Search NASA⌕ Search

SEARCH · Search NASA

Results for “current operating point”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Network-Level Optimization for Unbalanced Power Distribution System: Approximation and Relaxation

The nonlinear programming (NLP) problem to solve distribution-level optimal power flow (D-OPF) poses convergence issues and does not scale well for unbalanced distribution systems. The existing scalable D-OPF algorithms either use approximations that are not valid for an unbalanced power distribution system, or apply relaxation techniques to the nonlinear power flow equations that do not guarantee a feasible power flow solution. In this paper, we propose scalable D-OPF algorithms that simultaneously achieve optimal and feasible solutions by solving multiple iterations of approximate, or relaxed, D-OPF subproblems of low complexity. The first algorithm is based on a successive linear approximation of the nonlinear power flow equations around the current operating point, where the D-OPF solution is obtained by solving multiple iterations of a linear programming (LP) problem. The second algorithm is based on the relaxation of the nonlinear power flow equations as conic constraints together with directional constraints, which achieves optimal and feasible solutions over multiple iterations of a second-order cone programming (SOCP) problem. Finally, it is demonstrated that the proposed algorithms are able to reach an optimal and feasible solution while significantly reducing the computation time as compared to an equivalent NLPD-OPF model for the same distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 11.2: Inverters, Power Optimizers, and Microinverters

Inverters span a wide range of sizes, topologies, and connection voltages: from utility-scale megawatt inverters to string inverters. Switch-mode power conversion relies on high frequency chopping of DC signal to periodically charge and discharge energy storage elements, such as inductors and capacitors. Additional circuit components are required to address practical issues in inverters such as voltage ripple and harmonic distortion. Inverters are beginning to incorporate components with a bandgap above should be 3 eV, such as SiC and GaN. Photovoltaic (PV) modules respond dynamically to changing temperature and irradiation conditions. Thus, maximum DC power extraction requires periodic adjustment of the PV voltage and current operating point. An inverter's total efficiency is measured by the product of its conversion efficiency and the maximum-power-point tracking (MPPT) efficiency. This chapter lists the primary functions of inverters that include auxiliary capabilities, such as monitoring of DC and AC performance, and other error reporting.

14 SOLAR ENERGY↗

Predictive Dynamic Security Assessment through Advanced Computing

Abstract— Traditional dynamic security assessment is limited by several factors and thus falls short in providing real-time information to be predictive for power system operation. These factors include the steady-state assumption of current operating points, static transfer limits, and low computational speed. This addresses these factors and frames predictive dynamic security assessment. The primary objective of predictive dynamic security assessment is to enhance the functionality and computational process of dynamic security assessment through the use of high-speed phasor measurements and the application of advanced computing technologies for faster-than-real-time simulation. This paper presents algorithms, computing platforms, and simulation frameworks that constitute the predictive dynamic security assessment capability. Examples of phasor application and fast computation for dynamic security assessment are included to demonstrate the feasibility and speed enhancement for real-time applications.

advanced, computing, security, assessment, predict↗

Path planning during combustion mode switch

Systems and methods are provided for transitioning between a first combustion mode and a second combustion mode in an internal combustion engine. A current operating point of the engine is identified and a target operating point for the internal combustion engine in the second combustion mode is also determined. A predefined optimized transition operating point is selected from memory. While operating in the first combustion mode, one or more engine actuator settings are adjusted to cause the operating point of the internal combustion engine to approach the selected optimized transition operating point. When the engine is operating at the selected optimized transition operating point, the combustion mode is switched from the first combustion mode to the second combustion mode. While operating in the second combustion mode, one or more engine actuator settings are adjusted to cause the operating point of the internal combustion to approach the target operating point.

42 ENGINEERING↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Life Cycle Assessment of the MBT plant in Ano Liossia, Athens, Greece

Highlights: Black-Right-Pointing-Pointer We model the operation of an MBT plant in Greece based on LCA. Black-Right-Pointing-Pointer We compare four different MBT operating scenarios (among them and with landfilling). Black-Right-Pointing-Pointer Even the current operation of the MBT plant is preferable to landfilling. Black-Right-Pointing-Pointer Utilization of the MBT compost and metals generates the most environmental gains. Black-Right-Pointing-Pointer Thermal exploitation of RDF improves further the environmental performance of the plant. - Abstract: The aim of this paper is the application of Life Cycle Assessment to the operation of the MBT facility of Ano Liossia in the region of Attica in Greece. The region of Attica is home to almost half the population of Greece and the management of its waste is a major issue. In order to explicitly analyze the operation of the MBT plant, five scenarios were generated. Actual operation data of the MBT plant for the year 2008 were provided by the region of Attica and the LCA modeling was performed via the SimaPro 5.1 software while impact assessment was performed utilizing the Eco-indicator'99 method. The results of our analysis indicate that even the current operation of the MBT plant is preferable to landfilling. Among the scenarios of MBT operation, the one with complete utilization of the MBT outputs, i.e. compost, RDF, ferrous and non-ferrous metals, is the one that generates the most environmental gains. Our analysis indicates that the exploitation of RDF via incineration is the key factor towards improving the environmental performance of the MBT plant. Our findings provide a quantitative understanding of the MBT plant. Interpretation of results showed that proper operation of the modern waste management systems can lead to substantial reduction of environmental impacts and savings of resources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressure-independent point in current-voltage characteristics of coplanar electrode microplasma devices operated in neon

