Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

Protecting Accelerator Control Systems in the Face of Sophisticated Cyber Attacks

Cyber security for industrial control systems has received significant attention in the past two years. The news coverage of the Stuxnet attack, believed to be targeted at the control system for a uranium enrichment plant, brought the issue to the attention of news media and policy makers. This has led to increased scrutiny of control systems for critical infrastructure such as power generation and distribution, and industrial systems such as chemical plants and petroleum refineries. The past two years have also seen targeted network attacks aimed at corporate and government entities including US Department of Energy National Laboratories. Both of these developments have potential repercussions for the control systems of particle accelerators. The need to balance risks from potential attacks with the operational needs of an accelerator present a unique challenge for the system architecture and access model.

02 PETROLEUM↗

Hybrid Cyber-attack Detection in Photovoltaic Farms

Here, to address the cyber-physical security in PV farms, a hybrid cyber-attack detection is proposed in this manuscript. To secure PV farms, the proposed method integrates model-based and data-driven methods by fusing the detection score at the device and system levels. First, a model-based cyber-attack detection method is developed for each PV inverter. A residual between the estimation of the Kalman filter and measurement is calculated. By leveraging the calculated residual from all inverters, a squared Mahalanobis distance is developed for device detection score generation. At the system level, a convolutional neural network (CNN) is proposed to detect cyber-attack using the waveform data at the point of common coupling (PCC) in PV farms. To improve the CNN detection accuracy, a set of well-designed features are extracted from the raw waveform data. Finally, a weighted detection score fusion method is proposed to combine device and system detection scores by using their complementary strength. The feasibility and robustness of the proposed method are validated by testing cases and a comparative experiment.

14 SOLAR ENERGY↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems

The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.

Benders decomposition↗

A Graph-Based Impact Metric for Mitigating Lateral Movement Cyber Attacks

Most cyber network attacks begin with an adversary gain- ing a foothold within the network and proceed with lateral movement until a desired goal is achieved. The mechanism by which lateral movement occurs varies but the basic signa- ture of hopping between hosts by exploiting vulnerabilities is the same. Because of the nature of the vulnerabilities typ- ically exploited, lateral movement is very difficult to detect and defend against. In this paper we define a dynamic reach- ability graph model of the network to discover possible paths that an adversary could take using different vulnerabilities, and how those paths evolve over time. We use this reacha- bility graph to develop dynamic machine-level and network- level impact scores. Lateral movement mitigation strategies which make use of our impact scores are also discussed, and we detail an example using a freely available data set.

cyber security↗

Adaptive Hierarchical Cyber Attack Detection and Localization in Active Distribution Systems

Development of a cyber security strategy for the active distribution systems is challenging due to the inclusion of distributed renewable energy generations. Here this paper proposes an adaptive hierarchical cyber attack detection and localization framework for distributed active distribution systems via analyzing electrical waveforms. Cyber attack detection is based on a sequential deep learning model, via which even minor cyber attacks can be identified. The two-stage cyber attack localization algorithm first estimates the cyber attack sub-region, and then localize the specified cyber attack within the estimated subregion. We propose a modified spectral clustering-based network partitioning method for the hierarchical cyber attack ‘coarse’ localization. Next, to further narrow down the cyber attack location, a normalized impact score based on waveform statistical metrics is proposed to obtain a ‘fine’ cyber attack location by characterizing different waveform properties. Finally, compared with classical and state-of-art methods, a comprehensive quantitative evaluation with two case studies shows promising estimation results of the proposed framework.

42 ENGINEERING↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: Cyber Attack on Thyssenkrupp Blast Furnace 2014

The Cyber Attack on Thyssenkrupp Blast Furnace 2014 Precursor Analysis Report leverages publicly available information about the Thyssenkrupp Steel Mill cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. In December 2014, the German Government’s Federal Office for Information Security (BSI) released a report detailing a cyber attack on a German steel mill that occurred earlier that year, though exact dates and details of the attack were not revealed. While the report did not specify the name of the company, multiple sources identified the victim as one of Europe’s largest steel manufacturers, Thyssenkrupp AG. Further, Thyssenkrupp announced on 16 May of that year that Europe’s largest blast furnace, “Schwelgern 2,” located at its facility in Duisburg, Germany, would be offline for several weeks for repairs and upgrades, suggesting Schwelgern 2 was likely the target of the attack. The attack began in early 2014, when adversaries infiltrated the victim steel mill’s Information Technology (IT) network via a spearphishing campaign, then worked their way into the Operational Technology (OT) environment, where they executed software that caused denial of service, denial of control, and eventually a loss of control. This led to the blast furnace shutting down without proper safety procedures, resulting in catastrophic physical damage. No lives were lost in the incident, but ThyssenKrupp suffered $4 million in damage to the blast furnace and an additional $6 million in lost revenue. The adversaries required specialized knowledge and expertise in steel production, which enabled them to compromise a variety of internal systems and components across both IT and OT networks. The attack also demonstrated detailed knowledge of the industrial control systems (ICS) and production processes being used. This combination resulted in one of the earliest known publicly reported cybersecurity incidents resulting in physical damage to ICS equipment. Researchers and analysts identified 19 unique techniques (used in a sequence of 20 steps) utilized during the attack with a total of 454 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the Thyssenkrupp cyber attack were precursors to the triggering event. Analysis identified 369 observables associated with these precursor techniques, 316 of which were assessed to have an increased likelihood of being perceived in the 120 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implications of the 2015 and 2016 Ukrainian electric grid cyber attacks to nuclear power plants - 113

