Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber physical simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

Cyber-Physical Simulation of the Cold Startup of Solid Oxide Fuel Cell – Gas Turbine (SOFC-GT) Hybrid Systems

This work introduces experimental studies for the cold startup process (CPS) of the SOFC-GT hybrid system using the cyber-physical simulation approach. The physical gas turbine is coupled with a cyber-physical SOFC stack, which is represented using the integration of a real time dynamic SOFC model with physical components (e.g., pressure chamber, natural gas burner, etc.). Different ramp rates of the turbine speed were tested out during the startup processes. Bypass valves were also used to manipulate the airflow during SOFC-GT hybrid system start-up process. Different ramp rates enable the rapid start-up of the turbine to avoid surge and stall, meanwhile enable acceptable warm rate of the fuel cell stack without damaging the cell material. CPS can enable dynamic characterizations of highly integrated systems at lower cost.

Zhou, Nana↗

Cyber-Physical Simulation of an Innovative Solid Oxide Electrolysis Cell - Gas Turbine (SOEC-GT) Hybrid Energy System

To produce green hydrogen at scale and at low cost, the solid oxide electrolysis cell (SOEC) systems would be tied to renewable power sources (mainly solar and wind), leveraging zero-carbon electricity at low prices and even nearly free during overgeneration scenarios. However, due to the intermittency of renewable power generation, the SOEC system is subjected to rapid load transitions that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). This can result in fast degradation and thus greatly reduce the SOEC’s lifetime. Our team at the National Energy Technology Laboratory has demonstrated that the anode air flow can have a crucial role in SOEC thermal management. Typically, a higher air flow rate can help to mitigate the local temperature gradient distortion during rapid load transitions. To move a large amount of air, the gas turbine (GT; i.e., compressor-turbine-generator set) has been regarded as the most mature and efficient technology. In this presentation, we show the configuration and preliminary results of an innovative SOEC-GT hybrid energy system in a cyber-physical simulation (CPS) approach.

Zhang, Biao↗

NUMERICAL MODELING OF A SOLID OXIDE FUEL CELL FOR USE IN REAL-TIME SIMULATION AND CYBER-PHYSICAL SYSTEMS

Cyber-physical systems provide a mechanism with which to investigate the physical phenomena and behavior of traditionally cost-prohibitive or otherwise fragile equipment. For the National Energy Technology Laboratory (NETL), this approach resulted in the Hybrid Performance (Hyper) facility which features a gas turbine-SOFC hybrid cycle utilizing real turbomachinery and a simulated SOFC stack. This allows for the investigation of combined cycle performance and control strategies, in an exhaustive manner, both without fear of destroying delicate state-of-the-art fuel cells, and with the full accuracy of real-world turbomachinery. Issues arose between the transient response of the SOFC model being limited to a sample time of 80 milliseconds, due to the calculation time of the SOFC model taking on average 40 milliseconds to calculate for a given timestep with spikes in calculation time reaching the 80 millisecond threshold. In order to be able to match the speed of transients from the turbomachinery and likewise better discern transient behavior, it was determined that the SOFC model must be optimized to operate at a sample time of 5 milliseconds. Therefore, it is necessary to optimize the SOFC model in order to decrease the calculation time from around 40 milliseconds, down to at the most 5 milliseconds. To do this, both the electrochemical algorithm and the thermal algorithm used to simulate the physical behavior of the SOFC are investigated to determine where improvements can be made. To this end the rootfinding numerical recipes of the electrochemical algorithm are investigated as the complex electrochemistry requires a highly iterative nested dual convergence loop to resolve the voltage-current relationship, and likewise the temporal discretization of the thermal algorithm is modified for the sake of higher accuracy and stability. Ultimately the new electrochemical algorithm featuring higher order rootfinding schemes proves to be efficient enough to reach the sub 5 millisecond target, signifying an order of magnitude reduction in calculation time, and when coupled with the new temporal discretization similar calculation time characteristics show that a fully implicit, higher order temporal discretization can also successfully be used if desired. Ultimately this result means that the cyber-physical simulation system can operate at higher sample rates, and resolve transient events at significantly higher resolution and fidelity.

