Search NASA⌕ Search

SEARCH · Search NASA

Results for “deep convective clouds”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impacts of Varying Concentrations of Cloud Condensation Nuclei On Deep Convective Cloud Updrafts – A Multimodel Assessment

This study presents results from a model intercomparison project, focusing on the range of responses in deep convective cloud updrafts to varying cloud condensation nuclei (CCN) concentrations amongst seven, state-of-the-art, cloud-resolving models. Simulations of scattered convective clouds near Houston, Texas are conducted, after being initialized with both relatively low and high CCN concentrations. Deep convective updrafts are identified, and trends in the updraft intensity and frequency are assessed. The factors contributing to the vertical velocity tendencies are examined to identify the physical processes associated with the CCN-induced, updraft changes. The models show several consistent trends. In general, the changes between the High- CCN and Low-CCN simulations in updraft magnitudes throughout the depth of the troposphere are within 15% for all of the models. All models produce stronger (~+5-15%) mean updrafts from ~4–7 km above ground level (AGL) in the High-CCN simulations, followed by a waning response up to ~8 km AGL in most of the models. Thermal buoyancy was more sensitive than condensate loading to varying CCN concentrations in most of the models and more impactful in the mean updraft responses. However, there are also differences between the models. The change in the amount of deep convective updrafts varies significantly. Furthermore, approximately half the models demonstrate neutral-to-weaker (~-5-0%) updrafts above ~8 km AGL, while the other models show stronger (~+10%) updrafts in the High-CCN simulations. The combination of the CCN-induced impacts on the buoyancy and vertical perturbation pressure gradient terms better explains these middle- and upper-tropospheric updraft trends than the buoyancy terms alone.

deep convective cloud updrafts↗

Alabama Ground Operations during the Deep Convective Clouds and Chemistry Experiment

The Deep Convective Clouds and Chemistry (DC3) field campaign investigates the impact of deep, midlatitude convective clouds, including their dynamical, physical and lighting processes, on upper tropospheric composition and chemistry. DC3 science operations took place from 14 May to 30 June 2012. The DC3 field campaign utilized instrumented aircraft and ground ]based observations. The NCAR Gulfstream ]V (GV) observed a variety of gas ]phase species, radiation and cloud particle characteristics in the high ]altitude outflow of storms while the NASA DC ]8 characterized the convective inflow. Groundbased radar networks were used to document the kinematic and microphysical characteristics of storms. In order to study the impact of lightning on convective outflow composition, VHF ]based lightning mapping arrays (LMAs) provided detailed three ]dimensional measurements of flashes. Mobile soundings were utilized to characterize the meteorological environment of the convection. Radar, sounding and lightning observations were also used in real ]time to provide forecasting and mission guidance to the aircraft operations. Combined aircraft and ground ]based observations were conducted at three locations, 1) northeastern Colorado, 2) Oklahoma/Texas and 3) northern Alabama, to study different modes of deep convection in a variety of meteorological and chemical environments. The objective of this paper is to summarize the Alabama ground operations and provide a preliminary assessment of the ground ]based observations collected over northern Alabama during DC3. The multi ] Doppler, dual ]polarization radar network consisted of the UAHuntsville Advanced Radar for Meteorological and Operational Research (ARMOR), the UAHuntsville Mobile Alabama X ]band (MAX) radar and the Hytop (KHTX) Weather Surveillance Radar 88 Doppler (WSR ]88D). Lightning frequency and structure were observed in near real ]time by the NASA MSFC Northern Alabama LMA (NALMA). Pre ]storm and inflow proximity soundings were obtained with the UAHuntsville mobile sounding unit and the Redstone Arsenal (QAG) morning sounding.

Carey, Lawrence↗

Properties of deep convective clouds in the ISCCP Pilot Data Set

Statistics on tropical deep convective clouds in the International Satellite Cloud Climatology Project Pilot Data Set are compiled by binning daytime data over areas of 2 X 2.5, 4 X 5, and 8 X 10 degrees. To isolate the convective clouds, only pixels with minimum visible optical thickness of 32 and maximum cloud top pressure of 550 mb are considered. Maps of convective cloud cover and frequency of convective events and frequency histograms of deep convective cloud pixels and cloud top pressures are presented.

