Search NASA⌕ Search

SEARCH · Search NASA

Results for “custom designed systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Software Defined Architectures for Portability and Performance

The Software Defined Architectures for Portability and Performance (SODAPOP) project developed a co-design framework to partition and map converged applications on specialized heterogeneous architectures. We started from key domain applications that combine scientific simulation with data analytics and machine learning as drivers to integrate our framework. The framework includes high-level compilers that interfaces with high-level programming frameworks, domain-specific optimization passes, and hardware-oriented optimizations. The framework leverages hardware generators to enable specialization and facilitate exploration of custom system designs.

97 MATHEMATICS AND COMPUTING↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Systems Innovation: Modernization & Efficiencies for ESH&Q Reviews

Environmental compliance reviews at INL have traditionally been managed through fragmented systems, relying on multiple spreadsheets and manual processes. This inefficiency led to time-consuming status updates and redundant tasks, such as manually sending reminder emails and transferring data from Excel to the Environmental Review Process (ERP). Initial attempts to streamline these processes using Power Automate and Excel revealed significant limitations, necessitating a more comprehensive solution. To address these immediate inefficiencies, automated workflows were developed using Power Automate. These workflows were designed to send scheduled status update reminders and capture responses through standardized forms, with submitted data flowing directly into centralized Excel trackers. This automation reduced the administrative burden, improved data accuracy, and enabled faster, more consistent reporting. Specifically, email automation achieved a 65% efficiency gain, while data integration saw a 48% improvement, resulting in 91% of project statuses being updated within two months. Despite the improvements brought by Power Automate, the fragmented nature of the review processes persisted. To further enhance efficiency and accuracy, the Integrated Review Tool (IRT) was developed. The IRT aims to centralize review initiation and connect team systems, creating an interconnected data infrastructure that preserves team autonomy while enhancing overall efficiency. This tool automates email reminders, centralizes reviews, and streamlines data integration, significantly improving the accuracy and efficiency of environmental compliance reviews. The design and development of the IRT involved advanced systems methodology, process mapping, project management, and collaboration with subject matter experts. The minimum viable product design is 100% complete, and system development is currently underway, with expected outcomes including a centralized entry point for all ESH&Q reviews, automated routing, real-time tracking and analytics, AI integration, and a user-friendly interface. This project demonstrates the potential of leveraging automation and integrated systems to enhance efficiency, accuracy, and decision-making in environmental reporting and compliance processes at INL.

99 - GENERAL AND MISCELLANEOUS↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Feedstock and Catalyst Impact on Bio-Oil Production and FCC Co-Processing to Fuels

NREL's thermochemical biomass conversion research is focused on ex-situ upgrading of biomass fast-pyrolysis (FP) vapors as an efficient route to completely biogenic pyrolysis-based fuel precursors, fuels, and value-added chemicals depending on catalyst and process conditions. A near term pathway being developed uses these liquids for co-processing with petroleum feedstocks to assess biogenic carbon incorporation in hydrocarbon fuel feedstocks for potential refinery use. In this work, the impact of feedstock and catalyst on catalytic fast pyrolysis oil (CFPO) composition was determined with the oils then assessed for biogenic fuel production via FCC (fluidized catalytic cracking) co-processing. Biomass vapors were generated via fast pyrolysis with destabilizing vapor components (char, inorganics, tar aerosols) removed by hot gas filtration to produce clean vapors more responsive to catalytic upgrading. A Davison Circulating Riser (DCR), a petroleum industry standard for fluidized catalytic cracking (FCC) catalyst evaluation, was coupled to a custom pyrolyzer system designed to produce consistent-composition pyrolysis vapors as feed to the DCR. Pyrolysis vapors, derived from pure hardwood and softwood, were upgraded using commercially available modified zeolite-based catalysts to produce CFPOs. These upgraded oils were analyzed via 31P and 13C NMR spectroscopy, GCxGC-TOF/MS, carbonyl and ultimate analysis (CHNO), and simulated distillation (SIMDIS) to assess both oil chemistry and distillation behavior as they relate to catalyst and feedstock type for producing fungible hydrocarbon product liquids. These exploratory vapor-phase-upgrading results demonstrated the feasibility of producing refinery-compatible hydrocarbon fuel intermediates entirely from biomass-derived fast-pyrolysis vapors using an industry-accepted DCR system for catalytic upgrading. The FCC co-processing results demonstrated the feasibility of using CFPOs with VGO feeds in FCC refinery operations to produce biogenic carbon containing fuels.

