Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY↗

High tensile alloy of copper to mitigate current collector deformation in silicon electrodes for lithium-ion batteries

The volumetric changes of silicon electrodes, along with the strong adhesive properties of certain binders, can lead to plastic deformation of the current collector and create damage in the electrode coating. Here, in this study, we report a detailed study of silicon coatings on a high-tensile alloy (HTA) foil of copper with strength over twice that of conventional copper foils. The HTA current collectors with high mechanical strength can mitigate plastic deformation upon continuous cycling. At moderate areal capacities (2.5–3 mAh cm −2 ), conventional copper foils show significant wrinkling after only a few electrochemical cycles, whereas the HTA foils remain intact. We demonstrate viability of the HTA foils in large format xx6395 pouch cells, in which the HTA current collectors remain intact even at an areal capacity of 4.5 mAh cm −2 ; in contrast, wrinkles form in conventional copper current collectors increasing the likelihood of lithium plating. Computational studies show that stresses generated during cycling of silicon electrodes are very high in the current collector and at the current collector-coating interface, explaining the wrinkling of conventional Cu foils. Our studies highlight importance of current collector to solve the electrochemical and chemo-mechanical performance challenges associated with high-loading silicon electrodes.

Chemo-mechanical degradation↗

Kinetics Measurements in Resistive Electrolytes Using Ring-Disk Electrode: Ring as Current “Shield” Enables Uniform Disk Current Distribution

Rotating disk electrodes are commonly used for electrochemical kinetics measurements. A major disadvantage of these types of electrodes is their nonuniform secondary current distribution, especially when performing electroanalytical measurements in resistive electrolytes. Such nonuniform current distribution can render the values of kinetics constants extracted from the disk electrode to be highly inaccurate. Furthermore, one emerging class of electrolytes that suffer from low ionic conductivities is deep eutectic solvents (DES). DES are a promising class of electrolytes for various emerging applications; however, due to their resistive nature, the secondary current distribution when using them is typically highly nonuniform. For example, the Wagner number when measuring Cu²⁺/Cu⁺ kinetics in choline chloride–ethylene glycol DES (1:4 molar ratio of ChCl:EG) is very low (<0.1), indicating highly nonuniform current distribution over the disk electrode. We show here that the Cu²⁺/Cu⁺ exchange current density measured using disk electrodes is very inaccurate due to the aforementioned nonuniform current distribution. To obtain uniform disk current distribution, we employ here a coplanar concentric rotating ring-disk electrode (RRDE), where the ring serves the function of a current “shield.” Specifically, we show using modeling that the ring minimizes the current distribution nonuniformity at the disk by effectively shielding the disk against current spikes near the disk edge. This enables improved precision in electrode kinetics measurements for the Cu²⁺/Cu⁺ couple in resistive DES. To enable broad applicability of this technique, an analytical expression based on the Wagner number is integrated into an iterative algorithm to help users identify ring conditions to achieve uniform current distribution and thus improved electroanalytics at the disk.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uniform secondary current distribution at disk electrodes under Tafel kinetics enabled by concentric current-shielding rings

Non-uniform secondary current distribution at rotating disk electrodes (RDE) is a common problem when using resistive electrolyte media or large applied currents. In a recent publication, we have shown that auxiliary electrodes such as the ring of a rotating ring disk electrode (RRDE) can help suppress current non-uniformities at the disk enabling reliable electroanalytical measurements. However, this previous work considered linear kinetics where current distribution non-uniformities were moderate. In the present contribution, we consider current distribution non-uniformities encountered under Tafel kinetics. We show, for the case of 2,5-dihydroxy-1,4-benzoquinone (DHBQ) reduction, that optimally chosen ring conditions serve to provide effective shielding at the disk edge rendering the overall disk current distribution to be uniform. Numerical modeling and scaling analysis (using the Wagner number) are presented to aid a user in determining the optimal ring current density for achieving uniform disk current distribution under Tafel kinetics. This approach is especially useful when studying soluble-soluble redox transitions for which, unlike deposit distribution in electrodeposition, the current distribution non-uniformity is not visually apparent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Current ramp-up studies for NSTX-U in support of the development of non-inductive current ramp-up scenarios in STs

