Search NASA⌕ Search

SEARCH · Search NASA

Results for “dark photons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Supernova Bounds on the Dark Photon Using Its Electromagnetic Decay

The hypothetical massive dark photon (gamma′) which has kinetic mixing with the SM photon can decay electromagnetically to e+ e− pairs if its mass m exceeds 2m(sub e), and otherwise into three SM photons. These decays yield cosmological and supernovae associated signatures. We briefly discuss these signatures, particularly in connection with the supernova SN1987A, and delineate the extra constraints that arise on the mass and mixing parameter of the dark photon. In particular, we find that for dark photon mass m(sub gamma') in the 5-20 MeV range arguments based on supernova 1987A observations lead to a bound on epsilon which is about 300 times stronger than the presently existing bounds based on energy loss arguments.

Supernova bounds on the dark photon using its elec↗

Design Overview of the DM Radio Pathfinder Experiment

We introduce the DM Radio, a dual search for axion and hidden photon dark matter using a tunable superconducting lumped-element resonator. We discuss the prototype DM Radio Pathfinder experiment, which will probe hidden photons in the 500 peV (100 kHz)-50 neV (10 MHz) mass range. We detail the design of the various components: the LC resonant detector, the resonant frequency tuning procedure, the differential SQUID readout circuit, the shielding, and the cryogenic mounting structure. We present the current status of the pathfinder experiment and illustrate it's potential science reach in the context of the larger experimental program.

axion↗

Galactic origin of relativistic bosons and XENON1T excess

We entertain the exotic possibility that dark matter (DM) decays or annihilations taking place in our galaxy may produce a flux of relativistic very weakly-coupled bosons, axions or dark photons. We show that there exist several upper bounds for this flux on Earth assuming generic minimal requirements for DM, such as a lifetime longer than the age of the Universe or an annihilation rate that leaves unaffected the background evolution during matter domination. These bounds do not depend on the identity or the couplings of the bosons. We then show that this new flux cannot be large enough to explain the recent XENON1T excess, while assuming that the bosons’ couplings to the Standard Model are consistent with all current experimental and observational constraints. We also discuss a possible caveat to these bounds and a route to explain the excess.

Jatan Buch↗

Fermi LAT Search for Dark Matter in Gamma-Ray Lines and the Inclusive Photon Spectrum

Dark matter particle annihilation or decay can produce monochromatic gamma-ray lines and contribute to the diffuse gamma-ray background. Flux upper limits are presented for gamma-ray spectral lines from 7 to 200 GeV and for the diffuse gamma-ray background from 4.8 GeV to 264 GeV obtained from two years of Fermi Large Area Telescope data integrated over most of the sky. We give cross section upper limits and decay lifetime lower limits for dark matter models that produce gamma-ray lines or contribute to the diffuse spectrum, including models proposed as explanations of the PAMELA and Fermi cosmic-ray data.

Ackermann, M.↗

Rate for annihilation of galactic dark matter into two photons

A calculation of the cross section for neutralino-neutralino annihilation into two photons is performed and applied to dark matter in the galactic halo to find the counting rate in a large gamma ray detector such as EGRET (Energetic Gamma Ray Experiment Telescope) or ASTROGAM. Combining constraints from particle accelerators with the requirement that the neutralinos make up the dark matter, it is found that rates of over a few dozen events per year are unlikely. The assumptions that go into these conclusions are listed. Other particle dark matter candidates which could give larger and perhaps observable signals are suggested.

Giudice, Gian F.↗

Secluded WIMPs, Dark QED with Massive Photons, and the Galactic Center Gamma-Ray Excess

We discuss a particular secluded WIMP dark matter model consisting of neutral fermions as the dark matter candidate and a Proca-Wentzel (PW) field as a mediator. In the model that we consider here, dark matter WIMPs interact with standard model (SM) particles only through the PW field of approximately MeV-multi-GeV mass particles. The interactions occur via a U(1)' mediator, V'(sub mu), which couples to the SM by kinetic mixing with U(1) hypercharge bosons, B'(sub mu). One important difference between our model and other such models in the literature is the absence of an extra singlet scalar, so that the parameter with dimension of mass M(sup 2, sub V) is not related to a spontaneous symmetry breaking. This QED based model is also renormalizable. The mass scale of the mediator and the absence of the singlet scalar can lead to interesting astrophysical signatures. The dominant annihilation channels are different from those usually considered in previous work. We show that the GeV energy gamma-ray excess in the galactic center region, as derived from Fermi-LAT Gamma-ray Space Telescope data, can be attributed to such secluded dark matter WIMPs, given parameters of the model that are consistent with both the cosmological dark matter density and the upper limits on WIMP spin-independent elastic scattering. Secluded WIMP models are also consistent with suggested upper limits on a DM contribution to the cosmic-ray antiproton flux.

