Search NASA⌕ Search

SEARCH · Search NASA

Results for “deformation cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of Gravity on the Mammalian Cell Deformation

The effect of human cell immersed in culture liquid under a micro-gravity environment has been investigated. The study is based on the numerical simulation of the configuration of human cell affected by the time dependent variation of gravity acceleration ranging from 10(exp -3) to 2 g(sub o) (g(sub o) = 9.81 m/s(exp 2)) in 15 seconds. Both the free floating cell and the cell contacted to the upper and lower inclined walls imposed by the time-dependent reduced gravity acceleration are considered in this study. The results show that the cell configuration changes from spherical to horizontally elongated ellipsoid for both the free floating cell and the cell sitting on the lower inclined wall while the cell configuration varies from spherical to vertically elongated ellipsoid for the cell hanging to the upper inclined wall when the gravity acceleration increases. Experimental observations, carried out of human cells exposed to the variation of gravity levels, show that the results of experimental observations agree exactly with the theoretical model computation described in this paper. These results sre significant for humans exposed to the micro-gravity environment.

Hung, R. J.↗

Inflight Assay of Red Blood Cell Deformability

Studies on Soviet and American astronauts have demonstrated that red blood cell production is altered in response to low gravity (g) environment. This is associated with changes in individual red cells including increased mean cell volume and altered membrane deformability. During long orbital missions, there is a tendency for the red cell mass deficit to be at least partly corrected although the cell shape anomalies are not. Data currently available suggest that the observed decrease in red cell mass is the result of sudden suppression of erythropoieses and that the recovery trend observed during long missions reflects re-establishment of erythropoietic homeostasis at a "set point" for the red cell mass that is slightly below the normal level at 1 g.

Ingram, M.↗

Measurements of cell-generated deformations on flexible substrata using correlation-based optical flow

The optical flow algorithm presented here is a robust method that rapidly yields a high-density field of substrate displacement vectors based on two optical images. We found that one of the limiting factors, at least for inexperienced experimentalists, is the consistency of focusing or the drift in microscope focus. However, with properly collected images the standard error of the measurement was estimated to be on the order of +/- 0.10 pixels. Finally, although the discussion has been focused on the displacement of flexible substrata, a similar method should be applicable for detecting movements on other types of images, as long as the movement involves a certain degree of local coordination.

Non-NASA Center↗

Mechanotransduction in bone: osteoblasts are more responsive to fluid forces than mechanical strain

Mechanical force applied to bone produces two localized mechanical signals on the cell: deformation of the extracellular matrix (substrate strain) and extracellular fluid flow. To study the effects of these stimuli on osteoblasts, MC3T3-E1 cells were grown on type I collagen-coated plastic plates and subjected to four-point bending. This technique produces uniform levels of physiological strain and fluid forces on the cells. Each of these parameters can be varied independently. Osteopontin (OPN) mRNA expression was used to assess the anabolic response of MC3T3-E1 cells. When fluid forces were low, neither strain magnitude nor strain rate was correlated with OPN expression. However, higher-magnitude fluid forces significantly increased OPN message levels independently of the strain magnitude or rate. These data indicate that fluid forces, and not mechanical stretch, influence OPN expression in osteoblasts and suggest that fluid forces induced by extracellular fluid flow within the bone matrix may play an important role in bone formation in response to mechanical loading.

Non-NASA Center↗

Kinematics of Strong Discontinuities

Synthetic Aperture Radar (SAR) provides a detailed view of the Arctic ice cover. When processed with the RADARSAT Geophysical Processor System (RGPS), it provides estimates of sea ice motion and deformation over large regions of the Arctic for extended periods of time. The deformation is dominated by the appearance of linear kinematic features that have been associated with the presence of leads. The RGPS deformation products are based on the assumption that the displacement and velocity are smooth functions of the spatial coordinates. However, if the dominant deformation of multiyear ice results from the opening, closing and shearing of leads, then the displacement and velocity can be discontinuous. This presentation discusses the kinematics associated with strong discontinuities that describe possible jumps in displacement or velocity. Ice motion from SAR data are analyzed using this framework. It is assumed that RGPS cells deform due to the presence of a lead. The lead orientation is calculated to optimally account for the observed deformation. It is shown that almost all observed deformation can be represented by lead opening and shearing. The procedure used to reprocess motion data to account for leads will be described and applied to regions of the Beaufort Sea. The procedure not only provides a new view of ice deformation, it can be used to obtain information about the presence of leads for initialization and/or validation of numerical simulations.