biogenic carbon↗

Feedstock and Catalyst Impact on Bio-Oil Production and FCC Co-Processing to Fuels

NREL’s thermochemical biomass conversion research is focused on ex-situ upgrading of biomass fast-pyrolysis (FP) vapors as an efficient and economical route to completely biogenic pyrolysis-based fuel precursors, potential fuels, and value-added chemicals depending on catalyst choice and process conditions. In this approach, biomass vapors are generated via fast pyrolysis with destabilizing vapor components (char, inorganics, tar aerosols) removed by hot gas filtration to produce conditioned vapors more responsive to catalytic upgrading. A Davison Circulating Riser (DCR), a petroleum industry standard for fluidized catalytic cracking (FCC) catalyst evaluation, was coupled with a custom pyrolyzer system designed to produce consistent composition pyrolysis vapors as feed to the DCR. The coupled system is shown below (Figure 1). Pyrolysis vapors, derived from pure hardwood and softwood, were upgraded using commercially available and laboratory modified zeolite-based catalysts. Upgraded oils were analyzed via 31P and 13C NMR spectroscopy, GCxGC-TOF/MS, carbonyl and ultimate analysis (CHNO), and micro distillation to assess both oil chemistry and distillation behavior as they relate to catalyst and feedstock type for producing fungible hydrocarbon product liquids. Measured process parameters identified from technoeconomic process analysis included achieving oil oxygenate contents of 20% or less, carbon-conversion efficiencies of 30% or more, and catalyst coking rates of 10% or less. A proprietary modified zeolite catalyst from Johnson Matthey produced oils that met these requirements. Using the DCR equipped with a proprietary nozzle system, a second approach focused on reducing the carbon intensity of petroleum-derived hydrocarbon fuels by FCC co-processing these CFP oils with petroleum vacuum gas oil (VGO) to produce biogenic carbon containing fuels. The vapor-phase upgrading results demonstrated for the first time the feasibility of producing refinery-compatible hydrocarbon fuel intermediates entirely from biomass-derived fast-pyrolysis vapors using an industry-accepted DCR system for catalytic upgrading. The co-processing results demonstrated the feasibility of using CFP oils with VGO feeds in FCC refinery operations to produce biogenic carbon containing fuels.

bio-oil↗

Modular, Mobile Systems for the Treatment of Contaminated Water at Three Magnox Sites in the United Kingdom - 20421

Veolia Nuclear Solutions (VNS), and its mitigated entity, Veolia Nuclear Solutions Federal Services (VNSFS), are designing, overseeing the fabrication and installation, and supporting the commissioning of highly mobile and modular skid-based water treatment systems to assist in the decommissioning of three Magnox reactor sites based in the U.K. These Modular Active Effluent Treatment Plants (MAETP) will be deployed at the Chapelcross, Hinkley Point A, and Dungeness A sites to process contaminated water through the use of ion exchange systems and/or filtration units. At the time of writing, two systems have been installed and inactively commissioned, and the third system is expected to be delivered in 2020. Veolia has utilized a multi-national team of engineers, based in the UK and the US, to effectively leverage the best of Veolia expertise in the design and delivery of mobile, modular systems. The VNS team continues to refine the modular, mobile, and scalable approach to water processing system delivery, and has successfully patented the evolving technology for proprietary protection. The intent of this technology investment is to improve the functionality, mobility, and modularity, resulting in a system which can be adapted to a broad range of throughput and isotope removal requirements to achieve the most cost effective, flexible system possible for customers. Designing, fabricating, and factory-testing the modules off site followed by onsite installation, testing, start-up, and commissioning ensures expedited delivery and setup, as well as cost savings for nuclear applications. For the MAETP systems, VNS's previous nuclear site experience and ongoing Research and Development (R and D), combined with the resulting mobile/modular water processing systems developed and successfully deployed by VNS, have proven to be important inputs for the successful end-design of the systems, materials selection, system testing and commissioning. The lessons learned in the development and continued enhancement of the patented systems described in this paper will prove useful in advancing and deploying future systems for other nuclear sites, where rapid customizing and cost-effective implementation are critical factors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blockchain for Fault-Tolerant Grid Operations

