Riparian vegetation as an indicator of riparian condition: Detecting departures from historic condition across the North American West
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Performance of the Transition Radiation Tracker (TRT) at the ATLAS experiment with argon and krypton gas mixtures was simulated. The efficiency of transition radiation registration, which is necessary for electron identification, was estimated along with the electron identification capabilities under such conditions.
An input signal and a reset signal are provided to respective inputs of a resettable flip-flop. The resettable flip-flop generates an output signal. The output signal transitions from a first logic state to a second logic state in response to corresponding transitions of the input signal and transitions from the second logic state to the first logic state in response to assertion of the reset signal. A warning signal is asserted in response to transitions of the input signal from the second logic state to the first logic state. A logic gate forwards the output signal when the warning signal is de-asserted and provides a signal in the first logic state in response to assertion of the warning signal.
The possibility of using weak optical signals to perform sensing of delicate samples constitutes one of the main goals of quantum photonic sensing. Furthermore, the nanoscale confinement of electromagnetic near fields in photonic platforms through surface plasmon polaritons has motivated the development of highly sensitive quantum plasmonic sensors. Despite the enormous potential of plasmonic platforms for sensing, this class of sensors is ultimately limited by the quantum statistical fluctuations of surface plasmons. Indeed, the fluctuations of the electromagnetic field severely limit the performance of quantum plasmonic sensing platforms in which delicate samples are characterized using weak near-field signals. Furthermore, the inherent losses associated with plasmonic fields levy additional constraints that challenge the realization of sensitivities beyond the shot-noise limit. Here, we introduce a protocol for quantum plasmonic sensing based on the conditional detection of plasmons. We demonstrate that the conditional detection of plasmonic fields, via plasmon subtraction, provides a new degree of freedom to control quantum fluctuations of plasmonic fields. This mechanism enables improvement of the signal-to-noise ratio of photonic sensors relying on plasmonic signals that are comparable to their associated field fluctuations. Consequently, the possibility of using weak plasmonic signals to sense delicate samples, while preserving the sample properties, has important implications for molecule sensing, and chemical detection.
Data collected from devices and human condition may be used to forewarn of critical events such as machine/structural failure or events from brain/heart wave data stroke. By monitoring the data, and determining what values are indicative of a failure forewarning, one can provide adequate notice of the impending failure in order to take preventive measures. This disclosure teaches a computer-based method to convert dynamical numeric data representing physical objects (unstructured data) into discrete-phase-space states, and hence into a graph (structured data) for extraction of condition change.
We analyze the conditions for detection of CO(1-0) emission in the Large Magellanic Cloud, using the recently completed second NANTEN CO survey. In particular, we investigate correlations between CO integrated intensity and H I integrated intensity, peak brightness temperature, and line width at a resolution of 2.'6 ({approx}40 pc). We find that significant H I column density (exceeding {approx}10{sup 21} cm{sup -2}) and peak brightness temperature (exceeding {approx}20 K) are necessary but not sufficient conditions for CO detection, with many regions of strong H I emission not associated with molecular clouds. The large scatter in CO intensities for a given H I intensity persists even when averaging on scales of >200 pc, indicating that the scatter is not solely due to local conversion of H I into H{sub 2} near GMCs. We focus on two possibilities to account for this scatter: either there exist spatial variations in the I(CO) to N(H{sub 2}) conversion factor, or a significant fraction of the atomic gas is not involved in molecular cloud formation. A weak tendency for CO emission to be suppressed for large H I linewidths supports the second hypothesis, insofar as large linewidths may be indicative of warm H I, and calls into question the likelihood of forming molecular clouds from colliding H I flows. We also find that the ratio of molecular to atomic gas shows no significant correlation (or anticorrelation) with the stellar surface density, though a correlation with midplane hydrostatic pressure P{sub h} is found when the data are binned in P{sub h} . The latter correlation largely reflects the increasing likelihood of CO detection at high H I column density.
