Search NASASearch

SEARCH · Search NASA

Results for “cryocooler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS

Multicaloric Cryocooling Using Heavy Rare-Earth Free La(Fe,Si) 13 -Based Compounds

The transition toward a carbon-neutral society based on renewable energies goes hand in hand with the availability of energy-efficient technologies. Here, magnetocaloric cooling is a very promising refrigeration technology to fulfill this role regarding cryogenic gas liquefaction. However, the current reliance on highly resource critical, heavy rare-earth-based compounds as magnetocaloric material makes global usage unsustainable. Here, we aim to mitigate this limitation through the utilization of a multicaloric cooling concept, which uses the external stimuli of isotropic pressure and magnetic field to tailor and induce magnetostructural phase transitions associated with large caloric effects. In this study, La 0.7 Ce 0.3 Fe 11.6 Si 1.4 is used as a nontoxic, low-cost, low-criticality multiferroic material to explore the potential, challenges, and peculiarities of multicaloric cryocooling, achieving maximum isothermal entropy changes up to −28 J (kg K) −1 in the temperature range from 190 K down to 30 K. Thus, the multicaloric cooling approach offers an additional degree of freedom to tailor the phase transition properties and may lead to energy-efficient and environmentally friendly gas liquefaction based on designed-for-purpose, noncritical multiferroic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Zhou, Yang [Argonne]

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Compact cryomodule for mobile stand-alone superconducting industrial accelerators

Superconducting RF (SRF) accelerators have the potential to be more profitable in comparison with normally conducting accelerators, as long they can be made compact, achieve operational simplicity, autonomy, trans- portability, satisfactory energy efficiency, as well as have reasonable costs. The development of SRF technologies such as Nb 3 Sn coating, conductively-cooled resonators, and high-capacity liquid-helium-free cryocoolers made SRF accelerators mobile and energetically and economically efficient at a beam power of tens of kW. One of the key elements of such an accelerator is the cryomodule, which must have minimal thermal losses to enable operation from low power cryoheads and enable conductive cooling of SRF resonator. In this research we present the design and test results of a compact cryomodule for an industrial stand-alone SRF linear accelerator proto- type, based on 650 MHz elliptical resonators, being developed at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s

Cryogenically enhanced quasi-optical resonator for megawatt pulsed millimeter-wave sources

We report the design, cryogenic optimization, and performance modeling of a compact quasi-optical ring resonator intended to compress microwaves pulses at 170 and 250 GHz to the megawatt level. By combining ultra-low-loss CVD diamond and gold-doped silicon wafers with high-RRR copper mirrors, the calculated unloaded quality factor exceeds 4.3 × 10 5 at 20 K and yields simulated gains up to $\mathscr{G}$ = 4.1 × 10 3 . Coupling the resonator with a laser-driven semiconductor switch described by an extended Vogel model shows that 1 MW, nanosecond pulses can be generated from only 445 W of microwave drive power while dissipating 272 W into the cryostat. A practical cooling architecture using two Gifford–McMahon stages (20 and 80 K) is proposed, demonstrating that high-repetition-rate (10–20 kHz) operation is feasible with commercially available cryocoolers. The results outline a clear path toward cost-effective, table-top sources for extreme-ultraviolet lithography, dynamic nuclear polarization, and fusion systems.

Panisset, Constant [Ecole Polytechnique Federale L

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (