Search NASA⌕ Search

SEARCH · Search NASA

Results for “degradation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Compendium of photovoltaic degradation rates

Abstract Published data on photovoltaic (PV) degradation measurements were aggregated and re‐examined. The subject has seen an increased interest in recent years resulting in more than 11 000 degradation rates in almost 200 studies from 40 different countries. As studies have grown in number and size, we found an impact from sampling bias attributable to size and accuracy. Because of the correlational nature of this study we examined the data in several ways to minimize this bias. We found median degradation for x‐Si technologies in the 0.5–0.6%/year range with the mean in the 0.8–0.9%/year range. Hetero‐interface technology (HIT) and microcrystalline silicon (µc‐Si) technologies, although not as plentiful, exhibit degradation around 1%/year and resemble thin‐film products more closely than x‐Si. Several studies showing low degradation for copper indium gallium selenide (CIGS) have emerged. Higher degradation for cadmium telluride (CdTe) has been reported, but these findings could reflect a convolution of less accurate studies and longer stabilization periods for some products. Significant deviations for beginning‐of‐life measurements with respect to nameplate rating have been documented over the last 35 years. Therefore, degradation rates that use nameplate rating as reference may be significantly impacted. Studies that used nameplate rating as reference but used solar simulators showed less variation than similar studies using outdoor measurements, even when accounting for different climates. This could be associated with confounding effects of measurement uncertainty and soiling that take place outdoors. Hotter climates and mounting configurations that lead to sustained higher temperatures may lead to higher degradation in some, but not all, products. Wear‐out non‐linearities for the worst performing modules have been documented in a few select studies that took multiple measurements of an ensemble of modules during the lifetime of the system. However, the majority of these modules exhibit a fairly linear decline. Modeling these non‐linearities, whether they occur at the beginning‐of‐life or end‐of‐life in the PV life cycle, has an important impact on the levelized cost of energy. Copyright © 2016 John Wiley & Sons, Ltd.

Jordan, Dirk C.↗

Use of Pyranometers to Estimate PV Module Degradation Rates in the Field

Methodology is described that uses relative measurements to estimate the degradation rates of PV modules in the field. The importance of calibration and cleaning is discussed. The number of years of field measurements needed to measure degradation rates with data from the field is cut in half using relative comparisons.

14 SOLAR ENERGY↗

BACKFLIP Project: Determination of BACKsheet Material Properties: A Comparison of Market-Benchmark Technologies to Novel Non-Fluoro-Based Co-Extruded Backsheet Materials and Their Correlation and Impact on PV Module Degradation Rates

Quantifying degradation rate of backsheets will help procuring materials for 30+ years. Today most backsheets on the market have a laminated PET core; polyolefin materials may provide better properties for backsheets (barrier to water, mechanical properties through UV and hydrolytic environments, etc.). End-of-life regulations may require fluorine-free backsheet products in future global markets. Parametrized equation predicting the service life of backsheets, and validated by both lab and outdoor extensive testing. Technical and commercial confidence to the entire value chain: from backsheet and module manufacturers to the downstream community (IPP, banks, developers) that materials of higher quality can help reduce finance costs, therefore driving down LCOE. A fast track PV module market adaptation for novel high-quality materials, such as co-extruded polyolefin-core backsheets, by obtaining unbiased durability data.

14 SOLAR ENERGY↗

Membrane Thickness Impact on Chemical Degradation Rates

Abstract A comprehensive investigation of PFSA membrane chemical degradation rates as a function of thickness (8-20 µm) is reported. The two-pronged study was conducted on bare membranes and as components of chemically-mitigated and mechanically-reinforced, state-of-the-art (SOA) membrane electrode assemblies (MEAs). The bare membranes were subjected to H2O2 vapor test and MEAs were degraded under OCV conditions, both at 90°C. Both test types employed fluoride release rates (FRR) to monitor chemical degradation rates. Vapor tests revealed that area-specific degradation rates were positively correlated with membrane thickness, but thickness normalized degradation rates were independent of thickness. Open-circuit voltage (OCV) investigations spanning the membrane thickness series of MEAs was probed via a 27-experiment 3(4-1) fractional factorial experimental design. Statistical analysis of the FRR values revealed that chemical degradation rates were dominated by the relative humidity value and that the area-specific degradation rates of MEAs were independent of membrane thickness. The OCV chemical durability insensitivity to membrane thickness is supported by on-load membrane chemical durability studies at the stack level. The results suggest that ,despite smaller ionomer inventory, SOA thin membranes and MEAs are not greatly disadvantaged relative to thicker membranes from a chemical durability perspective, provided oxidative stress levels are controlled throughout application lifetime.