Assuming that the universe contains a dark energy fluid with a constant linear equation of state and a constant sound speed, we study the prospects of detecting dark energy perturbations using CMB data from Planck, cross-correlated with galaxy distribution maps from a survey like LSST. We update previous estimates by carrying a full exploration of the mock data likelihood for key fiducial models. We find that it will only be possible to exclude values of the sound speed very close to zero, while Planck data alone is not powerful enough for achieving any detection, even with lensing extraction. We also discuss the issue of initial conditions for dark energy perturbations in the radiation and matter epochs, generalizing the usual adiabatic conditions to include the sound speed effect. However, for most purposes, the existence of attractor solutions renders the perturbation evolution nearly independent of these initial conditions.
The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this paper, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Finally and furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.
Designing and refactoring complex scientific code, such as the E3SM land model (ELM), for new computing architectures is challenging. This paper presents design strategies and technical approaches to develop a data-oriented, GPU-ready ELM model using compiler directives (OpenACC/OpenMP). We first analyze the datatypes and processes in the original ELM code. Then we present design considerations for ultrahigh-resolution ELM (uELM) development for massive GPU systems. These techniques include the global data-oriented simulation workflow, domain partition, code porting and data copy, memory reduction, parallel loop restructure and flattening, and race condition detection. We implemented the first version of uELM using OpenACC targeting the NVidia GPUs in the Summit supercomputer at Oak Ridge National Laboratory. During the implementation, we developed a software tool (named SPEL) to facilitate code generation, verification, and performance tuning using these techniques. The first uELM implementation for Nvidia GPUs on Summit delivered promising results: 1) over 98% of the ELM code was automatically generated and tuned by scripts. Most ELM modules had better computational performances than the original ELM code for CPUs. The GPU-ready uELM is more scalable than the CPU code on fully-loaded Summit nodes. Example profiling results from several modules are also presented to illustrate the performance improvements and race condition detection. The lessons learned and toolkit developed in the study are also suitable for further uELM deployment using OpenMP on the first US exascale computer, Frontier, equipped with AMD CPUs and GPUs.
A method and device for determining the position of a rotor in a brushless motor is provided. The method generally includes: injecting electrical signals into a stator of the brushless motor; measuring scattering parameters reflected back from the stator, wherein the scattering parameters are influenced by the near-field dynamics impaired by the motor; and comparing the measured scattering parameters to a predetermined data set of scattering parameters for known rotor positions to determine the position of the rotor. The method and device is also suitable for determining a condition of a motor or a generator.
The modern industrial environment is equipping myriads of smart manufacturing machines where the state of each device can be monitored continuously. Such monitoring can help identify possible future failures and develop a cost-effective maintenance plan. However, it is a daunting task to perform early detection with low false positives and negatives from the huge volume of collected data. This requires developing a holistic machine learning framework to address the issues in condition monitoring of high priority components and develop efficient techniques to detect anomalies that can detect and possibly localize the faulty components. This paper presents a comparative analysis of recent machine learning approaches for robust, cost-effective anomaly detection in cyber-physical systems. While detection has been extensively studied, very few researchers have analyzed the localization of the anomalies. We show that supervised learning outperforms unsupervised algorithms. For supervised cases, we achieve near-perfect accuracy of 98% (specifically for tree-based algorithms). In contrast, the best-case accuracy in the unsupervised cases was 63%—the area under the receiver operating characteristic curve (AUC) exhibits similar outcomes as an additional metric.
Since most available micro x-ray fluorescence (micro-XRF) spectrometers operate in air, which does not allow the analysis of low-Z elements (Z{<=}14), a special micro-XRF spectrometer has been designed to extend the analytical range down to light elements (Z{>=}6). It offers improved excitation and detection conditions necessary for light element analysis. To eliminate absorption of the exciting and fluorescent radiation, the system operates under vacuum condition. Sample mapping is automated and controlled by specialized computer software developed for this spectrometer. Several different samples were measured to test and characterize the spectrometer. The spot size has been determined by scans across a 10 {mu}m Cu wire which resulted in a full width at half maximum of 31 {mu}m for Mo K{alpha} line (17.44 keV) and 44 {mu}m effective beam size for the Cu K edge and 71 {mu}m effective beam size for the Cu L edge. Lower limits of detection in the picogram range for each spot (or {mu}g/cm{sup 2}) were obtained by measuring various thin metal foils under different conditions. Furthermore, detection limits in the parts per million range were found measuring NIST621 standard reference material. Area scans of a microscopic laser print and NaF droplet were performed to show mapping capabilities.
Abstract not provided.
A method may detect a flashback condition in a fuel nozzle of a combustor. The method may include obtaining a current acoustic pressure signal from the combustor, analyzing the current acoustic pressure signal to determine current operating frequency information for the combustor, and indicating that the flashback condition exists based at least in part on the current operating frequency information.
Recent blackouts of power systems in North America and throughout the world have shown how critical a reliable power system is to modern societies, and the enormous economic and societal damage a blackout can cause. It has been noted that unanticipated operation of protection systems can contribute to cascading phenomena and, ultimately, blackouts. This project developed and field-tested two methods of Adaptive Protection systems utilizing synchrophasor data. One method detects conditions of system stress that can lead to unintended relay operation, and initiates a supervisory signal to modify relay response in real time to avoid false trips. The second method detects the possibility of false trips of impedance relays as stable system swings “encroach” on the relays’ impedance zones, and produces an early warning so that relay engineers can re-evaluate relay settings. In addition, real-time synchrophasor data produced by this project was used to develop advanced visualization techniques for display of synchrophasor data to utility operators and engineers.
A challenge was posed to the criticality safety consultant to consider whether instrumentation identified by Plant Management in an existing facility could be claimed as appropriate safety measures to ensure compliance with moderator content limits in uranium dioxide (UO{sub 2}) powder. During processing of low enriched UO{sub 2}, trays of powder are heated in a steam and hydrogen environment in order to reduce fluoride levels. Whilst in the furnace environment criticality safety is ensured by the geometry of the furnace trays used to convey the powder; however, upon leaving the furnace the UO{sub 2} is bulked to a 210 litre drum subject to limited moderation control. Under fault conditions there is a potential that the powder may become wetted due to an imbalance in furnace gas flows resulting in steam condensing in the cooling section of the furnace. Therefore, the safety case methodology followed suggests that two independent and diverse safety measures are provided to terminate the progression of the fault(s) to criticality. The existing criticality safety case credits an infra-red moisture meter as one of two safety measures; however, the calibration procedure required to ensure this device remains suitable is a considerable challenge from a plant operability perspective. As an initial review failed to identify any suitable like-for-like replacement, the National Nuclear Laboratory (NNL) Nuclear Safety Section were requested by the customer to consider the existing criticality safety case and investigate whether any existing instrumentation could be used as an alternative method of detecting conditions in which excess moisture could be present within the furnace trays. A number of solutions were proposed and the benefits and challenges around each are discussed in this paper, concluding with the approach adopted by the project. (authors)
The detection conditions and features of direct and scattered neutron wave interference are studied on magnetized Co{sub 67}Fe{sub 31}V{sub 2} alloy slabs. The angular intensity distributions of neutrons passed through a sample are measured for the opposite polarization directions of the initial neutron beam. The sought-for effect that is induced by the magnetic scattering on crystal structure irregularities in specimens manifest itself by different areas of peaks “without neutron spin flip.” The ratio of these areas depends on the thermal treatment mode, sample thickness and strength of the magnetic field applied to the sample. The peaks “with neutron spin flip” are due to the mechanism of neutron wave passage through magnetononcollinear boundaries. The methods for experimental data acquisition and processing are reported as well.
The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.