Search NASA⌕ Search

SEARCH · Search NASA

Results for “data acquisition systems (DAQs)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Testing Rod Seal Leakage of a 700 HP Reciprocating Compressor

Methane emissions from reciprocating compressors in the U.S. natural gas industry account for over 72.4 Bcf per year according to a 2006 statement by the United States Environmental Protection Agency. Methane also has a global warming potential 50 times greater than carbon monoxide. Reciprocating compressors are the machinery type with the highest contribution to methane emissions at natural gas transmissions stations. The largest contributing factor comes from the sealing components in the packing components around the piston rod. SwRI, therefore, designed and setup a test loop to perform baseline packing leakage measurements on a four stage 700 HP JGT/4 compressor. The goal was to improve upon current packing leakage models and to compare new seals vs. used seals. The test loop design is described including the limits of operation. The Data Acquisition System (DAQ), including data measurements, is also fully described. The project shows the results of the commissioning process that verified the operation of all the components. Once the loop was commissioned, SwRI performed baseline packing leakage for multiple pressure ratios on each of the four stages of the compressor. The data was collected to develop an analytical model of the packing leakage. Finally, similar testing was performed after replacing the typical rod seal packing with used packing. The used packing leakage was compared to the baseline packing leakage.

03 NATURAL GAS↗

A Scalable Online Monitoring System Based on Elasticsearch for Distributed Data Acquisition in Cms

The part of the CMS Data Acquisition (DAQ) system responsible for data readout and event building is a complex network of interdependent distributed applications. To ensure successful data taking, these programs have to be constantly monitored in order to facilitate the timeliness of necessary corrections in case of any deviation from specified behaviour. A large number of diverse monitoring data samples are periodically collected from multiple sources across the network. Monitoring data are kept in memory for online operations and optionally stored on disk for post-mortem analysis. We present a generic, reusable solution based on an open source NoSQL database, Elasticsearch, which is fully compatible and non-intrusive with respect to the existing system. The motivation is to benefit from an off the-shelf software to facilitate the development, maintenance and support efforts. Elasticsearch provides failover and data redundancy capabilities as well as a programming language independent JSON-over-HTTP interface. The possibility of horizontal scaling matches the requirements of a DAQ monitoring system. The data load from all sources is balanced by redistribution over an Elasticsearch cluster that can be hosted on a computer cloud. In order to achieve the necessary robustness and to validate the scalability of the approach the above monitoring solution currently runs in parallel with an existing in-house developed DAQ monitoring system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Requirements Document for a Replacement Data Acquisition System

A flight vehicle is in the developmental stages. While in development flight testing is required by both the manufacturer and customer to rate design performance. The performance of the vehicle must fulfill the agreed upon requirements. Testing of a flight vehicle during operation requires various sensors in order to record and monitor performance for evaluation. A Data Acquisition System (DAQ) is needed in order to control and capture data from various sensors placed throughout the vehicle during flight. This DAQ will receive the analog data from the suite of sensors and convert them to a digital signal that can be transmitted to a recording station where the data will later be analyzed by test experts. Some of the key features to be included in the DAQ will be a self-check operation to verify the health of all sensors including the DAQ. The DAQ will also have the capability to store sensor calibration data files loaded during assembly and transmit those files to the recording station during flight. Breakthroughs in new technologies has allowed for higher resolution recording systems and faster sampling rates. Improved sensor data using a new Data Acquisition System (DAQ) can provide important answers to questions discovered during the last few flight tests. These questions arose when the flight system expressed unexpected behaviors. Having the capability of the new DAQ in flight tests would allow for more high-fidelity data to be captured from the system during flight tests and ultimately reducing the number of required flight test. Reducing the number of flight tests also reduce developmental cost and schedule.

42 ENGINEERING↗

Region of Interest Filter in DUNE DAQ

The Deep Underground Neutrino Experiment (DUNE) is the next generation neutrino experiment currently under construction. It consists of a broadband neutrino beam at Fermilab, a high precision near detector, and the largest liquid argon time projection chamber far detector ever designed at the Sanford Underground Research Facility (SURF). The Region of Interest (ROI) filter is designed for DUNE’s online Data Acquisition (DAQ) system to address data rate constraints and enable low energy physics in the <10 MeV range. The filter employs zero suppression on the detector signal, and by tuning the readout window and threshold the data rates can be reduced by >90%. Performance of the ROI is analyzed in LArsoft on MARLEY generated low energy MC events propagated through the detector simulation. Notably, the optimized ROI filter enables a lower trigger threshold for readout at ~5-10 MeV, allowing DUNE to explore low-energy physics, specifically focusing on solar boron 8 neutrinos which are relevant in this energy range. This advancement enhances DUNE's scientific capabilities, opening avenues for detailed analyses of previously inaccessible low-energy neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron multiplicity ,easurements With 3 He alternative: Straw neutron detectors

Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10 B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions of neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3 He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10 B (in the form of enriched boron carbide: 10 B 4 C) for neutron detection instead of 3 He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

The DAQ and control system for the CMS Phase-1 pixel detector upgrade

In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Throughput Data Processing at FRIB Using ESnet

Real-time or nearly real-time (nearline) data processing methods are critical tools as detector technologies and data acquisition (DAQ) systems allow for higher data rates and volumes. The introduction of the energy sciences network (ESnet), a U.S. Department of Energy (DOE) supported high-speed network for scientific research, creates opportunities to leverage the computing power of DOE facilities like the National Energy Research Scientific Computing Center (NERSC). As a first step toward realizing a DOE Office of Science Integrated Research Infrastructure (IRI) pattern, an automated workflow was developed to remotely process data obtained from a nuclear physics experiment at the Facility for Rare Isotope Beams (FRIB) at NERSC with data transferred between FRIB and NERSC over ESnet. The workflow demonstrated the ability to process one week’s worth of experimental data in approximately 90 min and was used successfully for nearline analysis during a recently completed FRIB experiment. Here, a summary of the workflow development and results of recent demonstrations will be presented.

Data processing↗

A triggerless digital data acquisition system for nuclear decay experiments

In nuclear decay experiments an important goal of the Data Acquisition (DAQ) system is to allow the reconstruction of time correlations between signals registered in different detectors. Classically DAQ systems are based in a trigger that starts the event acquisition, and all data related with the event of that trigger are collected as one compact structure. New technologies and electronics developments offer new possibilities to nuclear experiments with the use of sampling ADC-s. This type of ADC-s is able to provide the pulse shape, height and a time stamp of the signal. This new feature (time stamp) allows new systems to run without an event trigger. Later, the event can be reconstructed using the time stamp information. In this work we present a new DAQ developed for {beta}-delayed neutron emission experiments. Due to the long moderation time of neutrons, we opted for a self-trigger DAQ based on commercial digitizers. With this DAQ a negligible acquisition dead time was achieved while keeping a maximum of event information and flexibility in time correlations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPLENDAQ: A Detector-Agnostic Data Acquisition System for Small-Scale Physics Experiments

Many scientific applications from rare-event searches to condensed matter system characterization to high-rate nuclear experiments require time-domain triggering on a raw stream of data, where the triggering is generally threshold-based or randomly acquired. When carrying out detector R &D, there is a need for a general data acquisition (DAQ) system to quickly and efficiently process such data. In the SPLENDOR collaboration, we are developing the Python-based SPLENDAQ package for this exact purpose—it offers two main features for offline analysis of continuous data: a threshold triggering algorithm based on the time-domain optimal filter formalism and an algorithm for randomly choosing nonoverlapping segments for noise measurements. Further, combined with the commercially available Moku platform, developed by Liquid Instruments, we have a full pipeline of event building off raw data with minimal setup. Here, we review the underlying principles of this detector-agnostic DAQ package and give concrete examples of its utility in various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equivalent time sampling

Equivalent time sampling of a signal may be performed by using an embedded system to create trigger pulses for data acquisition (DAQ) system to record the response. The trigger pulse to the DAQ system may be propagated through digital delay chips controlled by the embedded system. The exemplary embodiments allow the DAQ system to be triggered from locally generated trigger pulses or from external or remote sources.

47 OTHER INSTRUMENTATION↗

Advancing $otsdaq$ for Optimized Data Acquisition

High-energy physics (HEP) experiments demand data acquisition (DAQ) systems capable of orchestrating complex detector operations, high data throughput, and responsive, real-time feedback. Traditional systems often have steep learning curves, making onboarding difficult for new users. The Off-The-Shelf Data Acquisition $otsdaq$ framework was developed to address these issues by providing a modular and flexible interface that is easier to operate while remaining customizable enough for experimental setups. As the upcoming Mu2e experiment prepares for deployment, improving stability, usability, and performance has become increasingly critical. Our work enhances $otsdaq$ with features that streamline visualization, correct data metrics, improve debugging workflows, and stabilize the user interface.

Mohammed, Ali (ORCID:0009000860386626)↗

Advancing \textit{otsdaq}: Enhancements for Usability, Accuracy, and Robustness

High-energy physics (HEP) experiments require data acquisition (DAQ) systems that can orchestrate complex detector operations, high data throughput, and responsive, real-time feedback to operators. Traditional DAQ stacks, which are often bespoke, command-line driven and highly specific, impose large learning curves on users. The Off-The-Shelf Data Acquisition (\textit{otsdaq}) framework was created to address these issues by offering a highly customizable and scalable browser-based ’desktop’ environment, in which experiment-specific control and monitoring applications can be easily deployed and integrated. Although the initial development of the \textit{otsdaq} software was aimed at the Fermilab Test Beam Facility, \textit{otsdaq} is now being leveraged for broader deployment, including the upcoming Mu2e experiment, where real-time monitoring of field-programmable gate array (FPGA)-based Data Transfer Controllers (DTCs), Clock and Fanout (CFO) boards, and several other subsystems are critical. We contribute a set of targeted improvements to \textit{otsdaq}: bitmap visualization functionality for configured data, improved and corrected delta-based DTC throughput metrics, version control (VC)-backed source navigation for console messages, custom navigation hooks to eliminate disruptive user interface glitches, and copy-to-clipboard support for macro execution history. These changes improve usability, reduce debugging time, and increase accuracy in performance data as Mu2e moves toward commissioning.

