Search NASA⌕ Search

SEARCH · Search NASA

Results for “current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Current measurements in the intermittent-contact mode of atomic force microscopy using the Fourier method: a feasibility analysis

Atomic force microscopy (AFM) is an important tool for measuring a variety of nanoscale surface properties, such as topography, viscoelasticity, electrical potential and conductivity. Some of these properties are measured using contact methods (static contact or intermittent contact), while others are measured using noncontact methods. Some properties can be measured using different approaches. Conductivity, in particular, is mapped using the contact-mode method. However, this modality can be destructive to delicate samples, since it involves continuously dragging the cantilever tip on the surface during the raster scan, while a constant tip–sample force is applied. In this paper we discuss a possible approach to develop an intermittent-contact conductive AFM mode based on Fourier analysis, whereby the measured current response consists of higher harmonics of the cantilever oscillation frequency. Such an approach may enable the characterization of soft samples with less damage than contact-mode imaging. To explore its feasibility, we derive the analytical form of the tip–sample current that would be obtained for attractive (noncontact) and repulsive (intermittent-contact) dynamic AFM characterization, and compare it with results obtained from numerical simulations. Although significant instrumentation challenges are anticipated, the modelling results are promising and suggest that Fourier-based higher-harmonics current measurement may enable the development of a reliable intermittent-contact conductive AFM method.

14 SOLAR ENERGY↗

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells

X-ray beam induced current (XBIC) measurements allow mapping of the nanoscale performance of electronic devices such as solar cells. Ideally, XBIC is employed simultaneously with other techniques within a multi-modal X-ray microscopy approach. An example is given herein combining XBIC with X-ray fluorescence to enable point-by-point correlations of the electrical performance with chemical composition. For the highest signal-to-noise ratio in XBIC measurements, lock-in amplification plays a crucial role. By this approach, the X-ray beam is modulated by an optical chopper upstream of the sample. The modulated X-ray beam induced electrical signal is amplified and demodulated to the chopper frequency using a lock-in amplifier. By optimizing low-pass filter settings, modulation frequency, and amplification amplitudes, noise can efficiently be suppressed for the extraction of a clear XBIC signal. A similar setup can be used to measure the X-ray beam induced voltage (XBIV). Beyond standard XBIC/XBIV measurements, XBIC can be measured with bias light or bias voltage applied such that outdoor working conditions of solar cells can be reproduced during in-situ and operando measurements. Ultimately, the multi-modal and multi-dimensional evaluation of electronic devices at the nanoscale enables new insights into the complex dependencies between composition, structure, and performance, which is an important step towards solving the materials' paradigm.

14 SOLAR ENERGY↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

A round bobbin critical current measurement and thermal runaway simulation of REBCO coated conductors

A round bobbin test has been widely used to measure critical current Ic of practical superconductors including Nb–Ti, Nb3Sn, and Bi-2212 round strands at 4.2 K and in high magnetic fields but rarely used for rare earth-barium-copper-oxide (REBCO) coated conductor tapes. Here, we applies this method to REBCO tapes and test their Ic at 77 K, self-field, and 4.2 K with a magnetic field of 14 T applied parallel to the tape. The sample carries very high current densities; it is 1.3 m long and has a dense array of voltage taps that allows probing localized thermal runaways and correlation with Ic variations along the length. At 77 K, the Ic values of all sections were measured and found to be rather uniform. However, at 4.2 K, we found that a 3 cm section has 90% of the overall voltage drop and it went into thermal runaways upon further increasing current. Thus, at 4.2 K, we were prevented by localized thermal runaways and unable to determine Ic of most of the REBCO conductor sections; this behavior is different from Bi-2212 and Bi-2223 for which Ic of all turns of a round barrel sample can be determined. We simulate REBCO tapes during current ramping to a thermal runaway and analyze impacts of various factors including cooling, conductor n-values, and thickness of stabilizer on the thermal runaway current Iq. The combined experiments and simulations identify n-value as a crucial factor that leads to the observed differences between Bi-2212 and REBCO. Together with cooling and the standard deviation of Ic variations along the length, the n-value determines whether Iq is above or below the average Ic of a long piece of conductor and their ratio Iq/Ic,ave, greatly affecting quench detection and thermal runaway prevention strategies of Bi-2212 and REBCO magnets.

