Search NASASearch

SEARCH · Search NASA

Results for “cryogenic environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)

Correcting impedance measurements for background parasitics to characterize circuit components in cryogenic environments

Predictable circuit response is a critical prerequisite for accurate electronic measurements. Here, we describe a powerful yet straightforward experimental method and analysis model that utilizes an affordable LCR meter in conjunction with an in situ parasitic-impedance background-correction procedure to measure the temperature-dependent impedance (magnitude and phase) of up to ten individual passive circuit elements in a single cryostat run. We show how the model unambiguously identified a ∼20× drop in capacitance for 22 μF 5XR multilayer ceramic capacitors cooled from 300 K to 360 mK in an environment with a parasitic capacitance of ∼300 pF. The same experimental procedure, based on a simple two-wire measurement, was also used to measure 10 and 22 pF thin-film capacitors and 100 MΩ thick-film resistors. The results showed that the resistor values increased by up to an order of magnitude when the devices were cooled from 300 K to 360 mK. Most importantly, we showed that the simple data-acquisition method, coupled with our analysis model, enabled the measurement of component parasitics, and effectively extended the accuracy of a commercial LCR meter beyond its manufacturer-guaranteed values for a wide range of measurement frequencies. We also showed that, in the current configuration, our simple approach is limited to a capacitance accuracy of ∼10 pF.

Carpenter, R. J. [Santa Clara Univ., Santa Clara,

Quantum critical electro-optic and piezo-electric nonlinearities

Although electro-optic (EO) nonlinearities are essential for many quantum and classical photonics applications, a major challenge is inefficient modulation in cryogenic environments. Guided by the connection between phase transitions and nonlinearity, we identify the quantum paraelectric perovskite SrTiO 3 as a strong cryogenic EO [>500 picometers per volt (pm/V)] and piezo-electric material (>90 picocoulombs per newton) at T = 5 K, at frequencies to at least 1 megahertz. Furthermore, by tuning SrTiO 3 toward quantum criticality, we more than double the EO and piezo-electric effects, demonstrating a linear Pockels coefficient above 1000 pm/V. Furthermore, our results probe the link between quantum phase transitions, dielectric susceptibility, and nonlinearity, unlocking opportunities in cryogenic optical and mechanical systems and providing a framework for discovering new nonlinear materials.

Anderson, Christopher P. [Stanford University, CA

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]

Terahertz‐Nanoscale Visualization of the Microscopic Spin‐Charge Architecture of Colossal Magnetoresistive Switching

Resolving sub-10 nm spin switching and the associated terahertz (THz) electrodynamics during the colossal magnetoresistance (CMR) transition is a definitive frontier in reaching the fundamental spatial, temporal, and energy-dissipation limits of spin-electronics. Yet, simultaneous control of high magnetic field, cryogenic environment, and nanometer resolution has remained an elusive benchmark for THz nanoscopy, leaving the local THz dynamics of these transitions largely unexplored. Here, we overcome these limitations by utilizing a custom-built cryogenic magneto-THz scattering-type scanning near-field optical microscopy (cm-THz-sSNOM) to resolve the near-field THz spectroscopic evolution of the magnetic field-driven CMR transition in a manganite single crystal. Our measurements provide a nanoscale visualization of the THz conductivity, capturing the moment that magnetic-field-induced spin switching triggers the transition from an antiferromagnetic insulator to a ferromagnetic metal. An ellipsoidal near-field model reveals a multi-scale transition initiated by 1–2 nm isolated spin-flip sites at low magnetic fields, which coalesce into ∼15 nm conducting regions as the threshold field is approached. These results provide an nano-THz view of CMR switching, establishing an analysis framework for mapping spin–charge–lattice–orbit–coupled dynamics at spatial scales that transcend the nominal sSNOM resolution.

Haeuser, Samuel [Iowa State University, Ames, IA (

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]

Lifetime study of the ColdADC for the Deep Underground Neutrino Experiment

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of four liquid argon time projection chambers. Each contains 17 kilotons liquid argon as the target material in order to measure neutrino oscillations. Approximately 40,000 ColdADC ASICs will be installed for DUNE in the first two large detectors and will be operated at cryogenic temperatures during the experiment without replacement. The lifetime of the ColdADC is a critical parameter affecting the data quality and physics sensitivity of the experiment. A measurement of the lifetime of the ColdADC was carried out, and the results shown in this paper assure orders of magnitude longer lifetime of the ColdADC than the planned operation time of the detectors.

Front-end electronics for detector readout

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Magnetic field driven emergent phenomena: Insights from magneto-optics and nanoscopy

This review explores magnetic field-driven emergent phenomena across various material systems, emphasizing the pivotal roles of magneto-optical and nanoscopy techniques. We examine fundamental aspects of Landau electrodynamics in both 2D and 3D systems, including quantum Hall and topological magnetoelectric effects in graphene and topological insulators. Particularly attention is given to magnetic excitations and magnetopolaritons, such as surface magnon polaritons, magnetoplasmons, and magnetoexcitons in novel quantum materials, including quantum magnets and hybrid heterostructures. Advanced imaging techniques, such as scattering-type scanning near-field optical microscopy (SNOM) and microwave impedance microscopy, are showcased for their capability to resolve these phenomena with microscopic and nanoscopic resolution. These insights are complemented by discussions of advanced experimental approaches, including cryogenic environments, ultrafast pump-probe techniques, and the integration of magnetic fields into near-field optical methodologies. We further investigate the potential of these imaging techniques for unraveling complex magnetic orders, quantum phases, and correlated electronic behaviors. Finally, we offer perspectives on future research directions and highlight emerging opportunities in the evolving field of optical magneto-nanoscopy.

36 MATERIALS SCIENCE

First characterisation of the MAGO cavity, a superconducting RF detector for kHz–MHz gravitational waves

Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves (GWs) or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency GWs detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity’s GW coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

A Flux-Tunable cavity for Dark matter detection

Developing a dark matter detector with wide mass tunability is an immensely desirable property, yet it is challenging due to maintaining strong sensitivity. Resonant cavities for dark matter detection have traditionally employed mechanical tuning, moving parts around to change electromagnetic boundary conditions. However, these cavities have proven challenging to operate in sub-Kelvin cryogenic environments due to differential thermal contraction, low heat capacities, and low thermal conductivities. Instead, we develop an electronically tunable cavity architecture by coupling a superconducting 3D microwave cavity with a DC flux tunable SQUID. With a flux delivery system engineered to maintain high coherence in the cavity, we perform a hidden-photon dark matter search below the quantum-limited threshold. A microwave photon counting technique is employed through repeated quantum non-demolition measurements using a transmon qubit. With this device, we perform a hidden-photon search and constrain the kinetic mixing angle to ${\varepsilon}< 8.2\times 10^{-15}$ in a tunable band from 5.672 GHz to 5.694 GHz. By coupling multimode tunable cavities to the transmon, wider hidden-photon searching ranges are possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]

Integration of computer vision system to track the alignment SRF cavities into the test cryostat for PIP-II at Fermilab

PIP-II cryomodules use a computer vision system (H-BCAMs system) to monitor the alignment of SRF cavities and focusing lenses during assembly, testing, and operation. This contribution details the integration of the H-BCAMs into the Spoke Test Cryostat (STC) at Fermilab, which is utilized for cold testing SRF cavities prior to their integration into the string assembly. Thermal and structural finite element analyses were employed to estimate the cavities’ deformations, to be validated during cold testing in the STC using H-BCAMs. Notably, this marks the first instance of H-BCAMs integration into a cryostat and operation within a cryogenic environment.

43 PARTICLE ACCELERATORS