Mohammed, A. [Unlisted, US]↗

Evaluation of a high-performance storage buffer with 3D XPoint devices for the DUNE data acquisition system

The DUNE detector is a neutrino physics experiment that is expected to take data starting from 2028. The data acquisition (DAQ) system of the experiment is designed to sustain several TB/s of incoming data which will be temporarily buffered while being processed by a software based data selection system. In DUNE, some rare physics processes (e.g. Supernovae Burst events) require storing the full complement of data produced over 1-2 minute window. These are recognised by the data selection system which fires a specific trigger decision. Upon reception of this decision data are moved from the temporary buffers to local, high performance, persistent storage devices. In this paper we characterize the performance of novel 3DXPoint SSD devices under different workloads suitable for high-performance storage applications. We then illustrate how such devices may be applied to the DUNE use-case: to store, upon a specific signal, 100 seconds of incoming data at 1.5 TB/s distributed among 150 identical units each operating at approximately 10GB/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition system for the Baikal-GVD neutrino telescope

The objective of the Baikal-GVD project is the construction of a km{sup 3}-scale neutrino telescope in Lake Baikal. The Gigaton Volume Detector consists of a large three-dimensional array of photo-multiplier tubes. The first GVD-cluster has been deployed and commissioned in April 2015. The data acquisition system (DAQ) of the detector takes care of the digitization of the photo-multiplier tube signals, data transmission, filtering and storage. The design and the implementation of the data acquisition system are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Stability R&D for the APS MBA Upgrade

Beam diagnostics required for the APS Multi-bend acromat (MBA) are driven by ambitious beam stability requirements. The major AC stability challenge is to correct rms beam motion to 10% the rms beam size at the insertion device source points from0.01 to 1000 Hz. The vertical plane represents the biggest challenge forAC stability, which is required to be 400 nm rms for a 4-micron vertical beam size. In addition to AC stability, long-term drift over a period of seven days is required to be 1 micron or less. Major diagnostics R&D components include improved rf beam position processing using commercially available FPGA-based BPM processors, new X-ray beam position monitors based on hard X-ray fluorescence from copper and Compton scattering off diamond, mechanical motion sensing to detect and correct long-term vacuum chamber drift, a new feedback system featuring a tenfold increase in sampling rate, and a several-fold increase in the number of fast correctors and BPMs in the feedback algorithm. Feedback system development represents a major effort, and we are pursuing development of a novel algorithm that integrates orbit correction for both slow and fast correctors down to DC simultaneously. Finally, a new data acquisition system (DAQ) is being developed to simultaneously acquire streaming data from all diagnostics as well as the feedback processors for commissioning and fault diagnosis. Results of studies and the design effort are reported.

APS MBA Upgrade↗

Event triggering in the IceCube data acquisition system

In order to detect cosmic ray air showers and neutrinos, the software data acquisition (DAQ) system of the IceCube Neutrino Observatory forms triggers on patterns of Cherenkov light deposition in the detector based on temporal and/or spatial coincidences. Here we describe the algorithms used for triggering, as well as the fast merging algorithm used to combine the time-ordered hit streams from the optical modules. We also present recently implemented and planned modifications of the DAQ that take advantage of our newly upgraded multi-core computer systems at the South Pole.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a High Throughput PCIe Card for DAQ System in the ATLAS and DUNE Experiments

In the Run 3 upgrade of ATLAS experiment, the FELIX (Front-End LInk eXchange) system has been prepared as the interface between front-end electronics and common Data Acquisition (DAQ) systems. Based on a PCIe card hosted in commodity server, FELIX's flexibilty makes it has also been adopted by other experiments, such as the Single-Phase ProtoDUNE (Prototype for the Deep Underground Neutrino Experiment), sPHENIX and CBM experiments. The same PCIe based architecture is proposed for use in the ATLAS HL-LHC (High Luminosity Large Hadron Collider) upgrade and the DUNE experiment. To this end, the next generation of FELIX I/O card FLX-801 has been developed. It supports 25+ Gbps high speed fiber optical links and 16-lane Gen4 PCIe interface. There is an on-card DDR4 module to buffer event data for DUNE experiment. This paper reports on the test results for the demonstrator of this next generation card, with which main functions have been successfully evaluated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