. Study effort includes empirical approach by examining AIRS ,IASI and MODIS cross-calibration methods already in place and estimate the number of clear and Dome C observations possible versus spatial resolution. Study results include 5000 sampler per cross-calibration recommended, insufficient cloud free and Dome C AWS observations for cross calibration and validation at 100km, and less than 20 km IFOV at 100 km swath needed to achieve sufficient samples for cross-calibration of CLARREO.

calibration↗

In-Situ Transfer Standard and Coincident-View Intercomparisons for Sensor Cross-Calibration

There exist numerous methods for accomplishing on-orbit calibration. Methods include the reflectance-based approach relying on measurements of surface and atmospheric properties at the time of a sensor overpass as well as invariant scene approaches relying on knowledge of the temporal characteristics of the site. The current work examines typical cross-calibration methods and discusses the expected uncertainties of the methods. Data from the Advanced Land Imager (ALI), Advanced Spaceborne Thermal Emission and Reflection and Radiometer (ASTER), Enhanced Thematic Mapper Plus (ETM+), Moderate Resolution Imaging Spectroradiometer (MODIS), and Thematic Mapper (TM) are used to demonstrate the limits of relative sensor-to-sensor calibration as applied to current sensors while Landsat-5 TM and Landsat-7 ETM+ are used to evaluate the limits of in situ site characterizations for SI-traceable cross calibration. The current work examines the difficulties in trending of results from cross-calibration approaches taking into account sampling issues, site-to-site variability, and accuracy of the method. Special attention is given to the differences caused in the cross-comparison of sensors in radiance space as opposed to reflectance space. The results show that cross calibrations with absolute uncertainties lesser than 1.5 percent (1 sigma) are currently achievable even for sensors without coincident views.

Advanced Spaceborne Thermal Emission and Reflectio↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗

Cross-calibration between airborne SAR sensors

As Synthetic Aperture Radar (SAR) system performance and experience in SAR signature evaluation increase, quantitative analysis becomes more and more important. Such analyses require an absolute radiometric calibration of the complete SAR system. To keep the expenditure on calibration of future multichannel and multisensor remote sensing systems (e.g., X-SAR/SIR-C) within a tolerable level, data from different tracks and different sensors (channels) must be cross calibrated. The 1989 joint E-SAR/DC-8 SAR calibration campaign gave a first opportunity for such an experiment, including cross sensor and cross track calibration. A basic requirement for successful cross calibration is the stability of the SAR systems. The calibration parameters derived from different tracks and the polarimetric properties of the uncalibrated data are used to describe this stability. Quality criteria for a successful cross calibration are the agreement of alpha degree values and the consistency of radar cross sections of equally sized corner reflectors. Channel imbalance and cross talk provide additional quality in case of the polarimetric DC-8 SAR.

Zink, Manfred↗

Cross Calibration of SeaWiFS and MODIS Using On-Orbit Observations of the Moon

Observations of the Moon provide a primary technique for the on-orbit cross calibration of Earth remote sensing instruments. Monthly lunar observations are major components of the on-orbit calibration strategies of SeaWiFS and MODIS. SeaWiFS has collected more than 132 low phase angle and 59 high phase angle lunar observations over 12 years, Terra MODIS has collected more than 82 scheduled and 297 unscheduled lunar observations over 9 years, and Aqua MODIS has collected more than 61 scheduled and 171 unscheduled lunar observations over 7 years. The NASA Ocean Biology Processing Group s Calibration and Validation Team and the NASA MODIS Characterization Support Team use the USGS RObotic Lunar Observatory (ROLO) photometric model of the Moon to compare these time series of lunar observations over time and varying observing geometries. The cross calibration results show that Terra MODIS and Aqua MODIS agree, band-to-band, at the 1-3% level, while SeaWiFS and either MODIS instrument agree at the 3-8% level. The combined uncertainties of these comparisons are 1.3% for Terra and Aqua MODIS, 1.4% for SeaWiFS and Terra MODIS, and 1.3% for SeaWiFS and Aqua MODIS. Any residual phase dependence in the ROLO model, based on these observations, is less than 1.7% over the phase angle range of -80deg to -6deg and +5deg to +82deg . The lunar cross calibration of SeaWiFS, Terra MODIS, and Aqua MODIS is consistent with the vicarious calibration of ocean color products for these instruments, with the vicarious gains mitigating the calibration biases for the ocean color bands.

