Search NASA⌕ Search

SEARCH · Search NASA

Results for “design coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multilevel Analysis, Design, and Modeling of Coupling Advanced Nuclear Reactors and Thermal Energy Storage in an Integrated Energy System

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (A LWR), a high-temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state and transient-state operation with minimum disruption to the nuclear power cycle. This first part of the study presents steady-state models developed using Aspen HYSYS®, with the thermal energy bypass for NPP-TES coupling being varied at up to 50%. The various components were sized using the Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The TES-coupled A-NPP steady-state models and cost functions then provided a baseline for dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools. A stochastic optimization of the various energy storage systems coupled to the A-NPPs was then performed using the Risk Analysis Virtual Environment (RAVEN) and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON). The signal processing and synthetic history capabilities of RAVEN were used to account for the unpredictable behavior of electricity markets. An autoregressive moving average (ARMA) model was used to analyze price signals from the Pennsylvania-New Jersey-Maryland (PJM) market and were applied to the HERON analysis in order to optimize a system with the best economics. Transient modeling evaluation was then performed using Modelica models within the HYBRID repository, which was developed at INL for the Department of Energy Integrated Energy Systems program for the characterization of dynamic integrated system behavior and feedback. This includes evaluation of the TES-coupled A-LWR systems’ impact on physical and thermal system response during imposed system demands. Additional TES-coupled reactor types, coupling approaches, markets, and TES technologies will be evaluated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wind Turbine Rotor Design Using High-Fidelity Aerostructural Optimization

Large wind turbines yield more energy but demand careful aeroelastic blade design. Coupled multiphysics design strategies can reduce wind energy costs by exploiting fluid-structure interactions. This work presents the first high-fidelity aerostructural optimization study of a large wind turbine rotor. We use blade-resolved fluid dynamics and structural solvers in a monolithic gradient-based optimization framework to explore steady-state torque and blade mass tradeoffs. The coupled-adjoint approach computes gradients efficiently, enabling the optimization of over 100 structural and geometric parameters simultaneously. Our optimization study modifies a DTU 10 MW benchmark with a simplified structure and isotropic material properties. The tightly coupled optimizations increase torque by 14% while reducing rotor mass by 9% or reduce blade mass by 27% while maintaining torque. Blade-resolved models provide greater design freedom, enabling 5% higher mass reductions than conventional parameterizations at equal torque. This framework paves the way for more detailed high-fidelity optimization studies to complement conventional design approaches.

17 WIND ENERGY↗

Fully depleted charge‐coupled device design and technology development

Abstract We describe the advancement of fully depleted charge‐coupled device (CCD) technology for scientific applications. Recent efforts on 650–725 m‐thick CCDs for direct dark‐matter and radiation detection with single‐electron sensitivity are described, as well as the technology transfer of the fully depleted CCD technology to 200 mm‐wafer fabrication facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Enabling Floating Offshore VAWT Design by Coupling OWENS and OpenFAST

Vertical-axis wind turbines (VAWTs) have a long history, with a wide variety of turbine archetypes that have been designed and tested since the 1970s. While few utility-scale VAWTs currently exist, the placement of the generator near the turbine base could make VAWTs advantageous over tradition horizontal-axis wind turbines for floating offshore wind applications via reduced platform costs and improved scaling potential. However, there are currently few numerical design and analysis tools available for VAWTs. One existing engineering toolset for aero-hydro-servo-elastic simulation of VAWTs is the Offshore Wind ENergy Simulator (OWENS), but its current modeling capability for floating systems is non-standard and not ideal. This article describes how OWENS has been coupled to several OpenFAST modules to update and improve modeling of floating offshore VAWTs and discusses the verification of these new capabilities and features. The results of the coupled OWENS verification test agree well with a parallel OpenFAST simulation, validating the new modeling and simulation capabilities in OWENS for floating VAWT applications. These developments will enable the design and optimization of floating offshore VAWTs in the future.