The Spherical Tokamak (ST) is a low-aspect-ratio tokamak projected to enable simultaneous operation at high normalized toroidal beta and high bootstrap current fraction. However, a compact ST reactor cannot be built with a full-sized solenoid. The remaining current required for sustained operation must be ramped up non-inductively. Sustained 100% non-inductive current drive at the MA level has not yet been demonstrated on an ST. Non-inductive current ramp-up is therefore a more challenging objective that the NSTX-U research program aims to address. In support of this development, free-boundary TRANSP simulations have been used to develop a current ramp-up scenario in which a significant fraction of the current is driven non-inductively by a combination of neutral-beam and bootstrap current drive. The resulting discharge has properties favorable for non-inductive current drive, such as a low normalized internal plasma inductance of approximately 0.45, a minimum safety factor exceeding 2, and a slightly reversed-shear q-profile. In these discharges, the plasma current ramps to 900 kA within 250 ms in an L-mode configuration, with varying electron density and density profiles. These discharges should be suitable for next-step NSTX-U experiments aimed at generating a robust L-mode fiducial scenario with low central solenoid flux consumption, which could be progressively improved as new NSTX-U experimental discharges are developed.

Raman, Roger [Univ. of Washington, Seattle, WA (Un↗

Staying Current: A Community Readiness Framework for Marine Energy Applied to River Current Energy in Alaska

Marine energy-including wave, tidal, and river current energy-can provide a local energy source for rural and remote communities. Marine energy has the potential to bolster self-sufficiency and create economic opportunities while preserving ecological integrity. Communities may be interested in deploying, testing, and advancing these early-stage technologies to meet their needs. However, limited capacity, workforce constraints, and other barriers can challenge development. To better understand a community's interest in and preparedness for marine energy, we developed a suite of 150 'metrics of readiness.' Organized across seven categories-technical, social, environmental, strategic, governance, economic, financial-and 29 subcategories, the metrics provide a holistic perspective beyond the technical aspects of an energy device. We conducted a desktop application of the metrics of readiness for Igiugig, Alaska. The metrics were applied retrospectively for two points in time: before (2009) and after (2018) in-stream testing of a river current energy device. By documenting changes among categories and subcategories of the metrics, our results show the evolving nature of community readiness for river current energy. They also illustrate how our interdisciplinary framework captures the investment in environmental effects research and commitment to strategic planning that occurred in Igiugig. In future applications, we envision the framework could be used to foster public engagement in marine energy, collaborate with communities in project development, shape capacity building activities, prioritize investments, and inform research needs. While our study focuses on enabling river current energy in Alaska, the metrics of readiness have the potential to inform implementation of other renewable technologies with communities in new geographies.

13 HYDRO ENERGY↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗

Optical analysis of III-nitride micro-light-emitting diodes with different sidewall treatments at low current density operation

Here, in this work, the optical efficiency of III-nitride blue micro-LEDs (μLEDs) ranged from 5 × 5 to 60 × 60 μm 2 with different sidewall treatments at low current density range was investigated. The results showed dielectric sidewall passivation using atomic layer deposition (ALD) has superior optical enhancement compared to conventional RF sputtering, where most of the enhancement occurred at low current density range. Additionally, the use of ALD sidewall passivation and chemical treatment offered significant efficiency improvement for different sizes of μLEDs at operating less than 1 A cm −2 and the devices without sidewall treatments did not emit light. The effect of sidewall treatments to the effective Shockley–Read–Hall (SRH) nonradiative recombination coefficient, or the effective A coefficient from the ABC model, was estimated. The effective SRH nonradiative recombination coefficient was suppressed by two orders of magnitude for devices with sidewall treatments compared to devices without sidewall passivation.

