Search NASA⌕ Search

SEARCH · Search NASA

Results for “crystal positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic X-ray diffraction sampling for protein crystal positioning

A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscopic strain evolution in single-crystal battery positive electrodes

Single-crystal Ni-rich layered oxides (SC-NMC) with a grain-boundary-free configuration have effectively addressed the long-standing cracking issue of conventional polycrystalline Ni-rich materials (PC-NMC) in lithium-ion batteries, prompting a shift in optimization strategies. However, continued reliance on anisotropic lattice volume change—a well-established failure indicator in PC-NMC—as a metric for understanding strain and guiding compositional design for SC-NMC becomes controversial. Here, in this study, by leveraging multiscale diagnostic techniques, we unravelled the distinct nanoscopic strain evolution in SC-NMC during battery operation, challenging the conventional composition-driven strategies and mechanical degradation indicators used for PC-NMC. Through particle-level chemomechanical analysis, we reveal a decoupling between mechanical stability and lattice volume change in SC-NMC, identifying that structural instability in SC materials is primarily driven by multidimensional lattice distortions induced by kinetics-driven reaction heterogeneity and progressively deactivating chemical phases. Using this mechanical failure mode, we redefine the roles of cobalt and manganese in maintaining mechanical stability. Unlike cobalt’s detrimental role in PC-NMC, we find cobalt to be critical in enhancing the longevity of SC-NMC by mitigating localized strain along the extended diffusion pathway, whereas manganese exacerbates mechanical degradation.

36 MATERIALS SCIENCE↗

On Forbidden Positions in Crystal Space

The finiteness of atomic volumes and symmetry impose limitations on the positions in crystal space that are allowed for occupation when crystal atomic structures are formed. The results of studying the geometric features of the forbidden regions of crystal space are presented. A new classification of symmetry space groups, based on the symmetry of crystal space forbidden regions, is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The interaction of 193-nm excimer laser irradiation with single-crystal zinc oxide: Positive ion emission

We examine UV laser-induced ion emission from a wide bandgap semiconductor, single-crystal ZnO, at fluences well below both the damage threshold and plasma formation. At fluences below 200 mJ/cm{sup 2}, we observe only Zn{sup +}, and the Zn{sup +} intensity decreases monotonically during exposure. At higher fluences, after an initial decrease, the emission is sustained; in addition O{sup +} and O{sub 2}{sup +} are observed. We explain: how Zn ions of several eV in energy can be produced on the surface of a semiconductor, how sustained emission can be maintained, and the origin of an anomalous emission of slow Zn{sup +} ions -- the latter is shown to arise from photoionization of atomic Zn, also emitted by this radiation.

36 MATERIALS SCIENCE↗

Finding a Cold Needle in a Warm Haystack: Infrared Imaging Applied to Locating Cryocooled Crystals in Loops

We demonstrate the use of inbred imaging to locate crystals mounted in cryoloops and cryopreserved in a nitrogen gas stream at 100K. In the home laboratory crystals are clearly seen in the infrared images with light transmitting through the sample while irradiating the crystal from behind, and with illumination from a direction perpendicular to the direction of view. The crystals transmit and reflect infrared radiation differently from the surrounding mother liquor and loop. Because of differences in contrast between crystals and their surrounding mother liquor, it is possible to clearly identify the crystal position. In use at the synchrotron, with robotically mounted crystals the small depth of field of the lens required the recording of multiple images at different focal points. Image processing techniques were then used to produce a clear image of the crystal. The resulting infrared images and intensity profiles show that infrared imaging can be a powerful complement to visual imaging in locating crystals in cryocooled loops.

