Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

Argonaut - A Robotic System for Cryogenic Environments

Fermilab and the HEP community invest significant resources into liquid argon detectors. The largest and most expensive of these detectors will be located in the Deep Underground Neutrino Experiment (DUNE). However, recent experiences have shown that there are limited avenues of monitoring, intervention, and interaction in the internal liquid environment. This proposal shows a technological path that could provide a valuable tool to ensure or at least improve the management of these HEP detectors. The development of a robotic system named Argonaut will demonstrate several technologies including 1) demonstration of suitable mobility of a small robotic device at liquid argon temperatures, 2) demonstration of wireless communication, 3) demonstration of improved diagnostics capabilities - such as tunable optics with motion control, 4) demonstration of interconnectivity of a robotic system with hardware residing within the detector. This initial research will be a seed for extended development in cold robotics and associated technologies. This work will allow FNAL to contribute a significant technology capability to recent efforts to cryogenic detector operations.

43 PARTICLE ACCELERATORS↗

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Predictable circuit response is a critical prerequisite for accurate electronic measurements. Here, we describe a powerful yet straightforward experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic-impedance background-correction procedure to measure the temperature-dependent impedance (magnitude and phase) of up to ten individual passive circuit elements in a single cryostat run. We show how the model unambiguously identified a ∼20× drop in capacitance for 22 μF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with a parasitic capacitance of ∼300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to measure 10 and 22 pF thin-film capacitors and 100 MΩ thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, we showed that the simple data-acquisition method, coupled with our analysis model, enabled the measurement of component parasitics, and effectively extended the accuracy of a commercial LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies. We also showed that, in the current configuration, our simple approach is limited to a capacitance accuracy of ∼10 pF.

Carpenter, R. J. [Santa Clara Univ., Santa Clara, ↗

Infrared (IR) photon-sensitive spectromicroscopy in a cryogenic environment

A system designed to suppress thermal radiation background and to allow IR single-photon sensitive spectromicroscopy of small samples by using both absorption, reflection, and emission/luminescence measurements. The system in one embodiment includes: a light source; a plurality of cold mirrors configured to direct light along a beam path; a cold or warm sample holder in the beam path; windows of sample holder (or whole sample holder) are transparent in a spectral region of interest, so they do not emit thermal radiation in the same spectral region of interest; a cold monochromator or other cold spectral device configured to direct a selected fraction of light onto a cold detector; a system of cold apertures and shields positioned along the beam path to prevent unwanted thermal radiation from arriving at the cold monochromator and/or the detector; a plurality of optical, IR and microwave filters positioned along the beam path and configured to adjust a spectral composition of light incident upon the sample under investigation and/or on the detector; a refrigerator configured to maintain the detector at a temperature below 1.0K; and an enclosure configured to: thermally insulate the light source, the plurality of mirrors, the sample holder, the cold monochromator and the refrigerator.

47 OTHER INSTRUMENTATION↗

MCP-based photodetectors for cryogenic applications

The Argonne MCP-based photo detector is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein 6 cm × 6 cm sized detectors are made at Argonne National Laboratory. We have successfully built and tested our first detectors for pico-second timing and few mm spatial resolution. We discuss our efforts to customize these detectors to operate in a cryogenic environment. Initial plans aim to operate in liquid argon. As a result, we are also exploring ways to mitigate wave length shifting requirements and also developing bare-MCP photodetectors to operate in a gaseous cryogenic environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Genomic reconstruction of fossil and living microorganisms in ancient Siberian permafrost

Abstract Background Total DNA (intracellular, iDNA and extracellular, eDNA) from ancient permafrost records the mixed genetic repository of the past and present microbial populations through geological time. Given the exceptional preservation of eDNA under perennial frozen conditions, typical metagenomic sequencing of total DNA precludes the discrimination between fossil and living microorganisms in ancient cryogenic environments. DNA repair protocols were combined with high throughput sequencing (HTS) of separate iDNA and eDNA fraction to reconstruct metagenome-assembled genomes (MAGs) from ancient microbial DNA entrapped in Siberian coastal permafrost. Results Despite the severe DNA damage in ancient permafrost, the coupling of DNA repair and HTS resulted in a total of 52 MAGs from sediments across a chronosequence (26–120 kyr). These MAGs were compared with those derived from the same samples but without utilizing DNA repair protocols. The MAGs from the youngest stratum showed minimal DNA damage and thus likely originated from viable, active microbial species. Many MAGs from the older and deeper sediment appear related to past aerobic microbial populations that had died upon freezing. MAGs from anaerobic lineages, including Asgard archaea, however exhibited minimal DNA damage and likely represent extant living microorganisms that have become adapted to the cryogenic and anoxic environments. The integration of aspartic acid racemization modeling and metaproteomics further constrained the metabolic status of the living microbial populations. Collectively, combining DNA repair protocols with HTS unveiled the adaptive strategies of microbes to long-term survivability in ancient permafrost. Conclusions Our results indicated that coupling of DNA repair protocols with simultaneous sequencing of iDNA and eDNA fractions enabled the assembly of MAGs from past and living microorganisms in ancient permafrost. The genomic reconstruction from the past and extant microbial populations expanded our understanding about the microbial successions and biogeochemical alterations from the past paleoenvironment to the present-day frozen state. Furthermore, we provided genomic insights into long-term survival mechanisms of microorganisms under cryogenic conditions through geological time. The combined strategies in this study can be extrapolated to examine other ancient non-permafrost environments and constrain the search for past and extant extraterrestrial life in permafrost and ice deposits on Mars.