Arias, Jesus↗

A Cryptographic Method for Defense Against MiTM Cyber Attack in the Electricity Grid Supply Chain

Critical infrastructures such as the electricity grid can be severely impacted by cyber-attacks on its supply chain. Hence, having a robust cybersecurity infrastructure and management system for the electricity grid is a high priority. This paper proposes a cyber-security protocol for defense against man-in-the-middle (MiTM) attacks to the supply chain, which uses encryption and cryptographic multi-party authentication. A cyber-physical simulator is utilized to simulate the power system, control system, and security layers. The correctness of the attack modeling and the cryptographic security protocol against this MiTM attack is demonstrated in four different attack scenarios.

Paul, Shuva↗

Impact of Open Communication Networks on Load Frequency Control with Plug-In Electric Vehicles by Cyber-Physical Dynamic Co-Simulation

With the increasing electrification of the transportation sector to achieve the carbon neutrality objective, despite the challenges of charging electric vehicles (EV), there are also opportunities through smart charging EVs to improve system frequency stability; however, EV control technologies might require nontraditional communication support. This paper investigates the impacts of communication variations of EV on power system load frequency control through a cyber-physical dynamic system (CPDS) co-simulation. Here, the CPDS is built upon our previously developed transmission-and-distribution dynamic co-simulation model with the added communication variation functions (i.e., delay and packet loss). The case studies consider multiple communication variation scenarios when the system experiences an N-1 generation trip contingency. The scenarios include communication delays and packet loss using both homogeneous and heterogeneous assumptions. The outcomes of this work can help improve EV frequency regulation services and provide robust and effective tests for different load frequency control algorithms of the future power systems.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Demonstrating the Transient System Impact of Cyber-Physical Events Through Scalable Transmission and Distribution (T&D) Co-Simulation

Modern power systems become more vulnerable to cyber threats due to their growing interconnectivity, interdependence, and complexity. Widespread deployment of distributed energy resources (DERs) further expands the threat landscape to the grid edge, where fewer cybersecurity protections exist. In this article, a systematic cyber-physical events demonstration, enabled by an integrated transmission, distribution, and communication co-simulation framework, is performed. It analyzes cyber risks to power grid under DER-enabled automatic generation control from different angles. Unlike existing works, the simulation captures millisecond-to-minutes frequency and voltage transient dynamics at a cross-region system scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Open Communication Networks on Load Frequency Control with Plug-in Electric Vehicles by Cyber-Physical Dynamic Co-Simulation: Preprint

With the increasing electrification of the transportation sector, vehicle to grid (V2G) control technologies are promising to improving system frequency stability. However, these control technologies might require non-traditional communication supports. This paper investigates the impacts of electric vehicles (EVs) V2G on power system frequency regulation considering communication variations through transmission-distribution-communication (TDC) dynamic simulation. The simulation model is built based on our previously developed open-source transmission-and-distribution (T&D) dynamic co-simulation framework. Here, we add the communication variation functions (i.e. delay and packet loss) to complete the TDC simulation framework. In the case studies, practical communication variation scenarios are considered when the system experiencing an N-1 generation trip contingency. The considered scenarios include communication delay and packet loss using both homogeneous and heterogeneous assumptions. The delay and packet loss rate are the same in all communication channels in the homogeneous case but varies in the heterogeneous case. The results show the communication delay has an obvious impact on the frequency recovery compared to the communication packet drop. The impacts of the standard deviations of communication delay time and packet drop rate are not significant. The outcomes of this work can help improve the EV frequency regulation services and provide robust and effect supports to the grid.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

ARCADE (Advanced Reactor Cyber Analysis and Development Environment)

SAND2025-11780O ARCADE (Advanced Reactor Cyber Analysis and Development Environment) software performs cybersecurity experiments on Defensive Cyber Security Architectures (DCSA) for Distributed Control Systems (DCSs). The application is integrated into a cohesive environment that performs cyber risk analyses and reduces costs. ARCADE can investigate the entire cyber-attack surface of a DCS from the physics of control, down to the firmware of individual components with automated efficiency. ARCADE has five major functional components: the Data Broker system, the virtualization environment, the cyber-attack simulator, the cyber-physical analysis system, and the physics simulator. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Valme, Romuald↗

RESOLVING THE ELECTROCHEMICAL EQUATIONS OF A SOLID OXIDE FUEL CELL FOR USE IN TRANSIENT SIMULATION AND INTEGRATION INTO CYBER-PHYSICAL SYSTEMS

