Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic fluid transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cryogenic system for the MYRRHA superconducting linear accelerator

SCK⋅CEN, the Belgian Nuclear Research Centre, is designing MYRRHA, a flexible fast spectrum research reactor (80 MW{sub th}), conceived as an accelerator driven system (ADS), able to operate in sub-critical and critical modes. It contains a continuous-wave (CW) superconducting (SC) proton accelerator of 600 MeV, a spallation target and a multiplying core with MOX fuel, cooled by liquid lead-bismuth (Pb-Bi). From 17 MeV onward, the SC accelerator will consist of 48 β=0.36 spoke-loaded cavities (352 MHz), 34 β=0.47 elliptical cavities (704 MHz) and 60 β=0.65 elliptical cavities (704 MHz). We present an analysis of the thermal loads and of the optimal operating temperature of the cryogenic system. In particular, the low operating frequency of spoke cavities makes their operation in CW mode possible both at 4.2 K or at 2 K. Our analysis outlines the main factors that determine at what temperature the spoke cavities should be operated. We then present different cryogenic fluid distribution schemes, important characteristics (storage, transfer line, etc.) and the main challenges offered by MYRRHA in terms of cryogenics.

43 PARTICLE ACCELERATORS↗

System and method for cooling a super-conducting device

A system and method for cooling a superconductive rotor coil. The system comprises a rotatable shaft coupled to the superconductive rotor coil. The rotatable shaft may comprise an axial passageway extending through the rotatable shaft and a first passageway extending through a wall of the rotatable shaft to the axial passageway. The axial passageway and the first passageway are operable to convey a cryogenic fluid to the superconductive rotor coil through the wall of the rotatable shaft. A cryogenic transfer coupling may be provided to supply cryogenic fluid to the first passageway.

42 ENGINEERING↗

Majorana Thermosyphon Prototype Experimental Results

Objective The Majorana demonstrator will operate at liquid Nitrogen temperatures to ensure optimal spectrometric performance of its High Purity Germanium (HPGe) detector modules. In order to transfer the heat load of the detector module, the Majorana demonstrator requires a cooling system that will maintain a stable liquid nitrogen temperature. This cooling system is required to transport the heat from the detector chamber outside the shield. One approach is to use the two phase liquid-gas equilibrium to ensure constant temperature. This cooling technique is used in a thermosyphon. The thermosyphon can be designed so the vaporization/condensing process transfers heat through the shield while maintaining a stable operating temperature. A prototype of such system has been built at PNNL. This document presents the experimental results of the prototype and evaluates the heat transfer performance of the system. The cool down time, temperature gradient in the thermosyphon, and heat transfer analysis are studied in this document with different heat load applied to the prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat Transfer Experiments and Analysis of a Simulated HTS

Long-length high temperature superconducting (HTS) cable projects, over 1 km, are being designed that are cooled by flowing liquid nitrogen. The compact counter-flow cooling arrangement which has the supply and return stream in a single cryostat offers several advantages including smallest space requirement, least heat load, and reduced cost since a return cryostat is not required. One issue in long length HTS cable systems is the magnitude of the heat transfer radially through the cable. It is extremely difficult to instrument an HTS cable in service on the grid with the needed thermometry because of the issues associated with installing thermometers on high voltage components. A 5-meter long test system has been built that simulates a counter-flow cooled, HTS cable using a heated tube to simulate the cable. Measurements of the temperatures in the flow stream and on the tube wall are presented and compared to analysis. These data can be used to benchmark different HTS cable heat transfer and fluid flow analysis approaches.

