Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hybrid Cyber-attack Detection in Photovoltaic Farms

Here, to address the cyber-physical security in PV farms, a hybrid cyber-attack detection is proposed in this manuscript. To secure PV farms, the proposed method integrates model-based and data-driven methods by fusing the detection score at the device and system levels. First, a model-based cyber-attack detection method is developed for each PV inverter. A residual between the estimation of the Kalman filter and measurement is calculated. By leveraging the calculated residual from all inverters, a squared Mahalanobis distance is developed for device detection score generation. At the system level, a convolutional neural network (CNN) is proposed to detect cyber-attack using the waveform data at the point of common coupling (PCC) in PV farms. To improve the CNN detection accuracy, a set of well-designed features are extracted from the raw waveform data. Finally, a weighted detection score fusion method is proposed to combine device and system detection scores by using their complementary strength. The feasibility and robustness of the proposed method are validated by testing cases and a comparative experiment.

14 SOLAR ENERGY↗

Systems and methods for controlling an industrial asset in the presence of a cyber-attack

Systems and methods are provided for the control of an industrial asset, such as a power generating asset. Accordingly, a cyber-attack model predicts a plurality of operational impacts on the industrial asset resulting from a plurality of potential cyber-attacks. The cyber-attack model also predicts a corresponding plurality of potential mitigation responses. In operation, a cyber-attack impacting at least one component of the industrial asset is detected via the cyber-attack neutralization module and a protected operational impact of the cyber-attack is identified based on the cyber-attack model. The cyber-attack neutralization module selects at least one mitigation response of the plurality of mitigation responses based on the predicted operational impact and an operating state of the industrial asset is altered based on the selected mitigation response.

D'Amato, Fernando Javier↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Secure State Estimation with Asynchronous Measurements for Coordinated Cyber Attack Detection in Active Distribution Systems

Coordinated cyber attacks tamper with measurement data to disrupt the situational awareness of active distribution systems. Various sensors report measurements asynchronously at different rates, which introduces challenges during state estimation. In addition, this forces cyber intruders to exert greater effort to compromise multiple communication channels and launch coordinated attacks. Therefore, multi-channel and asynchronous measurements could be harnessed to develop more secure cyber defense strategies. In this paper, a prediction-correction-based multi-rate observer is designed to exploit the value of asynchronous measurements for the detection of coordinated false data injection (FDI) attacks. First, a time-function-dependent prediction-correction strategy is proposed to adjust the sampling interval for each sensor’s measurement. Then, an observer is designed based on the trade-off between estimation error and the optimal period of the most recent sampling instant, with the convergence of estimation error with the maximum permitted sampling interval. Moreover, the conditions for exponential stability are developed using the Lyapunov–Krasovskii functional technique. Next, a coordinated FDI attack detection strategy is developed based on the dual nonlinear minimization problem. The proposed attack detection and secure state estimation strategies are tested on the IEEE 13-node system. Simulation results show that these schemes are effective in enhancing attack detection based on asynchronous measurements or compromised data.

asynchronous measurements↗

Reactor System Demonstration with Cyber-Attack Scenarios Using CrowPis and Arduino Microcontrollers

This study covers developing and simulating nuclear reactor system using CrowPis and Arduino microcontrollers for demonstrating cyber-attack scenarios. The team was tasked with implementing more sensors and cybersecurity aspects to the reactor program that was created by last year’s high school interns. The team received the opportunity to collaborate and obtain advice from multiple university interns that helped us gain a better perspective of our project. Our mentor’s background in nuclear science was pivotal to our understanding what we could add to the reactor program to make it as realistic as possible. The first week of our internship was spent reading as much material as possible to gain an understanding of and the background for cyber-attacks and nuclear science. Nuclear science was a new horizon for each of the high school interns on the team, so spending this time in the beginning of our internship was crucial to our success. For the remaining portion of our internship, the team collectively did our best to implement as many sensors and use as much hardware as we could to make an accurate representation of a nuclear reactor in the program that was created. This internship was a big learning experience for everyone on the team. We all gained so many insights into the nuclear world and how it can benefit our lives, as well as how so many moving pieces are needed for it to work properly.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Adaptive Deep Reinforcement Learning Algorithm for Distribution System Cyber Attack Defense With High Penetration of DERs