Distribution system fault/failure has a direct impact on customers. Distribution systems are not designed with the contingency of one or more elements failing as the transmission system, however, distribution systems are more likely to have faults in comparison to transmission and generation systems. Most of the distribution systems have a radial design with the protection system assumption of unidirectional power flow. The radial design results in the disconnection of customers for any given component failure. The rapid deployment of distributed energy resources conflicts with the assumption of unidirectional power flow. To maintain/improve the distribution system fault tolerance for a grid with high penetration of distributed energy resources requires improvement. Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain’s core features of distributed consensus-based decision-making process and immutability. In the process of preparing for an event or system restoration, there is a need for reliable data and system situational awareness. The system situational awareness enables accurate planning for possible scenarios and system restoration after an event, an area where blockchain’s distributed architecture can help. The value of blockchain for a fault-tolerant grid operation is elaborated with three use cases: 1) fault location, isolation, and service restoration; 2) topology identification; and 3) data configuration. These use cases demonstrate how blockchain-based architecture can facilitate bridging the vulnerabilities of the existing implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An automated multiplexed turbidometric and data collection system for measuring growth kinetics of anaerobes dependent on gaseous substrates

Standard methods of monitoring the growth kinetics of anaerobic microorganisms are generally impractical when there is a protracted or indeterminate period of active growth, and when high numbers of samples or replications are required. As part of our studies of the adaptive evolution of a simple anaerobic syntrophic mutualism, requiring the characterization of many isolates and alternative syntrophic pairings, here we developed a multiplexed growth monitoring system using a combination of commercially available electronics and custom designed circuitry and materials. This system automatically monitors up to 64 sealed, and as needed pressurized, culture tubes and reports the growth data in real-time through integration with a customized relational database. The utility of this system was demonstrated by resolving minor differences in growth kinetics associated with the adaptive evolution of a simple microbial community comprised of a sulfate reducing bacterium, Desulfovibrio vulgaris, grown in syntrophic association with Methanococcus maripaludis, a hydrogenotrophic methanogen.

59 BASIC BIOLOGICAL SCIENCES↗

Design of a custom vapor transport co-deposition system for scalable production of perovskite solar cells

Vacuum-deposited perovskites provide a more direct path to manufacturing large area solar cells because of ready compatibility with multilayered architectures and historic use in the electronics industry. However, vacuum compatible co-deposition of organic-inorganic perovskites remains difficult due to issues of precisely controlling the organic precursor flux. Here, we demonstrate a manufacturing prototype specifically designed for co-depositing organic-inorganic perovskites and evaluate it with respect to the influence of process parameters on film growth. Through depositing and characterizing methylammonium lead iodide (MAPbI3) perovskite films, we highlight the necessary design requirements while measuring the influence of film growth parameters on deposition rate and perovskite phases.