Eplee, Robert E., Jr.↗

VNIR and SWIR transfer radiometers developed at NRLM for preflight laboratory cross-calibration

One purpose of preflight laboratory cross-calibration is to avoid the incorrect setting of instrument dynamic range due to calibration mistakes at individual instrument manufacturers. A second purpose is to make corrections of instrument responsivities to have consistent radiance scales among instruments. A third reason is to clarify the state of the art in the absolute responsivity determination of VIS/NIR and SWIF instruments in the EOS era. And fourth is the purpose of improving the preflight calibration accuracy if necessary to meet the EOS requirement.

Ono, A.↗

Cross-calibration survey (VISNIR)

Included in the summary of the VISNIR survey is (1) a statement of the preferred cross-calibration approach, as endorsed by select members of the VISNIR group, (2) two viewgraphs which summarize the wavelength and fields-of-view of the various instruments, and (3) a listing of these same data, as given by the respective calibration representatives in the survey responses. The Earth Observing System (EOS) Project is fundamentally committed to the acquisition of data which can be reduced to geophysical data products of high and known accuracy. One possible method of insuring the primary data products are of known accuracy is to use the instruments themselves against the same sources to provide an independent check that a common understanding of accuracy exists. The goal then of the radiometric 'Cross-Calibration' at the integrator facility (GE) would be to convincingly establish as late as feasible in the Integration and Test (I&T) cycle that, when stimulated with common sources, the appropriate EOS instrument measurements agree within their previously established accuracy estimates across a useful radiance range, accounting for the additional uncertainty associated with the unique properties of the test set-up itself.

Bruegge, Carol J.↗

Special report, cross calibration of JHU test equipment with GSFC vacuum optical bench

Tests were conducted to confirm the validity of the absolute calibrations which have been performed with the Apollo 17 ultraviolet spectrometer (UVS) in the calibration test equipment (CTE) which were constructed for that purpose. To accomplish this the prototype UV spectrometer SN/01 was retrofitted to be substantially identical to the qualification unit and to the two flight units. It was renamed the cross calibration unit (CCU). The instrument was first calibrated in the JHU calibration test equipment (CTE), then installed in the vacuum optical bench (VOB) at Goddard Space Flight Center and calibrated. The following day a second CTE calibration was conducted which provided substantially the same calibration values as were obtained on the first CTE calibration, and showed remarkably close agreement with the VOB calibration values at two of the wavelengths which were studied. The VOB results at the third wavelength (1216 A) indicate the CTE calibration at 1216 A is 15% too low. This apparent discrepancy is discussed and presents a very important result of the cross calibration effort.

Fastie, W. G.↗

Cross-Calibration of GNC and OLA LIDAR Systems Onboard OSIRIS-REx

The Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission carried two distinct light detection and ranging (LIDAR) systems: A scanning LIDAR called OSIRIS-REx Laser Altimeter (OLA) as part of the science payload, and a flash LIDAR system has part of the Guidance, Navigation, & Control (GNC) subsystem to serve as a navigation sensor during TAG. This presents a unique opportunity to compare the performance of the two LIDAR systems in close proximity to a small asteroid body. During the Orbital B mission phase, between June to August 2019, the OSIRIS-REx spacecraft orbited Bennu in a near-circular terminator orbit during which the altitude above the surface varied between 645 m to 740 m. Over five-week period observations were recorded with the OLA instrument that were subsequently used to construct a global digital terrain map (DTM) with a resolution of 5 cm and accuracy of ±20 cm. This model provides an excellent reference for assessing the performance of the GNC LIDAR system. Two different GNC LIDAR checkout activities were also conducted during the Orbital B phase: A limb-crossing check-out featured a series of slews to collect GNC LIDAR data across varying ranges and phase angles and operate the automatic gain control modes of the device; An OLA-GNC LIDAR cross calibration was designed to collect data from both the OLA and GNC LIDAR devices with overlapping footprints while the spacecraft was pointed nadir. This paper compares the on-orbit performance observed during the cross-calibration activity. The OLA-based global DTM and point clouds are used to evaluate the GNC LIDAR not available during previous analysis. The GNC LIDAR measurements were found to be well within accuracy and precision specified for the instrument, but much noisier than the measurements from OLA within this operating regime.