We introduce the idea of a pressure-independent point (PIP) in a group of current-voltage curves for the coplanar electrode microplasma device (CEMPD) at neon pressures ranging from 15 to 95 kPa. We studied four samples of CEMPDs with different sizes of the microcavity and observed the PIP phenomenon for each sample. The PIP voltage depends on the area of the microcavity and is independent of the height of the microcavity. The PIP discharge current, I{sub PIP}, is proportional to the volume (Vol) of the microcavity and can be expressed by the formula I{sub PIP}=I{sub PIP0}+DxVol. For our samples, I{sub PIP0} (the discharge current when Vol is zero) is about zero and D (discharge current density) is about 3.95 mA mm{sup -3}. The error in D is 0.411 mA mm{sup -3} (less than 11% of D). When the CEMPD operates at V{sub PIP}, the discharge current is quite stable under different neon pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global symmetry and integral constraint on superconformal lines in four dimensions

We study properties of point-like impurities preserving flavor symmetry and supersymmetry in four-dimensional 𝒩 = 2 field theories. At large distances, such impurities are described by half-BPS superconformal line defects. By working in the AdS 2 × S 2 conformal frame, we develop a novel and simpler way of deriving the superconformal Ward identities relating the various two-point functions of flavor current multiplet operators in the presence of the defect. We use these relations to simplify a certain integrated two-point function of flavor current multiplet operators that, in Lagrangian theories, can be computed using supersymmetric localization. The simplification gives an integral constraint on the two-point function of the flavor current multiplet superconformal primary with trivial integration measure in the AdS 2 × S 2 conformal frame. We provide several consistency checks on our Ward identities.

extended supersymmetry↗

Approximation of the maximum frequency of operation for point‐contact MIM diodes from DC current against voltage measurements

Point‐contact metal–insulator–metal (MIM) diodes have been used for detection and mixing at frequencies as high as 520 THz. In detection, the current responsivity (CR), defined as the change in the DC current caused by an incremental change in the high‐frequency input power, depends on the dimensions of the diode and the test fixture. However, other researchers have shown that the intrinsic current responsivity (ICR) which sets an upper bound for the CR may be determined from DC current against voltage measurements. Additional calculations from DC measurements have been used to determine an upper bound for the maximum frequency of operation.

Snyder, G.↗

Postfault Operation of Three-Level Inverter Driven Six-Phase PMSM With Enhanced Torque–Speed Region

This article presents an open-switch postfault operational technique with enhanced torque–speed region for three-level (3L) active neutral point clamped (ANPC) inverter-driven symmetrical six-phase (SSP) permanent magnet synchronous machines (PMSMs). Maximum torque (MT), minimum loss (ML), and single three-phase (STP) operations are commonly used for the postfault operations of six-phase drives. The maximum possible torque and speed in these operations are generally limited by voltage, current ratings, and the neutral point configuration of the motor. To enhance the postfault torque and speed operating region, the torque and speed limits in different postfault operational techniques are determined based on the voltage, current constraints, and neutral point configuration of the SSP-PMSM. In this work, a unified postfault operation is proposed that increases the postfault operational limits by combining MT, ML, and STP operations and modifying the neutral point configuration of the SSP-PMSM. In addition, a technique is also presented that modifies the pulsewidth modulation technique to enable full torque operation below 0.5 p.u. speed. The proposed postfault operational technique enables full-speed (1 p.u.) operation by operating in STP mode and full torque operation (1 p.u.) below 0.5 p.u. speed. Furthermore, the postfault operational technique is experimentally validated using a Gallium Nitride (GaN) device-based3L-ANPC inverter-driven SSP-PMSM.

