Search NASA⌕ Search

SEARCH · Search NASA

Results for “custom devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an open-source electronic hardware platform, and it consists of a microcontroller and two sensors. Finally, we read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring MDSplus data-acquisition software and custom devices

MDSplus is a software tool designed for data acquisition, storage, and analysis of complex scientific experiments. Over the years, MDSplus has primarily been used for data management for fusion experiments. This paper demonstrates that MDSplus can be used for a much wider variety of systems and experiments. We present a step-by-step tutorial describing how to create a simple experiment, manage the data, and analyze it using MDSplus and Python. To this end, a custom example device was developed to be used as the data source. This device was built on an opensource electronic hardware platform, and it consists of a microcontroller and two sensors. We read data from these sensors, store it in MDSplus, and use JupyterLab to visualize and process it. This project and code demo are available on the GitHub site at this URL: https://github.com/santorofer/MDSplusAndCustomeDevices

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local Setup Errors in Image-Guided Radiotherapy for Head and Neck Cancer Patients Immobilized With a Custom-Made Device

Purpose: To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. Methods and Materials: A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. Results: The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Conclusions: Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster - 46: Intra-fraction tumor position assessment for lung SBRT in patients treated without customized immobilization devices

Purpose: To assess intra-fraction positional stability of lung cancer tumours in patients treated by kilo-voltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy (SBRT) without the use of customized immobilization devices. Material and Methods: Twenty-two patients underwent 4D-CT in the supine position with the arms in a wing board but without customized immobilization. The PTV was the internal target volume based on maximum intensity projections and a 5mm symmetric setup margin. Treatments were planned using 7–9 static fields or two volumetric modulated arcs. At treatment, the patient position was adjusted using pre-treatment CBCT. A post-treatment CBCT was taken immediately after the treatment ended. The 41 CBCT pairs were automatically matched and the transitional shifts between the two CBCTs recorded. The mean values and standard deviations were calculated for these displacements. Results and conclusions: The mean time between CBCTs (treatment time) was 16.5 ± 6 minutes (range: 10 to 34 minutes). In all cases the tumour remained inside the PTV in the post-treatment CBCT. The mean shifts between pre and post-treatment CBCTs were −0.7 ± 1.6 mm (range −5.0 to 3.0 mm) vertically, −0.3 ± 1.7 mm (range −4.8 to 3.0 mm) longitudinally, and −0.4 ± 1.5 mm (range −4.0 to 2.0 mm) laterally. Our results suggest little systematic shifting during treatment, and standard deviations that are consistent with another published report for treatments where customized immobilization was used. This result is encouraging for SBRT programs in clinics with limited resources.

60 APPLIED LIFE SCIENCES↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

Mueller, John Kyle P↗

Effects of cyclic stretch on proliferation of mesenchymal stem cells and their differentiation to smooth muscle cells

Bone marrow mesenchymal stem cells (MSCs) are capable of differentiating into a variety of cell types such as vascular smooth muscle cells (SMCs). In this study, we investigated influence of cyclic stretch on proliferation of hMSCs for different loading conditions, alignment of actin filaments, and consequent differentiation to SMCs. Isolated cells from bone marrow were exposed to cyclic stretch utilizing a customized device. Cell proliferation was examined by MTT assay, alignment of actin fibers by a designed image processing code, and cell differentiation by fluorescence staining. Results indicated promoted proliferation of hMSCs by cyclic strain, enhanced by elevated strain amplitude and number of cycles. Such loading regulated smooth muscle {alpha}-actin, and reoriented actin fibers. Cyclic stretch led to differentiation of hMSCs to SMCs without addition of growth factor. It was concluded that applying appropriate loading treatment on hMSCs could enhance proliferation capability, and produce functional SMCs for engineered tissues.