Del Genio, Anthony D.↗

Simulation of Shallow Cumuli and Their Transition to Deep Convective Clouds by Cloud-resolving Models with Different Third-order Turbulence Closures

The abilities of cloud-resolving models (CRMs) with the double-Gaussian based and the single-Gaussian based third-order closures (TOCs) to simulate the shallow cumuli and their transition to deep convective clouds are compared in this study. The single-Gaussian based TOC is fully prognostic (FP), while the double-Gaussian based TOC is partially prognostic (PP). The latter only predicts three important third-order moments while the former predicts all the thirdorder moments. A shallow cumulus case is simulated by single-column versions of the FP and PP TOC models. The PP TOC improves the simulation of shallow cumulus greatly over the FP TOC by producing more realistic cloud structures. Large differences between the FP and PP TOC simulations appear in the cloud layer of the second- and third-order moments, which are related mainly to the underestimate of the cloud height in the FP TOC simulation. Sensitivity experiments and analysis of probability density functions (PDFs) used in the TOCs show that both the turbulence-scale condensation and higher-order moments are important to realistic simulations of the boundary-layer shallow cumuli. A shallow to deep convective cloud transition case is also simulated by the 2-D versions of the FP and PP TOC models. Both CRMs can capture the transition from the shallow cumuli to deep convective clouds. The PP simulations produce more and deeper shallow cumuli than the FP simulations, but the FP simulations produce larger and wider convective clouds than the PP simulations. The temporal evolutions of cloud and precipitation are closely related to the turbulent transport, the cold pool and the cloud-scale circulation. The large amount of turbulent mixing associated with the shallow cumuli slows down the increase of the convective available potential energy and inhibits the early transition to deep convective clouds in the PP simulation. When the deep convective clouds fully develop and the precipitation is produced, the cold pools produced by the evaporation of the precipitation are not favorable to the formation of shallow cumuli.

Cheng, Anning↗

Aerosol Radiative Effects on Deep Convective Clouds and Associated Radiative Forcing

The aerosol radiative effects (ARE) on the deep convective clouds are investigated by using a spectral-bin cloud-resolving model (CRM) coupled with a radiation scheme and an explicit land surface model. The sensitivity of cloud properties and the associated radiative forcing to aerosol single-scattering albedo (SSA) are examined. The ARE on cloud properties is pronounced for mid-visible SSA of 0.85. Relative to the case excluding the ARE, cloud fraction and optical depth decrease by about 18% and 20%, respectively. Cloud droplet and ice particle number concentrations, liquid water path (LWP), ice water path (IWP), and droplet size decrease significantly when the ARE is introduced. The ARE causes a surface cooling of about 0.35 K and significantly high heating rates in the lower troposphere (about 0.6K/day higher at 2 km), both of which lead to a more stable atmosphere and hence weaker convection. The weaker convection and the more desiccation of cloud layers explain the less cloudiness, lower cloud optical depth, LWP and IWP, smaller droplet size, and less precipitation. The daytime-mean direct forcing induced by black carbon is about 2.2 W/sq m at the top of atmosphere (TOA) and -17.4 W/sq m at the surface for SSA of 0.85. The semi-direct forcing is positive, about 10 and 11.2 W/sq m at the TOA and surface, respectively. Both the TOA and surface total radiative forcing values are strongly negative for the deep convective clouds, attributed mostly to aerosol indirect forcing. Aerosol direct and semi-direct effects are very sensitive to SSA. Because the positive semi-direct forcing compensates the negative direct forcing at the surface, the surface temperature and heat fluxes decrease less significantly with the increase of aerosol absorption (decreasing SSA). The cloud fraction, optical depth, convective strength, and precipitation decrease with the increase of absorption, resulting from a more stable and dryer atmosphere due to enhanced surface cooling and atmospheric heating.

