Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection and ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-F-J-197: A Novel Intra-Beam Range Detection and Adaptation Strategy for Particle Therapy

Purpose: In-vivo range detection/verification is crucial in particle therapy for effective and safe delivery. The state-of-art techniques are not sufficient for in-vivo on-line range verification due to conflicts among patient dose, signal statistics and imaging time. We propose a novel intra-beam range detection and adaptation strategy for particle therapy. Methods: This strategy uses the planned mid-range spots as probing beams without adding extra radiation to patients. Such choice of probing beams ensures the Bragg peaks to remain inside the tumor even with significant range variation from the plan. It offers sufficient signal statistics for in-beam positron emission tomography (PET) due to high positron activity of therapeutic dose. The probing beam signal can be acquired and reconstructed using in-beam PET that allows for delineation of the Bragg peaks and detection of range shift with ease of detection enabled by single-layered spots. If the detected range shift is within a pre-defined tolerance, the remaining spots will be delivered as the original plan. Otherwise, a fast re-optimization using range-shifted beamlets and accounting for the probing beam dose is applied to consider the tradeoffs posed by the online anatomy. Simulated planning and delivery studies were used to demonstrate the effectiveness of the proposed techniques. Results: Simulations with online range variations due to shifts of various foreign objects into the beam path showed successful delineation of the Bragg peaks as a result of delivering probing beams. Without on-line delivery adaptation, dose distribution was significantly distorted. In contrast, delivery adaptation incorporating detected range shift recovered well the planned dose. Conclusion: The proposed intra-beam range detection and adaptation utilizing the planned mid-range spots as probing beams, which illuminate the beam range with strong and accurate PET signals, is a safe, practical, yet effective approach to address range uncertainty issues in particle therapy.

60 APPLIED LIFE SCIENCES↗

Detection range enhancement using circularly polarized light in scattering environments for infrared wavelengths

We find for infrared wavelengths there are broad ranges of particle sizes and refractive indices that represent fog and rain where the use of circular polarization can persist to longer ranges than linear polarization. Using polarization tracking Monte Carlo simulations for varying particle size, wavelength, and refractive index, we show that for specific scene parameters circular polarization outperforms linear polarization in maintaining the intended polarization state for large optical depths. This enhancement with circular polarization can be exploited to improve range and target detection in obscurant environments that are important in many critical sensing applications. Specifically, circular polarization persists better than linear for radiation fog in the short-wave infrared, for advection fog in the short-wave infrared and the long-wave infrared, and large particle sizes of Sahara dust around the 4 micron wavelength.

36 MATERIALS SCIENCE↗

Chirped laser dispersion spectroscopy for spectroscopic chemical sensing with simultaneous range detection

Spectroscopic chemical detection requires knowledge or determination of an optical path for accurate quantification of path-integrated concentration of species. Continuous- wave-laser-based spectroscopic systems operating in an open integrated-path remote sensing configuration are usually not equipped for optical path determination. Here we demonstrate a measurement technique capable of simultaneous spectroscopic chemical quantification and range finding. Here, the range-finding functionality is implemented with chirped laser dispersion spectroscopy. The methodology is potentially useful for remote chemical sensing in a hard-target LIDAR configuration and for automatic calibration of gas cells with unknown or varying lengths.

03 NATURAL GAS↗

Ultra-wideband short-pulse radar with range accuracy for short range detection

An ultra-wideband (UWB) radar transmitter apparatus comprises a pulse generator configured to produce from a sinusoidal input signal a pulsed output signal having a series of baseband pulses with a first pulse repetition frequency (PRF). The pulse generator includes a plurality of components that each have a nonlinear electrical reactance. A signal converter is coupled to the pulse generator and configured to convert the pulsed output signal into a pulsed radar transmit signal having a series of radar transmit pulses with a second PRF that is less than the first PRF.