54 ENVIRONMENTAL SCIENCES↗

Quantum critical electro-optic and piezo-electric nonlinearities

Although electro-optic (EO) nonlinearities are essential for many quantum and classical photonics applications, a major challenge is inefficient modulation in cryogenic environments. Guided by the connection between phase transitions and nonlinearity, we identify the quantum paraelectric perovskite SrTiO 3 as a strong cryogenic EO [>500 picometers per volt (pm/V)] and piezo-electric material (>90 picocoulombs per newton) at T = 5 K, at frequencies to at least 1 megahertz. Furthermore, by tuning SrTiO 3 toward quantum criticality, we more than double the EO and piezo-electric effects, demonstrating a linear Pockels coefficient above 1000 pm/V. Furthermore, our results probe the link between quantum phase transitions, dielectric susceptibility, and nonlinearity, unlocking opportunities in cryogenic optical and mechanical systems and providing a framework for discovering new nonlinear materials.

Anderson, Christopher P. [Stanford University, CA ↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Studies of event burst phenomenon with SiPMs in liquid nitrogen

Silicon photomultiplier (SiPM) are used to collect scintillation photons in many cryogenic noble liquid detectors deployed around the world, such as DarkSide, nEXO, MEGII, ProtoDUNE and DUNE. An event burst phenomenon was observed during routine characterization on many models of SiPMs operated in liquid nitrogen. These bursts of consecutive pulses are initiated by an intense dark photoelectron pulse with an event rate much lower than the time-uncorrelated thermal dark pulse. Although the rate of these burst events is very low, it can potentially compromise some dedicated rare physics event searches which are also anticipated to be of extremely low rate. Here, we systematically studied the behavior of the event burst phenomenon and identified the probable cause of the phenomenon. Here, this investigation is important for the selection of SiPMs for use in noble liquid detectors, high energy physics experiments, and industrial applications where SiPMs are used in cryogenic environment.

47 OTHER INSTRUMENTATION↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Terahertz‐Nanoscale Visualization of the Microscopic Spin‐Charge Architecture of Colossal Magnetoresistive Switching

Resolving sub-10 nm spin switching and the associated terahertz (THz) electrodynamics during the colossal magnetoresistance (CMR) transition is a definitive frontier in reaching the fundamental spatial, temporal, and energy-dissipation limits of spin-electronics. Yet, simultaneous control of high magnetic field, cryogenic environment, and nanometer resolution has remained an elusive benchmark for THz nanoscopy, leaving the local THz dynamics of these transitions largely unexplored. Here, we overcome these limitations by utilizing a custom-built cryogenic magneto-THz scattering-type scanning near-field optical microscopy (cm-THz-sSNOM) to resolve the near-field THz spectroscopic evolution of the magnetic field-driven CMR transition in a manganite single crystal. Our measurements provide a nanoscale visualization of the THz conductivity, capturing the moment that magnetic-field-induced spin switching triggers the transition from an antiferromagnetic insulator to a ferromagnetic metal. An ellipsoidal near-field model reveals a multi-scale transition initiated by 1–2 nm isolated spin-flip sites at low magnetic fields, which coalesce into ∼15 nm conducting regions as the threshold field is approached. These results provide an nano-THz view of CMR switching, establishing an analysis framework for mapping spin–charge–lattice–orbit–coupled dynamics at spatial scales that transcend the nominal sSNOM resolution.

Haeuser, Samuel [Iowa State University, Ames, IA (↗

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Cryogenic mechanical behaviors of CrMnFeCoNi high-entropy alloy

The CrMnFeCoNi high-entropy alloy (HEA) exhibits higher yield strength, ultimate strength and ductility at lower temperature. To further clarify the effect of the testing temperature on microstructure evolution, in this study in-situ synchrotron-based high-energy X-ray diffraction tensile tests were carried out from 298 K down to 123 K. The enhanced yield strength of the alloy at cryogenic temperatures can be attributed to the greater lattice distortion prior to plastic deformation. Higher strain hardening rate leads to the simultaneously enhanced strength and ductility of the studied HEA below room temperature. Both dynamic Hall-Petch hardening (twinning) and dislocation hardening provide high work hardening capacity for this alloy during the plastic deformation at cryogenic temperatures. The increased dislocation density and nano-twins at cryogenic temperatures can be attributed to the decrease in the stacking fault energy as the deformation temperature decreases. These studies could provide an in-depth understanding for the strengthening mechanisms of the HEA in different temperature conditions and guide the exploration of HEAs with superb mechanical properties at cryogenic environments.

36 MATERIALS SCIENCE↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