Gamma-Rays↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon counting detectors for free space optical communication. NASA GSFC is testing the performance of three novel photon counting detectors 1) a 2x8 mercury cadmium telluride avalanche array made by DRS Inc. 2) a commercial 2880 silicon avalanche photodiode array and 3) a prototype resonant cavity silicon avalanche photodiode array. We will present and compare dark count, photon detection efficiency, wavelength response and communication performance data for these detectors. We discuss system wavelength trades and architectures for optimizing overall communication link sensitivity, data rate and cost performance. The HgCdTe APD array has photon detection efficiencies of greater than 50 were routinely demonstrated across 5 arrays, with one array reaching a maximum PDE of 70. High resolution pixel-surface spot scans were performed and the junction diameters of the diodes were measured. The junction diameter was decreased from 31 m to 25 m resulting in a 2x increase in e-APD gain from 470 on the 2010 array to 1100 on the array delivered to NASA GSFC. Mean single photon SNRs of over 12 were demonstrated at excess noise factors of 1.2-1.3.The commercial silicon APD array has a fast output with rise times of 300ps and pulse widths of 600ps. Received and filtered signals from the entire array are multiplexed onto this single fast output. The prototype resonant cavity silicon APD array is being developed for use at 1 micron wavelength.

Photons↗

Temperature and photoperiod responses of soybean embryos cultured in vitro

Temperature and photoperiod each have direct effects on growth rate of excised embryos of soybean (Glycine max (L.) Merrill). To determine if the effects of photoperiod are altered by temperature, embryos of 'Ransom II' were cultured in vitro at 18, 24, and 30 degrees C under photoperiod durations of 12 and 18 h at an irradiance of 9 W m-2 (700 to 850 nm) and a photosynthetic photon flux density of 58 micromoles m-2 s-1 (400 to 700 nm). Accumulation rates of fresh and dry weight were greater under 18-h than 12-h photoperiods over the entire range of temperature. Water content of the culture embryos was not affected by photoperiod but was greater at 18 and 30 than 24 degrees C. The accumulation rate of dry weight increased from 18 to 26 but declined at 30 degrees C.

NASA Program CELSS↗

SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

Yan, Feng↗

On the observability of the gamma-ray line flux from dark matter annihilation

The limits on the possible cosmic gamma-ray line flux from the two-photon annihilation of dark matter in the Galaxy are discussed. These limits are derived using both particle physics and cosmological constraints on dark matter candidates which arise in supersymmetric extensions of the standard model of particle physics. Results are given in terms of allowed and prescribed areas in the flux-energy plane. Then these bounds are used to consider the observability of the line flux above continuum background fluxes using future high-resolution gamma-ray telescopes.

Rudaz, S.↗

The faint limit of the Hubble Space Telescope faint object spectrograph and rejection of the cosmic-ray background

The faintest object which can be observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) is set by the detector cosmic-ray background and not by object flux. We use data from Beaver and Lyons to show that 48% of the background counts are from cosmic rays which each generate a near instantaneous burst of two or more counts. Setting the FOS threshold parameter REJLIM = 1, which rejects all frames with more than one count increases the ratio of signal-to-dark counts (S/D) by a factor of 1.94, regardless of the frame time or the object signal, because half of the dark counts which arrive in single counts (from either cosmic-ray bursts or thermal dark current photoemission) are rejected at the same rate as the object signal. But the signal-to-noise ratio (SNR proportional to S/square root of S + D) increases by at most a factor of 1.35, and for realistic parameters and taking into account dead time, we expect a gain in SNR of only 1.18. If a diode has failed and now emits noise, no data at all will be recorded. The chance of this occurring is approximately = 10% , and for this reason we do not recommend the use of REJLIM. The two-point correlation function of dark counts per pixel has strong peaks every four pixels, caused by the action of quarter-stepping on the counts from large bursts. The counts from such bursts spread over at least 80-100 diodes, and we show that such bursts can be rejected during data reduction if the data are recorded in RAPID mode with individual exposures of about 35 seconds. The SNR of the spectrum can also be improved by weighting each exposure by its SNR (a function ofthe mean dark count rate at that time), since dark varies by a factor of 2 around an orbit. These two procedures together increase the SNR by a factor of 1.1.3 (a 28% gain in exposure time) in regions of a spectrum where the object is much fainter than the background. We find that the Ly-alpha and O I sky emission lines give at most 4 (counts/array/s/sq arcsec), and typically half this number. With a small frame time and a small entrance aperture, these counts cause REJLIM = 1 to reject only a few percent of the data. We discuss only the HST FOS blue side detector, but the same ideas apply to any photon counter which records bursts of noise, and the calculations resemble those for the loss of signal due to coincidences in photon counters. In the ideal photon counter the dark counts are readily distinguished from photons. One way to do this is to add detectors which records only dark current, so that every cosmic ray produces more than one count and the instrument can be operated in an anti-coincidence mode.