42 ENGINEERING↗

Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment

Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analytical model for vertical dual-cavity quantum-dot optical amplifiers

Novel closed-form model for the threshold conditions and the optical gains of vertical dual-cavity semiconductor optical amplifier (VDC-SOA) is derived. Expressions for the transfer functions that relate the average photon density inside the two cavities to the incident photon density are derived. The model is simple, accurate and easy to use for designing dual-wavelength laser amplifiers. Good agreement is obtained between the analytical model and numerical calculations. The transmitted and reflective bistability characteristics of quantum dot VDC-SOA have been investigated. The threshold condition of each mode is expressed in terms of the top-cavity and the bottom-cavity currents. The dual modes λ{sub o}{sup +} and λ{sub o}{sup −} show different bistability behavior as a function of the top cavity current when the device operates at fixed operating point below the threshold curve. We find that the contrast ratio of mode λ{sub o}{sup +} is a weak function of the device currents, and the hysteresis width increases when the top cavity current is increased. For mode λ{sub o}{sup −} large contrast ratio and hysteresis width are obtained when the two cavities exhibit equal currents. Our analysis also reveals that the spectral characteristics of mode λ{sub o}{sup +} are different from that of mode λ{sub o}{sup −}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subgap biasing of superconducting tunnel junctions without a magnetic field

Superconducting tunnel junctions (STJs) have been successfully used as single-photon detectors but require the use of a magnetic field to operate. A recent paper has proposed the idea to use a circuit of three junctions in place of a single junction in order to achieve the necessary biasing without applying a magnetic field. The nonlinear interaction between the different junctions in the circuit causes the existence of a stable subgap state for one of the junctions, which acts as the detector junction. In this paper, we present the first measurements demonstrating the existence of such a biasing state feasible for STJ detectors. Single junction measurements with an applied magnetic field help determine the functional form of the subgap current versus voltage; then the operating point of a three-junction circuit is measured and fit to theory. The excellent match between theory and experiment demonstrates the existence of the subgap biasing state. The outlook for possible use in detector applications is discussed.

36 MATERIALS SCIENCE↗

Frequency Response Analysis to Monitor and Identify Changes in the Impedance of a Photovoltaic Panel Measured Online using a Power Optimizer

Photovoltaic (PV) cells are generally modeled as a current source due to photocurrent, p-n junction diodes with parasitic resistance, capacitance, and inductance. This paper proposes online frequency response analysis (FRA) to measure the impedance of a PV panel using an existing panel-level power optimizer in a PV system. The algorithm will actively perturb a small signal into a 300 W rooftop PV panel and compute its small signal impedance. The technology discussed is easy to incorporate, requires no additional hardware, doesn't alter the stability of the system, and is implemented at a steady-state point. The power optimizer initially stabilizes at an operating point and then perturbs the PV current via FRA and computes PV panel impedance. The relative standard deviation test conducted indoors under 300 W/m 2 illumination on a PV panel shows a less than 5% error rate in PV panel impedance magnitude and phase is measured using a power optimizer.

14 SOLAR ENERGY↗

US LHCNet: Transatlantic Networking for the LHC and the U.S. HEP Community

US LHCNet provides the transatlantic connectivity between the Tier1 computing facilities at the Fermilab and Brookhaven National Labs and the Tier0 and Tier1 facilities at CERN, as well as Tier1s elsewhere in Europe and Asia. Together with ESnet, Internet2, and other R&E Networks participating in the LHCONE initiative, US LHCNet also supports transatlantic connections between the Tier2 centers (where most of the data analysis is taking place) and the Tier1s as needed. Given the key roles of the US and European Tier1 centers as well as Tier2 centers on both continents, the largest data flows are across the Atlantic, where US LHCNet has the major role. US LHCNet manages and operates the transatlantic network infrastructure including four Points of Presence (PoPs) and currently six transatlantic OC-192 (10Gbps) leased links. Operating at the optical layer, the network provides a highly resilient fabric for data movement, with a target service availability level in excess of 99.95%. This level of resilience and seamless operation is achieved through careful design including path diversity on both submarine and terrestrial segments, use of carrier-grade equipment with built-in high-availability and redundancy features, deployment of robust failover mechanisms based on SONET protection schemes, as well as the design of facility-diverse paths between the LHC computing sites. The US LHCNet network provides services at Layer 1(optical), Layer 2 (Ethernet) and Layer 3 (IPv4 and IPv6). The flexible design of the network, including modular equipment, a talented and agile team, and flexible circuit lease management, allows US LHCNet to react quickly to changing requirements form the LHC community. Network capacity is provisioned just-in-time to meet the needs, as demonstrated in the past years during the changing LHC start-up plans.

97 MATHEMATICS AND COMPUTING↗

Scalar mesons within QCD sum rules in the planar limit

The spectra of masses and decay constants for non-strange scalar mesons in the energy range 0-2.5 GeV is analyzed. It is known from meson phenomenology that for given quantum numbers these spectra approximately follow linear trajectories with a universal slope. These facts can be understood in terms of an effective string description for QCD. For light meson states the trajectories deviate noticeably from the linear behavior. We investigate the possible corrections to the linear trajectories by matching two-point correlators of quark currents to the Operator Product Expansion (OPE). We find that the allowed modifications to the linear Regge behavior must decrease rapidly with the principal quantum number. After fitting the lightest states in each channel and certain low-energy constants the whole spectrum for scalar meson masses and residues is obtained in a satisfactory agreement with phenomenology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