Search NASA⌕ Search

SEARCH · Search NASA

Results for “degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Environmental degradation testing of Alloy 709

Alloy 709 is an advanced austenitic stainless steel developed to meet the demanding conditions of sodium fast reactors (SFRs) but may also be of use for lead fast reactors, high temperature gas reactors, and molten salt reactors. Understanding environmental degradation modes and quantifying degradation rates are crucial to ensure the long-term, reliable operation of these reactors. This paper discusses recent neutron irradiation results, future neutron irradiation test plans, and sodium corrosion testing to communicate current best understanding of the performance of Alloy 709 in SFR environments.

A709↗

Ion-Exchange Membrane-Centric Durability Testing and Degradation Characterization for Industry-Relevant CO 2 Reduction

Electrochemical CO 2 reduction is a promising conversion process for producing value-added fuels and chemicals from electricity and CO 2 as a sustainable carbon feedstock to domestically produce fuels and chemicals from industrial waste. Having reached industrially viable performance metrics with small-scale CO 2 electrolysis cells, the field must now increasingly focus on extending the device durability of large stacks to achieve equivalent metrics for 35,000+ hours to decrease maintenance and capital costs. Reported device lifetimes have increased in recent years, with the longest stability studies for CO, ethylene, and formic acid production being published in 2024–2025 with operation times of 4500, 1000, and 5200 h, respectively. Unfortunately, significant extension of the device durability is still required. Here, we provide an overview of ion-exchange membranes (IEMs) and provide insight into the variety of degradation mechanisms that must be overcome to enable the community to meet durability targets. In an effort to accelerate the extension of device lifetimes, we propose a general approach for characterizing CO 2 electrolysis cell degradation before and after durability testing to better elucidate the mechanisms and failure modes of IEMs in zero-gap cells. Furthermore, we encourage the adoption of operando characterizations in tandem with accelerated stress and durability tests, postulating that their combined applications will be increasingly valuable. We hope that this perspective motivates future durability studies to evaluate degradation across the entire electrolysis cell.

09 BIOMASS FUELS↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally Guided Design of Multiple Impurities Tolerant Electrode (Final Report)

The current project was based on a combined experimental and computational approach, which can help recommend better cathode materials under multiple impurities conditions. The PI will mainly take in charge of experimental and computational thermodynamics of the selected cathode materials for the SOFC applications under multiple impurities. While the co-PI will run the electrochemical tests of the cathodes recommended and eventually the long-term degradation tests. At the end of the project, a multiple tolerant cathode material based on the combined experimental and computational approach will be recommended and the reliability of the commonly used accelerated testing will be evaluated. It will address multiple impurities poisoning effect of SO2, CO2, Cr and H2O on the LSM, LSCF and LNO cathodes by identifying the formation of the detrimental secondary phases by XRD, SEM and TEM techniques. And further recommended cathode material will be subjected to electrochemical testing and the most promising ones will be applied to long-term tests. The hybrid approach the PI proposed will not only be applied to the design of multiple impurities tolerant cathodes but will also be considered in the future oxygen electrode applications in SOECs or reversible SOCs. This hybrid computational and experimental approach includes four sections: 1) Investigation of single impurity poisoning on LSM, LSCF and LNO cathodes in the presence of SO2, CO2, Cr. In this section, LSM, LSCF cathodes from FuelCellMaterials and LNO cathodes from Sol-Gel synthesis will be heat-treated in the above single impurity. And the formation of the secondary phases as well as the corresponding simulations will be cross compared, which shows good agreement between each other. Meanwhile, the accelerated testing approach will be evaluated in these systems compared with the previous published work to understand the reliability of the approach. 2) Investigation of multiple impurities poisoning on LSM, LSCF and LNO cathodes in the presence of Cr+H2O, SO2+Cr and SO2+Cr+H2O conditions. We have also applied these 3 candidate cathodes under these multiple impurities’ conditions and the long-term degradation mechanism of the multiple impurities will be understood with the help of the combined experimental and computational approach. Meanwhile, the synergistic effect of those impurities will be compared with the individual ones in the same cathode system to further reveal the actual operating conditions. 3) Electrochemical testing and polarization of the recommended cathode. We have demonstrated very low polarization resistance in LSCF (core)-LSM (shell) electrodes using MSD process and analyzed impedance spectra using DRT analysis and confirming that the low polarization resistance in LSM infiltrated MSD cells is due to reduction in polarization resistance associated with O2-adsorption process. 4). Long-term degradation testing. We have developed a versatile MSD-based process to deposit various continuous coatings onto porous scaffolds and established baseline for longer term Cr-impurity testing in future projects.

