Search NASA⌕ Search

SEARCH · Search NASA

Results for “density maps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rapid chain tracing of polypeptide backbones in electron-density maps

A method for rapid chain tracing of polypeptide backbones at moderate resolution is presented. A method for the rapid tracing of polypeptide backbones has been developed. The method creates an approximate chain tracing that is useful for visual evaluation of whether a structure has been solved and for use in scoring the quality of electron-density maps. The essence of the method is to (i) sample candidate C{sup α} positions at spacings of approximately 0.6 Å along ridgelines of high electron density, (ii) list all possible nonapeptides that satisfy simple geometric and density criteria using these candidate C{sup α} positions, (iii) score the nonapeptides and choose the highest scoring ones, and (iv) find the longest chains that can be made by connecting nonamers. An indexing and storage scheme that allows a single calculation of most distances and density values is used to speed up the process. The method was applied to 42 density-modified electron-density maps at resolutions from 1.5 to 3.8 Å. A total of 21 428 residues in these maps were traced in 24 CPU min with an overall r.m.s.d. of 1.61 Å for C{sup α} atoms compared with the known refined structures. The method appears to be suitable for rapid evaluation of electron-density map quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid model building of β-sheets in electron-density maps

A method for rapid model building of β-sheets at moderate resolution is presented. A method for rapidly building β-sheets into electron-density maps is presented. β-Strands are identified as tubes of high density adjacent to and nearly parallel to other tubes of density. The alignment and direction of each strand are identified from the pattern of high density corresponding to carbonyl and C{sup β} atoms along the strand averaged over all repeats present in the strand. The β-strands obtained are then assembled into a single atomic model of the β-sheet regions. The method was tested on a set of 42 experimental electron-density maps at resolutions ranging from 1.5 to 3.8 Å. The β-sheet regions were nearly completely built in all but two cases, the exceptions being one structure at 2.5 Å resolution in which a third of the residues in β-sheets were built and a structure at 3.8 Å in which under 10% were built. The overall average r.m.s.d. of main-chain atoms in the residues built using this method compared with refined models of the structures was 1.5 Å.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid model building of α-helices in electron-density maps

A method for rapid model building of α-helices at moderate resolution is presented. A method for the identification of α-helices in electron-density maps at low resolution followed by interpretation at moderate to high resolution is presented. Rapid identification is achieved at low resolution, where α-helices appear as tubes of density. The positioning and direction of the α-helices is obtained at moderate to high resolution, where the positions of side chains can be seen. The method was tested on a set of 42 experimental electron-density maps at resolutions ranging from 1.5 to 3.8 Å. An average of 63% of the α-helical residues in these proteins were built and an average of 76% of the residues built matched helical residues in the refined models of the proteins. The overall average r.m.s.d. between main-chain atoms in the modeled α-helices and the nearest atom with the same name in the refined models of the proteins was 1.3 Å.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Galaxy bias from the Dark Energy Survey Science Verification data: Combining galaxy density maps and weak lensing maps

We measure the redshift evolution of galaxy bias for a magnitude-limited galaxy sample by combining the galaxy density maps and weak lensing shear maps for a ~116 deg 2 area of the Dark Energy Survey (DES) Science Verification (SV) data. This method was first developed in Amara et al. and later re-examined in a companion paper with rigorous simulation tests and analytical treatment of tomographic measurements. In this work we apply this method to the DES SV data and measure the galaxy bias for a i < 22.5 galaxy sample. We find the galaxy bias and 1σ error bars in four photometric redshift bins to be 1.12 ± 0.19 (z = 0.2–0.4), 0.97 ± 0.15 (z = 0.4–0.6), 1.38 ± 0.39 (z = 0.6–0.8), and 1.45 ± 0.56 (z = 0.8–1.0). These measurements are consistent at the 2σ level with measurements on the same data set using galaxy clustering and cross-correlation of galaxies with cosmic microwave background lensing, with most of the redshift bins consistent within the 1σ error bars. In addition, our method provides the only σ8 independent constraint among the three. We forward model the main observational effects using mock galaxy catalogues by including shape noise, photo-z errors, and masking effects. We show that our bias measurement from the data is consistent with that expected from simulations. With the forthcoming full DES data set, we expect this method to provide additional constraints on the galaxy bias measurement from more traditional methods. Moreover, in the process of our measurement, we build up a 3D mass map that allows further exploration of the dark matter distribution and its relation to galaxy evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AlignOT: An Optimal Transport Based Algorithm for Fast 3D Alignment With Applications to Cryogenic Electron Microscopy Density Maps