Wong, Matthew S.↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Study on Conversion from an Existing Alternating Current Medium-Voltage Line to a Direct Current Line: A Case of Load or Source Expansion

Simultaneous increase of power generation through renewable systems and load due owing to the rapid growth in electrified road transportation systems, leads to new challenges in the design, operation, and protection of distribution-level electrical power systems. This paper addresses challenges related to the integration of new sources or loads to a distribution grid through long alternating current lines. The International Council on Large Electric Systems medium-voltage benchmark model developed for North America was used for simulation studies. Use cases were developed to illuminate the issues related to long alternating current lines and the usefulness of medium-voltage direct current lines in a distribution network.

Jaldanki, Sreenivasa↗

A Scalable Test-Bed for Direct Current Current Transformer Automated Functional Testing and Characterization

This article describes a scalable test-bed for automation of measurements of the direct current current transformers (DCCT). Automation of measurement involves functional measurements, fault event based measurements and data validation. The test-bed is designed to measure up to 20 DCCTs at a time with software based measurement repetition checks and validation of the measurements.

43 PARTICLE ACCELERATORS↗

Carbon Outgassing in the Antarctic Circumpolar Current Is Supported by Ekman Transport From the Sea Ice Zone in an Observation‐Based Seasonal Mixed‐Layer Budget

Despite its importance for the global cycling of carbon, there are still large gaps in our understanding of the processes driving annual and seasonal carbon fluxes in the high-latitude Southern Ocean. This is due in part to a historical paucity of observations in this remote, turbulent, and seasonally ice-covered region. Here, we use autonomous biogeochemical float data spanning 6 full seasonal cycles and with circumpolar coverage of the Southern Ocean, complemented by atmospheric reanalysis, to construct a monthly climatology of the mixed layer budget of dissolved inorganic carbon (DIC). We investigate the processes that determine the annual mean and seasonal cycle of DIC fluxes in two different zones of the Southern Ocean—the Sea Ice Zone (SIZ) and Antarctic Southern Zone (ASZ). We find that, annually, mixing with carbon-rich waters at the base of the mixed layer supplies DIC which is, in the ASZ, either used for net biological production or outgassed to the atmosphere. In contrast, in the SIZ, where carbon outgassing and the biological pump are weaker, the surplus of DIC is instead advected northward to the ASZ. In other words, carbon outgassing in the southern Antarctic Circumpolar Current (ACC), which has been attributed to remineralized carbon from deep water upwelled in the ACC, is also due to the wind-driven transport of DIC from the SIZ. These results stem from the first observation-based carbon budget of the circumpolar Southern Ocean and thus provide a useful benchmark to evaluate climate models, which have significant biases in this region.

Sauvé, Jade↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Differential Charged Current 𝝂_𝝁− Argon Cross Section without Pions in the Final State Measurement in MicroBooNE , and Current Status of Simultaneous Cross Section Extraction with ANNIE

MicroBooNE, an 85-tonne liquid argon time projection chamber detector is on-axis to the Booster Neutrino Beam (BNB) at Fermi National Accelerator Laboratory. MicroBooNE is elucidating neutrino interactions with argon through cross-section measurements to refine interaction models and reduce uncertainties. In this poster, we present recent published single and double multi-differential charged current (CC) cross section with zero pions in the final state (CC-0 ) as a function of muon momentum ( ) and the cosine of the muon angle ( ). We present the details of the event selection and the extraction of 1D and 2D cross sections. We further report on the status of a simultaneous cross-section extraction conducted in conjunction with the ANNIE experiment, which employs a Gd-H O target and operates on the same BNB beamline. This joint measurement enables a precision test of nuclear A-dependence between oxygen and argon, with shared flux and cross-section model correlations leading to the cancellation of systematic uncertainties.

Nguyen, Christian Van [Rutgers U., Piscataway] (OR↗