Search NASA⌕ Search

SEARCH · Search NASA

Results for “degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Environmental degradation testing of Alloy 709

Alloy 709 is an advanced austenitic stainless steel developed to meet the demanding conditions of sodium fast reactors (SFRs) but may also be of use for lead fast reactors, high temperature gas reactors, and molten salt reactors. Understanding environmental degradation modes and quantifying degradation rates are crucial to ensure the long-term, reliable operation of these reactors. This paper discusses recent neutron irradiation results, future neutron irradiation test plans, and sodium corrosion testing to communicate current best understanding of the performance of Alloy 709 in SFR environments.

A709↗

LSA field test

Degradation tests indicate that electrical degradation is not a slow monotonically increasing phenomenon as originally thought but occurs abruptly as the result of some traumatic event. This finding has led to a change in the test philosophy. A discussion of this change is presented along with a summary of degradation and failure data from all the sites and results from a variety of special tests. New instrumentation for in-field measurements are described. Field testing activity was expanded by the addition of twelve remote sites located as far away as Alaska and the Canal Zone. Descriptions of the new sites are included.

Jaffe, P.↗

Ion-Exchange Membrane-Centric Durability Testing and Degradation Characterization for Industry-Relevant CO 2 Reduction

Electrochemical CO 2 reduction is a promising conversion process for producing value-added fuels and chemicals from electricity and CO 2 as a sustainable carbon feedstock to domestically produce fuels and chemicals from industrial waste. Having reached industrially viable performance metrics with small-scale CO 2 electrolysis cells, the field must now increasingly focus on extending the device durability of large stacks to achieve equivalent metrics for 35,000+ hours to decrease maintenance and capital costs. Reported device lifetimes have increased in recent years, with the longest stability studies for CO, ethylene, and formic acid production being published in 2024–2025 with operation times of 4500, 1000, and 5200 h, respectively. Unfortunately, significant extension of the device durability is still required. Here, we provide an overview of ion-exchange membranes (IEMs) and provide insight into the variety of degradation mechanisms that must be overcome to enable the community to meet durability targets. In an effort to accelerate the extension of device lifetimes, we propose a general approach for characterizing CO 2 electrolysis cell degradation before and after durability testing to better elucidate the mechanisms and failure modes of IEMs in zero-gap cells. Furthermore, we encourage the adoption of operando characterizations in tandem with accelerated stress and durability tests, postulating that their combined applications will be increasingly valuable. We hope that this perspective motivates future durability studies to evaluate degradation across the entire electrolysis cell.

09 BIOMASS FUELS↗

Space Environmental Testing at GSFC

This paper presents an overview of space environmental testing at NASA Goddard Space Flight Center. The contents include: 1) Solar Absorptance measurements; 2) Emittance measurements; 3) Transient Calorimetric Technique; 4) Electrostatic charge testing; 5) UV degradation testing; 6) Solar Wind Facility; and 7) Solar Wind testing.

Kauder, Lonny R.↗

Ultrasonic Clothes Washer/Dryer Combination for Moon, Mars and ISS Applications

Our study aims to investigate the effectiveness of an ultrasonic-based combo garment washing and drying system for space applications. Our system leverages our technological innovations in direct-contact ultrasonic fabric drying in combination with ultrasonic fabric washing. The main objective of this investigation is to gauge the effectiveness of washing & drying textile garments ultrasonically. In this paper, we will report the results of experiments conducted to assess the effectiveness of washing clothes ultrasonically, including ultrasonic intensity testing, stain removal testing, and fabric degradation testing. This study's outcome could lead to the production of an Ultra-Fast Ultrasonic Washer/Dryer Combination unit that could reduce clothing resupply costs for crewed missions to the Moon, Mars, and the ISS.

washer↗

Initial Testing of a Full-Scale Ultrasonic Clothes Washer/Dryer for Moon, Mars, ISS and Beyond

This study investigates the effectiveness of an ultrasonic-based combo garment washing and drying system for space applications. The system leverages our technological innovations in direct-contact ultrasonic fabric drying in combination with ultrasonic fabric washing. The main objective of this investigation is to gauge the effectiveness of washing and drying medium-size T-shirts ultrasonically. This paper will report the results of experiments conducted to assess the effectiveness of washing clothes ultrasonically, including ultrasonic intensity testing, stain removal testing, and fabric degradation testing. The outcome of this study could lead to the design and development of the first ultrasonic clothes washer and dryer for space applications that would reduce clothing resupply costs for crewed missions to the moon, Mars, and micro-gravity space stations.