36 MATERIALS SCIENCE↗

HEAT TRANSFER EXPERIMENTS AND ANALYSIS OF A SIMULATED HTS CABLE

Long-length high temperature superconducting (HIS) cable projects, over 1 km, are being designed that are cooled by flowing liquid nitrogen. The compact counter-flow cooling arrangement which has the supply and return stream in a single cryostat offers several advantages including smallest space requirement, least heat load, and reduced cost since a return cryostat is not required. One issue in long length HIS cable systems is the magnitude of the heat transfer radially through the cable. It is extremely difficult to instrument an HIS cable in service on the grid with the needed thermometry because of the issues associated with installing thermometers on high voltage components. A 5-meter long test system has been built that simulates a counter-flow cooled, HIS cable using a heated tube to simulate the cable. Measurements of the temperatures in the flow stream and on the tube wall can be made and compared to analysis. These data can be used to benchmark different HIS cable heat transfer and fluid flow analysis approaches.

36 MATERIALS SCIENCE↗

Boil-off losses along LH2 pathway

Losses along the LH 2 pathway are intrinsic to the utilization of a cryogenic fluid. They occur when the molecule is transferred between 2 vessels (liquefaction plant to trailer, trailer to station storage, station storage to pump or compressor, then fuel cell electric vehicles …) and when the fluid is warmed up due to heat transfer with the environment. Those losses can be estimated with good accuracy using thermodynamic models based on conservation of mass and energy, providing the thermodynamic states are correctly described. Indeed, the fluid undergoes various changes as it moves along the entire pathway (2 phase transition, super-heated warming, non-uniform temperature distributions across the saturation film) and accurate equations of state and 2 phase behavior implementations are essential. The balances of mass and energy during the various dynamics processes then enable to quantify the boil-off losses. In this work, a MATLAB code previously developed by NASA to simulate rocket loading is used as the basis for the LH 2 transfer model. This code implements complex physical phenomena such as the competition between condensation and evaporation and the convection vs. conduction heat transfer as a function of the relative temperatures on both sides of the saturated film. The original code was modified to consider real gas equations of state, and some semi-empirical relationships, such as between the heat of vaporization and the critical temperature, were also replaced by a REFPROP equivalent expression, assumed to be more accurate. Non-constant liquid temperature equations were added to simulate sub-cooled conditions. It is shown that although trailer depressurization and transfer losses from the receiving vessel during a LH 2 delivery may constitute the largest sources of losses, those can be greatly reduced and even eliminated if CFR/DOT regulations are properly applied and if no-vent fill methods are implemented, particularly for a stationary LH2 storage operating at reasonably low pressure (45 psia or so). As such, it is expected that the only remaining boil-off losses for a refueling station would come from the LH 2 pump (utilization and idling), pump vessel cool down/warm up, and environment heat transfer. Based on experimental data measured at LLNL on the Linde 875 bar LH 2 cryo-pump and results from the model, and extrapolating for refueling stations of various sizes, it can be shown that boil-off losses can vary from 15% of delivered LH 2 for a 100 kg/day, 5% at 400 kg/day, and down to less than 2% for stations above 1,800 kg/day (for a system similar to the one at LLNL). Less boil-off is to be expected for LH 2 pumps dispensing at 350 bar, so that less than 0.7% can be expected above 1,800 kg/day station capacities. At last, boil-off recovery solutions are briefly analyzed, including compressors, cryo-coolers and stationary fuel cell. Their economic value is strongly related to the costs of H2 and of the electricity needed to perform the recovery, on top of the initial capital expenditures. Effective boil-off could be reduced to 0.6-1% for a 2,000 kg/day station if adequate recovery solutions are used.

