Search NASA⌕ Search

SEARCH · Search NASA

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deconvolution of Stark broadened spectra for multi-point density measurements in a flow Z-pinch

Stark broadened emission spectra, once separated from other broadening effects, provide a convenient non-perturbing means of making plasma density measurements. A deconvolution technique has been developed to measure plasma densities in the ZaP flow Z-pinch experiment. The ZaP experiment uses sheared flow to mitigate MHD instabilities. The pinches exhibit Stark broadened emission spectra, which are captured at 20 locations using a multi-chord spectroscopic system. Spectra that are time- and chord-integrated are well approximated by a Voigt function. The proposed method simultaneously resolves plasma electron density and ion temperature by deconvolving the spectral Voigt profile into constituent functions: a Gaussian function associated with instrument effects and Doppler broadening by temperature; and a Lorentzian function associated with Stark broadening by electron density. The method uses analytic Fourier transforms of the constituent functions to fit the Voigt profile in the Fourier domain. The method is discussed and compared to a basic least-squares fit. The Fourier transform fitting routine requires fewer fitting parameters and shows promise in being less susceptible to instrumental noise and to contamination from neighboring spectral lines. The method is evaluated and tested using simulated lines and is applied to experimental data for the 229.69 nm C III line from multiple chords to determine plasma density and temperature across the diameter of the pinch. These measurements are used to gain a better understanding of Z-pinch equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Application of the Lucy–Richardson Deconvolution Procedure to High Resolution Photoemission Spectra

Angle-resolved photoemission has developed into one of the leading probes of the electronic structure and associated dynamics of condensed matter systems. As with any experimental technique the ability to resolve features in the spectra is ultimately limited by the resolution of the instrumentation used in the measurement. Previously developed for sharpening astronomical images, the Lucy-Richardson deconvolution technique proves to be a useful tool for improving the photoemission spectra obtained in modern hemispherical electron spectrometers where the photoelectron spectrum is displayed as a 2D image in energy and momentum space.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectral deconvolution without the deconvolution: Extracting temperature from x-ray Thomson scattering spectra without the source-and-instrument function

X-ray Thomson scattering (XRTS) probes the dynamic structure factor of the system, but the measured spectrum is broadened by the combined source-and-instrument function (SIF) of the setup. In order to extract properties such as temperature from an XRTS spectrum, the broadening by the SIF needs to be removed. Recent work [Dornheim et al. Nat. Commun. 13 , 7911 (2022)] has suggested that the SIF may be deconvolved using the two-sided Laplace transform. However, the extracted information can depend strongly on the shape of the input SIF, and the SIF is in practice challenging to measure accurately. Here, we propose an alternative approach: we demonstrate that considering ratios of Laplace-transformed XRTS spectra collected at different scattering angles is equivalent to performing the deconvolution, but without the need for explicit knowledge of the SIF. From these ratios, it is possible to directly extract the temperature from the scattering spectra, when the system is in thermal equilibrium. We find the method to be generally robust to spectral noise and physical differences between the spectrometers, and we explore situations in which the method breaks down. Furthermore, the fact that consistent temperatures can be extracted for systems in thermal equilibrium indicates that non-equilibrium effects could be identified by inconsistent temperatures of a few eV between the ratios of three or more scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deconvolution of octahedral Pt 3 Ni nanoparticle growth pathway from in situ characterizations

Understanding the growth pathway of faceted alloy nanoparticles at the atomic level is crucial to morphology control and property tuning. Yet, it remains a challenge due to complexity of the growth process and technical limits of modern characterization tools. We report a combinational use of multiple cutting-edge in situ techniques to study the growth process of octahedral Pt3Ni nanoparticles, which reveal the particle growth and facet formation mechanisms. Our studies confirm the formation of octahedral Pt 3 Ni initiates from Pt nuclei generation, which is followed by continuous Pt reduction that simultaneously catalyzes Ni reduction, resulting in mixed alloy formation with moderate elemental segregation. Furthermore, carbon monoxide molecules serve as a facet formation modulator and induce Ni segregation to the surface, which inhibits the (111) facet growth and causes the particle shape to evolve from a spherical cluster to an octahedron as the (001) facet continues to grow.

