Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic blackbody”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cryogenic blackbody radiation calibration source

A cryogenic blackbody radiation source for providing target temperatures between room temperature and -100 C was designed, fabricated, and tested. This blackbody radiation source is intended for calibration of radiometric infrared imaging systems down to -100 C. The construction and operating principles of this apparatus are described. The long term and short term stability of the radiant source have been investigated. The emittance of the source and the source radiant uniformity have been addressed.

Burkett, Cecil G., Jr.↗

A cryogenic blackbody for millimeter wavelengths

The present cryogenic blackbody reference, or 'cold load', for mm-wavelength radiation has an emissivity of more than 0.99 over a two-octave wavelength range and can be used as a calibrating standard for sensitive IR photometers. The transmittance spectrum obtained indicates that wave impedance and index do not vary significantly over the 80-360 GHz range.

Peterson, J. B.↗

Cryogenic Blackbody-Radiation Calibration Source

Operating temperatures range from ambient down to minus 100 degrees C. V-grooved front face of source body blackened and recessed in black sleeve. Semiairtight chamber that houses source purged with dry nitrogen gas to prevent formation of dew or frost at low operating temperature.

Burkett, Cecil G., Jr.↗

CMB-S4 Instrument Modeling and Development for CMB-S4

During this thirteen month award, we focused on two main tasks relevant to the development of the CMB-S4 project: (1) The refinement of sensitivity models and use of those to optimize the instrument design, and (2) the final development and testing a cryogenic blackbody calibrator prototype, of which we then produced three copies for CMB-S4's detector testing systems at FNAL, SLAC and UIUC.

47 OTHER INSTRUMENTATION↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of AlMn TES Impedance, Noise, and Optical Efficiency in the First 150 mm Multichroic Array for Advanced ACTPol

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope features large arrays of multichroic pixels consisting of two orthogonal-polarization pairs of superconducting bolometers at two observing frequency bands. We present measurements of the detector properties and noise data in a subset of a fielded multichroic array of AlMn transition-edge sensor (TES) detectors. In this array, the distribution of critical temperature T(sub c) across detectors appears uniform at the percent level. The measured noise-equivalent power (NEP) distributions over approximately 1200 detectors are consistent with expectations. We find median NEPs of 4.0×10(exp −17) W/ √ Hz for low-band detectors and 6.2×10(exp −17) W/ √ Hz for high-band detectors under covered-window telescope test conditions with optical loading comparable to observing with precipitable water vapor approximately 0.5 mm. Lastly, we show the estimated detector optical efficiency, and demonstrate the ability to perform optical characterization over hundreds of detectors at once using a cryogenic blackbody source.

Crowley, Kevin T.↗

Parallel-Plate Capacitor TiN KIDs for Infrared Astronomy

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will characterize dust in the vicinity of high-mass stars. It requires detectors with NEPs from 2x10 -16 W Hz -1/2 to 6x10 -17 W Hz -1/2 from 25-250 microns, respectively. The mission’s sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor deposited on a Silicon (Si) substrate. The parallel plate capacitor geometry allows for reduction of the pixel spacing. We present the optical performance of a prototype BEGINS KID array at 25 microns when coupled to Fresnel zone plate lenses. We present sensitivity, optical efficiency and quasiparticle lifetime measurements taken in a cryogenic test bed with a cryogenic blackbody.

Joanna Perido↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗

A space simulation test chamber development for the investigation of radiometric properties of materials

The design, fabrication, and preliminary utilization of a thermal vacuum space simulation facility are discussed. The facility was required to perform studies on the thermal radiation properties of materials. A test chamber was designed to provide high pumping speed, low pressure, a low photon level radiation background (via high emissivity, coated, finned cryopanels), internal heat sources for rapid warmup, and rotary and linear motion of the irradiated materials specimen. The radiation detection system consists of two wideband infrared photoconductive detectors, their cryogenic coolers, a cryogenic-cooled blackbody source, and a cryogenic-cooled optical radiation modulator.