14 SOLAR ENERGY↗

Hydrogen Recombiner Catalyst Evaluations for Waste Storage

Radiolysis of water in nuclear waste storage generates hydrogen gas that can accumulate within sludge style waste and be rapidly released during agitation events, creating a significant flammability hazard. Engineering controls are therefore required to limit hydrogen concentrations during both quiescent storage and transient disturbances. Catalytic recombination of hydrogen in waste storage offgas is a proven mitigation strategy, maintaining hydrogen levels below flammability limits and managing sudden concentration spikes. Conventional recombiners rely on platinum and/or palladium catalysts, with development efforts focused on extending service life, increasing active surface area, and ensuring safe deployment in radioactive environments. Savannah River National Laboratory (SRNL) is evaluating a newly developed hydrogen recombiner catalyst from Canadian Nuclear Laboratories as a cost-effective and durable alternative for nuclear waste applications. Testing was conducted in SRNL’s Shielded Cells facility, which enables reduced-scale experimental modeling under radiation fields and near-use-case conditions relevant to radioactive waste storage. Catalyst performance was evaluated using a custom offgas characterization system designed for near-zero flow conditions. The experimental apparatus consisted of a gas-tight 2.7 L PTFE vessel equipped with temperature monitoring, gas flow controls, and a variable-speed mixer to simulate sludge agitation. Offgas composition was monitored using a dedicated gas chromatograph with argon carrier gas and a krypton internal standard. Measurements were obtained for an empty vessel, the vessel containing a well characterized radioactive tank waste sample, and the same configuration with the candidate catalyst installed. Results demonstrate that the new catalyst effectively reduced hydrogen concentrations in the offgas within the constraints of the experimental design. In addition to confirming catalytic activity, the testing provided valuable insights into experimental optimization and considerations for future performance evaluations. These findings support the potential scalability of the technology and highlight its applicability to broader nuclear waste management operations, offering improved safety and reduced operational costs through enhanced catalyst durability and lower replacement frequency.

Tener, Zachary P. [Savannah River National Laborat↗

A simple centrifuge cell method for ex situ quantification of electrical conductivity of slurry electrode materials

We present the design, experimental procedure, and experimental evaluation of a system for fast, simple, and ex situ characterization of electrical conductivity of slurry electrode materials. The system uses a custom-designed electrochemical cell compatible with centrifugation in a swing-bucket centrifuge. The cell features cylindrical graphite electrodes that are partially sheathed so as to expose only 2 mm of the electrode surface to the bottom region of the packed particulate pellet. Also presented is a conduction model that provides a shape factor for estimating effective conductivity. We tested aqueous solutions of carbon black (CB), activated carbon (AC), and mixtures thereof. These particles were dispersed in 0.0 and 0.5 M NaCl solutions. Measurements show that the effective conductivity initially increases linearly with pellet mass and then saturates at higher masses. Notably, CB exhibited a fivefold increase in conductivity than AC at equal pellet masses. CB/AC mixtures at a fixed pellet mass were tested with CB mass fractions of 0 to 100%. Interestingly, the mixture conductivity was found to be a non-monotonic function of CB mass fraction, with a maximum conductivity at about 60 % CB mass fraction. At this maximum, the mixture conductivity is approximately 30 % higher than pure CB. NaCl concentration in the slurry solution had no effects on conductivity. These results highlight the interactions between slurry electrode composition and compaction, offering insights for optimizing slurry electrodes. Furthermore, the system and results may also be applicable to evaluation of particulate materials (including slurries) used for Li-ion batteries, capacitive deionization, fuel cells, and flow electrodes.