Peterson, K.↗

Crush Test Abuse Stand

The purpose of this system is to simulate an internal short on battery cells by causing deformation (a crushing force) in a cell without penetration. This is performed by activating a hydraulic cylinder on one side of a blast wall with a hydraulic pump located on the other. The operator can control the rate of the crush by monitoring a local pressure gauge connected to the hydraulic cylinder or a load cell digital display located at the hydraulic pump control area. The internal short simulated would be considered a worst-case scenario of a manufacturer fs defect. This is a catastrophic failure of a cell and could be a very destructive event. Fully charged cells are to have an internal short simulated at the center of the length of the cell (away from terminals). The crush can be performed with a .- to 1-in. (.0.6- to 2.5-cm) rod placed crossways to the cell axis, causing deformation of the cell without penetration. The OCV (open-circuit voltage) and temperature of the cells, as well as the pressure and crushing force, are recorded during the operation. Occurrence of an internal short accompanied by any visible physical changes such as venting, fires, or explosions is reported. Typical analytical data examined after the test would be plots of voltage, temperature, and pressure or force versus time. The rate of crushing force can be increased or decreased based on how fast the operator pumps the hydraulic pump. The size of cylinder used to compress the battery cell can be easily changed by adding larger or smaller fittings onto the end of the hydraulic cylinder based on the battery/cell size being tested. The cell is crushed remotely and videotaped, allowing the operator to closely monitor the situation from a safe distance.

Collins, Jacob↗

Utilization of the Generalized Method of Cells to Analyze the Deformation Response of Laminated Ceramic Matrix Composites

In order to practically utilize ceramic matrix composites in aircraft engine components, robust analysis tools are required that can simulate the material response in a computationally efficient manner. The MAC/GMC software developed at NASA Glenn Research Center, based on the Generalized Method of Cells micromechanics method, has the potential to meet this need. Utilizing MAC/GMC, the effective stiffness properties, proportional limit stress and ultimate strength can be predicted based on the properties and response of the individual constituents. In this paper, the effective stiffness and strength properties for a representative laminated ceramic matrix composite with a large diameter fiber are predicted for a variety of fiber orientation angles and laminate orientations. As part of the analytical study, methods to determine the in-situ stiffness and strength properties of the constituents required to appropriately simulate the effective composite response are developed. The stiffness properties of the representative composite have been adequately predicted for all of the fiber orientations and laminate configurations examined in this study. The proportional limit stresses and strains and ultimate stresses and strains were predicted with varying levels of accuracy, depending on the laminate orientation. However, for the cases where the predictions did not have the desired level of accuracy, the specific issues related to the micromechanics theory were identified which could lead to difficulties that were encountered that could be addressed in future work.

Goldberg, Robert K.↗

Safety and Long-Term Performance of Lithium-ion Pouch Cells

Lithium-ion batteries have the highest energy density of the batteries available in the commercial market today. Although most lithium-ion cell designs use a metal can design, this has changed significantly in recent years. Cell designs are offered in the pouch format as they offer better volumetric and gravimetric energy densities and in some cases, higher tolerance to abuse or off-nominal conditions. In the past decade, several state-of-the-art lithium-ion pouch cell designs have been tested. The pouch cell designs have become more robust in the past two years but there are still a few issues that need to be looked into for optimization. The pouch cells seem to have a tendency to swell when left in storage under ambient conditions. The cells also swell under overvoltage and undervoltage conditions. A significant issue that has been observed is the swelling of the cells under a vacuum condition which could lead to deformation of the cell pouch after this exposure. This last factor would be very critical in the use of these cell designs for space applications as vacuum exposure is used to check for cell and battery leaks before it is flown into space. In rare cases, corrosion of the aluminum layer of the pouches has been observed in stored cells. Pouch material analysis has been carried out in an effort to understand the strength of the pouches and determine if this is a factor in the corrosion as well as unsafe condition of the cells as deformation of the inner layers of the pouch could occur when the cells swell under the various conditions described above. Pouch materials are typically aluminized plastic, made up of a layer of Al sandwiched between one or more layers of polymeric material. Deformations or cell manufacturing processes could lead to a compromise of the inner polymeric layer/s of the pouch leading to the corrosion of the Al layer in the aluminized pouch material. The safety of the pouch cell designs has been determined for cells from various manufacturers. The results are varied and in some cases, unexpected. This paper presents a summary of the tests carried out on a few li-ion pouch cell designs from various cell manufacturers. The data will include performance under different conditions specifically cycling under vacuum conditions with and without restraints as well as safety test data. The presentation will also include detailed analysis of the pouch material for the cells studied.