Enlow, D. L.↗

Submillimeter and millimeter wave characterization of absorbing materials

Several microwave absorbers have been characterized in terms of transmittance and reflectance at frequencies between 35 GHz and 3 THz. The materials studied were a series of iron-loaded cast epoxy absorbers known as Eccosorb. Measurements show that reflectance and absorption coefficient increase with the iron density. A dramatic decrease, by as much as a factor of 2, in absorption coefficient was observed when the samples were cooled from ambient to cryogenic temperatures. A blackbody calibrator to be operated at liquid helium temperature was constructed using the measured optical constants for these absorbers. The measured absorption coefficient for cold Eccosorb CR-110 is within 20 percent of that reported recently by Peterson and Richards.

Hemmati, H.↗

First Flight of ARCADE CMB Instrument

ARCADE (Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission) is a balloon-borne cryogenic instrument to measure the spectrum of the cosmic microwave background radiation at centimeter wavelengths. ARCADE compares the sky to an on-board external blackbody target to measure small differences between the sky spectrum and a known blackbody. The instrument uses a novel open-aperture cryogenic design to minimizes sources of systematic error. In particular, there are no windows between the cold (2.7 K) optics and the atmosphere during observations. We discuss the cryogenic performance of ARCADE during its first flight in November 2001.

Kogut, A.↗

Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations

A fabrication process is reported for prototype emitters of THz radiation, which operate cryogenically, and should provide a fast, stable blackbody source suitable for characterization of THz devices. The fabrication has been demonstrated and, at the time of this reporting, testing was underway. The emitter is similar to a monolithic silicon bolometer in design, using both a low-noise thermometer and a heater element on a thermally isolated stage. An impedance-matched, high-emissivity coat ing is also integrated to tune the blackbody properties. This emitter is designed to emit a precise amount of power as a blackbody spectrum centered on terahertz frequencies. The emission is a function of the blackbody temperature. An integrated resistive heater and thermometer system can control the temperature of the blackbody with greater precision than previous incarnations of calibration sources that relied on blackbody emission. The emitter is fabricated using a silicon- on-insulator substrate wafer. The buried oxide is chosen to be less than 1 micron thick, and the silicon device thickness is 1-2 microns. Layers of phosphorus compensated with boron are implanted into and diffused throughout the full thickness of the silicon device layer to create the thermometer and heater components. Degenerately doped wiring is implanted to connect the devices to wire-bondable contact pads at the edge of the emitter chip. Then the device is micromachined to remove the thick-handle silicon behind the thermometer and heater components, and to thermally isolate it on a silicon membrane. An impedance- matched emissive coating (ion assisted evaporated Bi) is applied to the back of the membrane to enable high-efficiency emission of the blackbody spectrum.

Chervenak, James↗

Development of a Space Irradiance Simulator for Advanced Studies and Materials Research

A lab-scale experimental apparatus that mimics the solar-thermal environment of space has recently been developed and tested at NASA Kennedy Space Center in support of novel materials research for future space science and exploration applications. The Space Irradiance Simulator (SIRS) apparatus exposes specimens up to roughly 61 mm in diameter to a similar thermal environment that exists at distances as close as 0.4 AU from the Sun. This includes a high vacuum environment, access to a deep cryogenic background temperature with optical properties that closely imitate a blackbody, and irradiance from a broadband solar “point” source at fluxes as high as 9300 W/m2. Cooling is provided by a Gifford-McMahon cryocooler capable of 25 W of cooling power at 20 K, with a base temperature of 14 K. A commercially available Xeon lamp acts as the solar source, creating broadband electromagnetic radiation with a spectrum similar to that of the Sun. Light is beamed through the vacuum chamber and onto a sample suspended within the cold-mass via a flexible quartz fiber bundle in conjunction with a custom vacuum feedthrough. The system design, fabrication, and operation are discussed; and results from the initial checkout testing of the system are presented.