Mosat, Marek↗

A tunneling current measurement scheme to observe Majorana-zero-mode-induced crossed Andreev reflection

We propose a scheme to observe the Majorana-zero-mode-induced crossed Andreev reflection by measuring tunneling current directly. In this scheme a metallic ring structure is utilized to separate electron and hole signals. Since tunneling electrons and holes have different propagating wave vectors, the conditions for them to be constructively coherent in the ring differ. We find that when the magnetic flux threading the ring varies, it is possible to observe adjacent positive and negative tunneling current peaks of about equal amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Minority carrier lifetime and dark current measurements in mid-wavelength infrared InAs 0.91 Sb 0.09 alloy nBn photodetectors

Carrier lifetime and dark current measurements are reported for a mid-wavelength infrared InAs 0.91 Sb 0.09 alloy nBn photodetector. Minority carrier lifetimes are measured using a non-contact time-resolved microwave technique on unprocessed portions of the nBn wafer and the Auger recombination Bloch function parameter is determined to be |F 1 F 2 |=0.292. Moreover, the measured lifetimes are also used to calculate the expected diffusion dark current of the nBn devices and are compared with the experimental dark current measured in processed photodetector pixels from the same wafer. As a result, excellent agreement is found between the two, highlighting the important relationship between lifetimes and diffusion currents in nBn photodetectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass transport limitations in polymer electrolyte water electrolyzers using spatially-resolved current measurement

Here this work utilizes spatially-resolved current measurements to provide insight into mass transport limitations in electrolyzers that are not observable from traditional polarization measurement. In this study, two types of flow-fields (parallel and triple-serpentine) and two types of diffusion media (patterned porous thin titanium foil LGDLs and Ir-coated titanium felt PTLs) were examined. A non-uniform current distribution dominated by mass transport limitations was observed to be instigated by the restriction of liquid water transport to catalyst sites. Additionally, conditions are revealed which yield similar polarization performance but dissimilar current distributions. In such cases, the transport limitations for different architectures and porous media affect polarization in different regions of the active area. Furthermore, the triple-serpentine flow-field used in this study performs better than the parallel flow-field under mass transport limited operating conditions. This indicates that the parallel flow-field used in this study is more susceptible to starvation than the triple-serpentine flow-field for the electrolyzer studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

Precision Absolute Beam Current Measurement of Low Power Electron Beam

Precise measurements of low power CW electron beam current for the Jefferson Lab Nuclear Physics program have been performed using a Tungsten calorimeter. This paper describes the rationale for the choice of the calorimeter technique, as well as the design and calibration of the device. The calorimeter is in use presently to provide a 1% absolute current measurement of CW electron beam with 50 to 500 nA of average beam current and 1-3 GeV beam energy. Results from these recent measurements will also be presented.

43 PARTICLE ACCELERATORS↗

High-Speed and High-Power Ferroelectric Switching Current Measurement Instrument for Materials with Large Coercive Voltage and Remanent Polarization

A high-speed and high-power current measurement instrument is described for measuring rapid switching of ferroelectric samples with large spontaneous polarization and coercive field. Instrument capabilities (±200 V, 200 mA, and 200 ns order response) are validated with a LiTaO 3 single crystal whose switching kinetics are well known. The new instrument described here enables measurements that are not possible using existing commercial measurement systems, including the observation of ferroelectric switching in large coercive field and large spontaneous polarization Al 0.7 Sc 0.3 N thin films.

30 DIRECT ENERGY CONVERSION↗

Depletion region surface effects in electron beam induced current measurements

Electron beam induced current (EBIC) is a powerful characterization technique which offers the high spatial resolution needed to study polycrystalline solar cells. Current models of EBIC assume that excitations in the p-n junction depletion region result in perfect charge collection efficiency. However, we find that in CdTe and Si samples prepared by focused ion beam (FIB) milling, there is a reduced and nonuniform EBIC lineshape for excitations in the depletion region. Motivated by this, we present a model of the EBIC response for excitations in the depletion region which includes the effects of surface recombination from both charge-neutral and charged surfaces. For neutral surfaces, we present a simple analytical formula which describes the numerical data well, while the charged surface response depends qualitatively on the location of the surface Fermi level relative to the bulk Fermi level. We find that the experimental data on FIB-prepared Si solar cells are most consistent with a charged surface and discuss the implications for EBIC experiments on polycrystalline materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HIGH DYNAMIC-RANGE HIGH SPEED LINAC CURRENT MEASUREMENTS

It is desired to measure the linac current of a charged particle beam with a consistent accuracy over a dynamic range of over 120 dB. Conventional current transformers suffer from droop, can be susceptible to electromagnetic interference (EMI), and can be bandwidth limited. A novel detector and electronics were designed to maximize dynamic range of about 120 dB and measure rise-times on the order of 10 nanoseconds.

Deibele, Craig Edmond↗

Spurious phenomena occurring during current measurement on ultra-thin dielectric layers: From electro-thermal effects to surface damage

In this paper, the conduction properties of dielectric ultra-thin layers are studied using atomic force microscopy. Especially, the conductive-atomic force microscope allows to measure the leakage current at the nanoscale and to study the degradation mechanisms locally. Nonetheless, the dielectric layer seems to be damaged by a technique's specific phenomenon: hillocks appear when a positive tip bias is applied on different dielectrics. In this paper, the formation of these hillocks is studied. Contrary to what is observed during the dielectric breakdown, the conductivity is reduced after hillocks formation which occurs after the dielectric breakdown. Moreover, we have observed the formation of cavities in the silicon substrate linked to the formation of hillocks, which is not compatible with a swelling process (as dielectric breakdown induced epitaxy). We propose that these results may be explained by an electro-thermal effect due to the large dissipated energy, maybe combined with the oxidation of the substrate. Finally, the interdependence of measurements is demonstrated during serial acquisition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of outer flaws in titanium alloys using eddy current measuring system

In this paper results of shallow outer flaw detection in thick titanium alloy specimens is presented. In order to increase efficiency of inspections of minor defects an eddy current measuring system with a lock-in amplifier was used. The measurements were carried out for flat and cylindrical specimens with artificial flaws.