36 MATERIALS SCIENCE↗

Secondary Ion Mass Spectrometry Methodology for Isotopic Ratio Measurement of Micro‐Grains in Thin Sections: True Grain Size Estimation and Deconvolution of Inter‐Grain Size Gradients and Intra‐Grain Radial Gradients

In a thin section, grains that were approximately spherical in situ appear circular in cross section, and the distribution of apparent diameters frequently assumed to be their size distribution. Scanning ion imaging by secondary ion mass spectrometry (SIMS) is capable of providing precise (< 1‰) stable isotope ratio measurements of such grains, but, importantly, also registers their rate of evolution in apparent size as they are ablated by the primary beam. By assessing rates of radius change with depth, the described methodology enables the ‘true’ size of grains to be estimated, as well as the distance of the sectioned surface from the original grain centre. Transects in three dimensions are made possible, and this capability enables better identification (and thus separation) of both inter‐grain chemical signatures as a function of grain size, and intra‐grain radial trends. In this example, we highlight the specific application to pyrite (FeS 2 ) minerals, which are frequently analysed by SIMS to determine their inter‐grain and intra‐grain geochemical variations, particularly in their sulfur stable isotopic ratios (δ 34 S). Benefits of the new methodology over the Faraday cup ‘spot mode’ are described. Data correction algorithms and precision considerations are discussed.

Jones, Clive↗

SU-F-T-478: Effect of Deconvolution in Analysis of Mega Voltage Photon Beam Profiles

Purpose: To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers. Methods: 0.125cc Semi-Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in-plane and cross-plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateral and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied. Results: After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles. Conclusion: The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction

Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavenumber-frequency deconvolution of aeroacoustic microphone phased array data of arbitrary coherence

Deconvolution of aeroacoustic data acquired with microphone phased arrays is a computationally-challenging task for distributed sources with arbitrary coherence. A new technique for performing such deconvolution is proposed. This technique relies on analysis of the array data in the wavenumber-frequency domain, allowing for fast convolution and reduced storage requirements when compared to traditional coherent deconvolution. A positive semidefinite constraint for the iterative deconvolution procedure is implemented and shows improved behavior in terms of quantifiable convergence metrics when compared to a standalone covariance inequality constraint. A series of simulations validates the method's ability to resolve coherence and phase angle relationships between partially-coherent sources, as well as determines convergence criteria for deconvolution analysis. Simulations for point sources near the microphone phased array show potential for handling such data in the wavenumber-frequency domain. In particular, a physics-based integration boundary calculation is described, and can successfully isolate sources and track the appropriate integration bounds with and without the presence of flow. Magnitude and phase relationships between multiple sources are successfully extracted. Limitations of the deconvolution technique are determined from the simulations, particularly in the context of a simulated acoustic field in a closed test section wind tunnel with strong boundary layer contamination. A final application to a trailing edge noise experiment conducted in an open-jet wind tunnel matches best estimates of acoustic levels from traditional calculation methods and qualitatively assesses the coherence characteristics of the trailing edge noise source.

phased array↗

SU-C-9A-03: Simultaneous Deconvolution and Segmentation for PET Tumor Delineation Using a Variational Method