Jason M Leonard↗

Multitemporal Cross-Calibration of the Terra MODIS and Landsat 7 ETM+ Reflective Solar Bands

In recent years, there has been a significant increase in the use of remotely sensed data to address global issues. With the open data policy, the data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Enhanced Thematic Mapper Plus (ETM+) sensors have become a critical component of numerous applications. These two sensors have been operational for more than a decade, providing a rich archive of multispectral imagery for analysis of mutitemporal remote sensing data. This paper focuses on evaluating the radiometric calibration agreement between MODIS and ETM+ using the near-simultaneous and cloud-free image pairs over an African pseudo-invariant calibration site, Libya 4. To account for the combined uncertainties in the top-of-atmosphere (TOA) reflectance due to surface and atmospheric bidirectional reflectance distribution function (BRDF), a semiempirical BRDF model was adopted to normalize the TOA reflectance to the same illumination and viewing geometry. In addition, the spectra from the Earth Observing-1 (EO-1) Hyperion were used to compute spectral corrections between the corresponding MODIS and ETM+ spectral bands. As EO-1 Hyperion scenes were not available for all MODIS and ETM+ data pairs, MODerate resolution atmospheric TRANsmission (MODTRAN) 5.0 simulations were also used to adjust for differences due to the presence or lack of absorption features in some of the bands. A MODIS split-window algorithm provides the atmospheric water vapor column abundance during the overpasses for the MODTRAN simulations. Additionally, the column atmospheric water vapor content during the overpass was retrieved using the MODIS precipitable water vapor product. After performing these adjustments, the radiometric cross-calibration of the two sensors was consistent to within 7%. Some drifts in the response of the bands are evident, with MODIS band 3 being the largest of about 6% over 10 years, a change that will be corrected in Collection 6 MODIS processing.

MODIS↗

Radiometric Calibration of the AWiFS Sensor and a Cross-calibration Enhanced Vicarious Calibration Technique

Using vicarious calibration validation of moderate resolution sensors such as AWiFS is complicated by requiring more land area to ensure proper registration and sufficient pixel numbers. A trial AWiFS calibration was performed on a grass site that consisted of two dramatically different grass heights. Ground truth data was collected over relatively small areas representing only a few pixels. The radiometric gain results for each of these areas will be reported. To enhance this analysis, since a near coincidence high resolution image was collected, the high resolution data was effectively resized to produce pixels comparable to AWiFS and the atmospheric model was used to produce a top of canopy radiance map. Multiple uniform vegetated areas of several radiances were then identified and subsequently propagated to the top of atmosphere viewpoint of the moderate resolution (AWiFS) satellite. The radiometric gain was then calculated based on the vendor high resolution satellite gains (for the 3 bands with comparable wavelengths). Band-to-band conversion was performed assuming a hyperspectral reflectance based on the standard vegetated site. The initial comparison produces AWiFS radiometric gain values that agree to better than 10% of the values measured using the standard vicarious gain technique.