60 APPLIED LIFE SCIENCES↗

Frontiers in computing for artificial intelligence

An emerging diversity of computational platforms offers many different approaches to adopting the paradigm of artificial intelligence to the study of electron-ion collisions. Here we review several leading candidates in this computational frontier and their workflows for experimental applications of artificial intelligence that may impact the future Electron-Ion Collider. We discuss the motivation for exploring novel methods to solve artificial intelligence and machine learning problems including with customized devices, quantum simulation, and heterogeneous computing systems. Furthermore, these technologies offer promising approaches to address some of the leading concerns of future computing that may impact the Electron-Ion Collider but they will require further development and testing in order to support future planning efforts.

detector design and construction technologies and ↗

Hardware Demonstration of High-Speed Networks for Satellite Applications

This report documents the implementation results of a hardware demonstration utilizing the Serial RapidIO™ and SpaceWire protocols that was funded by Sandia National Laboratories (SNL's) Laboratory Directed Research and Development (LDRD) office. This demonstration was one of the activities in the Modeling and Design of High-Speed Networks for Satellite Applications LDRD. This effort has demonstrated the transport of application layer packets across both RapidIO and SpaceWire networks to a common downlink destination using small topologies comprised of commercial-off-the-shelf and custom devices. The RapidFET and NEX-SRIO debug and verification tools were instrumental in the successful implementation of the RapidIO hardware demonstration. The SpaceWire hardware demonstration successfully demonstrated the transfer and routing of application data packets between multiple nodes and also was able reprogram remote nodes using configuration bitfiles transmitted over the network, a key feature proposed in node-based architectures (NBAs). Although a much larger network (at least 18 to 27 nodes) would be required to fully verify the design for use in a real-world application, this demonstration has shown that both RapidIO and SpaceWire are capable of routing application packets across a network to a common downlink node, illustrating their potential use in real-world NBAs.

99 GENERAL AND MISCELLANEOUS↗

A Device and Procedure for Immobilization of Patients Receiving Limb-Preserving Radiotherapy for Soft Tissue Sarcoma

The purpose of this study was to determine the accuracy and efficiency of a custom-designed immobilization device for patients with extremity soft-tissue sarcoma. The custom device consisted of a thermoplastic shell, vacuum pillow, and adaptable baseplate. The study included patients treated from January 2005 to March 2007, with 92 patients immobilized with the custom device and 98 with an established standard. Setup times for these cohorts were analyzed retrospectively for conformal and intensity modulated radiotherapy techniques (IMRT). Thigh tumor setup times were analyzed independently. A subset of patients treated with IMRT was analyzed for setup error using the radiographically verified isocenter position measured daily with electronic portal imaging and cone-beam computed tomography. Mean setup time was reduced by 2.2 minutes when using the custom device for conformal treatment (p = 0.03) and by 5.8 min for IMRT of thigh tumors (p = 0.009). All other setup time comparisons were not significant. A significant systematic error reduction was seen in all directions using the custom device. Random error standard deviations favored the custom device. The custom device offers immobilization advantages. Patient setup time was reduced for conformal techniques and IMRT of thigh tumors. Positioning uncertainty was improved, permitting a reduction of the planning target volume margin by 2 to 4 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland–Altman analyses revealed proportional bias between prone and supine measurements (SUV{sub peak} and SUV{sub max}) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUV{sub peak} difference (P = 0.78). Conclusions: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 04: Assessment of intra-fraction motion during lung SABR VMAT using a custom abdominal compression device

