Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyclotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mode structure measurements of ion cyclotron emission and sub-cyclotron modes on DIII-D

We report mode structure measurements of coherent ion cyclotron emission (ICE) and sub-cyclotron modes on DIII-D. Through a dedicated experiment, we aimed to characterize a variety of modes via the upgraded ICE diagnostic in both L- and H-mode plasmas. In the L-mode plasmas, autopower spectrum peaks at harmonics of the ion cyclotron frequency fci were observed and are localized in the core of the plasma. Sub-cyclotron modes (f ~ 0.5f ci ) were also observed in L-mode plasmas when the toroidal magnetic field strength was lowered from B T = 2.17 T. In H-mode plasmas, many ICE harmonics localized to the plasma edge were observed, with some exceeding the nominal ICE diagnostic bandwidth of f ϵ [0, 100] MHz. Polarization estimates made using an orthogonal pair of vertical and horizontal magnetic pickup loops on the outer wall of the machine indicate that ICE and sub-cyclotron modes have compressional polarization at the plasma edge, the latter being consistent with simulation efforts for comparable DIII-D plasmas. For all modes, the same harmonics are observed on both the centerpost and outer wall loops, indicating that ICE is poloidally extended. Finally, toroidal mode numbers were calculated using three outer wall loops for both core ICE and sub-cyclotron modes in L-mode plasmas. Furthermore, the sub-cyclotron case served as a benchmark for our calculation method, with measured numbers of n ϵ [–24, –18] roughly agreeing with heuristic estimates of n ϵ [–20, –13]. Core ICE mode numbers were measured to be n ϵ [–10, 5], which is comparable to measurements made on other machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: III. Novel sub-cyclotron modes

Dedicated DIII-D experiments studied instabilities above and below the ion cyclotron frequency by injecting thirteen different neutral beam populations into L-mode plasmas with different thermal compositions of H, D, and 3 He at five different values of toroidal field. Two companion papers describe the results of these experiments in detail. This paper focuses on data and analysis of two instabilities that occur at ${\sim}0.6$ of the deuterium and hydrogen cyclotron frequencies $f_\mathrm {cD}$ and $f_\mathrm {cH}$ in mixed hydrogen and deuterium plasmas. The modes below $f_\mathrm {cD}$ are often driven unstable by deuterium beams but are rarely destabilized by hydrogen beams. The modes below $f_\mathrm {CD}$ are reported here for the first time in a fusion plasma. These $\mathrm{sub-}f_\mathrm {cH}$ modes are only driven by deuterium beams but, unlike the $\mathrm{sub-}f_\mathrm {cD}$ modes, they are only unstable in plasmas with deuterium concentrations that are ${\lesssim}20\%$; they also have a smaller amplitude than the sub-deuterium modes. Addition of fully-ionized 3 He to the plasma has little effect on the sub-cyclotron deuterium modes but is stabilizing for the sub-cyclotron hydrogen modes. The modes are excited in the core and have toroidal mode numbers around 20. These trends are compared with calculations of the growth rate in a simplified model. The theory successfully predicts global Alfvén eigenmode instability with frequencies and mode numbers close to experimental values, the stronger amplitude of the sub-deuterium modes, and the species-mix dependence of the sub-hydrogen modes. Increased damping associated with the ion-ion hybrid, cutoff, and crossover frequencies plausibly accounts for the stabilization of the $\mathrm{sub-}f_\mathrm {cH}$ modes when 3 He is puffed. However, the relative stability of $\mathrm{sub-}f_\mathrm {cH}$ modes during hydrogen injection remains unexplained.

electromagnetic ion cyclotron instability↗

Cyclotron breaking: a mechanism for parallel ion cyclotron waves to heat the fast solar wind