36 MATERIALS SCIENCE↗

Auto-BLAST (AutoBLAST) [SWR-20-93]

Battery life modeling often involves a lot of manual parameter fitting and is not easy for users to adopt the model and use it. To reduce the difficulties for users to adopt battery lifetime models, an automatic battery lifetime modeling analysis and simulation tool suite, Auto-BLAST, has been developed. Auto-BLAST includes a lithium-loss-base life model, a battery electric model, and an algorithm which automatically fits all key parameters in the electric and life models using user provided data. The models and algorithm are packaged into two user-friendly GUIs, Auto-LifeMod, for easy battery life prognostic model fitting and Auto-LifeSim, for easy battery lifetime simulation. The lithium-loss-based life model adopts a similar model framework that models degradations using aging rate models, using battery cycling data to predict battery degradation and expected lifetime. The electric model is an equivalent circuit model which simulates battery voltage responses based on current/power demand profiles. The auto-fitting algorithm uses the user-input data to generate custom battery life model(s). Two GUIs, wrapping around the life model and the auto-fitting algorithm, provide friendly interfaces for users to generate a life model and use it for case study. One GUI requires summary data from accelerated battery life degradation tests as an input and produces battery life models predicting (a) capacity degradation, and (b) resistance growth of the battery. The GUI displays the electrical model response and the input experimental data against the life model predictions with fitted model parameters and fitting error. The GUI also generates an output file to save the fitted model parameters. The second GUI uses the life model from the first GUI and a user-defined battery cycling profile to predict battery lifetime degradation and expected lifetime. Predicted capacity and resistance vs. time are plotted in the GUI and saved to output file. There is a user guide for both GUIs

Mishra, Partha↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

Enabling Ambient Stability of LiNiO 2 Lithium-Ion Battery Cathode Materials via Graphene–Cellulose Composite Coatings

Nickel-rich layered oxides are widely used as cathode materials for energy-dense lithium-ion batteries. These chemistries, based on the parent compound LiNiO 2 (LNO), are highly sensitive to ambient environments and are known to readily react with moisture and carbon dioxide. As a result, impurities such as lithium hydroxides and lithium carbonates are formed at the LNO surface, compromising electrochemical behavior. Here, we address this issue by coating LNO cathode particles with a hydrophobic barrier layer composed of graphene and ethyl cellulose (GrEC). This coating limits contact between atmospheric moisture and the LNO surface, which minimizes the generation of lithium impurities. This scheme is evaluated by exposing coated LNO to humidified CO 2 for 24 h as an accelerated ambient degradation test. Subsequent spectroscopy, microscopy, and electrochemical characterization show no detectable signatures of carbonates on the LNO surface, thus verifying that the GrEC coating prevents ambient degradation. In conclusion, by demonstrating this methodology for the ultimate nickel-rich chemistry, this approach can likely be generalized to a wide range of ambient-sensitive battery materials.