Aligning electron density maps from Cryogenic electron microscopy (cryo-EM) is a first key step for studying multiple conformations of a biomolecule. As this step remains costly and challenging, with standard alignment tools being potentially stuck in local minima, we propose here a new procedure, called AlignOT, which relies on the use of computational optimal transport (OT) to align EM maps in 3D space. By embedding a fast estimation of OT maps within a stochastic gradient descent algorithm, our method searches for a rotation that minimizes the Wasserstein distance between two maps, represented as point clouds. Here, we quantify the impact of various parameters on the precision and accuracy of the alignment, and show that AlignOT can outperform the standard local alignment methods, with an increased range of rotation angles leading to proper alignment. We further benchmark AlignOT on various pairs of experimental maps, which account for different types of conformational heterogeneities and geometric properties. As our experiments show good performance, we anticipate that our method can be broadly applied to align 3D EM maps.

3D alignment↗

CryoTEN: efficiently enhancing cryo-EM density maps using transformers

Abstract Motivation Cryogenic electron microscopy (cryo-EM) is a core experimental technique used to determine the structure of macromolecules such as proteins. However, the effectiveness of cryo-EM is often hindered by the noise and missing density values in cryo-EM density maps caused by experimental conditions such as low contrast and conformational heterogeneity. Although various global and local map-sharpening techniques are widely employed to improve cryo-EM density maps, it is still challenging to efficiently improve their quality for building better protein structures from them. Results In this study, we introduce CryoTEN—a 3D UNETR++ style transformer to improve cryo-EM maps effectively. CryoTEN is trained using a diverse set of 1295 cryo-EM maps as inputs and their corresponding simulated maps generated from known protein structures as targets. An independent test set containing 150 maps is used to evaluate CryoTEN, and the results demonstrate that it can robustly enhance the quality of cryo-EM density maps. In addition, automatic de novo protein structure modeling shows that protein structures built from the density maps processed by CryoTEN have substantially better quality than those built from the original maps. Compared to the existing state-of-the-art deep learning methods for enhancing cryo-EM density maps, CryoTEN ranks second in improving the quality of density maps, while running >10 times faster and requiring much less GPU memory than them. Availability and implementation The source code and data are freely available at https://github.com/jianlin-cheng/cryoten.

Biochemistry & Molecular Biology↗

De novo atomic protein structure modeling for cryoEM density maps using 3D transformer and HMM

Accurately building 3D atomic structures from cryo-EM density maps is a crucial step in cryo-EM-based protein structure determination. Converting density maps into 3D atomic structures for proteins lacking accurate homologous or predicted structures as templates remains a significant challenge. Here, we introduce Cryo2Struct, a fully automated de novo cryo-EM structure modeling method. Cryo2Struct utilizes a 3D transformer to identify atoms and amino acid types in cryo-EM density maps, followed by an innovative Hidden Markov Model (HMM) to connect predicted atoms and build protein backbone structures. Cryo2Struct produces substantially more accurate and complete protein structural models than the widely used ab initio method Phenix. Additionally, its performance in building atomic structural models is robust against changes in the resolution of density maps and the size of protein structures.

59 BASIC BIOLOGICAL SCIENCES↗

Cryo2StructData: A Large Labeled Cryo-EM Density Map Dataset for AI-based Modeling of Protein Structures

The advent of single-particle cryo-electron microscopy (cryo-EM) has brought forth a new era of structural biology, enabling the routine determination of large biological molecules and their complexes at atomic resolution. The high-resolution structures of biological macromolecules and their complexes significantly expedite biomedical research and drug discovery. However, automatically and accurately building atomic models from high-resolution cryo-EM density maps is still time-consuming and challenging when template-based models are unavailable. Artificial intelligence (AI) methods such as deep learning trained on limited amount of labeled cryo-EM density maps generate inaccurate atomic models. To address this issue, we created a dataset called Cryo2StructData consisting of 7,600 preprocessed cryo-EM density maps whose voxels are labelled according to their corresponding known atomic structures for training and testing AI methods to build atomic models from cryo-EM density maps. Cryo2StructData is larger than existing, publicly available datasets for training AI methods to build atomic protein structures from cryo-EM density maps. We trained and tested deep learning models on Cryo2StructData to validate its quality showing that it is ready for being used to train and test AI methods for building atomic models.