Aaron, David↗

Ar-40/Ar-39 ages and trace element contents of Apollo 14 breccias - An interlaboratory cross-calibration of Ar-40/Ar-39 standards

Rare gas data are presented from step-wise heatings of lunar breccias 14066 and 14318 and from an interlaboratory cross-calibration of five standards used in Ar-40/Ar-39 dating. While different in detail, the Ar release patterns in the four samples yield indistinguishable plateau ages of 3.93 plus or minus 0.03 b.y. and above 400 C total ages of 3.87 plus or minus 0.06 b.y. Concentrations of K, Ca, Ba, Br, U and I are given for 14318 and 14066. We also present an updating of all of the Ar-40/Ar-39 ages and trace element concentrations previously published by this laboratory.

Alexander, E. C., Jr.↗

Cross-Calibration of AQUA-MODIS and NPP-VIIRS Reflective Solar Bands for a Seamless Record of CERES Cloud and Flux Properties

The CERES measured shortwave and longwave fluxes rely on the cloud properties derived using the coincident observations from the accompanying high-resolution MODIS and VIIRS imagers. The calibration consistency is required between MODIS and VIIRS radiances to ensure that the CERES provided cloud property retrievals are temporally consistent. This paper presents multiple approaches of cross-calibrating the spectrally comparable reflective solar bands (RSB) of Aqua-MODIS and NPP- VIIRS, and estimates the radiometric biases for individual band pair. The inter-comparison is performed between the Aqua-MODIS collection 6.1 level 1B and NPP-VIIRS Land PEATE V1 datasets. Radiometric biases up to 3% were estimated bet een the MODIS and VIIRS radiances for visible bands.

Bhatt, Rajendra↗

On-Orbit Cross-Calibration of AM Satellite Remote Sensing Instruments using the Moon

On April 14,2003, three Earth remote sensing spacecraft were maneuvered enabling six satellite instruments operating in the visible through shortwave infrared wavelength region to view the Moon for purposes of on-orbit cross-calibration. These instruments included the Moderate Resolution Imaging Spectroradiometer (MODIS), the Multi-angle Imaging SpectroRadiometer (MISR), the Advanced Spaceborne Thermal Emission and Reflection (ASTER) radiometer on the Earth Observing System (EOS) Terra spacecraft, the Advanced Land Imager (ALI) and Hyperion instrument on Earth Observing-1 (EO-1) spacecraft, and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) on the SeaStar spacecraft. Observations of the Moon were compared using a spectral photometric mode for lunar irradiance developed by the Robotic Lunar Observatory (ROLO) project located at the United States Geological Survey in Flagstaff, Arizona. The ROLO model effectively accounts for variations in lunar irradiance corresponding to lunar phase and libration angles, allowing intercomparison of observations made by instruments on different spacecraft under different time and location conditions. The spacecraft maneuvers necessary to view the Moon are briefly described and results of using the lunar irradiance model in comparing the radiometric calibration scales of the six satellite instruments are presented here.

Butler, James J.↗

SO2 on Venus: A final cross-calibration with Pioneer Venus

In the present reporting period we have met with the Pioneer Venus PI to collaborate on the recalibration of the UV spectrometer of Pioneer Venus. The associated data reduction and analysis activities have been completed. The sensitivity of the UV spectrometer has been steadily declining since orbit insertion of Pioneer Venus in 1978 due to aging of the detector tubes. The sensitivity decline is a strong function of wavelength and the rate of decline is also a function of time. Measures were taken to reduce the light dose received by the instrument to slow down the sensitivity decline. The stellar calibration using the bright UV star Hadar in 1990 indicates that the sensitivity decline may have slowed down more than have been previously estimated. The derived amount of SO2 from Pioneer Venus depends on the accuracy of the absolute sensitivity of the UV spectrometer. The previous cross calibration between IUE and Pioneer Venus led to the use of the same solar flux data for reducing and modelling data from both IUE and Pioneer Venus. The comparison between the 1991 IUE results and the Pioneer Venus stellar calibration carried out in 1990 will allow a more accurate determination of sensitivity decline of the PV UV spectrometer. The result of this comparison will be crucial in determining the trend of SO2 in the Venus atmosphere.

Stern, S. Alan↗