25 ENERGY STORAGE↗

Lost Circulation Materials in Geothermal Drilling: Thermal Degradation, Viscosity, Compression, and Flow Loop Tests

This dataset provides a set of experimental data on the performance of lost circulation materials (LCMs) used in geothermal drilling operations. It includes results from four distinct tests: thermal degradation, viscosity measurements, compression tests, and high-temperature flow loop experiments. The materials tested, such as cedar fiber, cotton seed hulls, magma fiber, microcellulose, and sawdust, were analyzed under a range of conditions to assess their effectiveness in mitigating fluid losses in geothermal wells. Data on thermal degradation explores mass loss, water loss, and gas release for each material when subjected to temperatures between 90C and 250C. Viscosity measurements capture the behavior of LCM mixtures under different temperatures, while compression tests investigate the structural integrity of both undegraded and thermally degraded materials. The high-temperature flow loop experiments simulate geothermal well conditions, analyzing how different materials and mixtures affect fluid flow and sealing performance in a fractured reservoir environment. In addition to the experimental data, the dataset includes photos documenting the materials, schematics of test setups, and several published manuscripts that provide detailed insights into the experimental methods and findings.

15 GEOTHERMAL ENERGY↗

Collaborative R&D with REEL Solar Inc (REEL) to Understand and Overcome Performance Limitations in CdTe Solar Cells: Cooperative Research and Development (Final Report)

This CRADA will focus on processing, advanced characterization, and testing of photovoltaic materials and devices to understand and improve REEL CdTe solar technology. This will include examining process variations and different buffer, absorber, and contact layers from REEL and NLR to maximize performance. The unique and diverse advanced characterization tools at NLR, such as time-resolved photoluminescence, capacitance-voltage measurements, electron beam scattered diffraction, cathodoluminescence, electron microscopy, TOF-SIMS, and other measurements will be applied to characterize REEL processing to improve understanding and guide experimental directions. Accelerated stability and potential induced degradation tests will be used to analyze metastability, short-and-long term degradation, and improve bankability. A second and major thrust this period will be joint development of Si/CdTe tandem solar cells to overcome industry wide terrestrial solar efficiency limits with the two lowest cost and manufacturable solar materials today. This will include developing novel transparent back contacts that can be incorporated into tandem structures and other novel solar applications, detailed analysis of designs and configurations for CdTe/Si tandem modules, and prototyping REEL CdTe Technology with Si bottom cells in tandem structures.

14 SOLAR ENERGY↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

Multi-Messenger In-situ Tolerance Optimization of Mixed Perovskite Photovoltaics. Final Report

The main objectives for this project were to formulate, validate and disseminate a new procedure based on Environmental X-ray Photoelectron Spectroscopy (EXPS) for the accelerated degradation testing of metal hybrid perovskite (MHP) PV materials. With this capability, we can aid US efforts to improve MHP tolerance for illumination in damp heat conditions. This capability will benefit the public by supporting new industry efforts to create stable MHP formulations.

14 SOLAR ENERGY↗

Intermediate-Term Thermal Aging Effect Evaluation for Grade 92 and 316L at The LWR Relevant Temperature