17 WIND ENERGY↗

3.5 kW/in3 Planar Coupled Inductor Design and Optimization for a 50 kW 3-level Four-Switch Buck-Boost (3L-FSBB) Converter

Planar magnetics design has been widely used in power electronics field because of the low profile, ease of manufacturability, and high power density. This paper first proposes a 3-level four-switch buck-boost (3L-FSBB) converter for the dc-dc applications where the zero common-mode (CM) voltage emissions, step-up and step-down are all required. With the consideration of power density, efficiency, and cost, a 15oz heavy copper coupled inductor for 3-level FSBB converter was designed and optimized with the low-cost commercial core and planar windings. According to the soft-switching quadrangle modulation for 3-L FSBB, the turns number and stacked core number are optimized first. And then, a two-board design is proposed to reduce the fringing effect and improve the thermal performance. Finally, a 75 kVA two-stage ac-dc-dc converter including a 3-level FSBB converter was built to verify the electrical design.

Cao, Yuliang↗

De novo design of transmembrane β barrels

Transmembrane β-barrel proteins (TMBs) are of great interest for single-molecule analytical technologies because they can spontaneously fold and insert into membranes and form stable pores, but the range of pore properties that can be achieved by repurposing natural TMBs is limited. We leverage the power of de novo computational design coupled with a “hypothesis, design, and test” approach to determine TMB design principles, notably, the importance of negative design to slow β-sheet assembly. We design new eight-stranded TMBs, with no homology to known TMBs, that insert and fold reversibly into synthetic lipid membranes and have nuclear magnetic resonance and x-ray crystal structures very similar to the computational models. These advances should enable the custom design of pores for a wide range of applications.

Vorobieva, Anastassia A.↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Multi-Monochromatic X-ray Imager (MMI) for Kr K-shell line emission

We report the Multi-Monochromatic X-ray Imager (MMI) is a time-gated spectrometer used in implosion experiments at the OMEGA laser facility. From the data, electron temperature and density spatial distributions can be obtained at different implosion times. Previous MMI designs used Ar K-shell emission (3–6 keV) as a spectroscopic tracer and provided a spectral resolution of around 20 eV. However, Ar K-shell line emission becomes less useful at electron temperatures above 2 keV due to over-ionization. Kr K-shell (12–16 keV) has been shown to be an attractive alternative to diagnose hot implosion cores in recent publications. The purpose of this paper is to show a new point design that allows the MMI to detect this higher photon energy range with suitable spectral resolution. The algorithm used to find the optimal design couples a ray-tracing code and an exhaustive parameter space search. This algorithm may be useful as a tool to find optimal MMI designs for other purposes, i.e., other spectral regions for other spectroscopic tracers. So, the main change between the two designs is the replacement of the multi-layer mirror with a flat Bragg Ge (220) crystal. The final Kr K-shell MMI design has a photon energy range from 12 to 16.1 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Unified Beam-Dynamics and Hardware Design Framework for Hybrid Nonlinear-Kicker Injection in NSLS-II

Nonlinear kickers (NLKs) enable off-axis injection in ultralow-emittance storage rings by providing a strong kick to the injected beam while remaining nearly transparent to the stored beam. In hybrid schemes, a conventional four-kicker bump defines the injected trajectory, and the NLK reduces the first-turn action under constrained beam offset and optics conditions. Effective operation additionally requires stable and reproducible first-turn injection trajectories. We develop a compact action–angle framework that expresses NLK dynamics in terms of Courant–Snyder invariants and yields an analytical bound on achievable action reduction. This formulation provides direct design rules for NLK placement, phase advance, injected-beam offset, and kicker field profile. Within this framework, we identify the 8-wire NLK as a practical baseline and extend its design by relaxing the square-geometry constraint, enabling inward shifting of the off-axis field peak while preserving on-axis field and gradient cancellation. Application to the NSLS-II lattice shows how aperture, pulsed-power, and mechanical constraints combine to determine a coupled design solution. Multi-turn tracking confirms that candidate NLK locations maintain sufficient stay-clear (aperture-clearance) margin, while the optimized wire geometry reduces the required current and Lorentz force load. The results establish a unified approach for NLK-assisted injection design and provide a practical pathway for upgrades in diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

A Techno-Economic Analysis of a 50MWth Light-Trapping Cavity-Planar Solar Receiver Tower Capital Expenditures and its Cost Mitigation Strategies