Jeevarajan, Judith↗

Miniature load cell instrumentation for finite deformation biaxial testing of elastomers

Accuracy of biaxial test equipment to examine the nonlinear mechanical behavior of thin sheet specimens of elastomeric materials has been hampered by lack of precise determination of the force distribution along the sides of the specimen. It has been necessary to use an effective width established by approximate means to obtain the stress from the overall force applied along the edges. To avoid this experimental difficulty, individual miniature proof-ring load cells utilizing semiconductor strain gages have been developed and applied to the support hooks for the thin sheet specimens. Typical results are shown for time-dependent stress distributions for all degrees of biaxiality. An accurate evaluation of the effective specimen width is now possible.

Arenz, R. J.↗

Characterization of Triaxial Braided Composite Material Properties for Impact Simulation

The reliability of impact simulations for aircraft components made with triaxial braided carbon fiber composites is currently limited by inadequate material property data and lack of validated material models for analysis. Improvements to standard quasi-static test methods are needed to account for the large unit cell size and localized damage within the unit cell. The deformation and damage of a triaxial braided composite material was examined using standard quasi-static in-plane tension, compression, and shear tests. Some modifications to standard test specimen geometries are suggested, and methods for measuring the local strain at the onset of failure within the braid unit cell are presented. Deformation and damage at higher strain rates is examined using ballistic impact tests on 61- by 61- by 3.2-mm (24- by 24- by 0.125-in.) composite panels. Digital image correlation techniques were used to examine full-field deformation and damage during both quasi-static and impact tests. An impact analysis method is presented that utilizes both local and global deformation and failure information from the quasi-static tests as input for impact simulations. Improvements that are needed in test and analysis methods for better predictive capability are examined.

Roberts, Gary D.↗

Three-Dimensional Deformable Grid Electromagnetic Particle-in-cell for Parallel Computers

We describe a new parallel, non-orthogonal grid, three-dimensional electromagnetic particle-in-cell (EMPIC) code based on a finite-volume formulation. This code uses a logically Cartesian grid of deformable hexahedral cells, a discrete surface integral (DSI) algorithm to calculate the electromagnetic field, and a hybrid logical-physical space algorithm to push particles.

Cartesian grid Grid Electromagnetic electromagneti↗

Microstructural Influence on Deformation and Fatigue Life of Composites Using the Generalized Method of Cells

A fully coupled deformation and damage approach to modeling the response of composite materials and composite laminates is presented. It is based on the semi-­‐analytical generalized method of cells (GMC) micromechanics model as well as its higher fidelity counterpart, HFGMC, both of which provide closed-form constitutive equations for composite materials as well as the micro scale stress and strain fields in the composite phases. The provided constitutive equations allow GMC and HFGMC to function within a higher scale structural analysis (e.g., finite element analysis or lamination theory) to represent a composite material point, while the availability of the micro fields allow the incorporation of lower scale sub­‐models to represent local phenomena in the fiber and matrix. Further, GMC's formulation performs averaging when applying certain governing equations such that some degree of microscale field accuracy is surrendered in favor of extreme computational efficiency, rendering the method quite attractive as the centerpiece in a integrated computational material engineering (ICME) structural analysis; whereas HFGMC retains this microscale field accuracy, but at the price of significantly slower computational speed. Herein, the sensitivity of deformation and the fatigue life of graphite/epoxy PMC composites, with both ordered and disordered microstructures, has been investigated using this coupled deformation and damage micromechanics based approach. The local effects of fiber breakage and fatigue damage are included as sub‐models that operate on the microscale for the individual composite phases. For analysis of laminates, classical lamination theory is employed as the global or structural scale model, while GMC/HFGMC is embedded to operate on the microscale to simulate the behavior of the composite material within each laminate layer. A key outcome of this study is the statistical influence of microstructure and micromechanics idealization (GMC or HFGMC) on the overall accuracy of unidirectional and laminated composite deformation and fatigue response.

Microscale Models↗

Adaptive Optics: Arroyo Simulation Tool and Deformable Mirror Actuation Using Golay Cells

The Arroyo C++ libraries, written by Caltech post-doc student Matthew Britton, have the ability to simulate optical systems and atmospheric signal interference. This program was chosen for use in an end-to-end simulation model of a laser communication system because it is freely distributed and has the ability to be controlled by a remote system or "smart agent." Proposed operation of this program by a smart agent has been demonstrated, and the results show it to be a suitable simulation tool. Deformable mirrors, as a part of modern adaptive optics systems, may contain thousands of tiny, independently controlled actuators used to modify the shape of the mirror. Each actuator is connected to two wires, creating a cumbersome and expensive device. Recently, an alternative actuation method that uses gas-filled tubes known as Golay cells has been explored. Golay cells, operated by infrared lasers instead of electricity, would replace the actuator system thereby creating a more compact deformable mirror. The operation of Golay cells and their ability to move a deformable mirror in excess of the required 20 microns has been demonstrated. Experimentation has shown them to be extremely sensitive to pressure and temperature, making them ideal for use in a controlled environment.