Life extension of the existing nuclear reactors imposes accumulated damages, such as higher fluences and longer period of corrosion, to structural materials, which would result in significant challenges to the traditional reactor materials such as type 304 and 316 stainless steels. Advanced alloys with superior radiation resistance will increase safety margins, design flexibility, and economics for not only the life extension of the existing fleet but also new builds with advanced reactor designs. The Electric Power Research Institute (EPRI) teamed up with Department of Energy (DOE) on the Advanced Radiation Resistant Materials (ARRM) program, aiming to develop and test degradation resistant alloys from current commercial alloy specifications by 2021 to a new advanced alloy with superior degradation resistance in light water reactor (LWR)-relevant environments by 2024. Based on a comprehensive microstructure and property screening performed in Phase-1 of the ARRM program, a total of five alloys, together with 316L and X-750 as references, were down-selected for Phase-2 neutron irradiation studies. Because thermal aging could exert a synergistic effect on neutron irradiation due to the low neutron damage rate on the order of 10 –7 displacements per atom per second (dpa/s), Grade 92 (one of the five down-selected alloys) and two heats of 316L were selected in this task to study the effect of aging at 350°C for 12.5–12.7 kh on microstructure and mechanical properties. The aging time is approximately corresponding to 5 dpa neutron irradiation, which can be served as a reference for the 5-dpa-irradiated samples of the alloys to help understand the independent neutron damage influence on microstructure and mechanical properties. Optical microscopy and scanning electron microscopy were used for microstructural characterization. Hardness, tensile, Charpy impact toughness, and fracture toughness in the ductile regime of the aged samples were examined. The aging of Grade 92 led to the formation of many Laves phase in sizes of ~100–200 nm and resulted in some reduction in hardness and yield/ultimate tensile strength with some increases in uniform and total plastic elongations, which may have helped the enhancement of Charpy impact toughness, e.g., ~4 J increase in upper-shelf energy and 20.5°C reduction in ductile-brittle transition temperature compared with the unaged condition. The fracture toughness of the aged Grade 92 showed decent toughness of ~303 MPa√m (K Jq ) with ~87 tearing modulus at 22°C, which reduced to ~241 MPa√m (~20% reduction) with ~75 tearing modulus at 300°C. The two heats of 316L are differentiated by their amounts of δ-ferrite, i.e., ~1 vol% in heat T1103 and ~4 vol% in heat N5B8. The two heats of 316L were subjected to 15% cold work (CW) as this condition is often used in nuclear reactors to help trapping radiation-induced defects and thus postpone the steady state swelling stage. The aging did not result in any noticeable microstructure changes, except for possible segregations at grain boundaries that need to be further investigated. The aging resulted in slight reduction in hardness of 316L-T1103 and slight increase in hardness of 316L-N5B8, which is consistent with their tensile testing results. The 15%CW might have introduced some inhomogeneity, resulting in large standard deviations in hardness, which were reduced after the aging. The aged 316L followed the same trend as the unaged condition for the strength and elongation results from the tensile testing. Minimum elongations appeared within ~300–600°C, above which the elongations seem to increase. Unlike the negligible or minor changes in microstructure, hardness and tensile results of the two heats of 316L, their fracture toughness showed noticeable difference. The aged 316L-T1103 showed good toughness of ~350 MPa√m with ~80 tearing modulus at 22°C, which reduced to ~271 MPa√m (~23% reduction) with ~83 tearing modulus at 300°C. In contrast, the aged 316L-N5B8 showed lower toughness of ~244 MPa√m with ~53 tearing modulus at 22°C, which reduced to ~180 MPa√m (~26% reduction) with ~31 tearing modulus at 300°C. The preliminary results indicate that the presence of high volume of δ-ferrite would noticeable impair fracture toughness although it may not influence hardness and tensile properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding Degradation Mechanisms in SrIrO 3 Oxygen Evolution Electrocatalysts: Chemical and Structural Microscopy at the Nanoscale

Designing acid-stable oxygen evolution reaction electrocatalysts is key to developing sustainable energy technologies such as polymer electrolyte membrane electrolyzers but has proven challenging due to the high applied anodic potentials and corrosive electrolyte. This work showcases advanced nanoscale microscopy techniques supported by complementary structural and chemical characterization to develop a fundamental understanding of stability in promising SrIrO 3 thin film electrocatalyst materials. Cross-sectional high-resolution transmission electron microscopy illustrates atomic-scale bulk and surface structure, while secondary ion mass spectrometry imaging using a helium ion microscope provides the nanoscale lateral elemental distribution at the surface. After accelerated degradation tests under anodic potential, the SrIrO 3 film thins and roughens, but the lateral distribution of Sr and Ir remains homogeneous. A layer-wise dissolution mechanism is hypothesized, wherein anodic potential causes the IrO x -rich surface to dissolve and be regenerated by Sr leaching. Finally, the characterization approaches utilized herein and mechanistic insights into SrIrO 3 are translatable to a wide range of catalyst systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