To maximize thermal efficiency, the National Renewable Energy Laboratory (NREL) has proposed a light-trapping cavity-planar receiver design intended to capture energy from reradiating surfaces. This system implements a macroscale light trapping mechanism induced by panels with triangular channels, this mechanism allows for elevated temperatures on the receiver panels and in turn the temperature of the HTF; using this design coupled with the implementation of a fluidized particle flow as the HTF, it can be expected for some components to reach a peak working temperature of nearly 1000 degrees C cyclically throughout each day-night cycle. While these temperatures correlate to higher efficiency of the CSP tower they also demand intense thermomechanical properties from the materials used to make the receiver panels. In this analysis, we will list our assumptions to provide clarity on the significance of our calculation. This cost analysis will be conducted using a combination of both case study data and surveying industry to determine costs that are relevant to the current market trends. This analysis represents an early attempt to establish the Capital Expenditures required for a CSP tower of such design to determine the feasibility of implementing such a system in the industry.

concentrated solar power (CSP)↗

Coupling Anionic Oxygen Redox with Selenium for Stable High‐Voltage Sodium Layered Oxide Cathodes

Utilizing anion redox reaction is crucial for developing the next generation of high-energy density, low-cost sodium-ion batteries. However, the irreversible oxygen redox reaction in Na-ion layered cathodes, which leads to voltage fading and reduced overall lifespan, has hindered their practical application. In this study, selenium is incorporated as a synergistic redox active center of oxygen to improve the stability of Na-ion cathodes. The redesigned cathode maintains stable voltage by demonstrating reversible oxygen redox while significantly suppressing the redox activity of manganese. The anionic redox contribution capacity of the selenium-doped Na 0.6 Li 0.2 Mn 0.8 O 2 cathode remains as high as 84% after 50 cycles, while the pristine Na 0.6 Li 0.2 Mn 0.8 O 2 cathode experiences a reduction to 39% of its initial capacity. The X-ray photoelectron spectroscopy data and computational analysis further revealed that selenium doping participates in redox as Se +4/5 which stabilizes the charged state and increases the energy step for O─O dimerization, thus improving the stability and lifespan of Na 0.6 Li 0.2 Mn 0.8 O 2 cathodes. In conclusion, the findings highlight the potential of redox coupling design to address the issue of voltage fade caused by irreversible anionic redox.

25 ENERGY STORAGE↗

Unblocking Oxygen Charge Compensation for Stabilized High‐Voltage Structure in P2‐Type Sodium‐Ion Cathode

Abstract Layered transition‐metal (TM) oxides are ideal hosts for Li + charge carriers largely due to the occurrence of oxygen charge compensation that stabilizes the layered structure at high voltage. Hence, enabling charge compensation in sodium layered oxides is a fascinating task for extending the cycle life of sodium‐ion batteries. Herein a Ti/Mg co‐doping strategy for a model P2‐Na 2/3 Ni 1/3 Mn 2/3 O 2 cathode material is put forward to activate charge compensation through highly hybridized O 2 p TM 3 d covalent bonds. In this way, the interlayer OO electrostatic repulsion is weakened upon deeply charging, which strongly affects the systematic total energy that transforms the striking P2–O2 interlayer contraction into a moderate solid‐solution‐type evolution. Accordingly, the cycling stability of the codoped cathode material is improved superiorly over the pristine sample. This study starts a perspective way of optimizing the sodium layered cathodes by rational structural design coupling electrochemical reactions, which can be extended to widespread battery researches.

25 ENERGY STORAGE↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗

Accounting for Sustainability and Performance: Contrasting Effects of PET-Derived Modifiers on Asphalt Durability

The valorization of waste plastics in roadway infrastructure requires careful balance between sustainability and performance, as ineffective modifiers may incur both environmental and financial costs. This study shows that two modifiers derived from the same waste plastic source (PET)-DOTP (N1,N4-(dioctyl)terephthalamide) and HETP (N1,N4-Bis(2-hydroxyethyl)terephthalamide)-exhibit opposite effects on asphalt properties, despite having nearly the same carbon footprint. DOTP improves elastic recovery in multiple creep recovery tests (MCRT), while HETP increases strain accumulation and reduces elasticity. Density functional theory (DFT) shows that DOTP's molecular structure can disperse well in bitumen mixtures by binding to both polar and non-polar components. In contrast, HETP binds only to the binder's polar sites, lacking adequate dispersion. This increases the risk of aggregation of polar compounds in the bitumen mixture, resulting in a more deformation-prone binder. A techno-economic analysis highlights trade-offs between sustainability and performance in industrial-scale synthesis. This study advocates for applying first-principles thinking in material design, coupled with experimental validation, to engineer plastic waste-derived additives that achieve both performance and sustainability goals.