Fan, J.↗

Saharan Dust Aerosols Change Deep Convective Cloud Prevalence, Possibly by Inhibiting Marine New Particle Formation

Deep convective clouds (DCCs) are important to global climate, atmospheric chemistry, and precipitation. Dust, a dominant aerosol type over the tropical North Atlantic, has potentially large microphysical impacts on DCCs over this region. However, dust effects are difficult to identify, being confounded by co-varying meteorology and other factors. Here, a method is developed to quantify DCC responses to dust and other aerosols at large spatial and temporal scales despite these uncertainties. Over 7 million tropical North Atlantic cloud, aerosol, and meteorological profiles from CloudSat satellite data and MERRA-2 reanalysis products are used to stratify cloud observations into meteorological regimes, objectively select a priori assumptions, and iteratively test uncertainty sensitivity. Dust is robustly associated with a 54% increase in DCC prevalence. However, marine aerosol proxy concentrations are five times more predictive of dust-associated increases in DCC prevalence than the dust itself, or any other aerosol or meteorological factor. Marine aerosols are also the most predictive factor for the even larger increases in DCC prevalence (61-87%) associated with enhanced dimethyl sulfide and combustion and sulfate aerosols. Dust-associated increases in DCC prevalence are smaller at high dust concentrations than at low concentrations. These observations suggest that not only is dust a comparatively ineffective CCN source, but it may also act as a condensation/coagulation sink for chemical precursors to CCN, reducing total CCN availability over large spatial scales by inhibiting new particle formation from marine emissions. These observations represent the first time this rocess, previously predicted by models, is supported and quantified by measurements.

Aerosol-cloud interactions↗

Application of Quasi-Deep Convective Clouds Method for VIIRS and MODIS TEB Calibration Assessments

A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit blackbody (BB) warm-up and cooldown operations for updates. However, a limited BB temperature range affects the calibration’s accuracy particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide with the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, this qDCC method is applied to the Terra MODIS and VIIRS TEB; and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31 and VIIRS bands M15 and I5, are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows their TEB measurements are consistent over qDCC. The Terra MODIS TEB also show stable performance – except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, while bands 27 and 29 show slight, upward drifts. Lastly, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.

MODIS↗

VIIRS Reflective Solar Band Radiometric and Stability Evaluation Using Deep Convective Clouds

This work takes advantage of the stable distribution of deep convective cloud (DCC) reflectance measurements to assess the calibration stability and detector difference in Visible Infrared Imaging Radiometer Suite (VIIRS) reflective bands. VIIRS Sensor Data Records (SDRs) from February 2012 to June 2015 are utilized to analyze the long-term trending, detector difference, and half angle mirror (HAM) side difference. VIIRS has two thermal emissive bands with coverage crossing 11 microns for DCC pixel identification. The comparison of the results of these two processing bands is one of the indicators of analysis reliability. The long-term stability analysis shows downward trends (up to approximately 0.4 per year) for the visible and near-infrared bands and upward trends (up to 0.5per year) for the short- and mid-wave infrared bands. The detector difference for each band is calculated as the difference relative to the average reflectance overall detectors. Except for the slightly greater than 1 difference in the two bands at 1610 nm, the detector difference is less than1 for other solar reflective bands. The detector differences show increasing trends for some short-wave bands with center wavelengths from 400 to 600 nm and remain unchanged for the bands with longer center wavelengths. The HAM side difference is insignificant and stable. Those short-wave bands from 400 to 600 nm also have relatively larger HAM side difference, up to 0.25.Comparing the striped images from SDR and the smooth images after the correction validates the analyses of detector difference and HAM side difference. These analyses are very helpful for VIIRS calibration improvement and thus enhance product quality

VIIRS↗

On the Use of Deep Convective Clouds to Calibrate AVHRR Data

Remote sensing of cloud and radiation properties from National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) satellites requires constant monitoring of the visible sensors. NOAA satellites do not have onboard visible calibration and need to be calibrated vicariously in order to determine the calibration and the degradation rate. Deep convective clouds are extremely bright and cold, are at the tropopause, have nearly a Lambertian reflectance, and provide predictable albedos. The use of deep convective clouds as calibration targets is developed into a calibration technique and applied to NOAA-16 and NOAA-17. The technique computes the relative gain drift over the life-span of the satellite. This technique is validated by comparing the gain drifts derived from inter-calibration of coincident AVHRR and Moderate-Resolution Imaging Spectroradiometer (MODIS) radiances. A ray-matched technique, which uses collocated, coincident, and co-angled pixel satellite radiance pairs is used to intercalibrate MODIS and AVHRR. The deep convective cloud calibration technique was found to be independent of solar zenith angle, by using well calibrated Visible Infrared Scanner (VIRS) radiances onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, which precesses through all solar zenith angles in 23 days.