Crew systems↗

Initial Testing of a Full-Scale Ultrasonic Clothes Washer/Dryer for Moon, Mars, ISS and Beyond

This study investigates the effectiveness of an ultrasonic-based combo garment washing and drying system for space applications. The system leverages our technological innovations in direct-contact ultrasonic fabric drying in combination with ultrasonic fabric washing. The main objective of this investigation is to gauge the effectiveness of washing and drying medium-size T-shirts ultrasonically. This paper will report the results of experiments conducted to assess the effectiveness of washing clothes ultrasonically, including ultrasonic intensity testing, stain removal testing, and fabric degradation testing. The outcome of this study could lead to the design and development of the first ultrasonic clothes washer and dryer for space applications that would reduce clothing resupply costs for crewed missions to the moon, Mars, and micro-gravity space stations.

Crew systems↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally Guided Design of Multiple Impurities Tolerant Electrode (Final Report)

The current project was based on a combined experimental and computational approach, which can help recommend better cathode materials under multiple impurities conditions. The PI will mainly take in charge of experimental and computational thermodynamics of the selected cathode materials for the SOFC applications under multiple impurities. While the co-PI will run the electrochemical tests of the cathodes recommended and eventually the long-term degradation tests. At the end of the project, a multiple tolerant cathode material based on the combined experimental and computational approach will be recommended and the reliability of the commonly used accelerated testing will be evaluated. It will address multiple impurities poisoning effect of SO2, CO2, Cr and H2O on the LSM, LSCF and LNO cathodes by identifying the formation of the detrimental secondary phases by XRD, SEM and TEM techniques. And further recommended cathode material will be subjected to electrochemical testing and the most promising ones will be applied to long-term tests. The hybrid approach the PI proposed will not only be applied to the design of multiple impurities tolerant cathodes but will also be considered in the future oxygen electrode applications in SOECs or reversible SOCs. This hybrid computational and experimental approach includes four sections: 1) Investigation of single impurity poisoning on LSM, LSCF and LNO cathodes in the presence of SO2, CO2, Cr. In this section, LSM, LSCF cathodes from FuelCellMaterials and LNO cathodes from Sol-Gel synthesis will be heat-treated in the above single impurity. And the formation of the secondary phases as well as the corresponding simulations will be cross compared, which shows good agreement between each other. Meanwhile, the accelerated testing approach will be evaluated in these systems compared with the previous published work to understand the reliability of the approach. 2) Investigation of multiple impurities poisoning on LSM, LSCF and LNO cathodes in the presence of Cr+H2O, SO2+Cr and SO2+Cr+H2O conditions. We have also applied these 3 candidate cathodes under these multiple impurities’ conditions and the long-term degradation mechanism of the multiple impurities will be understood with the help of the combined experimental and computational approach. Meanwhile, the synergistic effect of those impurities will be compared with the individual ones in the same cathode system to further reveal the actual operating conditions. 3) Electrochemical testing and polarization of the recommended cathode. We have demonstrated very low polarization resistance in LSCF (core)-LSM (shell) electrodes using MSD process and analyzed impedance spectra using DRT analysis and confirming that the low polarization resistance in LSM infiltrated MSD cells is due to reduction in polarization resistance associated with O2-adsorption process. 4). Long-term degradation testing. We have developed a versatile MSD-based process to deposit various continuous coatings onto porous scaffolds and established baseline for longer term Cr-impurity testing in future projects.

36 MATERIALS SCIENCE↗

Effect of cavitation on fluid stability in polymer thickened fluids and lubricants

The effects of cavitating flow on the polymeric additives used in functional fluids are described. A comparison of thermal and mechanical stability tests for these polymer solutions show distinct differences in the machanism of the polymer degradation. The thermal degradation tests appear to cause an unzippering or depolymerization type of reaction in which there is no particular selectivity based on molecular weight. The mechanical degradation of these fluids appears to be based on molecular weight. Measurements of molecular weight distributions during mechanical degradation show that for a given level of intensity only molecules above a certain minimum size are degraded. The effects of ultrasonic radiation on polymer degradation are reported. Tests were conducted to demonstrate the mechanism of mechanical polymer degradiation in an orifice. A more severe test than the orifice test in which two tapered roller bearings loaded against each other produce the mechanical breakdown is discussed.

Duda, J. L.↗

Mariner 9 Solar Array Design, Manufacture, and Performance

The mission of Mariner 9, the first spacecraft to orbit another planet, was to make scientific observations of the surface of Mars. Throughout this unique mission, the Mariner 9 solar array successfully supported the power requirements of the spacecraft without experiencing anomalies. Basically, the design of the solar array was similar to those of Mariners 6 and 7; however, Mariner 9 had the additional flight operational requirement to perform in a Mars orbit environment mode. The array special tests provided information on the current-voltage characteristics and array space degradation. Tests indicated that total solar array current degradation was 3.5 percent, which could probably be attributed to the gradual degradation of the cover glass and/or the RTV 602 adhesive employed to cement the cover glass to the solar cell.