The Parker Solar Probe mission has observed near-continuous power in parallel ion cyclotron waves (PICWs) in the young, fast solar wind. These waves are unlikely to be directly produced by the turbulent cascade and are likely born of a local instability; yet, they are observed to both cool – and heat – the plasma. We propose that these observations can be self-consistently explained as the natural consequence of PICWs propagating in the inhomogeneous solar wind after they have been driven unstable. In this work, we argue that strong proton heating by a turbulent cascade of oblique ICWs will result in PICWs being driven unstable in a process known as quasi-linear focusing. Because the power in the turbulent cascade is concentrated at scales above the turbulent transition region, PICWs will be driven unstable within a range of wavenumbers parallel to the background magnetic field, 𝑘 ∥ , that is bounded from above by 𝑘$^{∗}_{∥P}$, corresponding to the start of the transition region. As unstable PICWs propagate away from the Sun to regions of lower proton density, their 𝑘 ∥ , multiplied by the proton inertial length 𝑑 p , increases. Eventually, 𝑘$^{∗}_{∥P}$ of the PICWs becomes larger than 𝑘$^{∗}_{∥P}$⁢𝑑 p and the waves damp, heating the solar wind. We call this effect ‘cyclotron breaking’, in analogy with ocean waves breaking on the shore. We then discuss the testable predictions of the theory, including a distinct heating signature in which PICWs cool fast protons and heat slow protons at any given heliocentric distance 𝑟. Finally, we conjecture that cyclotron breaking can lead to net heating by PICWs if the power emitted as PICWs decreases sufficiently rapidly with 𝑟 that local emission of PICWs is overwhelmed by the local damping of PICWs generated closer to the Sun.

plasma heating↗

Novel Strategy To Analyze Fourier Transform Ion Cyclotron Resonance Mass Spectrometry Data of Biomass Pyrolysis Oil for Oligomeric Structure Assignment

Among the most prominent challenges for the analysis of biomass pyrolysis products is the characterization of the abundant oligomer fraction of bio-oil. This fraction is principally made up of pyrolytic lignins and dehydrated, highly modified sugar oligomers, called humins, in liquid phase. An emerging technique for analysis of this oligomer fraction is high-resolution Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS), which allows for accurate determination of C x H y O z formulae for detected oligomers. Additionally, using simple dehydration and fragmentation reaction schemes, similar formulae can be developed from cellulose-, hemicellulose- and lignin-derived oligomers, which are primary depolymerization products. In this paper, FT-ICR MS analysis is coupled with combinatoric dehydration and fragmentation modeling in order to match experimentally detected bio-oil oligomers with hypothetical pathways for their formation during pyrolysis. In this way, we present a novel strategy by which oligomeric structures can be proposed for bio-oils. Using this approach, it becomes possible to advance the understanding of both the molecular structures comprising the bio-oil oligomer fraction and the pathways by which these structures form during biomass pyrolysis reactions.

09 BIOMASS FUELS↗

Vacuum Pyrolysis of Hybrid Poplar Milled Wood Lignin with Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry Analysis of Feedstock and Products for the Elucidation of Reaction Mechanisms

The pyrolysis of lignocellulosic materials is a promising technique to produce fuels and chemicals. It is well known that the most abundant products of lignin pyrolysis are oligomeric molecules, known as pyrolytic lignin (PL). The chemical composition of PL has been extensively studied; however, there is still an important debate whether these oligomers are produced directly from the lignin or from the recombination of monomeric pyrolytic products. Existing theories are unable to describe the effect of vacuum on the distribution of pyrolysis products. Hybrid poplar milled wood lignin (MWL) was initially isolated and thoroughly characterized by Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). Chemical formulas were assigned to each oligomeric compound detected. The MWL was also subjected to vacuum pyrolysis in a modified pyroprobe at 250, 750, and 1000 mbar (absolute pressure), and the resulting liquid products were analyzed by FT-ICR MS. A new strategy to assign structural representations to the oligomeric PL products is proposed, based on the plausible pyrolysis reaction mechanisms of depolymerization/fragmentation applied to original MWL oligomer formulas. Our results support the hypothesis that PL is formed from the removal of moieties from primary lignin pyrolysis products with between three and five aromatic rings. This depolymerization/fragmentation allows the oligomers to reduce their molecular weights to the point where they can be removed from the reaction zone by direct vaporization. Furthermore, this phenomenon highlights the importance of pressure on removal mechanisms and their impact on the molecular weight of the resulting products from lignin pyrolysis.