Doelling, David R.↗

Behavior of deep convective clouds in the tropical Pacific deduced from ISCCP radiances

The characteristic features, the diurnal cycle, and the spatial distribution of deep convection over the equatorial Pacific and the relationship of deep convection to SST and surface-wind convergence were examined using a combined visible-IR (VS-IR) threshold method and an IR-only threshold method for diagnosing deep convection clouds (DCCs). Results suggest that deep convection is latitudinally confined to a much smaller spatial scale than that suggested by maps of outgoing long-wave radiation. The results suggested that there are two types of relationships between deep convection, SST, and surface-wind convergence: the west Pacific type and the east Pacific type. The latter relationship is observed in the east Pacific only when SST is not abnormally warm.

Fu, Rong↗

The Characterization of Deep Convective Clouds as an Invariant Calibration Target and as a Visible Calibration Technique

Deep convective clouds (DCCs) are ideal visible calibration targets because they are bright nearly isotropic solar reflectors located over the tropics and they can be easily identified using a simple infrared threshold. Because all satellites view DCCs, DCCs provide the opportunity to uniformly monitor the stability of all operational sensors, both historical and present. A collective DCC anisotropically corrected radiance calibration approach is used to construct monthly probability distribution functions (PDFs) to monitor sensor stability. The DCC calibration targets were stable to within 0.5% and 0.3% per decade when the selection criteria were optimized based on Aqua MODerate Resolution Imaging Spectroradiometer 0.65-micrometer-band radiances. The Tropical Western Pacific (TWP), African, and South American regions were identified as the dominant DCC domains. For the 0.65-micrometer band, the PDF mode statistic is preferable, providing 0.3%regional consistency and 1%temporal uncertainty over land regions. It was found that the DCC within the TWP had the lowest radiometric response and DCC over land did not necessarily have the highest radiometric response. For wavelengths greater than 1 micrometer, the mean statistic is preferred, and land regions provided a regional variability of 0.7%with a temporal uncertainty of 1.1% where the DCC land response was higher than the response over ocean. Unlike stratus and cirrus clouds, the DCC spectra were not affected by water vapor absorption.

Doelling, David R.↗

Application of quasi-deep convective clouds method for MODIS and VIIRS TEB calibration assessments

A technique to use deep convective clouds (DCC) and quasi-DCC (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has proven feasible. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit black body (BB) warm-up and cool-down (WUCD) activities for updates. However, the limited BB temperature range affects the calibration’s uncertainty. The DCC core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, the qDCC method is applied to the Terra MODIS and VIIRS TEB. Their stabilities are assessed using long-term DCC and qDCC trending measurements over the instruments’ entire missions. The measurements from bands with an approximately 11-μm wavelength are used to identify the DCC pixels. MODIS band31 (~ 11m) has demonstrated stable performance and accurate calibration for both instruments throughout their respective missions. MODIS band31 can therefore be used as a reference for the other TEB. Furthermore, it also allows for a Terra and Aqua MODIS TEB cross-comparison. The assessment results, along with the calibration uncertainty and Level 1B product impact modeling, can be quite helpful for calibration improvements.

