Search NASA⌕ Search

SEARCH · Search NASA

Results for “dc pro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data Center Fact Sheet: DC Pro Software Tool Suite

This fact sheet describes how DOE's Data Center Energy Profiler (DC Pro) Software Tool Suite and other resources can help U.S. companies identify ways to improve the efficiency of their data centers.

97 MATHEMATICS AND COMPUTING↗

DC Pro Software Tool Suite

This fact sheet describes how DOE's Data Center Energy Profiler (DC Pro) Software Tool Suite and other resources can help U.S. companies identify ways to improve the efficiency of their data centers.

Centers↗

Data Center IT Equipment Energy Assessment Tools: Current State of Commercial Tools, Proposal for a Future Set of Assessment Tools

This research project, which was conducted during the Summer and Fall of 2011, investigated some commercially available assessment tools with a focus on IT equipment to see if such tools could round out the DC Pro tool suite. In this research, the assessment capabilities of the various tools were compiled to help make “non-biased” information available to the public. This research should not be considered to be exhaustive on all existing vendor tools although a number of vendors were contacted. Large IT equipment OEM’s like IBM and Dell provide their proprietary internal automated software which does not work on any other IT equipment. However, found two companies with products that showed promise in performing automated assessments for IT equipment from different OEM vendors. This report documents the research and provides a list of software products reviewed, contacts and websites, product details, discussions with specific companies, a set of recommendations, and next steps. As a result of this research, a simple 3-level approach to an IT assessment tool is proposed along with an example of an assessment using a simple IT equipment data collection tool (Level 1, spreadsheet). The tool has been reviewed with the Green Grid and LBNL staff. The initial feedback has been positive although further refinement to the tool will be necessary. Proposed next steps include a field trial of at least two vendors’ software in two different data centers with an objective to prove the concept, ascertain the extent of energy and computational assessment, ease of installation and opportunities for continuous improvement. Based on the discussions, field trials (or case studies) are proposed with two vendors – JouleX (expected to be completed in 2012) and Sentilla.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deferiprone attenuates inflammation and myocardial fibrosis in diabetic cardiomyopathy rats

We attempted to investigate the therapeutic effects of deferiprone on DC rats and explore the underlying mechanism. Total 24 6-week-old male Wistar rats (weighing from 180 g to 220 g) were subjected to DC model construction and then randomly divided to three groups (8 rats per group): DC group, DC + 50 mg, and DC + 100 mg deferiprone treatment group. The 8 normal rats were considered as controls. After deferiprone treatment for 20 weeks, the blood samples were collected for the biochemical parameters test, including fasting glucose, HOMA-IR (homeostasis model assessment of the insulin resistance), serum iron, ferritin and transferrin saturation (TS). The oxidative stress was assessed by detecting the level of malondialdehyde (MDA) and superoxide dismutase (SOD). Histopathologic changes were determined by Masson's trichrome staining and electron microscopy imaging. The expression levels of NF-κB (nuclear factor kappa B), COX2 (cytochrome c oxidase), tenascin C, collagen IV were measured by RT-PCR and western blotting. The expression of nitrotyrosine and MCP-1 (monocyte chemotactic protein 1) were determined by immunohistochemistry. Deferiprone treatment reduced iron deposition and IR in DC rats except for blood glucose. After deferiprone treatment, MDA level was significantly decreased and SOD level was increased significantly. The level of NF-κB, cyclooxygenase-2, tenascin C, collagen IV MCP-1 and nitrotyrosine were significantly reduced. There was no significant difference in the effect of deferiprone at 50 and 100 mg doses. Deferiprone showed therapeutic effects on DC by regulating the pro-inflammatory and pro-fibrotic factors. - Highlights: • The expression of serum iron, ferritin and TS were elevated in DC rats. • Oxidative stress related MDA and SOD were upregulated in DC rats. • NF-κB, COX2, tenascin C, collagen IV were accumulated in DC rats. • All the changes were reversed by deferiprone treatment.