09 BIOMASS FUELS↗

Radiation modeling and experimental validation of sub-cyclotron frequency microwave synchrotron radiation as a diagnostic tool for runaway electrons in present and future tokamaks

The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.

Yu, Guanying [Hefei Comprehensive National Science↗

The cyclotron gas stopper at FRIB getting ready for operations

Linear gas stopping cells have been used for nearly two decades to slow down projectile fragments at the National Superconducting Cyclotron Laboratory, now the Facility for Rare Isotope Beams, for experiments with low-energy and reaccelerated beams. In order to efficiently stop and rapidly extract light to medium-mass fast ions, a cyclotron gas-stopper has been constructed. It uses a cyclotron-type magnet and a helium-gas filled stopping chamber to slow down the injected beam. RF ion guides transport the stopped ions to the center of the magnet and axially through the bore before acceleration to <60 keV. Following successful offline tests, the cyclotron stopper was moved to an experimental vault and connected to a new momentum–compression beam line. Beam transport to and into the cyclotron stopper was tested with stable beams. Finally, using 46 K fragments, the first successful stopping and extraction of a high-energy beam with the cyclotron stopper was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Evolution of the cyclotron mass with doping in La 2–x Sr x CuO 4

The recent observation of cyclotron resonance in optimally doped La 2–x Sr x CuO 4 using time-domain THz spectroscopy in high magnetic field has given new possibilities for the study of cuprate superconductors. One can measure the cyclotron mass in the more disordered cuprates possessing short scattering times, therefore expanding the study to materials and dopings in which quantum oscillations have not been observed. In this paper we present the measurement of the carrier mass of the hole-doped cuprate La 2–x Sr x CuO 4 across a range of dopings spanning from the slightly underdoped (p=0.13) to highly overdoped (p=0.26), near the termination of the superconducting dome. These results reveal a systematic increase of m c with doping, up to values greater than 13 times the bare electron mass. This is in contrast with the masses extracted from the heat capacity, which show a peak near the pseudogap critical point p* and/or Lifshitz transition. The cyclotron frequency is linear in field up to 31 T for all dopings, giving no evidence for field-induced Fermi surface reconstructions. The cyclotron mass is found to be positive for all dopings, but with a magnitude systematically below the heat-capacity mass for under and optimally doped samples, while exceeding it for overdoped samples. Among other aspects, these results are surprising as photoemission reveals a Lifshitz transition in the middle of our doping range and the sign of the cyclotron mass determined from a finite-frequency resonance is, in conventional theories, a topological quantity only sensitive to whether or not the Fermi surface is closed around holes or electrons. We see no sign of a divergence of the mass near p* nor near the Lifshitz transition, showing that any singularity, if it exists, is not strong enough to affect the cyclotron mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: I. Stability

Ion cyclotron emission (ICE) driven by fast ions has the potential to be a reactor relevant diagnostic of confined and escaping fast ions; moreover, controlled experiments in magnetic fusion devices can shed light on similar magnetospheric instabilities below and above the ion cyclotron frequency f ci . Dedicated DIII-D experiments studied instabilities below f ci and at cyclotron harmonics l f ci by injecting thirteen different neutral beam populations into plasmas with different thermal compositions of H, D, and 3He at five different values of toroidal field. High-frequency magnetic loops diagnose mode properties. Each beam type is individually injected for an approximate slowing-down time (~100 ms), resulting in a database of 2529 conditions that are analyzed in frequency bands corresponding to ICE harmonics and < f ci global Alfvén eigenmodes. The sub-cyclotron modes are more unstable at low field and in plasmas with large H concentration. For D injection, first harmonic ICE at f cD is more unstable in hydrogen plasmas but, for H injection, the converse is true (ICE at f cH is more unstable in D), suggesting that thermal same-species ions damp fundamental ICE. ICE stability also depends upon the pitch-angle anisotropy gradient and upon the ‘bump-on-tail’ gradient ∂f/∂v. Although the frequency of unstable ICE in these plasmas always occurs near the central cyclotron frequency, the precise value also depends on the Alfvén speed and beam direction, consistent with the idea that instability occurs for modes that simultaneously satisfy ω ≃ 2πlf ci , the magnetosonic dispersion relation, and the Doppler-shifted resonance condition.

