A Multiagent Deep Reinforcement Learning-Enabled Dual-Branch Damping Controller for Multimode Oscillation

Here, this study develops a multiagent deep reinforcement learning (MADRL)-enabled framework for the decentralized cooperative control of a novel dual-branch (DB) damping controller for both low-frequency oscillation (LFO) and ultralow-frequency oscillation (ULFO). It has two branches, each of which consists of a proportional resonance (PR) and a second-order polynomial that is designed to handle target oscillation modes. To improve the robustness of the controller to system uncertainties, MADRL is developed, where multiagents are centrally trained to obtain the coordinated adaptive control policy while being executed in a decentralized manner to provide the optimal parameter setting for each controller with only local states. Comparisons with the IEEE 10-machine 39-bus system demonstrate that the proposed method achieves better robustness to uncertainties, lower communication delay, and single-point failure, as well as damping control performances for both LFO and ULFO.

97 MATHEMATICS AND COMPUTING↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the IEEE 73-bus reliability test system (RTS) case via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

Hardware-in-the-Loop Testing of Wide-Area Damping Controller for Field Implementation in Large-scale Power Grid

In our previous work, an adaptive measurement-driven wide-area damping controller (WADC) for suppressing inter-area oscillations has been proposed and a hardware prototype was developed and validated through hardware-in-the-loop tests. As a continuation of the work, this paper introduces a WADC software prototype to handle the realistic challenges for field implementation in the control room of the power grid. The WADC software is developed and operated as an openPDC adapter with a graphical user interface (GUI) to monitor the WADC inputs and output, the communication delays and other variables. The software prototype has been fully tested through an enhanced hardware-in-the-loop (HIL) test setup. Its performance is verified under various realistic communication uncertainties, such as random time delays and data losses, with different communication protocols. The experiment results have proven the WADC software can deliver sufficient damping to suppress the targeted oscillation mode in handling various communication uncertainties for future field deployment.

Jia, Xinlan↗

Characterization and Damping Control of Mechanical Connections to Improve Performance of Horn Stripline

Magnetic focusing horns are critical components for creating a stable beam of neutrinos for neutrino facilities, such as the Long Baseline Neutrino Facility (LBNF) and the Neutrinos and Main Injector (NuMI) beam lines at Fermilab. The pulsed magnetic horns are powered by high current electricity through long striplines, which must survive in a harsh radiation environment for the operational life of the component. Each stripline assembly consists of four layers of Al 6101-T6. As an electro-mechanical system, the stripline layers are bolted together with ceramic isolators for electrical insulation and to facilitate passive cooling and mechanical stability. The striplines experience vibrational force in addition to clamping force, repetitive thermal and electro-magnetic loading. The holes of stripline plates for ceramic joints represent one of the weak links for potential failure. Damping can be achieved by adding damp material to the joint. By characterizing behavior of the joint and optimizing their damping properties through FEA and EMA, the stripline performance and longevity can be improved. Appropriate damp materials are the key.

Liu, Zunping [Fermilab]↗

Characterization and Damping Control of Mechanical Connections to Improve Performance of Horn Stripline

Magnetic focusing horns are critical components for creating a stable beam of neutrinos for neutrino facilities, such as the Long Baseline Neutrino Facility (LBNF) and the Neutrinos and Main Injector (NuMI) beam lines at Fermilab. The pulsed magnetic horns are powered by high current electricity through long striplines. In addition to requirements for low inductance and voltage standoff, the striplines must survive in a harsh radiation environment for the operational life of the component, specified as the 100 million pulses requirement for LBNF. Each stripline assembly consists of four (eight layers that splits off to 2 pairs of four layers at the horn interface) layers of Al 6101-T6. As an electromechanical system, the stripline layers are bolted together with ceramic isolators for electrical insulation and connections must facilitate passive cooling and mechanical stability. The striplines experience vibrational force in addition to clamping force, repetitive thermal and electro-magnetic loading. The holes of stripline plates for ceramic joints represent one of the weak links for potential failure [1,2]. By characterizing the contact behavior of these joints and optimizing their damping properties through finite element analysis and experimental modal analysis, stripline performance and longevity can be improved. This study not only helps predict the behavior of the striplines but also improves their performance to meet the required operational lifetime.

Liu, Zunping [Fermilab]↗

Control rod damping system

A damping area or “dash pot” on the upper ends of control rods absorb energy from dropped control rod assemblies without narrowing the diameter of guide tubes. As a result, coolant can freely flow through the guide tubes reducing boiling water issues. The dampening area reduces a separation distance between an outside surface of the control rod and an inside surface of the guide tubes decelerating the control rods when entering a top end of the guide tubes. In another example, the dampening area may be located on a drive shaft. The dampening area may have a larger diameter than an opening in a drive shaft support member that decelerates the drive shaft when dropped by a drive mechanism.

Snuggerud, Ross Douglas↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To damp harmonic resonance, this paper proposes an adaptive narrowband damping control that automatically programs, adds, and adjusts the damping around the oscillation frequency when an oscillation is detected. First, the paper presents a low-pass filter design for MMC control loops that pushes all negative damping of the MMC impedance down to the medium-frequency range (< ~ 1000 Hz). Then, an adaptive damping control that uses online oscillation detection is proposed, which can automatically configure the narrowband damper to provide positive damping to the MMC around the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper dynamically adjusts the damping gain and the width of the damping range based on continuous monitoring of system resonance conditions (e.g., adjust damping gain to zero when the system resonance disappears). Electromagnetic transient simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Forced Oscillation Grid Vulnerability Analysis and Mitigation Using Inverter-Based Resources: Texas Grid Case Study

Forced oscillation events have become a challenging problem with the increasing penetration of renewable and other inverter-based resources (IBRs), especially when the forced oscillation frequency coincides with the dominant natural oscillation frequency. A severe forced oscillation event can deteriorate power system dynamic stability, damage equipment, and limit power transfer capability. This paper proposes a two-dimension scanning forced oscillation grid vulnerability analysis method to identify areas/zones in the system that are critical to forced oscillation. These critical areas/zones can be further considered as effective actuator locations for the deployment of forced oscillation damping controllers. Additionally, active power modulation control through IBRs is also proposed to reduce the forced oscillation impact on the entire grid. The proposed methods are demonstrated through a case study on a synthetic Texas power system model. The simulation results demonstrate that the critical areas/zones of forced oscillation are related to the areas that highly participate in the natural oscillations and the proposed oscillation damping controller through IBRs can effectively reduce the forced oscillation impact in the entire system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Damping inter-area oscillation using reinforcement learning controlled TCSC

Appropriate damping control of the inter-area oscillation would ensure the grid stability and maintain the tie-line power transfer capability. In this paper, we proposed a novel reinforcement learning (RL) based power oscillation damping (POD) controller that uses Thyristor Controlled Series Compensators (TCSC) to damp inter-area oscillations. By leveraging the unbiased gradient direction estimation of the natural evolution strategy (NES), we successfully regulated the power flows on the tie-lines and damped inter-area oscillations through dynamically modulating the inserted reactance of the TCSC. The proposed RL-based POD controller has been tested on both two-area four-machine system and North American Minni-WECC system. Extensive studies have demonstrated the excellent performance of the proposed RL-based TCSC POD controller in damping inter-area oscillations.