36 MATERIALS SCIENCE↗

On Leakage Current Measured at High Cell Voltages in Lithium-Ion Batteries

In this study, parasitic side reactions in lithium-ion batteries were examined experimentally using a potentiostatic hold at high cell voltage. The experimental leakage current measured during the potentiostatic hold was compared to the Tafel expression and showed poor agreement with the expected transfer coefficient values, indicating that a more complicated expression could be needed to accurately capture the physics of this side reaction. Here we show that cross-talk between the electrodes is the primary contribution to the observed leakage current after the relaxation of concentration gradients has ceased. This cross-talk was confirmed with experiments using a lithium-ion conducting glass ceramic (LICGC) separator, which has high conductance only for lithium cations. The cells with LICGC separators showed significantly less leakage current during the potentiostatic hold test compared to cells with standard microporous separators where cross-talk is present. In addition, direct-current pulse power tests show an impedance rise for cells held at high potentials and for cells held at high temperatures, which could be attributed to film formation from the parasitic side reaction. Based on the experimental findings, a phenomenological mechanism is proposed for the parasitic side reaction which accounts for cross-talk and mass transport of the decomposition products across the separator.

25 ENERGY STORAGE↗

Fault Detection and Diagnosis In Hall–Héroult Cells Based on Individual Anode Current Measurements Using Dynamic Kernel PCA

Individual anode current signals in aluminum reduction cells provide localized cell conditions in the vicinity of each anode, which contain more information than the conventionally measured cell voltage and line current. One common use of this measurement is to identify process faults that can cause significant changes in the anode current signals. While this method is simple and direct, it ignores the interactions between anode currents and other important process variables. This paper presents an approach that applies multivariate statistical analysis techniques to individual anode currents and other process operating data, for the detection and diagnosis of local process abnormalities in aluminum reduction cells. Specifically, since the Hall–Héroult process is time-varying with its process variables dynamically and nonlinearly correlated, dynamic kernel principal component analysis with moving windows is used. The cell is discretized into a number of subsystems, with each subsystem representing one anode and cell conditions in its vicinity. The fault associated with each subsystem is identified based on multivariate statistical control charts. The results show that the proposed approach is able to not only effectively pinpoint the problematic areas in the cell, but also assess the effect of the fault on different parts of the cell.

36 MATERIALS SCIENCE↗

Interlaboratory Comparisons of NbTi Critical Current Measurements

We report on a multi-institute comparison of critical current data measured on a modern NbTi wire for the Large Hadron Collider (LHC), which has shown a standard deviation below 1% in critical current density spread in more than 1500 measurements. Interlaboratory comparisons on Nb{sub 3}Sn wires have shown ambiguities that could be attributable to strain related differences in critical current density, originating from differences in sample handling, reaction, and mounting techniques, or also to differences in the magnetic field and current calibrations between the institutes. A round robin test of a well characterized NbTi wire provides a baseline variance in critical current results that is presumed to be attributable only to differences in the characterization systems. Systematic differences on the order of 3.5% are found in the comparison. The most likely cause for the observed differences is a small diameter holder that brings the wire into a strain regime in which strain effects can no longer be ignored. A NbTi round robin test, when performed properly, will separate system differences from sample specific differences and provide laboratories with an opportunity to calibrate equipment against a standard measurement.

43 PARTICLE ACCELERATORS↗

Coincidence of the Measured Voltage Peak and the Measured Current Inflection Point in Exploding Metals

Exploding Bridgewire (EBW) Detonators and Exploding Foil Initiators (EFI's, e.g. Slappers) have unique current and voltage characteristics marked by a large voltage spike and an inflection point in the current. Mathematically, it is shown that the voltage peak and the current inflection point must align in time. Models concur with the math and show voltage peaks occurring at the same point in time as the inflection point. Circuit analysis is performed to demonstrate why the voltage peak and current inflection point will almost never align in time for an experiment. To correctly analyze exploding metal behavior, the current inflection point and voltage peak must be manually aligned in time. These conclusions apply to single detonators where current and voltage is measured on those detonators. In multi-detonator systems, the conclusions herein apply only for cases where current and voltage are obtained for each detonator individually. The conclusions will begin to break down as measurements become combined.

36 MATERIALS SCIENCE↗