59 BASIC BIOLOGICAL SCIENCES↗

An Atlas-Based Electron Density Mapping Method for Magnetic Resonance Imaging (MRI)-Alone Treatment Planning and Adaptive MRI-Based Prostate Radiation Therapy

Purpose: Prostate radiation therapy dose planning directly on magnetic resonance imaging (MRI) scans would reduce costs and uncertainties due to multimodality image registration. Adaptive planning using a combined MRI-linear accelerator approach will also require dose calculations to be performed using MRI data. The aim of this work was to develop an atlas-based method to map realistic electron densities to MRI scans for dose calculations and digitally reconstructed radiograph (DRR) generation. Methods and Materials: Whole-pelvis MRI and CT scan data were collected from 39 prostate patients. Scans from 2 patients showed significantly different anatomy from that of the remaining patient population, and these patients were excluded. A whole-pelvis MRI atlas was generated based on the manually delineated MRI scans. In addition, a conjugate electron-density atlas was generated from the coregistered computed tomography (CT)-MRI scans. Pseudo-CT scans for each patient were automatically generated by global and nonrigid registration of the MRI atlas to the patient MRI scan, followed by application of the same transformations to the electron-density atlas. Comparisons were made between organ segmentations by using the Dice similarity coefficient (DSC) and point dose calculations for 26 patients on planning CT and pseudo-CT scans. Results: The agreement between pseudo-CT and planning CT was quantified by differences in the point dose at isocenter and distance to agreement in corresponding voxels. Dose differences were found to be less than 2%. Chi-squared values indicated that the planning CT and pseudo-CT dose distributions were equivalent. No significant differences (p > 0.9) were found between CT and pseudo-CT Hounsfield units for organs of interest. Mean {+-} standard deviation DSC scores for the atlas-based segmentation of the pelvic bones were 0.79 {+-} 0.12, 0.70 {+-} 0.14 for the prostate, 0.64 {+-} 0.16 for the bladder, and 0.63 {+-} 0.16 for the rectum. Conclusions: The electron-density atlas method provides the ability to automatically define organs and map realistic electron densities to MRI scans for radiotherapy dose planning and DRR generation. This method provides the necessary tools for MRI-alone treatment planning and adaptive MRI-based prostate radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Ensemble Refinement of Protein Structures in High Resolution Electron Microscopy Density Maps with Radical Augmented Molecular Dynamics Flexible Fitting

Recent advances in cryo-electron microscopy (cryo-EM) have enabled modeling macromolecular complexes that are essential components of the cellular machinery. The density maps derived from cryo-EM experiments are often integrated with manual, knowledge or artificial intelligence driven, and physics-guided computational methods to build, fit, and refine molecular structures. Going beyond a single stationary- structure determination scheme, it is becoming more common to interpret the experimental data with an ensemble of models, which contributes to an average observation. Hence, there is a need to decide on the quality of an ensemble of protein structures on-the-fly, while refining them against the density maps. Here, we introduce such an adaptive decision making scheme during the molecular dynamics flexible fitting (MDFF) of biomolecules. Using RADICAL-Cybertools, and the new RADICAL augmented MDFF implementation (R-MDFF) is examined in high-performance computing environments for refinement of two protein systems, Adenylate Kinase and Carbon Monoxide Dehydrogenase. For the test cases, use of multiple replicas in flexible fitting with adaptive decision making in R-MDFF improves the overall correlation to the density by 40% relative to the refinements of the brute-force MDFF. The improvements are particularly significant at high, 2 - 3 Å, map resolutions. More importantly, the ensemble model captures key features of biologically relevant molecular dynamics that is inaccessible to a single-model interpretation. Finally, the pipeline is applicable to systems of growing sizes, which is demonstrated using ensemble refinement of capsid proteins from Chimpanzee adenovirus. The overhead for decision making remaining low and robust to computing environments. The software is publicly available on GitHub and includes a short user guide to install the R-MDFF on different computing environments, from local Linux based workstations to High Performance Computing (HPC) environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracing Actin Filament Bundles in Three-Dimensional Electron Tomography Density Maps of Hair Cell Stereocilia