Lint, Adam S.↗

Method and system for measurement of mechanical properties of molecules and cells

Mechanical stresses and deformations are applied directly to cell surface receptors or molecules and measured using a system including a magnetic twisting device in combination with ferromagnetic microbeads coated with ligands for integrins or any other surface receptors. The system can be used diagnostically to characterize cells and molecules and to determine the effect of transformation and compounds, including drugs, on the cells and molecules. The system can also be used to induce cells to grow or alter production of molecules by the cells.

Butler, James P.↗

Receptor-based differences in human aortic smooth muscle cell membrane stiffness

Cells respond to mechanical stimuli with diverse molecular responses. The nature of the sensory mechanism involved in mechanotransduction is not known, but integrins may play an important role. The integrins are linked to both the cytoskeleton and extracellular matrix, suggesting that probing cells via integrins should yield different mechanical properties than probing cells via non-cytoskeleton-associated receptors. To test the hypothesis that the mechanical properties of a cell are dependent on the receptor on which the stress is applied, human aortic smooth muscle cells were plated, and magnetic beads, targeted either to the integrins via fibronectin or to the transferrin receptor by use of an IgG antibody, were attached to the cell surface. The resistance of the cell to deformation ("stiffness") was estimated by oscillating the magnetic beads at 1 Hz by use of single-pole magnetic tweezers at 2 different magnitudes. The ratio of bead displacements at different magnitudes was used to explore the mechanical properties of the cells. Cells stressed via the integrins required approximately 10-fold more force to obtain the same bead displacements as the cells stressed via the transferrin receptors. Cells stressed via integrins showed stiffening behavior as the force was increased, whereas this stiffening was significantly less for cells stressed via the transferrin receptor (P<0.001). Mechanical characteristics of vascular smooth muscle cells depend on the receptor by which the stress is applied, with integrin-based linkages demonstrating cell-stiffening behavior.

Non-NASA Center↗

Investigation of superconducting interactions and amorphous semiconductors

Research papers on superconducting interactions and properties and on amorphous materials are presented. The search for new superconductors with improved properties was largely concentrated on the study of properties of thin films. An experimental investigation of interaction mechanisms revealed no new superconductivity mechanism. The properties of high transition temperature, type 2 materials prepared in thin film form were studied. A pulsed field solenoid capable of providing fields in excess of 300 k0e was developed. Preliminary X-ray measurements were made of V3Si to determine the behavior of cell constant deformation versus pressure up to 98 kilobars. The electrical properties of amorphous semiconducting materials and bulk and thin film devices, and of amorphous magnetic materials were investigated for developing radiation hard, inexpensive switches and memory elements.

Janocko, M. A.↗

DSMC calculations for the delta wing

Results are reported from three-dimensional direct simulation Monte Carlo (DSMC) computations, using a variable-hard-sphere molecular model, of hypersonic flow on a delta wing. The body-fitted grid is made up of deformed hexahedral cells divided into six tetrahedral subcells with well defined triangular faces; the simulation is carried out for 9000 time steps using 150,000 molecules. The uniform freestream conditions include M = 20.2, T = 13.32 K, rho = 0.00001729 kg/cu m, and T(wall) = 620 K, corresponding to lambda = 0.00153 m and Re = 14,000. The results are presented in graphs and briefly discussed. It is found that, as the flow expands supersonically around the leading edge, an attached leeside flow develops around the wing, and the near-surface density distribution has a maximum downstream from the stagnation point. Coefficients calculated include C(H) = 0.067, C(DP) = 0.178, C(DF) = 0.110, C(L) = 0.714, and C(D) = 1.089. The calculations required 56 h of CPU time on the NASA Langley Voyager CRAY-2 supercomputer.

Celenligil, M. Cevdet↗

Structure of deformed silicon and implications for low-cost solar cells

The paper reports on an investigation of the microstructure and minority carrier lifetime of silicon in uniaxially compressed silicon samples, the objective of which was to determine if it is feasible to produce silicon solar cells from sheet formed by high temperature deformation. It is reported that recrystallization was found to be incomplete in both fine and large grained materials, and that the major mode of recrystallization appears to be migration of existing boundaries into the deformed regions. Also, minority carrier diffusion length was found to be drastically reduced after deformation, perhaps due to contamination or cooling rate, and recovered only slightly with annealing. It is concluded that these results suggest that high temperature deformation of silicon for direct production of sheet for high efficiency solar cells is not practical. It is noted that potential may exist for its use as a coarse grained substrate.

Mardesich, N.↗