Coms, Frank D. (ORCID:0000000249160350)↗

Measuring Degradation Rates Without Irradiance Data

A method to report PV system degradation rates without using irradiance data is demonstrated. First, a set of relative degradation rates are determined by comparing daily AC final yields from a group of PV systems relative to the average final yield of all the PV systems. Then, the difference between relative and absolute degradation rates is found from a statistical analysis. This approach is verified by comparing to methods that utilize irradiance data. This approach is significant because PV systems are often deployed without irradiance sensors, so the analysis method described here may enable measurements of degradation using data that were previously thought to be unsuitable for degradation studies.

14 SOLAR ENERGY↗

Photovoltaic Degradation Rates -- An Analytical Review

As photovoltaic penetration of the power grid increases, accurate predictions of return on investment require accurate prediction of decreased power output over time. Degradation rates must be known in order to predict power delivery. This article reviews degradation rates of flat-plate terrestrial modules and systems reported in published literature from field testing throughout the last 40years. Nearly 2000 degradation rates, measured on individual modules or entire systems, have been assembled from the literature, showing a median value of 0.5%/year. The review consists of three parts: a brief historical outline, an analytical summary of degradation rates, and a detailed bibliography partitioned by technology.

14 SOLAR ENERGY↗

Reducing Interanalyst Variability in Photovoltaic Degradation Rate Assessments

The economic return on investment of a commercial photovoltaic system depends greatly on its performance over the long term and, hence, its degradation rate. Many methods have been proposed for assessing system degradation rates from outdoor performance data. However, comparing reported values from one analyst and research group to another requires a common baseline of performance; consistency between methods and analysts can be a challenge. An interlaboratory study was conducted involving different volunteer analysts reporting on the same photovoltaic performance data using different methodologies. Initial variability of the reported degradation rates was so high that analysts could not come to a consensus whether a system degraded or not. More consistent values are received when written guidance is provided to each analyst. Further improvements in analyst variance was accomplished by using the free open-source software RdTools, allowing a reduction in variance between analysts by more than two orders of magnitude over the first round, where multiple analysis methods are allowed. This article highlights many pitfalls in conducting 'routine' degradation analysis, and it addresses some of the factors that must be considered when comparing degradation results reported by different analysts or methods.

14 SOLAR ENERGY↗

Uncertainty Analysis for Photovoltaic Degradation Rates (Poster)

Dependable and predictable energy production is the key to the long-term success of the PV industry. PV systems show over the lifetime of their exposure a gradual decline that depends on many different factors such as module technology, module type, mounting configuration, climate etc. When degradation rates are determined from continuous data the statistical uncertainty is easily calculated from the regression coefficients. However, total uncertainty that includes measurement uncertainty and instrumentation drift is far more difficult to determine. A Monte Carlo simulation approach was chosen to investigate a comprehensive uncertainty analysis. The most important effect for degradation rates is to avoid instrumentation that changes over time in the field. For instance, a drifting irradiance sensor, which can be achieved through regular calibration, can lead to a substantially erroneous degradation rates. However, the accuracy of the irradiance sensor has negligible impact on degradation rate uncertainty emphasizing that precision (relative accuracy) is more important than absolute accuracy.

14 SOLAR ENERGY↗

Nonlinear Photovoltaic Degradation Rates: Modeling and Comparison Against Conventional Methods

Although common practice for estimating photovoltaic (PV) degradation rate (RD) assumes a linear behavior, field data have shown that degradation rates are frequently nonlinear. This article presents a new methodology to detect and calculate nonlinear RD based on PV performance time-series from nine different systems over an eight-year period. Prior to performing the analysis and in order to adjust model parameters to reflect actual PV operation, synthetic datasets were utilized for calibration purposes. A change-point analysis is then applied to detect changes in the slopes of PV trends, which are extracted from constructed performance ratio (PR) time-series. Once the number and location of change points is found, the ordinary least squares method is applied to the different segments to compute the corresponding rates. The obtained results verified that the extracted trends from the PR time-series may not always be linear and therefore, “nonconventional” models need to be applied. All thin-film technologies demonstrated nonlinear behavior whereas nonlinearity detected in the crystalline silicon systems is thought to be due to a maintenance event. A comparative analysis between the new methodology and other conventional methods demonstrated levelized cost of energy differences of up to 6.14%, highlighting the importance of considering nonlinear degradation behavior

14 SOLAR ENERGY↗

Impact of duration and missing data on the long-term photovoltaic degradation rate estimation

Accurate quantification of photovoltaic (PV) system degradation rate (R D ) is essential for lifetime yield predictions. Although R D is a critical parameter, its estimation lacks a standardized methodology that can be applied on outdoor field data. The purpose of this paper is to investigate the impact of time period duration and missing data on R D by analyzing the performance of different techniques applied to synthetic PV system data at different linear R D patterns and known noise conditions. The analysis includes the application of different techniques to a 10-year synthetic dataset of a crystalline Silicon PV system, with emulated degradation levels and imputed missing data. Here, the analysis demonstrated that the accuracy of ordinary least squares (OLS), year-on-year (YOY), autoregressive integrated moving average (ARIMA) and robust principal component analysis (RPCA) techniques is affected by the evaluation duration with all techniques converging to lower R D deviations over the 10-year evaluation, apart from RPCA at high degradation levels. Moreover, the estimated R D is strongly affected by the amount of missing data. Filtering out the corrupted data yielded more accurate R D results for all techniques. It is proven that the application of a change-point detection stage is necessary and guidelines for accurate R D estimation are provided.