Sequeira, E. A.↗

Auto-BLAST (AutoBLAST) [SWR-20-93]

Battery life modeling often involves a lot of manual parameter fitting and is not easy for users to adopt the model and use it. To reduce the difficulties for users to adopt battery lifetime models, an automatic battery lifetime modeling analysis and simulation tool suite, Auto-BLAST, has been developed. Auto-BLAST includes a lithium-loss-base life model, a battery electric model, and an algorithm which automatically fits all key parameters in the electric and life models using user provided data. The models and algorithm are packaged into two user-friendly GUIs, Auto-LifeMod, for easy battery life prognostic model fitting and Auto-LifeSim, for easy battery lifetime simulation. The lithium-loss-based life model adopts a similar model framework that models degradations using aging rate models, using battery cycling data to predict battery degradation and expected lifetime. The electric model is an equivalent circuit model which simulates battery voltage responses based on current/power demand profiles. The auto-fitting algorithm uses the user-input data to generate custom battery life model(s). Two GUIs, wrapping around the life model and the auto-fitting algorithm, provide friendly interfaces for users to generate a life model and use it for case study. One GUI requires summary data from accelerated battery life degradation tests as an input and produces battery life models predicting (a) capacity degradation, and (b) resistance growth of the battery. The GUI displays the electrical model response and the input experimental data against the life model predictions with fitted model parameters and fitting error. The GUI also generates an output file to save the fitted model parameters. The second GUI uses the life model from the first GUI and a user-defined battery cycling profile to predict battery lifetime degradation and expected lifetime. Predicted capacity and resistance vs. time are plotted in the GUI and saved to output file. There is a user guide for both GUIs

Mishra, Partha↗

Materials and Processes for New Propulsion Systems with Reduced Environmental Impact

Aeronautics research at NASA Glenn Research Center includes development, characterization and modeling of high temperature, lightweight materials and fabrication processes for aircraft propulsion systems with increased efficiency and reduced emissions, fuel burn and noise. Current propulsion materials research includes Ceramic Matrix Composites and Environmental Barrier Coatings, Polymer Matrix Composites and Additive Manufacturing processes. This presentation will summarize recent progress and plans in these areas. Ceramic Matrix Composites for Turbine Components: As part of NASA's Aeronautics research, Glenn Research Center has developed Ceramic Matrix Composites for 2700 degrees Fahrenheit turbine engine applications in the next generation of ultra-efficient aircraft. In this presentation, the development of advanced fiber and matrix constituents that enabled this advancement will be reviewed, and characterization of the resulting improvements in mechanical properties and durability will be summarized. Progress toward the development and validation of models predicting the effects of the engine environment on durability of Ceramic Matrix Composites and Environmental Barrier Coatings will be summarized. Progress and plans for collaborative research with industry and other government agencies will be reviewed. Polymer Matrix Composites for Powertrain and Impact Protection: A lightweight, hybrid polymer matrix composite/steel gear concept for rotorcraft power transmission applications was evaluated at realistic speed, torque, and power conditions. Dynamic testing was performed at 5000 horsepower and 5400 revolutions per minute with no performance degradation. Test results demonstrated the potential of hybrid composite / metal gears to reduce gear weight by approximately 15 percent, enabling the implementation of multi-speed drive systems, which would otherwise have a weight penalty, for increased speed and efficiency. Results of post-test inspection and endurance tests will be presented. Separately, ballistic impact tests demonstrated improved damage tolerance in polymer matrix composites by incorporating lightweight, thermoplastic veil materials between selected composite plies during the composite fabrication process. Results of impact tests and post-test inspection will be presented. Additive Manufacturing for Electric Propulsion: Additive Manufacturing processes offer the potential to fabricate new, high power density electric motor designs with complex geometries, multi-material components and optimally designed components that would not be feasible with traditional manufacturing processes. High performance stator components using advanced 3-phase conductive coils were fabricated using direct printing with optimized silver pastes. Additional additive manufacturing methods are being used to fabricate rotors and motor housing components. Systems studies show that the higher performance and lower weight motors offer improved energy efficiency and reduced emissions. Improvements to motor performance resulting from optimized materials and component designs will be presented.

Additive Manufacturing↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

Simulated space environment tests on cadmium sulfide solar cells

Cadmium sulfide (Cu2s - CdS) solar cells were tested under simulated space environmental conditions. Some cells were thermally cycled with illumination from a Xenon-arc solar simulator. A cycle was one hour of illumination followed immediately with one-half hour of darkness. In the light, the cells reached an equilibrium temperature of 60 C (333 K) and in the dark the cell temperature dropped to -120 C (153 K). Other cells were constantly illuminated with a Xenon-arc solar simulator. The equilibrium temperature of these cells was 55 C (328 K). The black vacuum chamber walls were cooled with liquid nitrogen to simulate a space heat sink. Chamber pressure was maintained at 0.000001 torr or less. Almost all of the solar cells tested degraded in power when exposed to a simulated space environment of either thermal cycling or constant illumination. The cells tested the longest were exposed to 10.050 thermal cycles.

Clarke, D. R.↗