36 MATERIALS SCIENCE↗

Mesh-like structure integrated core-shell-shell nanocomposites for enhanced stability and performance in carbon capture

Carbon capture is essential for mitigating climate change, yet most sorbents struggle to combine high capacity with chemical stability. Here we report core-shell-shell (CSS) nanocomposites that integrate adsorption efficiency with exceptional robustness. The design couples a metal-organic framework (MOF) core, which enriches local CO 2 concentration, with a polyamine shell that is reorganized into a porous, ordered network through entanglement with an outer covalent organic framework (COF) shell. This hierarchical architecture enables dual amine functionalization via sequential “click” and Schiff-base reactions, achieving a CO 2 uptake of 3.4 mmol g −1 at 1 bar. The COF outer layer also acts as a protective barrier, suppressing humidity interference and doubling cycling stability under simulated flue gas. Remarkably, the nanocomposites maintain structural integrity after one week in strongly acidic (3 M HNO 3 ) or basic (NaOH, pH=14) environments, underscoring their chemical resilience. By uniting high capacity, cycling durability, and environmental tolerance, this CSS strategy offers a versatile platform for next-generation carbon capture materials.

Yang, Sizhuo [Lawrence Berkeley National Laborator↗

Low Regeneration Temperature Sorbents for Direct Air Capture of CO 2

Susteon Inc., in partnership with University of Wyoming and SoCalGas, successfully met all major technical objectives to (1) scale up the ionic liquid catalyst for amine-based sorbents for improved desorption and absorption kinetics, (2) evaluate the catalyzed amine-based sorbents for direct CO 2 capture process to determine CO 2 adsorption and desorption rates and energy requirements, and (3) based on the experimental results, develop a conceptual process design to perform a preliminary economic assessment to evaluate the potential for DAC process cost reduction using the catalyzed sorbents. Amine doped solid sorbents are effective for DAC applications and can be regenerated by heat or by a combination of heat, steam, and vacuum. The best sorbent composition identified was polyethyleneimine (PEI) on fumed silica with 200 ppm ionic liquid catalyst. This sorbent formulation was shown to have a CO 2 breakthrough capacity twice that of the non-catalyzed sorbent, in laboratory tests with air at 75% relative humidity (RH). The CO 2 adsorption rate was also 40% higher than that of the non-catalyzed sorbent. This type of sorbents has the attributes required for lowering the overall cost of DAC with high CO 2 capacity and high rate of adsorption. The combination of an industrially utilized amine-based sorbent with a highly active catalyst to form a new class of materials for DAC provides a technically viable pathway for reducing the cost of DAC to <$100/tonne of CO 2 . Laboratory measurements show that the silica/PEI (polyethyleneimine) sorbents with 100 ppm of ionic liquid catalyst have almost 100% higher CO 2 cyclic capacity and 40% higher adsorption rate. Generally, CO 2 desorption occurred at higher temperatures with a rate of desorption 10 times faster than adsorption (which occurred at ambient conditions). Therefore, adsorption rate is a much more important factor in the cost of DAC because it is directly linked to the CAPEX of the total system and the cycle time (i.e., sorbent productivity in ton/day of CO 2 captured per unit volume of the air contactor). An initial process design, coupled with techno-economic analysis, based on optimal experimental results and preliminary resulting from structured sorbent testing, showed a path to lower the DAC cost from the current cost of over $200/tonne CO 2 to less than $100/tonne with a scale-up, mature state of the technology, with projected material and process improvements. These results demonstrate the effectiveness of the catalyst in silica/PEI sorbents in enhancing sorbents’ CO 2 working capacity, in (a) increasing the rate of adsorption and desorption, and (b) in lowering the CAPEX and OPEX of the DAC system employing the ionic liquid catalyzed sorbents.

01 COAL, LIGNITE, AND PEAT↗