Capacitive deionization↗

Evaluating the Impact of Residential Solar Contract Cancellations in the United States

The residential solar photovoltaic (PV) market in the United States is growing, despite frequent customer cancellations. Contract cancellations result in lost time and costs that must be borne by installers, often in the form of higher "soft costs" (i.e., non-equipment costs). These costs are often passed on to customers who successfully install PV systems. To date, few studies have attempted to estimate national cancellation rates or model the impacts on installed system costs. In this report, we utilize an installer-provided dataset of 199,665 residential PV-only projects representing about 10% of U.S. installs each year from 2017-2019. With this data, we evaluate cancellation rates and trends from contract signing to install. Next, by leveraging NREL's soft cost model for residential solar, we estimate installer spending through each phase of the pre-install process. Applying our findings on cancellation timelines and rates, we then estimate the potential cost impacts to successful installs from contract cancellations. Our work suggests that the rates and impacts of contract cancellations have been previously underestimated. Namely, we find that cancellations/unsuccessful project are; more common than previous estimates suggest; occur earlier in project timelines, though a significant number happen even after permit/ATB approvals; and contribute significantly to customer acquisition and other soft costs. We also find that cancellation do not appear to be driven by review delays in permitting and interconnection applications.

14 SOLAR ENERGY↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Launcher for Wildlife Collision Simulation on Wind Turbines to Validate Strike Detection Systems

Design and construction of a custom launcher and projectiles to simulate wildlife collisions with wind turbines is investigated. The various design features that led to success of the launcher are enumerated and described in detail. These features include custom projectiles, precision aiming capabilities, repeatable launch parameters, and azimuthal control over projectile launch. Success is investigated in terms of an overall hit percentage.

collision simulation↗

Incorporating the Role(s) of Human Actors in Complex System Design for Safety and Security

Traditional systems engineering demonstrates the importance of customer needs in scoping and defining design requirements; yet, in practice, other human stakeholders are often absent from early lifecycle phases. Human factors are often omitted in practice when evaluating and down-selecting design options due to constraints such as time, money, access to user populations, or difficulty in proving system robustness through the inclusion of human behaviors. Advances in systems engineering increasingly include non-technical influences into the design, deployment, operations, and maintenance of interacting components to achieve common performance objectives. Furthermore, such advances highlight the need to better account for the various roles of human actors to achieve desired performance outcomes in complex systems. Many of these efforts seek to infuse lessons and concepts from human factors (enhanced decision-making through Crew Resource Management), systems safety (Rasmussen's “drift toward danger”) and organization science (Giddens' recurrent human acts leading to emergent behaviors) into systems engineering to better understand how socio-technical interactions impact emergent system performance. Safety and security are examples of complex system performance outcomes that are directly impacted by varying roles of human actors. Using security performance of high consequence facilities as a representative use case, this article will outline the System Context Lenses to understand how to include various roles of human actors into systems engineering design. Several exemplar applications of this organizing lenses will be summarized and used to highlight more generalized insights for the broader systems engineering community.

42 ENGINEERING↗

Novel platinum group metal-free catalyst ink deposition system for combinatorial polymer electrolyte fuel cell performance evaluation

Here, a new system for rapid and precise fabrication of polymer electrolyte fuel cell (PEFC) membrane-electrode assemblies (MEAs) is introduced to facilitate rapid testing and characterization of platinum group metal-free (PGM-free) catalysts, with minimal waste of materials, using commercial combinatorial hardware and multi-channel potentiostat. The commercial combinatorial system, designed for high-throughput catalyst activity evaluation (i.e., low overpotential and current densities) using gas-diffusion electrodes (GDEs), has been further developed to enable simultaneous evaluation of the high current density performance on air of twenty-five cathodes prepared by coating catalyst-ionomer inks directly onto the membrane using a newly-developed deposition system. A nanopipette or micropipette coupled to a precise peristaltic pump is being used for precise and even catalyst ink deposition onto the membrane in each of twenty-five circular electrodes with areas of <1 cm 2 and in the precise locations required by the commercial combinatorial MEA hardware. The automated ink deposition system is coupled with a custom-designed heated vacuum table mounted on a computer-controlled XY stage to prevent deformation of the membrane and electrode layers during ink deposition onto the membrane. This system was utilized to evaluate the impact of ionomer to catalyst ratio on the hydrogen-air fuel cell performance of the PGM-free catalyst.

25 ENERGY STORAGE↗