Cryo-electron tomography (cryo-ET) is a powerful method of visualizing the three-dimensional organization of supramolecular complexes, such as the cytoskeleton, in their native cell and tissue contexts. Due to its minimal electron dose and reconstruction artifacts arising from the missing wedge during data collection, cryo-ET typically results in noisy density maps that display anisotropic XY versus Z resolution. Molecular crowding further exacerbates the challenge of automatically detecting supramolecular complexes, such as the actin bundle in hair cell stereocilia. Stereocilia are pivotal to the mechanoelectrical transduction process in inner ear sensory epithelial hair cells. Given the complexity and dense arrangement of actin bundles, traditional approaches to filament detection and tracing have failed in these cases. In this study, we introduce BundleTrac, an effective method to trace hundreds of filaments in a bundle. A comparison between BundleTrac and manually tracing the actin filaments in a stereocilium showed that BundleTrac accurately built 326 of 330 filaments (98.8%), with an overall cross-distance of 1.3 voxels for the 330 filaments. BundleTrac is an effective semi-automatic modeling approach in which a seed point is provided for each filament and the rest of the filament is computationally identified. We also demonstrate the potential of a denoising method that uses a polynomial regression to address the resolution and high-noise anisotropic environment of the density map.

stereocilia↗

Shell stability and conditions analyzed using a new method of extracting shell areal density maps from spectrally resolved images of direct-drive inertial confinement fusion implosions

In warm target direct-drive ICF implosion experiments performed at the OMEGA laser facility, plastic microballoons doped with a titanium tracer layer in the shell and filled with deuterium gas were imploded using a low-adiabat shaped laser pulse. Continuum radiation emitted in the core is transmitted through the tracer layer and the resulting spectrum recorded with a gated multi-monochromatic x-ray imager (MMI). Titanium K-shell line absorption spectra observed in the data are due to transitions in L-shell titanium ions driven by the backlighting continuum. The MMI data consist of an array of spectrally resolved images of the implosion. These 2-D space-resolved titanium spectral features constrain the plasma conditions and areal density of the titanium doped region of the shell. The MMI data were processed to obtain narrow-band images and space resolved spectra of titanium spectral features. Shell areal density maps, ρL(x,y), extracted using a new method using both narrow-band images and space resolved spectra are confirmed to be consistent within uncertainties. We report plasma conditions in the titanium-doped region of electron temperature (T e ) = 400±28eV, electron number density (N e ) = 8.5x10 24 ±2.5x10 24 cm -3 , and average areal density <ρR> = 86±7mg/cm 2 . Fourier analysis of areal density maps reveals shell modulations caused by hydrodynamic instability growth near the fuel-shell interface in the deceleration phase. We observe significant structure in modes l = 2-9, dominated by l = 2. We extract a target breakup fraction of 7.1±1.5% from our Fourier analysis. A new method for estimating mix width is evaluated against existing literature and our target breakup fraction. We estimate a mix width of 10.5±1μm.

42 ENGINEERING↗

SU-E-J-233: Effect of Brachytherapy Seed Artifacts in T2 and Proton Density Maps in MR Images

Purpose: This study aims at investigating the influence of brachytherapy seeds on T2 and proton density (PD) maps generated from MR images. Proton density maps can be used to extract water content. Since dose absorbed in tissue surrounding low energy brachytherapy seeds are highly influenced by tissue composition, knowing the water content is a first step towards implementing a heterogeneity correction algorithm using MR images. Methods: An LDR brachytherapy (IsoAid Advantage Pd-103) seed was placed in the middle of an agar-based gel phantom and imaged using a 3T Philips MR scanner with a 168-channel head coil. A multiple echo sequence with TE=20, 40, 60, 80, 100 (ms) with large repetition time (TR=6259ms) was used to extract T2 and PD maps. Results: Seed artifacts were considerably reduced on T2 maps compared to PD maps. The variation of PD around the mean was obtained as −97% to 125% (±1%) while for T2 it was recorded as −71% to 24% (±1%). Conclusion: PD maps which are required for heterogeneity corrections are susceptible to artifacts from seeds. Seed artifacts on T2 maps, however, are significantly reduced due to not being sensitive to B0 field variation.

60 APPLIED LIFE SCIENCES↗