14 SOLAR ENERGY↗

Analytical Improvements in PV Degradation Rate Determination

As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined accurately. For non-spectrally corrected data several complete seasonal cycles (typically 3-5 years) are required to obtain reasonably accurate degradation rates. In a rapidly evolving industry such a time span is often unacceptable and the need exists to determine degradation rates accurately in a shorter period of time. Occurrence of outliers and data shifts are two examples of analytical problems leading to greater uncertainty and therefore to longer observation times. In this paper we compare three methodologies of data analysis for robustness in the presence of outliers, data shifts and shorter measurement time periods.

14 SOLAR ENERGY↗

Field Accelerated Stress Testing (FAST): Forecasting Plant-specific Failure Modes and Degradation Rates

Photovoltaic plant owners and insurance companies would like to be prepared for the forthcoming material warranty claims (material defects) and power warranty claims (degradation rate). To address the needs of these stakeholders, this presentation aims to introduce a new conceptual approach to perform accelerated testing right at the field of interest and it is called field accelerated stress testing (FAST). The primary goal of this presentation is to present a conceptual approach to forecast the field specific failure modes and degradation rates in advance by a factor of 2 to 5, right at the plant site using a few spare modules available at the plant location itself.

14 SOLAR ENERGY↗

Data Filtering Impact on PV Degradation Rates and Uncertainty (Poster)

To sustain the commercial success of photovoltaics (PV) it becomes vital to know how power output decreases with time. In order to predict power delivery, degradation rates must be determined accurately. Data filtering, any data treatment assessment of long-term field behavior, is discussed as part of a more comprehensive uncertainty analysis and can be one of the greatest sources of uncertaintyin long-term performance studies. Several distinct filtering methods such as outlier removal and inclusion of only sunny days on several different metrics such as PVUSA, performance ratio, DC power to plane-of-array irradiance ratio, uncorrected, and temperature-corrected were examined. PVUSA showed the highest sensitivity while temperature-corrected power over irradiance ratio was found to bethe least sensitive to data filtering conditions. Using this ratio it is demonstrated that quantification of degradation rates with a statistical accuracy of +/- 0.2%/year within 4 years of field data is possible on two crystalline silicon and two thin-film systems.

14 SOLAR ENERGY↗

Prediction of Potential-Induced Degradation Rate of Thin-Film Modules in the Field Based on Coulombs Transferred

We validated the use of coulombs transferred between the active cell circuit and ground as an index for quantitatively predicting degradation rate in the field for two thin-film module types undergoing potential-induced degradation (PID). The dependence was determined by comparing the degradation rate and leakage current in the field (Cocoa, Florida) to accelerated tests (85 degrees C, 85% relative humidity), both with the application of -1,000 V bias to the cell circuit. The two module types, which degraded about 4% and 11% in power after application of 96 h of bias in chamber, degraded 5% in the field by PID within 200 days and 6 days, respectively. The signatures of PID in the thin-film modules by electroluminescence, photoluminescence, and thermography are shown so that PID in fielded thin-film modules can be identified.

14 SOLAR ENERGY↗

Degradation rates of the AVHRR visible channel for the NOAA 6, 7, and 9 spacecraft

The stability of the AVHRR scanners on board the NOAA 6, 7, and 9 satellites was assessed using the Libian Desert as a target site and a directional reflectance model for determinations of the degradation rates for the channel 1 (0.57-0.69 micron) of the scanners. It was found that the degradation rates determined for 68 months of observations (May 1980-October 1987) were 0, 3.5, and 6.0 percent per year for NOAA 6, 7, and 9, respectively. An analysis based on zonal measurements covering half of the earth's surface showed that these rates are applicable to all surface types and other spacecraft-based earth-viewing scanners subject to shortwave degradation.

Staylor, W. Frank↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2022 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 17 years. The aging environments include elevated temperature up to 250 °F (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models developed previously. Due to differences in containers, 9975 packages with non-3013 containers are only approved for 20 years of storage. The updated degradation models developed in this report have been compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 °F, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of non-conforming conditions such as the presence of excess moisture and mold or beetle infestations.

36 MATERIALS SCIENCE↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Packages in KAC (2021 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 16 years. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 and non3013 containers in storage from 15 years to 20 years. These calculations addressed the potential for degraded fiberboard properties following 20 years in storage using degradation models developed previously. The updated degradation models developed in this report have been compared to the assumptions in these calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 20 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 20 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

14 SOLAR ENERGY↗