Purpose: To implement a new method that integrates deconvolution with segmentation under the variational framework for PET tumor delineation. Methods: Deconvolution and segmentation are both challenging problems in image processing. The partial volume effect (PVE) makes tumor boundaries in PET image blurred which affects the accuracy of tumor segmentation. Deconvolution aims to obtain a PVE-free image, which can help to improve the segmentation accuracy. Conversely, a correct localization of the object boundaries is helpful to estimate the blur kernel, and thus assist in the deconvolution. In this study, we proposed to solve the two problems simultaneously using a variational method so that they can benefit each other. The energy functional consists of a fidelity term and a regularization term, and the blur kernel was limited to be the isotropic Gaussian kernel. We minimized the energy functional by solving the associated Euler-Lagrange equations and taking the derivative with respect to the parameters of the kernel function. An alternate minimization method was used to iterate between segmentation, deconvolution and blur-kernel recovery. The performance of the proposed method was tested on clinic PET images of patients with non-Hodgkin's lymphoma, and compared with seven other segmentation methods using the dice similarity index (DSI) and volume error (VE). Results: Among all segmentation methods, the proposed one (DSI=0.81, VE=0.05) has the highest accuracy, followed by the active contours without edges (DSI=0.81, VE=0.25), while other methods including the Graph Cut and the Mumford-Shah (MS) method have lower accuracy. A visual inspection shows that the proposed method localizes the real tumor contour very well. Conclusion: The result showed that deconvolution and segmentation can contribute to each other. The proposed variational method solve the two problems simultaneously, and leads to a high performance for tumor segmentation in PET. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant Nos. 60971112 and 61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regularized deconvolution method for turbulent combustion modeling

The modeling of filtered chemical source terms in large-eddy simulation (LES) of turbulent reacting flows remains a challenge. Deconvolution methods are an attractive technique for representing these unclosed terms. With this technique, filtered scalars are reconstructed through deconvolution. The chemical source terms that are computed directly from the deconvolved scalars are filtered explicitly to represent the turbulence-chemistry interaction. However, the approximate deconvolution method (ADM), frequently employed for non-reacting flows, exhibits shortcomings for reacting scalars. This is because ADM does not ensure essential conservation and boundedness conditions. So to address this issue, we propose a regularized deconvolution method (RDM) based on an optimization procedure. We conduct a priori and a posteriori analyses to examine RDM as a closure in LES. These investigations are performed in the context of explicit filtering. By showing that RDM is accurate and stable with respect to both the filter width and time, we conclude that the new deconvolution method shows promise in application to combustion LES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing Top-Down Proteoform Identification: Deconvolution, PrSM Overlap, and PTM Detection

Generating top-down tandem mass spectra (MS/MS) for complex mixtures of proteoforms has become possible through improvements in fractionation, on-line separation, dissociation, and mass analysis. The algorithms to match tandem mass spectra to sequences have undergone a parallel evolution, with both spectral alignment and peak matching being paired with diverse methods for scoring proteoform-spectral matches (PrSMs). This study assesses state-of-the-art algorithms for top-down identification through three distinct challenges. The first is identifying a large yield of PrSMs while controlling false discovery rate (FDR) in identifying thousands of proteoforms from complex cell lysates via four software workflows: ProSight Proteome Discoverer, TopPIC, Informed Proteomics, and pTop. The second is the deconvolution of data from both Thermo Orbitrap-class and Bruker maXis Q-TOF instruments to produce consistent precursor charge and mass determinations while generating fragment mass lists to optimize identification. The third attempts to detect diverse post-translational modifications (PTMs) in proteoforms from cow milk and human ovarian tissue. The data demonstrate that existing software suites produce admirable sensitivity, in some cases identifying a third of collected tandem mass spectra with FDR controlled below 2%; the overlap in these PrSMs, however, illustrates real value in searching data with multiple search engines. Differences among identification workflows seem to result from each search algorithm incorporating its own deconvolution algorithm. By transmitting deconvolution data from multiple deconvolution routes (Thermo Xtract, Bruker Auto MSn, Mascot Distiller, TopFD, and FLASHDeconv) to the downstream TopPIC search algorithm, we were able to detect common causes of deconvolution disagreement. The detection of PTMs was very inconsistent among search algorithms, with some workflows suggesting as little as 1% of PrSMs from cow’s milk were singly-phosphorylated while other workflows found that 18% of PrSMs were singly-phosphorylated. Taken together, these results make a strong argument for top-down researchers to adopt a standard practice of analyzing each MS/MS experiment with at least two different search engines.

59 BASIC BIOLOGICAL SCIENCES↗

Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibration curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