47 OTHER INSTRUMENTATION↗

A New Miniaturized Acoustic Transmitter for Marine Animal Tracking

Most marine renewable energy (MRE) technologies are still in their infancy. Many uncertainties remain regarding MRE systems’ impacts on the marine environment and species where they are deployed, which is one of the major hurdles for these systems to be widely adopted at a commercial scale. Currently, the primary technologies to monitor marine animals’ behavior around existing or potential MRE deployment sites are optical and acoustic imaging. However, these methods cannot identify individual animals and thus are less useful in identifying protected species and studying their behavior. Implantable acoustic transmitters with unique identification codes could serve as a complementary technology. To minimize potential bias introduced to the study results, the implanted transmitters must be sufficiently small and light to not affect the animals’ behavior while still having acceptable signal strengths and service life. Recently, we developed a new miniaturized acoustic transmitter that offers a significantly improved signal strength and service life (140 days [projected value] at a 5-s transmission interval) in a smaller and lighter package (0.45 g in the air), compared to the existing technologies. The detection range and detection efficiency of the new transmitter were tested in an actual marine environment and demonstrated a detection range of up to 330 m, a 65% improvement over the existing commercial counterparts operating at similar frequencies. Here, we report the design principles, performance, and manufacturing procedure of the transmitter. Finally, theoretical estimates of the detection range, the actual range, and detection efficiency results from the field testing are presented.

acoustic telemetry↗

Unmanned Aircraft Systems (UAS) and Light Detection and Ranging (LiDAR)/Camera Technologies to Detect Avian Events and Other Environmental Measures at Utility- Scale Power Plants (Final Report)

The goal of this project was to develop and validate two complementary, cost-effective remote sensing technologies to monitor avian fatalities at utility-scale solar facilities: fixed platform (Animal Activity Monitoring-AAM) and aerial-based (Uncrewed Aircraft Systems-UAS). This project used these features with machine learning to automate the detection of avian carcasses and nests at solar facilities.

14 SOLAR ENERGY↗

Under canopy light detection and ranging–based autonomous navigation

This study describes a light detection and ranging (LiDAR)–based autonomous navigation system for an ultralightweight ground robot in agricultural fields. The system is designed for reliable navigation under cluttered canopies using only a 2D Hokuyo UTM–30LX LiDAR sensor as the single source for perception. Its purpose is to ensure that the robot can navigate through rows of crops without damaging the plants in narrow row–based and high–leaf–cover semistructured crop plantations, such as corn ( Zea mays ) and sorghum ( Sorghum bicolor ). The key contribution of our work is a LiDAR–based navigation algorithm capable of rejecting outlying measurements in the point cloud due to plants in adjacent rows, low–hanging leaf cover or weeds. The algorithm addresses this challenge using a set of heuristics that are designed to filter out outlying measurements in a computationally efficient manner, and linear least squares are applied to estimate within–row distance using the filtered data. Moreover, a crucial step is the estimate validation, which is achieved through a heuristic that grades and validates the fitted row–lines based on current and previous information. The proposed LiDAR–based perception subsystem has been extensively tested in production/breeding corn and sorghum fields. In such variety of highly cluttered real field environments, the robot logged more than 6 km of autonomous run in straight rows. These results demonstrate highly promising advances to LiDAR–based navigation in realistic field environments for small under–canopy robots.

42 ENGINEERING↗

Sonic Detection and Ranging (SODAR) Wind Profiler Instrument Handbook

The SODAR (Sonic Detection and Ranging) wind profiler measures wind profiles and backscattered signal strength between (nominally) 15 meters (m) and 500 m. It operates by transmitting acoustic energy into the atmosphere and measuring the strength and frequency of backscattered energy. The strength of the backscattered signal is determined by the strength of temperature inhomogeneities with size on the order of 10 centimeters (cm). Assuming the scattering elements in the atmosphere are moving with the mean wind, the horizontal wind field can be derived. The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF) has a system developed by Scintec, Inc. that transmits a sequence of frequencies to enhance signal determination.

17 WIND ENERGY↗

Noise analysis of optimized Ge/Ge{sub 1−x}Sn{sub x}/Ge p–n–p heterojunction phototransistors for long-wavelength optical receivers

Present literature investigates noise analysis and optimal design for Ge/Ge{sub 1−x}Sn{sub x}/Ge based p–n–p heterojunction phototransistors (HPT) for long-wavelength optical receivers. We calculate gain, noise powers, signal-to-noise ratio, absorption coefficient and optical responsivity of proposed GeSn-based HPT and investigate their dependence on various structural parameters to optimize the design. The proposed HPT incorporates Ge{sub 1−x}Sn{sub x} alloy in the base layer as the active layer, allow to extend the photo detection range from near infrared to mid-infrared to achieve a wide range of detection. The results show that the signal-to-noise ratio (SNR) is strongly dependent on the operating frequency and the introduction of Sn in the base layer can improve the signal-to-noise ratio in the high-frequency region. The calculated results also show that even in the presence of small defects and misfit dislocations at the heterointerfaces, high SNR is still achievable for the proposed structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared light-assisted preparation of Ag nanoparticles-reduced graphene oxide nanocomposites for non-enzymatic H{sub 2}O{sub 2} sensing

