Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)

Stability Considerations for Virtual Capacitor Control in Constant Power DC Loads

In a DC grid, constant power loads (CPLs) necessitate a large bus capacitor to prevent negative impedance instability. Some of the capacitance can be realized virtually through CPL control to reduce the bus capacitor size. Here, this paper analytically studies system stability with virtual capacitor control. We demonstrate that the effectiveness of virtual capacitor control is highly sensitive to the implementation of the derivative action required to emulate the capacitor. For the first time, we theoretically demonstrate that a virtual capacitor can stabilize the system without any physical bus capacitor, provided that a set of analytically derived conditions are met. However, this stabilization is not achievable in practice due to the influence of non-idealities. In an example system requiring a $14$ mF capacitor to stably support the CPL, we show that stability can be achieved through virtual capacitor control, using only a 2 mF physical capacitor to account for the switching ripple non-idealities. Hardware-in-the-loop tests verify the analysis.

24 POWER TRANSMISSION AND DISTRIBUTION

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter

A Guide to Current Limiting and Stability with Grid-Forming Inverters

The electric power grid is changing. For many decades, the synchronous generator - an electromechanical device invented in 1887 - has been the workhorse and backbone of power grids across the globe. Our entire infrastructure is built around it. But times change, and so does the power grid. Since the early 21st century, we have seen a gradual shift in modern power grids away from synchronous generators to ones dominated by power electronic inverter-based resources (IBRs). Sources such as photovoltaics, wind turbines, battery storage, fuel cells, and other technologies like high-voltage DC transmission interconnections all rely on an inverter to connect and interface with the grid. They are increasingly being installed on the grid to augment, or even replace, traditional energy sources. This change is a fundamental shift that brings tremendous technical challenges and questions: Can a power grid remain stable with many more inverter-based resources? How do we avoid more blackouts on the grid? How do we keep the grid secure and resilient during disturbances? After all, power electronic inverters are nothing like the big, rotating, iron-and-copper machines that the grid heavily relies on. Many of these questions can be answered by using grid-forming (GFM) inverters, yet many research challenges remain. This document explores GFM inverters and how they can help stabilize the future grid, especially during disturbances and contingencies. It summarizes a two-year research and development fellowship program at NREL. We point interested readers to more detailed works developed during the project along the way. Let's dive in

24 POWER TRANSMISSION AND DISTRIBUTION

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]

Scalability and Effectiveness of Smart Charge Management

The rise in electric vehicle (EV) adoption presents growing challenges for power grids, particularly from simultaneous residential charging, which can cause voltage fluctuations and increase feeder peak loads. Baltimore Gas and Electric (BGE), with support from the U.S. Department of Energy, initiated a pilot program to evaluate managed residential EV charging through Smart Charge Management (SCM). This study analyzes real-world charging behavior data from the pilot and feeder-level base loads from BGE to simulate residential charging scenarios through 2035 across the Washington, DC–Baltimore region. Grid impacts under unmanaged charging are compared to three SCM strategies: TOU-immediate, TOU-distributed, and Load Balancing. Results show that the magnitude of peak reduction is highly feeder-dependent. Some feeders achieve reductions of more than 40% at high enrollment levels, while others show improvements closer to 10–15%. This heterogeneity reflects differences in baseline feeder load shapes, EV penetration, and plug-in behavior across customers. Results also highlight trade-offs between shifting load away from peak periods and minimizing secondary demand peaks, offering practical insights for future utility program design.

Electric vehicle

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION

Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids

Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. Finally, when addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.

Fan, Lingling [Univ. of South Florida, Tampa, FL (