Nuclear plants can be vulnerable from electric grid cyber attacks. In December 2015 and December 2016, cyber attackers attacked the Ukrainian electric grid and 'turned off the lights' by opening substation protective relays. The 2015 cyber attacks targeted electric distribution systems and the 2016 cyber attacks targeted electric transmission systems. In order to accomplish the attacks, the cyber attackers compromised field control system devices to inject malware and then open protective relays in substations. There are some very significant implications to nuclear plant operations from hacking the substations and switchyard breakers that serve nuclear plants. The nuclear plant operational concerns are compromising protective relays to prevent relay protection that would result in damage to large electric equipment; spurious actuation of protective relays causing loss-of-offsite power (LOOP) conditions; and the closing and then reopening of protective relays out-of-phase with the grid causing the Aurora vulnerability damaging generators, Alternating Current (AC) motors, and transformers. All of these protective relay conditions have already occurred in actual or test conditions. The common thread to these scenarios are that switchyard and substation protective relays are out-of-scope of existing nuclear cyber security regulations yet, when compromised, have demonstrated impacts to nuclear plant operations and challenged safety systems. There is one other issue about an attack originating from a protective relay. That is, it would be irrelevant whether the nuclear plant system that would be impacted would have analog or digital instrumentation and control (I and C) systems because the impact is upstream of the I and C. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systems and methods for controlling an industrial asset in the presence of a cyber-attack

Systems and methods are provided for the control of an industrial asset, such as a power generating asset. Accordingly, a cyber-attack model predicts a plurality of operational impacts on the industrial asset resulting from a plurality of potential cyber-attacks. The cyber-attack model also predicts a corresponding plurality of potential mitigation responses. In operation, a cyber-attack impacting at least one component of the industrial asset is detected via the cyber-attack neutralization module and a protected operational impact of the cyber-attack is identified based on the cyber-attack model. The cyber-attack neutralization module selects at least one mitigation response of the plurality of mitigation responses based on the predicted operational impact and an operating state of the industrial asset is altered based on the selected mitigation response.

D'Amato, Fernando Javier↗

Probabilistic risk evaluation of cyber-attacks on a nuclear power plant safety - 205.5

By adopting digital technology in nuclear power plants (NPPs), the cyber-attack has been introduced as one of the newest dangerous threats. It is required to develop efficient defense strategies against possible cyber-attacks on NPPs. However, it is difficult to expect when, where, and how the cyber-attacks will occur because they are intended attacks. Therefore, the risk of cyber-attacks on NPP is getting more and more important. Probabilistic risk assessment (PRA), which is one of the most widely used methods in NPPs to assess the risk, is introduced. However, it is difficult to evaluate the risk of NPPs by cyber-attacks from only the existing PRA method. In this research, a new PSA method, which is based on existing PRA, is used for evaluating of cyber-attacks on NPP. In addition, the case studies were performed for the feasibility study using nuclear power plant PRA model. Through this study, the risk assessment of the cyber-attacks on the NPP is tried by using a previous PRA model. Also, several scenarios are assumed to proceed the risk assessment. The risk-assessment should be performed in future work containing more specific cyber-attack scenarios, and if possible, the risk assessment model should be developed. Finally, the risk of cyber-attacks on NPPs could be evaluated quantitatively. Also, the defense strategies could be deducted by a risk assessment based on the risk assessment results which is based on the proposed method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deconstructing the Nuclear Supply Chain Cyber-Attack Surface

The nuclear supply chain cyber-attack surface is a large, complex network of interconnected stakeholders and activities. The global economy has widened and deepened the supply chain resulting in larger numbers of geographically dispersed locations and increased difficulty ensuring the authenticity and security of digital assets. Although the nuclear industry has made significant strides in securing facilities from cyber-attacks, the supply chain remains vulnerable. This paper provides further details on each of the elements in the Digital I&C System Supply Chain Cyber-Attack Surface, including supply chain lifecycle activities, key stakeholders, touchpoints, and attack types. Deconstructing this attack surface provides insights into supply chain threats, vulnerabilities, and consequences. These insights will lead to improvements in cybersecurity supply chain risk analysis, development of new cybersecurity supply chain processes and tools, and enhancement of overall supply chain resilience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Attack Detection for Active Neutral Point Clamped (ANPC) Photovoltaic (PV) Converter using Kalman Filter

With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. Furthermore, the simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.

14 SOLAR ENERGY↗