Graphical abstract: An infrared light irradiation method has been developed for preparation of AgNPs/rGO nanocomposites for electrochemical detection of H{sub 2}O{sub 2}. - Highlights: • AgNPs/rGO nanocomposites have been prepared by photochemical method. • AgNPs/rGO nanocomposites exhibit good sensing performances for detection of H{sub 2}O{sub 2}. • The present work provides a simple and green method for preparation of rGO-based materials. - Abstract: A green method has been developed for preparation of Ag nanoparticles/reduced graphene oxide (AgNPs/rGO) nanocomposites by infrared light irradiation. The characterizations indicate the successful preparation of AgNPs/rGO nanocomposites. Most importantly, AgNPs/rGO nanocomposites exhibit excellent electrocatalytic activity for reduction of H{sub 2}O{sub 2}, leading to a high-performance non-enzymatic H{sub 2}O{sub 2} sensor with linear detection range and detection limit about 0.1 mM to 140 mM (r = 0.9896) and 3.0 μM, respectively.

36 MATERIALS SCIENCE↗

A call to standardize metrics for monitoring baleen whales near marine construction activities

Effective monitoring is necessary to protect marine mammal species during the construction of offshore infrastructure. The tools for detecting or monitoring marine mammals span traditional (e.g., visual observers, optical cameras), to newer (e.g., passive acoustic monitoring, infrared cameras, tags), and emerging (e.g., satellite imagery, environmental DNA, dimethyl sulfide concentration) technologies. Some are better suited for use during offshore development; however, peer-reviewed literature does not typically evaluate and report on the performance of these various technologies. We define a minimum set of metrics related to efficacy (i.e., confusion matrix, precision and recall, probability of missed mitigation), detection range (i.e., maximum and reliable detection range, spatial resolution), and data delivery (i.e., detection latency, system reliability, temporal resolution) that we recommend are needed to assess the utility of monitoring technologies for this purpose. Following a literature review of relevant studies, we highlight which publications reported these metrics and used multiple technologies to compare relative performance. We also emphasize the benefits of multi-modal approaches and recommend performance assessments through modeling or large-scale collaborative field testing. These metrics will standardize data collection, reporting, and analysis; promote consistent and comparable results; and foster collaboration among developers, regulatory agencies, and scientists. This may lead to the co-development of technology that achieves multiple goals, has greater application, and can answer research questions while collecting data to fulfill permitting requirements. These metrics may also inform decisions on what systems regulatory agencies might consider using and reduce monitoring costs, which is critical to support the marine sector's rapid growth alongside marine mammal conservation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enclosure for light detection and ranging unit and related methods

This disclosure provides systems, methods, and apparatus related to light detection and ranging. In one aspect, a method comprises providing an apparatus. The apparatus comprises a LiDAR unit and a LiDAR enclosure. The LiDAR enclosure comprises a four-sided container having a square or rectangular cross-section with a first open end and a second open end comprising two opposite ends of the four-sided container. The LiDAR unit is attached to a mounting area inside the four-sided container. A reflective material is disposed on an interior of a second side and a third side of the four-sided container. Laser light is generated with the LiDAR unit. The laser light that has interacted with environment surrounding the LiDAR enclosure and that has been reflected back to the LiDAR unit is detected. The detected laser light is processed to construct an image of the environment surrounding the LiDAR enclosure.

Bandstra, Mark S.↗

Pixel multiplexing technique for real-time three-dimensional-imaging laser detection and ranging system using four linear-mode avalanche photodiodes

The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aims to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asymmetric devices based on carbon nanotubes for terahertz-range radiation detection

Various asymmetric detecting devices based on carbon nanotubes (CNTs) are studied. The asymmetry is understood as inhomogeneous properties along the conducting channel. In the first type of devices, an inhomogeneous morphology of the CNT grid is used. In the second type of devices, metals with highly varying work functions are used as the contact material. The relation between the sensitivity and detector configuration is analyzed. Based on the data obtained, approaches to the development of an efficient detector of terahertz radiation, based on carbon nanotubes are proposed.

36 MATERIALS SCIENCE↗