Snell, E. H.↗

Optimal feedback in efficient ring double-cavity optical parametric oscillators

It is shown that the use of two feedback circuits with matched transfer constants and optimal phase incursions in a nondegenerate optical parametric oscillator (OPO) makes it possible to localise the extremes of intensity distributions of interacting waves on the output face of a nonlinear crystal, which provides maximum possible conversion efficiency of pump energy. The optimisation procedure in this case is rather flexible because it is reduced to ambiguous matching of the period and shift of the extremes of exact analytic solutions of the corresponding problem in the form of cnoidal waves with respect to the nonlinear crystal position. Unlike the single-cavity OPO scheme, both these parameters can substantially exceed the nonlinear crystal length and even tend to infinity, which corresponds to solitary soliton-like solutions. (optical parametric oscillators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pressure sensor using liquid crystals

A pressure sensor includes a liquid crystal positioned between transparent, electrically conductive films (18 and 20), that are biased by a voltage (V) which induces an electric field (E) that causes the liquid crystal to assume a first state of orientation. Application of pressure (P) to a flexible, transparent film (24) causes the conductive film (20) to move closer to or farther from the conductive film (18), thereby causing a change in the electric field (E'(P)) which causes the liquid crystal to assume a second state of orientation. Polarized light (P.sub.1) is directed into the liquid crystal and transmitted or reflected to an analyzer (A or 30). Changes in the state of orientation of the liquid crystal induced by applied pressure (P) result in a different light intensity being detected at the analyzer (A or 30) as a function of the applied pressure (P). In particular embodiments, the liquid crystal is present as droplets (10) in a polymer matrix (12) or in cells (14) in a polymeric or dielectric grid (16) material in the form of a layer (13) between the electrically conductive films (18 and 20). The liquid crystal fills the open wells in the polymer matrix (12) or grid (16) only partially.

Parmar, Devendra S.↗

Getting the Most Out of Your Crystals: Data Collection at the New High-Flux, Microfocus MX Beamlines at NSLS-II

Advances in synchrotron technology are changing the landscape of macromolecular crystallography. The two recently opened beamlines at NSLS-II—AMX and FMX—deliver high-flux microfocus beams that open new possibilities for crystallographic data collection. They are equipped with state-of-the-art experimental stations and automation to allow data collection on previously intractable crystals. Optimized data collection strategies allow users to tailor crystal positioning to optimally distribute the X-ray dose over its volume. Vector data collection allows the user to define a linear trajectory along a well diffracting volume of the crystal and perform rotational data collection while moving along the vector. This is particularly well suited to long, thin crystals. We describe vector data collection of three proteins—Akt1, PI3Kα, and CDP-Chase—to demonstrate its application and utility. For smaller crystals, we describe two methods for multicrystal data collection in a single loop, either manually selecting multiple centers (using H108A-PHM as an example), or “raster-collect”, a more automated approach for a larger number of crystals (using CDP-Chase as an example).

59 BASIC BIOLOGICAL SCIENCES↗

Effect of thermal processes on critical operation conditions of high-power laser diodes

Using numerical and analytical techniques in a threedimensional approximation, we have modelled the effect of spatial thermoelastic stress nonuniformity in a laser diode – heat sink system on the output characteristics of the device in different operation modes. We have studied the influence of the pulse duration, the geometry of the laser system and its thermophysical parameters on the critical pump current density, in particular for state-of-the-art heat conductive substrate materials. The proposed approach has been used to optimise the laser diode assembly process in terms of the quality of laser crystal positioning (bonding) on a heat sink. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that produce very high extinction ratios in the FUV spectral range (100-200 nm). This polarizer consists of reflecting light through a series of mirrors from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the average LiF Brewster’s angle in the FUV. The output is a highly linearly polarized beam. This polarizer concept was fabricated and tested in the existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing using a MgF2 crystal at the Brewster’s angle as an analyzer has shown that this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm, and that the measured extinction ratio of the two crossed polarizers, ≈114, is mostly limited by the MgF2 analyzer. A polarizer with such a performance at this wavelength has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the polarizer’s compact design allows for a new polarizer capability that would one day be implemented in a future FUV spectropolarimetry space mission.

Far Ultraviolet (FUV)↗

Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications

Purpose: Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. Methods: The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm{sup 3} LYSO, a 7 × 7 array of 3 × 3 × 20 mm{sup 3} LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm{sup 3} LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm{sup 3} LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. Results: This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. Conclusions: The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positioning Vise for Crystal Cleavage

Vise manipulates brittle crystals, such as lithium fluoride, so they are in proper position for cleaving. Vise allows crystals as thin as 2 millimeters or less positioned so that cleaved without breakage. Vise holds workpiece firmly but gently. Bushings, shafts and adjusting screw designed to move jaws smoothly and uniformly with great tactile sensitivity.