A. M. Swanger↗

Scene simulation for passive IR systems

The development of large mosaic detector arrays will allow for the construction of staring long wave infrared (LWIR) sensors which can observe large fields of view instantaneously and continuously. In order to evaluate and exercise these new systems, it will be necessary to provide simulated scenes of many moving targets against an infrared clutter background. Researchers are currently developing a projector/screen system. This system is comprised of a mechanical scanner, a diffuse screen, and a miniature blackbody. A prototype of the mechanical scanner, which is comprised of four independently driven scanners, has been designed, fabricated, and evaluated under room and cryogenic vacuum conditions. A large diffuse screen has been constructed and tested for structural integrity under cryogenic/vacuum thermal cycling. Construction techniques have been developed for the fabrication of miniature high-temperature blackbody sources. Finally, a concept has been developed to use this miniature blackbody to produce a spectrally tailorable source.

Holt, J. D.↗

NASA Tech Briefs, July 2009

Topics covered include: Dual Cryogenic Capacitive Density Sensor; Hail Monitor Sensor; Miniature Six-Axis Load Sensor for Robotic Fingertip; Improved Blackbody Temperature Sensors for a Vacuum Furnace; Wrap-Around Out-the-Window Sensor Fusion System; Wide-Range Temperature Sensors with High-Level Pulse Train Output; Terminal Descent Sensor Simulation; A Robust Mechanical Sensing System for Unmanned Sea Surface Vehicles; Additive for Low-Temperature Operation of Li-(CF)n Cells; Li/CFx Cells Optimized for Low-Temperature Operation; Number Codes Readable by Magnetic-Field-Response Recorders; Determining Locations by Use of Networks of Passive Beacons; Superconducting Hot-Electron Submillimeter-Wave Detector; Large-Aperture Membrane Active Phased-Array Antennas; Optical Injection Locking of a VCSEL in an OEO; Measuring Multiple Resistances Using Single-Point Excitation; Improved-Bandwidth Transimpedance Amplifier; Inter-Symbol Guard Time for Synchronizing Optical PPM; Novel Materials Containing Single-Wall Carbon Nanotubes Wrapped in Polymer Molecules; Light-Curing Adhesive Repair Tapes; Thin-Film Solid Oxide Fuel Cells; Zinc Alloys for the Fabrication of Semiconductor Devices; Small, Lightweight, Collapsible Glove Box; Radial Halbach Magnetic Bearings; Aerial Deployment and Inflation System for Mars Helium Balloons; Steel Primer Chamber Assemblies for Dual Initiated Pyrovalves; Voice Coil Percussive Mechanism Concept for Hammer Drill; Inherently Ducted Propfans and Bi-Props; Silicon Nanowire Growth at Chosen Positions and Orientations; Detecting Airborne Mercury by Use of Gold Nanowires; Detecting Airborne Mercury by Use of Palladium Chloride; Micro Electron MicroProbe and Sample Analyzer; Nanowire Electron Scattering Spectroscopy; Electron-Spin Filters Would Offer Spin Polarization Greater than 1; Subcritical-Water Extraction of Organics from Solid Matrices; A Model for Predicting Thermoelectric Properties of Bi2Te3; Integrated Miniature Arrays of Optical Biomolecule Detectors; A Software Rejuvenation Framework for Distributed Computing; Kurtosis Approach to Solution of a Nonlinear ICA Problem; Robust Software Architecture for Robots; R4SA for Controlling Robots; Bio-Inspired Neural Model for Learning Dynamic Models; Evolutionary Computing Methods for Spectral Retrieval; Monitoring Disasters by Use of Instrumented Robotic Aircraft; Complexity for Survival of Living Systems; Using Drained Spacecraft Propellant Tanks for Habitation; Connecting Node; and Electrolytes for Low-Temperature Operation of Li-CFx Cells.

Source record↗

Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, an experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the $z$ dimension.

Rao, Shardul↗