A major challenge with complex cyber-physical systems stems from long model computational time that creates a mismatch between the model system and the physical system. The numerical modeling of solid oxide fuel cells (SOFCs) presents particular challenges due to the highly coupled nature of the underlying equations and the multiphysics needed to fully resolve their behavior during a transient event. To this end current approaches revolve around splitting the computational efforts into resolving temperature effects and resolving electrochemical effects. Current methods employed for the transient simulation of an SOFC for implementation in the Hybrid Performance (HyPer) facility cyberphysical plant at the National Energy Technology Laboratory reveal a distinct need for accelerated results with a high degree of stability. To this aim, an investigation into the computational time for the code reveals that the underlying electrochemical algorithm takes an order of magnitude more time than its thermal counterpart and has a tendency to vary in terms of iteration time and as such a rework of the underlying system is proposed. The primary method for accelerated electrochemical algorithm solutions is to employ higher order root finding recipes for the resolution of the highly coupled electrochemical equations. This is done with the intention to reduce the overall number of subiterations necessary for resolving voltage, current density, and species concentration, properties of the fuel cell that are all directly coupled and require nested iterative approaches. The overall objective of this approach is an order of magnitude reduction in calculation time without sacrificing stability and increasing accuracy. Specific approaches involve using both bounded and unbounded techniques, such as the False Position method and the Secant method (or if applicable Newton-Raphson) respectively, the drawbacks being slower convergence for False Position and instability for the Secant or Newton-Raphson methods. Current preliminary results on simplified versions of the parent functions involved for electrochemical calculations indicate a reduction in computational steps by a factor of two for the secant method and a factor of three for Newton-Raphson. When implemented into new modified electrochemical algorithms, the results indicate a possible order of magnitude reduction in calculation time.

Arias, Jesus↗

Simulating Energy and Security Interactions in Semiconductor Manufacturing: Insights from the Intel Minifab Model

Semiconductor manufacturing is a highly complex. Fabrication plants must deal with re-entrant flows to support multiple types of wafers being produced simultaneously, each with their own deadlines and specifications. The manufacturing process itself depends upon the ability to control and programmatically adjust a variety of environmental conditions including temperature, humidity, and air quality. In addition, wafer fabrication consumes large amounts of electricity. Emerging technologies may help reduce the energy footprint of such facilities but can introduce cybersecurity risks. Therefore, this paper presents a modeling and simulation framework to quantify tradeoffs between operational measures of performance, energy consumption, and cybersecurity controls. We augment the Intel Minifab model, with the Purdue Enterprise Reference Architecture (PERA) for cybersecurity as well as tool-level energy consumption data from a real-world semiconductor manufacturing testbed. In this manner, we intend to provide stakeholders with a systematic, data-driven approach to evaluate emerging risks within the manufacturing process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (a five-lab demonstration) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, photovoltaics, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactors, control centers, and gas turbines, across five U.S. Department of Energy (DOE) national laboratories: National Laboratory of the Rockies (NLR), Idaho National Laboratory, National Energy Technology Laboratory, Lawrence Berkeley National Laboratory, and Sandia National Laboratories. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance DOE network, and are controlled via a centralized energy controller hosted at NLR's Advanced Research on Integrated Energy Systems facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Defensive Cybersecurity Architecture Design Using Force-on-Force Cyber-Physical Modeling

Currently, nuclear power plant physical security systems are highly dependent on air-gaps as a protective measure against cyber-threats. Cyber-physical threats become more likely as advanced cyber-threat capabilities to jump air-gaps transition into common use. Defending against the emerging threat of cyber-enabled physical intrusions is poorly understood. The consequence of these cyber-physical attacks has no quantitative analysis method to inform risk-informed, performance-based cybersecurity approaches. By modifying the physical security simulation tool Dante, cyber-physical threat consequence was able to be analyzed on a notional facility. The results of this analysis are used to design a Defensive Cybersecurity Architecture (DCSA) for the physical security system to produce example resilience measures for this notional facility. A DCSA defines security levels to provide a graded approach for defending plant functions, and security zones for trusted communication between systems. This approach can be applied to real world systems to produce physical protection systems and response measures that are resilient to cyber-physical threats.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