08 HYDROGEN↗

STABILITY ANALYSIS OF THE ITER TF CONDUCTOR

The stability analysis of the reference Nb{sub 3}Sn conductor for the International Thermonuclear Experimental Reactor (ITER) Toroidal Field (TF) coils is performed using the Mithrandir code. From the point of view of the temperature margin, the most critical conductor in the winding pack, as well as the most critical location along it, is identified by a Vincenta code analysis, which also provides the initial and boundary conditions for the stability study. With this approach, the 1D Mithrandir analysis can be restricted to the most critical conductor, using a much finer grid than Vincenta, in order to capture the details of normal zone initiation and possible recovery to SC state. Two different disturbances are considered: one short in space and time (0.01 m, 1 ms), simulating a disturbance of mechanical nature, the other longer (3 m, 100 ms), corresponding to AC losses (plasma disruption). Both disturbances are applied to the superconducting cable at end-of-burn, in the reference ITER inductive operation scenario. The grid-independence of the results was verified first. Since the results are strongly influenced by the choice of the heat transfer coefficient between strands and helium, this effect has been also parametrically investigated. In all cases, the computed minimum quench energies turn out to be above the level of the expected disturbances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICRO-SCALE CFD MODELING OF OSCILLATING FLOW IN A REGENERATOR

Regenerator models used by designers are macro-scale models that do not explicitly consider interactions between the fluid and the solid matrix. Rather, the heat transfer coefficient and pressure drop are calculated using correlations for Nusselt number and friction factor. These correlations are typically based on steady flow data. The error associated with using steady flow correlations to characterize the oscillatory flow that is actually present in the regenerator is not well understood. Oscillating flow correlations based on experimental data do exist in the literature; however, these results are often conflicting. This paper uses a micro-scale computational fluid dynamic (CFD) model of a unit-cell of a regenerator matrix to determine the conditions for which oscillating flow affects friction factor. These conditions are compared to those found in typical pulse tube regenerators to determine whether oscillatory flow is of practical importance. CFD results clearly show a transition Valensi number beyond which oscillating flow significantly increases the friction factor. This transition Valensi number increases with Reynolds number. Most practical pulse tube regenerators will operate below this Valensi transition number and therefore this study suggests that the effect of flow oscillation on pressure drop can be neglected in macro-scale regenerator models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated cryogenic refilling system

An improved system and method for the automated refilling of cryogenic helium is provided. In one embodiment, the system includes a dewar in fluid communication with a liquid helium cryostat through a cryogen transfer line. A controller regulates operation of a three-way valve to pre-cool the transfer line and to cause gaseous helium to flow to the dewar and force liquid helium through the transfer line into the cryostat. The controller is coupled to the output of a cryogenic level sensor, such that the controller regulates the helium liquid level within the cryostat. During filling cycles, the dewar liquid level is also monitored by the cryogenic level sensor and an alarm sounds if the dewar liquid level is undesirably low. Between filling cycles, the controller is operable to ventilate the dewar through a solenoid vent valve in fixed time intervals to ensure the dewar pressure is sufficiently low so as to not bleed liquid helium into the cryostat.

Ruiz-Rodriguez, Mariano M.↗

NEW MODEL AND MEASUREMENT PRINCIPLE OF FLOWING AND HEAT TRANSFER CHARACTERISTICS OF REGENERATOR

Regenerators play key role in oscillating-flow cryocoolers or thermoacoustic heat engine systems. However, their flowing and heat transfer mechanism is still not well understood. The complexities of the oscillating flow regenerator make traditional method of heat transfer research become difficult or helpless. In this paper, a model for porous media regenerator was given based on the linear thermoacoustic theory. Then the correlations for characteristic parameters were obtained by deducing universal expressions for thermoacoustic viscous function F{sub v} and thermal function F{sub T}. A simple acoustical method and experimental system to get F{sub v} and F{sub T} via measurements of isothermal regenerators were presented. Some measurements of packed stainless screen regenerators were performed, and preliminary experimental results for flow and convective coefficients were derived, which showing flowing friction factor is approximately within 132/Re to 173/Re.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of CO{sub 2} condensation process using cryogen