electromagnetic ion cyclotron instabilities↗

Larmor power limit for cyclotron radiation of relativistic particles in a waveguide

Cyclotron radiation emission spectroscopy (CRES) is a modern technique for high-precision energy spectroscopy, in which the energy of a charged particle in a magnetic field is measured via the frequency of the emitted cyclotron radiation. The He6-CRES collaboration aims to use CRES to probe beyond the standard model physics at the TeV scale by performing high-resolution and low-background beta-decay spectroscopy of 6 He and 19 Ne. Having demonstrated the first observation of individual, high-energy (0.1–2.5 MeV) positrons and electrons via their cyclotron radiation, the experiment provides a novel window into the radiation of relativistic charged particles in a waveguide via the time-derivative (slope) of the cyclotron radiation frequency, df c /dt. We show that analytic predictions for the total cyclotron radiation power emitted by a charged particle in circular and rectangular waveguides are approximately consistent with the Larmor formula, each scaling with the Lorentz factor of the underlying e ± as γ 4 . This hypothesis is corroborated with experimental CRES slope data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single radio frequency bucket injection in the 88-Inch Cyclotron using a pulsed high voltage chopper

A single radio frequency bucket of the 88-Inch Cyclotron is filled using a fast chopper located in the axial line. The bucket then accelerates until it reaches the deflector, at which point, it is extracted as a train of bunches. This phenomenon can be attributed to the characteristic multi-turn extraction of the cyclotron and, by simplifying the complex dynamics of a cyclotron, corresponds to the conceptual transfer function of the cyclotron. In conclusion, the confirmation of the single radio frequency bucket injection was achieved by operating the cyclotron in the third harmonic mode and observing the absence of intermediate bunches during the multiple-bunch extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion cyclotron emission in Maxwellian plasmas

Destabilization of ion cyclotron waves—waves with frequencies close to ion cyclotron harmonics—in inhomogeneous plasmas with Maxwell velocity distribution is considered. A new mechanism of destabilization of these waves is found, whereas the known interaction between cyclotron waves and drift waves is shown to be hardly able to lead to instabilities in realistic tokamak plasmas. Our finding is that the resonance wave–particle interaction in the presence of temperature gradient can change the diamagnetic drift frequency in such a way that the destabilizing influence of the diamagnetic drift exceeds Landau damping. This occurs when the energy of resonance particles is sufficiently high, which is always the case due to the infinite tail of the Maxwell distribution. Particles with higher energies provide a larger ratio of drive to damping, but the number of resonance particles and, thus, instability growth rates are exponentially small when particle energy is very high. Therefore, only moderately suprathermal particles can lead to observable instabilities. A condition for instabilities driven by these particles is obtained. Destabilization of electrostatic cyclotron waves and ordinary cyclotron waves is studied.