Tytler, David↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

Hunting Super-heavy Dark Matter with Ultra-high Energy Photons

At any epoch, particle physics must be open to completely unexpected discoveries, and that is reason enoughto extend the reach of searches for ultra-high energy (UHE) photons. The observation of a population ofphotons with energies𝐸 ≳100 EeVwould for example imply the existence of either a completely new physicalphenomena, or particle acceleration mechanisms heretofore never seen or imagined. But as we outline in thisLetter of Interest, there are also good arguments for super-heavy dark matter (SHDM) in a parameter rangesuch that it could be discovered via its decays to, in particular, UHE photons. Only ultra-high energy cosmic rayobservatories have capabilities to detect UHE photons. We first investigate how current and future observationscan probe and constrain SHDM models in important directions, and then outline some of the scenarios thatmotivate such searches. We also discuss connections between constraints on SHDM and on the parametervalues of cosmological models

Luis A Anchordoqui↗

Gas Exchange, Transpiration and Yield of Sweetpotato Grown in a Controlled Environment

Sweetpotato was grown to harvest maturity within NASA Johnson Space Center's Variable Pressure Growth Chamber (VPGC) to characterize crop performance for potential use in advanced life support systems as a contributor to food production, air revitalization and resource recovery. Stem cuttings of breeding clone "TU-82-155" were grown hydroponically at a density of 17 plants m(sup -2) using a modified pressure-plate growing system (Patent No. 4860-490, Tuskegee University). Lighting was provided by HPS lamps at a photoperiod of 12h light: 12h dark. The photosynthetic photon flux was maintained at 500, 750 and 1000 micro mol m(sup -2) s(sub -1) during days 1-15, 16-28, 29-119, respectively. Canopy temperatures were maintained at 28 C: light: 22 C:dark. During the light period, relative humidity and carbon dioxide were maintained at 70% and 1200 micro liters l(sup -1), respectively. Nutrient solution was manually adjusted 2 to 4 times per week by addition of 10X concentrated modified half-strength Hoagland nutrient salts and NaOH to return the electrical conductivity and pH to 1.2 mS cm(sup -1) and 6.0, respectively. At 17 weeks (119 days) from transplanting, a total of 56.5 kilograms fresh mass of storage roots (84.1% moisture) were harvested from the 11.2 m(sup 2) chamber, resulting in a yield 5.0 kilograms m(sup -2). Harvest index, based on fresh mass, was 38.6%. Rates of net photosynthesis, dark respiration, transpiration, and ethylene production will be reported.

Barta, Daniel J.↗

Improved Si:As BIBIB (Back-Illuminated Blocked-Impurity-Band) hybrid arrays

Results of a program to increase the short wavelength (less than 10 microns) detective quantum efficiency, eta/beta, of Si:As Impurity Band Conduction arrays are presented. The arrays are epitaxially grown Back-Illuminated Blocked (BIB) Impurity-Band (BIBIB) 10x50 detectors bonded to switched-FET multiplexers. It is shown that the 4.7 microns detective quantum efficiency increases proportionately with the thickness of the infrared active layer. A BIB array with a thick active layer, designed for low dark current, exhibits eta/beta = 7 to 9 percent at 4.7 microns for applied bias voltages between 3 and 5 V. The product of quantum efficiency and photoelectric gain, etaG, increases from 0.3 to 2.5 as the voltage increases from 3 to 5 V. Over this voltage range, the dark current increases from 8 to 120 e(-)s(-1) at a device temperature of 4.2 K and is under 70 e(-)s(-1) for all voltages at 2 K. Because of device gain, the effective dark current (equivalent photon rate) is less than 3 e(-)s(-1) under all operating conditions. The effective read noise (equivalent photon noise) is found to be less than 12 electrons under all operating conditions and for integration times between 0.05 and 100 seconds.

Herter, T.↗

Decaying neutrinos in galaxy clusters

The DM profile in clusters of galaxies was studied and simulated using the Harrison-Zel'dovich spectrum of density fluctuations, and an amplitude previously derived from numerical simulations and in agreement with microwave background fluctuations. Neutrino DM densities, with this amplitude normalization cluster, are comparable to observed cluster DM values. It was concluded that given this normalization, the cluster DM should be al least largely composed of neutrinos. The constraint of Davidson et al., who argued that the failure to detect uv photons from the dark matter (DM) in cluster A665 excludes the decaying neutrino hypothesis, could be somewhat weakened by the presence of baryonic DM; but it cannot be eliminated given our assumptions.

Melott, Adrian L.↗