60 APPLIED LIFE SCIENCES↗

DC Fast Charging Infrastructure for Electrified Road Trips

To assess DC fast charging station network required for electrified road trips by 2030 in California, a new charging infrastructure simulation tool/model, EVI-Pro (Electric Vehicle Infrastructure Projection) RoadTrip, has been developed. In contrast to the existing EVI-Pro model that is primarily for short-distance travels, EVI-Pro RoadTrip is exclusively focused on road trips (long-distance travels, 100 or miles per day per vehicle). Also, the charging paradigm or strategy is different. EVI-Pro RoadTrip is built upon waypoint charging, in which vehicles are forced to stop to charge or replenish the on-board batteries, along the routes between origins and destinations. On the other hand, EVI-Pro is based on destination charging, in which charging is conducted when vehicles are parked in destinations (e.g., work, home). EVI-Pro RoadTrip takes coordinate-level origin and destination data for road trips (intra-state as well as domestic or international out-of-state) and estimates energy consumption and charging needs along the routes between origins and destinations on a minute-by-minute resolution. Based on charging demands for electrified road trips across the state, the optimal locations of charging stations are determined accounting for preferred land use types (e.g., commercial areas) and station service area (e.g., 5 or less miles). Based on station-by-station charging load profiles, the required number of plugs/connectors is estimated for each station and entire state. By comparing hosting capacity of the electric grid (circuit-level) and the charging load output from EVI-Pro RoadTrip, capacity deficit is also evaluated.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Superconducting and magneto-transport properties of BiS{sub 2} based superconductor PrO{sub 1-x}F{sub x}BiS{sub 2} (x = 0 to 0.9)

We report superconducting properties of PrO{sub 1-x}F{sub x}BiS{sub 2} compounds, synthesized by the vacuum encapsulation technique. The synthesized PrO{sub 1-x}F{sub x}BiS{sub 2} (x = 0.1, 0.3, 0.5, 0.7, and 0.9) samples are crystallized in a tetragonal P4/nmm space group. Both transport and DC magnetic susceptibility measurements showed bulk superconductivity below 4 K. The maximum T{sub c} is obtained for x = 0.7 sample. Under applied magnetic field, both T{sub c}{sup onset} and T{sub c} (ρ = 0) decrease to lower temperatures. We estimated highest upper critical field [H{sub c2}(0)] for PrO{sub 0.3}F{sub 0.7}BiS{sub 2} sample to be above 4 T (Tesla). The thermally activated flux flow activation energy (U{sub 0}) is estimated 54.63 meV in 0.05 T field for PrO{sub 0.3}F{sub 0.7}BiS{sub 2} sample. Hall measurement results showed that electron charge carriers are the dominating ones in these compounds. Thermoelectric effects (Thermal conductivity and Seebeck coefficient) data suggest strong electron-electron correlations in this material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-dimensional modelling of electrostatic force distance curve over dielectric surface: Influence of tip geometry and correlation with experiment

Electric Force-Distance Curves (EFDC) is one of the ways whereby electrical charges trapped at the surface of dielectric materials can be probed. To reach a quantitative analysis of stored charge quantities, measurements using an Atomic Force Microscope (AFM) must go with an appropriate simulation of electrostatic forces at play in the method. This is the objective of this work, where simulation results for the electrostatic force between an AFM sensor and the dielectric surface are presented for different bias voltages on the tip. The aim is to analyse force-distance curves modification induced by electrostatic charges. The sensor is composed by a cantilever supporting a pyramidal tip terminated by a spherical apex. The contribution to force from cantilever is neglected here. A model of force curve has been developed using the Finite Volume Method. The scheme is based on the Polynomial Reconstruction Operator—PRO-scheme. First results of the computation of electrostatic force for different tip–sample distances (from 0 to 600 nm) and for different DC voltages applied to the tip (6 to 20 V) are shown and compared with experimental data in order to validate our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