Purpose: Lung SABR patients are treated using Volumetrically Modulated Arc Therapy (VMAT), utilizing 2 arcs with Conebeam CT (CBCT) image-guidance prior to each arc. Intra-fraction imaging can prolong treatment time (up to 20%), and the aim of this study is to determine if it is necessary. Methods: We utilize an in-house abdominal compression device to minimize respiratory motion, 4DCT to define the ITV, a 5 mm PTV margin and a 2–3 mm PRV margin. We treated 23 patients with VMAT, fifteen were treated to 48 Gy in 4 fractions, while eight were treated with up to 60 Gy in 8 fractions. Intrafraction motion was assessed by the translational errors recorded for the second CBCT. Results: There was no significant difference (t-test, p=0.93) in the intra-fraction motion between the patients treated with 4 and 8 fractions, or between the absolute translations in each direction (ANOVA, p=0.17). All 124 intra-fraction CBCT images were analysed and 95% remained localized within the 5 mm PTV margin The mean magnitude of the vector displacement was 1.8 mm. Conclusions: For patients localized with an abdominal compression device, the intrafraction CBCT image may not be necessary, if it is only the tumor coverage that is of concern, as the patients are typically well within the 5 mm PTV margin. On the other hand, if there is a structure with a smaller PRV margin, an intrafraction CBCT is recommended to ensure that the dose limit for the organ at risk is not exceeded.

60 APPLIED LIFE SCIENCES↗

SU-E-P-45: An Analytical Formula for Deriving Mechanical Iso-Center of Rotational Gantry Treatment Unit Rotational Gantry Treatment Unit

Purpose: To present an analytical formula for deriving mechanical isocenter (MIC) of a rotational gantry treatment unit. The input data to the formula is obtained by a custom-made device. The formula has been implemented and used in an operational proton therapy facility since 2005. Methods: The custom made device consisted of 3 mutually perpendicular dial indicators and 5 clinometers, to obtain displacement data and gantry angle data simultaneously. During measurement, a steel sphere was affixed to the patient couch, and the device was attached to the snout rotating with the gantry. The displacement data and angle data were obtained simultaneously at angular increments of less than 1 degree. The analytical formula took the displacement and angle as input and derived the positions of dial indicator tips (DIT) position in room-fixed coordinate system. The formula derivation presupposes trigonometry and 3-dimentional coordinate transformations. Due to the symmetry properties of the defining equations, the DIT position can be solved for analytically without using mathematical approximations. We define the mean of all points in the DIT trajectory as the MIC. The formula was implemented in computer code, which has been employed during acceptance test, commissioning, as well as routine QA practice in an operational proton facility since 2005. Results: It took one minute for the custom-made device to acquire the measurement data for a full gantry rotation. The DIT trajectory and MIS are instantaneously available after the measurement. The MIC Result agrees well with vendor’s Result, which came from a different measurement setup, as well as different data analysis algorithm. Conclusion: An analytical formula for deriving mechanical isocenter was developed and validated. The formula is considered to be absolutely accurate mathematically. Be analyzing measured data of radial displacements as function of gantry angle, the formula calculates the MI position in room coordinate.

60 APPLIED LIFE SCIENCES↗

Customized electric power storage device for inclusion in a microgrid

An electric power storage device included in a microgrid is described herein. The electric power storage device has at least one of a charge rate, a discharge rate, or a power retention capacity that has been customized for the microgrid. The at least one of the charge rate, the discharge rate, or the power retention capacity of the electric power storage device is computed based at least in part upon specified power source parameters in the microgrid and specified load parameters in the microgrid.

25 ENERGY STORAGE↗

Controller for a customized electric power storage device in a collective microgrid

A controller for an electric power storage device is described herein, wherein the electric power storage device is included in a microgrid. The electric power storage device has at least one of a charge rate, a discharge rate, or a power retention capacity that has been customized for a collective microgrid. The at least one of the charge rate, the discharge rate, or the power retention capacity of the electric power storage device is computed based at least in part upon specified power source parameters in the at least two connected microgrids and specified load parameters in the at least two connected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Customized electric power storage device for inclusion in a collective microgrid

An electric power storage device is described herein, wherein the electric power storage device is included in a microgrid. The electric power storage device has at least one of a charge rate, a discharge rate, or a power retention capacity that has been customized for a collective microgrid. The collective microgrid includes at least two connected microgrids. The at least one of the charge rate, the discharge rate, or the power retention capacity of the electric power storage device is computed based at least in part upon specified power source parameters in the at least two connected microgrids and specified load parameters in the at least two connected microgrids.

25 ENERGY STORAGE↗