MODIS↗

Comparisons of Cloud In-Situ Microphysical Properties of Deep Convective Clouds to Appendix D/P, Using Data from the HAIC-HIWC and HIWC RADAR I Flight Campaigns

In-situ cloud data from three international flight campaigns is compared to the new Federal Aviation Administration (FAA) Title 14 Code of Federal Regulations Part 33 Appendix D mixed-phase/glaciated environmental envelope (1), and the corresponding identical European Aviation Safety Agency (EASA) CS-25 Appendix P envelope (2) (hereafter "Appendix D/P"). Appendix D/P consists of a temperature-altitude envelope, a 99th percentile total water content (TWC99) envelope at the 17.4 Nm distance scale, a distance factor to estimate TWC99 values at other distance scales, ice crystal median mass diameter (MMD), and recommended liquid water content (LWC) levels in mixed-phase icing conditions. The dataset is from 45 flight missions in 3 tropical locations, with 472 runs in approximately 115 clouds, providing about 29,600 Nm of in-cloud data in deep convection over four targeted temperature intervals: 10, 30, 40, and 50 +5 C. The measurements span altitueds from about 17,000' to 39,000'. The comparisons will serve as a basis for regulatory and industry assessment of the efficacy of Appendix D/P.

Strapp, J. Walter↗

Estimating Glaciation Temperature of Deep Convective Clouds with Remote Sensing Data

Major uncertainties exist for observing and modeling ice content inside deep convective clouds (DCC). One of the difficulties has been the lack of characterization of vertical profiles of cloud hydrometeor phase. Here we propose a technique to estimate the DCC glaciation temperature using passive remote sensing data. It is based on a conceptual model of vertical hydrometeor size profiles inside DCCs. Estimates from the technique agree well with our general understanding of the problem. Furthermore, the link between vertical profiles of cloud particle size and hydrometeor thermodynamic phase is confirmed by a 3-13 cloud retrieval technique. The technique is applied to aircraft measurements of cloud side reflectance and the result was compared favorably with an independent retrieval of thermodynamic phase based on different refractive indices at 2.13 micron and 2.25 micron. Possible applications of the technique are discussed.

Yuan, Tianle↗

Frequency of Deep Convective Clouds and Global Warming

This slide presentation reviews the effect of global warming on the formation of Deep Convective Clouds (DCC). It concludes that nature responds to global warming with an increase in strong convective activity. The frequency of DCC increases with global warming at the rate of 6%/decade. The increased frequency of DCC with global warming alone increases precipitation by 1.7%/decade. It compares the state of the art climate models' response to global warming, and concludes that the parametrization of climate models need to be tuned to more closely emulate the way nature responds to global warming.

infrared↗

The Use of the Deep Convective Cloud Technique (DCCT) to Monitor On-Orbit Performance of the Geostationary Lightning Mapper (GLM): Use of Lightning Imaging Sensor (LIS) Data as Proxy

The Geostationary Lightning Mapper (GLM) on the next generation Geostationary Operational Environmental Satellite-R (GOES-R) will not have onboard calibration capability to monitor its performance. The Lightning Imaging Sensor (LIS) onboard the Tropical Rainfall Measuring Mission (TRMM) satellite has been providing observations of total lightning over the Earth's Tropics since 1997. The GLM design is based on LIS heritage, making it a good proxy dataset. This study examines the performance of LIS throughout its time in orbit. This was accomplished through application of the Deep Convective Cloud Technique (DCCT) (Doelling et al., 2004) to LIS background pixel radiance data. The DCCT identifies deep convective clouds by their cold Infrared (IR) brightness temperatures and using them as invariant targets in the solar reflective portion of the solar spectrum. The GLM and LIS operate in the near-IR at a wavelength of 777.4 nm. In the present study the IR data is obtained from the Visible Infrared Sensor (VIRS) which is collocated with LIS onboard the Tropical Rainfall Measuring Mission (TRMM) satellite. The DCCT is applied to LIS observations for July and August of each year from 1998-2010. The resulting distributions of LIS background DCC pixel radiance for each July August are very similar, indicating stable performance. The mean radiance of the DCCT analysis does not show a long term trend and the maximum deviation of the July August mean radiance for each year is within 0.7% of the overall mean. These results demonstrate that there has been no discernible change in LIS performance throughout its lifetime. A similar approach will used for monitoring the performance of GLM, with cold clouds identified using IR data from the Advanced Baseline Imager (ABI) which will also be located on GOES-R. Since GLM is based on LIS design heritage, the LIS results indicate that GLM should also experience stable performance over its lifetime.

Buechler, Dennis E.↗