Carbon dioxide (CO{sub 2}) is one of the dominant gas molecules that causes greenhouse effect, i.e. global warming. Numerous studies have been carried out to regulate the emission of CO{sub 2} to reduce greenhouse gas. The liquid CO{sub 2} is a convenient form of transportation compared to high-pressurized gaseous CO{sub 2}. Therefore, the direct liquefaction mechanism of CO{sub 2} at low temperature draws technical attention recently. In particular, cold thermal energy of Liquefied Natural Gas (LNG) could be a candidate to condense gaseous CO{sub 2}, especially in the LNG powered ship. In this paper, the detailed direct condensation process of CO{sub 2} using LN{sub 2} with intermittent solidification is investigated. Pressurized CO{sub 2} at 600 kPa is directly liquefied in a vessel by liquid nitrogen which is supplied into the coiled tube heat exchanger inside the CO{sub 2} vessel. The heat exchanger temperature is controlled from 130 K to 205 K to regulate the solidification and sublimation of CO{sub 2} by duty control with cryogenic solenoid valve. The characteristics of CO{sub 2} condensation process with cryogen are analyzed from the measurement results. The results show that the solidification causes the significant degradation of CO{sub 2} condensation heat transfer. Finally, the condensation rate with and without solidification is compared.

42 ENGINEERING↗

CFD MODELING OF ITER CABLE-IN-CONDUIT SUPERCONDUCTORS. PART V: COMBINED MOMENTUM AND HEAT TRANSFER IN RIB ROUGHENED PIPES

Computational Fluid Dynamics (CFD) techniques have been proposed and applied in a series of papers to analyze cable-in-conduit conductors (CICC) for the International Thermonuclear Experimental Reactor (ITER). Previous work on the pressure drop in the central channel of ITER CICC is extended here to the problem of combined heat and momentum transfer. The CFD model, solved by the FLUENT commercial code, is first validated against 2D and 3D data from compact heat exchangers, showing good agreement. The Colburn analogy between the friction factor f and the Nusselt number Nu is not verified in the considered 2D geometries, as shown by both experiment and simulation. The validated CFD model is finally applied to the 3D analysis of central channel-like geometries relevant for ITER CICC. It is shown that the heat transfer coefficient on the central channel side stays relatively close to the smooth-pipe (Dittus-Boelter) value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Ulta-Efficient Electric Motors

Electric motors utilize a large amount of electrical energy in utility and industrial applications. Electric motors constructed with high temperature superconducting (HTS) materials have the potential to dramatically reduce electric motor size and losses. HTS motors are best suited for large motor applications at ratings above 1000 horsepower (hp), where the energy savings from the efficiency improvement can overcome the additional power required to keep the superconductors on the rotor cooled. Large HTS based motors are expected to be half the volume and have half the losses of conventional induction motors of the same rating. For a 5000 hp industrial motor, this energy savings can result in $50,000 in operating cost savings over the course of a single year of operation. Since large horsepower motors utilize (or convert) about 30% of the electrical power generated in the United States and about 70% of large motors are candidates for replacement by HTS motors, the annual energy savings potential through the utilization of HTS motors can be up to $1 Billion in the United States alone. Research in the application of HTS materials to electric motors has lead to a number of HTS motor prototypes yet no industrial HTS motor product has yet been introduced. These motor demonstrations have been synchronous motors with HTS field windings, on the rotor. Figure 1-1 shows a solid model rendering of this type of motor. The rotor winding is made with HTS coils that are held at cryogenic temperature by introducing cooling fluid from the cryocooler to the rotor through a transfer coupling. The stator winding is made of copper wire. The HTS winding is thermally isolated from the warm armature and motor shafts by a vacuum insulation space and through the use of composite torque tubes. The stator in Figure 1-1 is an air core stator in that the stator teeth and a small part of the yoke is made up of nonmagnetic material so the magnetic fields distribute themselves as if in air. Between the HTS field winding and the physical air gap is a series of concentric cylinders that act as vacuum insulation space walls as well as conducting paths for induced currents to flow in order to shield the HTS winding and the rotor cold space from time dependent fields. These time dependent fields may be caused by rotor hunting, during a change in motor load, or by non-fundamental component voltages and currents applied by the inverter. These motors are variable speed controlled by the inverter. Common large motor utility and industrial applications are pump and fan drives that are best suited by a variable speed motor. Inverter control of the HTS motor eliminates the need to design the rotor for line starting, which would dump a large amount of heat into the rotor that would then heavily tax the cryogenic cooling system. The field winding is fed by a brushless exciter that provides DC current to the HTS rotor winding. The stator winding is air or water cooled. Technical and commercial hurdles to industrial HTS motor product introduction and customer acceptance include (1) the high cost of HTS wire and the cryogenic cooling system components, (2) customer concerns about reliability of HTS motors, and (3) the ability to attain the loss reduction potential of large HTS motors. Reliance Electric has demonstrated a number of HTS based electric motors up to a 1000 hp, variable speed synchronous motor with an HTS field winding in the year 2000. In 2001 this motor was tested to 1600 hp with a sinusoidal (constant frequency) supply. Figure 1-2 shows the HTS motor on the dynamometer test stand in the Reliance Electric test lab. The extensive test program of the 1000 hp motor successfully demonstrated the technical feasibility of large HTS motors and the basic technologies involved, however the test results did indicate the need for design refinements. In addition, test results served to identify other more fundamental critical technology issues, and revealed the need to continue research efforts in order to improve future HTS motor first cost, reliability, and performance. The lessons learned from the development and testing of the 1000 hp motor were the basis for the tasks proposed for the project that is being described in this final report. These eight tasks and the technology and commercial issues they address are listed in Table 1-1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cryogenic system with GM cryocooler for krypton, xenon separation from hydrogen-helium purge gas

