A bonding material for optically immersing infrared detectors from 2 to 14 micro-meters
Visible and infrared transmitting properties of epoxy resin suitable for infrared detectors
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Visible and infrared transmitting properties of epoxy resin suitable for infrared detectors
Transformation of meteoroid flux patterns relative to attractive center to corresponding patterns about moving nongravitational detector
For a variety of space-science applications, such as gamma-ray spectroscopy, the introduction of cryogenic cooling via a cryocooler can greatly increase the potential science return by allowing the use of more sensitive and lower noise detectors.
Excessheat capacity in a bolometric detector has the consequence of increasing or leading to multiple device time con-stants.The Mo/Au bilayer transition edge sensor (TES) bolo-metric detectors intended for the high resolution mid-infrared spectrometer (HIRMES) have two response time, one of which is a few times longer than that estimated from materials used in the design. The relative contribution of this settling time to the overall time response of the detectors is roughly proportional with the pixel area, which ranges between ~0.3 and 2.6 mm2.Use of laser ablation to remove sections of the silicon membranes comprising the pixels results in a detector response with a smaller contribution from the secondary time constant.Additional information about the nature of this excess heat capacity is gleaned from glancing in-cidence x-ray diffraction, which reveals the presence of molyb-denum silicides near the silicon surface from the bi-layer deposi-tion.Quantitative analysis of the concentration of excess molyb-denum, estimated with secondary ion mass spectroscopy, is com-mensurate to the additional heat capacity needed to explain the anomalous time response of the detectors.
Fluctuations and broadening of energy-loss spectrum of charged particles passing through semiconductor detectors
Engineering analyses on Surveyor lunar dust particle detector instrumentation, and ground support equipment
Thick lithium drifted semiconductor silicon detectors for investigation of fluctuations of energy loss by high and intermediate energy particles
List of publications for final perfomance report are: Detectors for the JWST Near-Infrared Spectrometer Rauscher, B.J., Strada, P., Regan, M.W., Figer, D.F., Jakobsen, P., Moseley, H.S., & Boeker, T. 2004, SPIE Detectors for the JWST Near-Infrared Spectrometer Rauscher, B.J., Strada, P., Regan, M.W., Figer, D.F., Jakobsen, P., Moseley, H.S., & Boeker, T. 2004, AAS, 203, 124.07 Independent Testing of JWST Detector Prototypes Figer, D.F., Rauscher, B. J., Regan, M. W., Morse, E., Balleza, J., Bergeron, L., & Stockman, H. S. 2003 , SPIE, 5 167 The Independent Detector Testing Laboratory and the NGST Detector Program Figer, D.F., Agronin, M., Balleza, J., Barkhouser, R., Bergeron, L., Greene, G. R., McCandliss, S. R., Rauscher, B. J., Reeves, T., Regan, M. W., Sharma, U., Stockman, H. S. 2003, SPIE, 4850,981 Intra-Pixel Sensitivity in NIR Detectors for NGST Sharma, U., Figer, D.F., Sivaramakrishnan, A., Agronin, M., Balleza, J., Barkhouser, R., Bergeron, L., Greene, G. R., McCandliss, S. R., Rauscher, B. J., Reeves, T., Regan, M. W., Stockman, H. S. 2003, SPIE, 4850,1001 NIRCAM Image Simulations for NGST Wavefiont SensinglPS A. Sivaramakrishnan, D. Figer, H. Bushouse, H. S. Stockman (STScI),C. Ohara , D. Redding (JPL), M. Im (IPAC), & J. Offenberg (Raytheon) 2003, SPIE, 4850,388 Ultra-Low Background Operation of Near-Infrared Detectors for NGS Rauscher, B. J., Figer, D. F., Agronin, M., Balleza, J., Barkhouser, R., Bergeron, L., Greene, G. R., McCandliss, S. R., Reeves, T., Regan, M. W., Sharma, U., Stockman, H. S. 2003, SPIE, 4850,962 The Independent Detector Testing Laboratory and the JWST Detector Program Figer, D.F. et a1.2003, AAS201, #131.05
Fluctuations of energy loss by charged particles in lithium-drifted silicon semiconductor detectors
Samples for transmission electron microscopy (TEM) were prepared from 3 mm diameter cylinders electro-discharge machined from the heat-treated ingots. Slices sectioned from the cylinders were mechanically ground and electrochemically thinned in a twinjet Tenupol-3 polisher. Microstructural and energy-dispersive X-ray spectroscopy (EDXS) studies were conducted in a Philips 400T TEM equipped with a double tilt goniometer and a KEVEX Si/Li X-ray detector.
The Altus Cumulus Electrification Study (ACES) was conducted during the month of August, 2002 in an area near Key West, Florida. One of the goals of this uninhabited aerial vehicle (UAV) study was to collect time resolved optical pulse data from thunderstorms. During the month long campaign, we acquired 5294 lightning generated optical pulses. Most of these observations were made while close to the top of the storms. We divided our data into two amplitude groups based on prior NASA U2 aircraft optical data and our pulse characteristics. The group of large pulses with radiance greater than 2.1 mW /sq m sr had mean and median 10 - 10% optical pulse widths of 765 and 735 microns respectively, the 50-50% pulse widths of 396 and 355 microns respectively, and 10-90% rise times of 290 and 260 microns. These values are very similar to the previous U2 based optical results The other group of pulses consisting of slightly more than a quarter of the total pulses observed had radiances less than the minimum values detected in the U2 study. The small pulses were narrower than the large pulses with 5040% mean and median values of 198 and 160 ps respectively. Only 12 % of the flashes contained only small pulses, minimizing the impact of this data on the estimates of detection efficiencies of the orbital instruments, the Lightning Imaging Sensor and Optical Transient Detector.
Solid state image sensor in infrared and visible regions
Spectra of noble gases in 4-micron region, using IR spectrometer equipped with cooled lead sulphide detector
Mercury cadmium telluride as 1- to 20-micrometer wavelength infrared detector for space applications
Resin bonding material suitable for IR detectors noting transmission properties
Optical devices for enhancement of semitransparent photocathode quantum efficiency applied to TV camera tubes, image intensifiers and other imaging detectors
The abundance of Fe relative to H is obtained by using resonantly scattered intensities of lambda 284 of Fe XV that were measured with OSO-7 and resonantly scattered intensities of L-alpha of H I that were obtained by Gabriel (1971). Because of possible differences in electron densities along lines of sight for these non-simultaneous measurements and in relative calibrations, results are rather uncertain but still indicate that the average Fe abundance relative to H in the corona appears to be at least as large as a recent photospheric abundance. Some limitations in using this method for obtaining abundances are examined for future experiments with simultaneous measurements and well calibrated detectors.
The pyroelectric property of triglycine sulfate and its application in the detection of infrared radiation are described. The detectivities of pyroelectric detectors and other types of infrared detectors are compared. The thermal response of a pyroelectric detector element and the resulting electrical response are derived in terms of the material parameters. The noise sources which limit the sensitivity of pyroelectric detectors are described, and the noise equivalent power for each noise source is given as a function of frequency and detector area.