With grid modernization, smart inverters are increasingly used to execute advanced controls for distribution network reliability. However, this also increases the cyber-attack space. Here this paper focuses on the defense approaches to restore the system to normal operation circumstances in the presence of cyber-attacks. A unique deep reinforcement learning (DRL) method is developed to minimize voltage violations and reduce power losses for impacted feeders. The defense problem is reformulated as a Markov decision-making process to dynamically control DERs while minimizing load shedding. This is achieved via an improved soft actor-critic (SAC)-based DRL algorithm, which can govern DER set points and load-shedding scenarios in discrete and continuous modes via the auto-tune entropy and Gaussian policy features. Numerical comparison results on the modified IEEE 123-node system with other control approaches, such as Volt-VAR (VV), Volt-Watt (VW), and model predictive control (MPC) show that the proposed method can eliminate voltage violations and provide feasible control actions that perform complete mitigation of cyber-threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Advancing Cyber-Attack Detection in Power Systems: A Comparative Study of Machine Learning and Graph Neural Network Approaches

This paper explores the detection and localization of cyber-attacks on power systems, focusing on comparing conventional machine learning (ML) and deep learning methods, and graph neural network (GNN)-based techniques. We assess the detection accuracy of these approaches and their potential to pinpoint the locations of specific buses under attack. Given the demonstrated success of GNNs in other time series anomaly detection applications, we aim to evaluate their performance within the context of power systems cyber-attack. Utilizing the IEEE 68-bus system, we simulated four types of attacks to test the selected approaches. Our results indicate that GNN-based methods outperform conventional machine learning and deep learning models in detection. Additionally, GNNs show promise in accurately localizing attacks for simple scenarios, although they still face challenges in more complex cases.

artificial intelligence↗

Cyber-Attack Methods, Why They Work on Us, and What to Do

Basic cyber-attack methods are well documented, and even automated with user-friendly GUIs (Graphical User Interfaces). Entire suites of attack tools are legal, conveniently packaged, and freely downloadable to anyone; more polished versions are sold with vendor support. Our team ran some of these against a selected set of projects within our organization to understand what the attacks do so that we can design and validate defenses against them. Some existing defenses were effective against the attacks, some less so. On average, every machine had twelve easily identifiable vulnerabilities, two of them "critical". Roughly 5% of passwords in use were easily crack-able. We identified a clear set of recommendations for each project, and some common patterns that emerged among them all.

cybersecurity↗

Robust Distribution State Estimation for Reliable Locational Marginal Pricing under Cyber-Attacks

Here this paper examines the impact of false data injection (FDI) cyber-attacks on distribution system state estimation (DSSE) and the resulting distribution locational marginal price (DLMP) in power markets. Two robust high-breakdown regression estimators, namely S- and MM- estimators, are implemented to provide resistance against FDI attacks targeting measurements and grid topology, creating leverage points. The introduced estimators are compared to the weighted least squares (WLS) with a bad data detection and rejection module (BDD) and the robust Huber M-estimator. The proposed estimators are shown to be effective and compare favorably to both existing Huber M- and the WLS with BDD in the presence of topology FDI attacks. Both the S- and MM-estimators provide good performance in the case of clean and corrupted measurements. Their performance is comparable in this case to the Huber M- and the WLS, followed by a BDD module. The simulation considered a modified distribution IEEE 13 and 34-bus systems where the impact of FDI attack scenarios is shown on the state and the DLMP pricing in the presence of distributed Generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Dynamic Cyber-Attack Diagnosis in Power Electronics Systems Based on Few-Shot Learning

With increasing exposure to software-based sensing and control, power electronics systems are facing higher risks of cyber-physical attacks. To ensure system stability and minimize potential economic losses, it is critical to monitor the operating states and detect those attacks at the early stage. However, anomaly detection and diagnosis of attacks are still challenging, especially when labeled anomaly data is difficult or even infeasible to obtain. To overcome this problem, we propose a Few-Shot Learning (FSL) based approach for cyber-attack diagnosis leveraging the waveform data. To the best of our knowledge, this work is the first attempt at leveraging FSL for cyber-attack diagnosis in power electronics systems. Extensive experimental results demonstrate that our proposed approach can achieve comparable diagnosis accuracy with the state-of-the-art data-driven methods using less than 0.04% of the training samples.

Li, Qi↗

Resilient Design of Continuous-time Distributed Optimization Algorithm in the Presence of Cyber-attacks

This paper presents a continuous-time resilient distributed optimization algorithm based on competitive interaction design method on connected graphs in the presence of adversaries. Here, the competitive interaction method allows us to design a network that protects the multi-agent systems from adversaries without requiring high network connectivity. In addition, the proposed algorithm does not require the global information about the number of adversaries. First, we show that the proposed distributed algorithm solves the resilient distributed optimization problem with no attack on the communication links. Second, we show that the proposed continuous-time distributed optimization algorithm on connected graphs converges to the small neighborhood of the optimal solution in the presence of cyber-attacks onto the communication channel. Simulations are presented to illustrate our theoretical results.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

Johnson, Jay Tillay↗