In the thorium molten salt reactor (TMSR), fission products such as krypton, xenon and tritium will be produced continuously in the process of nuclear fission reaction. A cryogenic system with a two stage GM cryocooler was designed to separate Kr, Xe, and H{sub 2} from helium purge gas. The temperatures of two stage heat exchanger condensation tanks were maintained at about 38 K and 4.5 K, respectively. The main fluid parameters of heat transfer were confirmed, and the structural heat exchanger equipment and cold box were designed. Designed concentrations after cryogenic separation of Kr, Xe and H{sub 2} in helium recycle gas are less than 1 ppb.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

THE LIQUID NITROGEN SYSTEM FOR CHAMBER A; A CHANGE FROM ORIGINAL FORCED FLOW DESIGN TO A NATURAL FLOW (THERMO SIPHON) SYSTEM

NASA at the Johnson Space Center (JSC) in Houston is presently working toward modifying the original forced flow liquid nitrogen cooling system for the thermal shield in the space simulation chamber-A in Building 32 to work as a natural flow (thermo siphon) system. Chamber A is 19.8 m (65 ft) in diameter and 35.66 m (117 ft) high. The LN{sub 2} shroud environment within the chamber is approximately 17.4 m (57 ft) in diameter and 28 m (92 ft) high. The new thermo siphon system will improve the reliability, stability of the system. Also it will reduce the operating temperature and the liquid nitrogen use to operate the system. This paper will present the requirements for the various operating modes. System level thermodynamic comparisons of the existing system to the various options studied and the final option selected will be outlined. A thermal and hydraulic analysis to validate the selected option for the conversion of the current forced flow to natural flow design will be discussed. The proposed modifications to existing system to convert to natural circulation (thermo siphon) system and the design features to help improve the operations, and maintenance of the system will be presented.

42 ENGINEERING↗

Characterization of Bypass Fluid Flow in an Active Magnetic Regenerative Liqueer

Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass unbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. While researchers have been aware of this phenomenon for decades, experimental performance improvements from bypass fluid flow have yet to be reported in open literature. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a function of the bypass ow fraction. Experiments are performed at a fixed temperature span that yield a 25% improvement in net cooling power, affirming the potential of bypass cooling power.

active magnetic regenerator, hydrogen, liquefacati↗

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