Hallberg, F. C.↗

Guiding synchrotron X-ray diffraction by multimodal video-rate protein crystal imaging

Synchronous digitization, in which an optical sensor is probed synchronously with the firing of an ultrafast laser, was integrated into an optical imaging station for macromolecular crystal positioning prior to synchrotron X-ray diffraction. Using the synchronous digitization instrument, second-harmonic generation, two-photon-excited fluorescence and bright field by laser transmittance were all acquired simultaneously with perfect image registry at up to video-rate (15 frames s –1 ). A simple change in the incident wavelength enabled simultaneous imaging by two-photon-excited ultraviolet fluorescence, one-photon-excited visible fluorescence and laser transmittance. Development of an analytical model for the signal-to-noise enhancement afforded by synchronous digitization suggests a 15.6-fold improvement over previous photon-counting techniques. This improvement in turn allowed acquisition on nearly an order of magnitude more pixels than the preceding generation of instrumentation and reductions of well over an order of magnitude in image acquisition times. These improvements have allowed detection of protein crystals on the order of 1 µm in thickness under cryogenic conditions in the beamline. Lastly, these capabilities are well suited to support serial crystallography of crystals approaching 1 µm or less in dimension.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Co on Fe{sub 3}O{sub 4}(001): Towards precise control of surface properties

A novel approach to incorporate cobalt atoms into a magnetite single crystal is demonstrated by a combination of x-ray spectro-microscopy, low-energy electron diffraction, and density-functional theory calculations. Co is deposited at room temperature on the reconstructed magnetite (001) surface filling first the subsurface octahedral vacancies and then occupying adatom sites on the surface. Progressive annealing treatments at temperatures up to 733 K diffuse the Co atoms into deeper crystal positions, mainly into octahedral ones with a marked inversion level. The oxidation state, coordination, and magnetic moments of the cobalt atoms are followed from their adsorption to their final incorporation into the bulk, mostly as octahedral Co{sup 2+}. This precise control of the near-surface Co atoms location opens up the way to accurately tune the surface physical and magnetic properties of mixed spinel oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of europium substitution for In on structure and photoelectric properties of CuIn{sub 1−x}Eu{sub x}Te{sub 2}

The structures and optical and electric properties of europium doped CuIn{sub 1−x}Eu{sub x}Te{sub 2} have been studied systematically using powder X-ray diffraction (XRD), scanning electron microscopy (SEM) with energy dispersive spectrum (EDS), ultraviolet and visible spectrophotometer (UV–vis), and standard four-probe method. The studies reveal that the minor europium doping into CuIn{sub 1−x}Eu{sub x}Te{sub 2} could still stabilize the chalcopyrite structure in a solid solution of x=0.1. The lattice parameters are going up with increasing the content of europium in CuIn{sub 1−x}Eu{sub x}Te{sub 2} due to the size effect at In site. The structural refinement confirms that Eu partly substitutes for In and occupies the 4b crystal position. SEM morphologies show that the europium doping into CuIn{sub 1−x}Eu{sub x}Te{sub 2} can fine the grains from the largely agglomerated state to the uniformly separated state. The electrical resistivities of single phase CuIn{sub 1−x}Eu{sub x}Te{sub 2} follow a mixture model of hopping conductivity and variable range hopping conductivity. The absorption band-gaps of CuIn{sub 1−x}Eu{sub x}Te{sub 2} at room temperature tend to increase with increasing Eu content. CuIn{sub 1−x}Eu{sub x}Te{sub 2} might be a good candidate for photovoltaic cell. - Graphical abstract: CuIn{sub 0.9}Eu{sub 0.1}Te{sub 2} follows a mixture of hopping conductivity and variable range hopping conductivity mechanism. - Highlights: • Novel europium doped CuIn{sub 1−x}Eu{sub x}Te{sub 2}. • Potential application for devices and solar cells. • A mixture of hopping and variable range hopping conductivity mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