Kolesnichenko, Ya. I. (ORCID:0000000323219681)↗

Novel internal measurements of ion cyclotron frequency range fast-ion driven modes

Abstract Novel internal measurements and analysis of ion cyclotron frequency range fast-ion driven modes in DIII-D are presented. Observations, including internal density fluctuation ( n ~ ) measurements obtained via Doppler backscattering, are presented for modes at low harmonics of the ion cyclotron frequency localized in the edge. The measurements indicate that these waves, identified as coherent ion cyclotron emission (ICE), have high wave number, k ⊥ ρ fast ≳ 1, consistent with the cyclotron harmonic wave branch of the magnetoacoustic cyclotron instability, or electrostatic instability mechanisms. Measurements show extended spatial structure (at least ∼1/6 the minor radius). These edge ICE modes undergo amplitude modulation correlated with edge localized modes (ELM) that is qualitatively consistent with expectations for ELM-induced fast-ion transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Radionuclide Production Capabilities at the Duke University Medical Center Cyclotron with a Focus on Astatine-211

Radionuclides play an important role in a diverse array of fields including physics, chemistry, agriculture, materials science, national security, medical research and patient care. Establishing a reliable domestic supply of key radionuclides is critical to our national competitiveness in these areas. Regarding medical applications, targeted alpha-particle therapy (TAT) has become of great interest to basic researchers and clinicians alike and is emerging as a valuable and cost-effective approach for cancer treatment. Unfortunately, progress in TAT, particularly with regard to its clinical translation, has been severely hampered by the limited availability of the most promising radionuclides at a reasonable cost, and with appropriate chemical and radiochemical purity. In this project, we have attempted to address this problem by focusing on production of the 7.2-h half-life α-particle emitter, 211 At, which has long been considered to be one of the most promising radionuclides for TAT. We note that he critical importance of improving the supply of 211 At in the United States was noted in the Funding Opportunity Announcement related to this project. At Duke University, we have a CS-30 cyclotron that is one of the few accelerators in the United States that has an alpha-particle beam that has enough energy to make useful quantities of 211 At. With this cyclotron, we have been able to produce more 211 At than anywhere else in the world because of our unique internal cyclotron target system. However, the CS-30 cyclotron is nearly 40 years old and was no longer reliable. In addition, its operation required considerable skill, largely because it had analog control systems, and vital parts including old-fashioned power supplies, were becoming unavailable. For these reasons, the current project was undertaken to evaluate all the subsystems of the CS-30 cyclotron and replace, repair, and update them. With help from our consultant, Ionetix, this has now been accomplished. We believe that because of this work, the CS-30 can reliably supply 211 At for basic research and clinical trials both at Duke and beyond.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cyclotron resonance accelerators for industrial applications

Here, this paper describes novel configurations for cyclotron resonance acceleration of electrons and ions that have several attractive features including: a compact robust room-temperature single-cell RF cavity as the accelerator structure; and continuous high current accelerated un-bunched beam output with self-scanning, obviating need for a separate beam scanner. An electron accelerator version, the electron Cyclotron Resonance Accelerator (eCRA), is under development to be an efficient source for high power electron and x-ray beams for medical, research, sterilization, and National Security applications, so as to replace radioactive materials. An ion accelerator version, the ion Cyclotron Auto-Resonance Accelerator (iCARA) is described here, suggesting its potential to produce, as an example, a high-current multi-MeV beam of deuterons which could be highly competitive with that produced either with linacs or cyclotrons. Such a deuteron beam could produce a high flux of fast neutrons via deuteron stripping, for applications including the transmutation of used nuclear fuel, material studies relevant for a fusion reactor inner wall, tritium breeding and medical isotope production. For the high-current, high efficiency simulated performance for eCRA and iCARA as described in this paper, the particle beams produced may not exhibit the low emittance values that are important for most discovery research. Rather, the beams could be useful for industrial applications where higher emittance and some energy spread can be tolerated, in favor of high beam power.

43 PARTICLE ACCELERATORS↗

First Observation of Cyclotron Radiation from MeV-Scale e ± following Nuclear β Decay

We present an apparatus for detection of cyclotron radiation yielding a frequency-based β ± kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear β decays. The cyclotron frequency of the radiating β particles in a magnetic field is used to determine the β energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of β – ’s from 6 He and β + ’s from 19 Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for β spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic β’s in a waveguide. Furthermore, this work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision β-decay measurements.

43 PARTICLE ACCELERATORS↗