Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

Alignment of the ATLAS Inner Detector in Run 2

The performance of the ATLAS Inner Detector alignment has been studied using pp collision data at s√=13TeV collected by the ATLAS experiment during Run 2 (2015–2018) of the Large Hadron Collider (LHC). The goal of the detector alignment is to determine the detector geometry as accurately as possible and correct for time-dependent movements. The Inner Detector alignment is based on the minimization of track-hit residuals in a sequence of hierarchical levels, from global mechanical assembly structures to local sensors. Subsequent levels have increasing numbers of degrees of freedom; in total there are almost 750,000. The alignment determines detector geometry on both short and long timescales, where short timescales describe movements within an LHC fill. The performance and possible track parameter biases originating from systematic detector deformations are evaluated. Momentum biases are studied using resonances decaying to muons or to electrons. The residual sagitta bias and momentum scale bias after alignment are reduced to less than ~0.1 TeV -1 and 0.9×10 -3 , respectively. Impact parameter biases are also evaluated using tracks within jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton reconstruction with the TOTEM Roman pot detectors for high- β * LHC data

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β* data-taking period at $\sqrt({s})$ = 13 TeV in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon Time-of-Flight studies for cosmic background rejection in the Short Baseline Near Detector

The Short-Baseline Neutrino (SBN) program at Fermilab is a cutting-edge project in experimental neutrino physics. One of its main goals is to systematically investigate the possible existence of eV-scale sterile neutrinos. This phenomenon has been hypothesized to explain some anomalies found in short-range experiments and, if confirmed, would imply a substantial extension of the Standard Model. SBN also offers an important opportunity to deepen the understanding of neutrino-nucleus interactions in the GeV energy range, through the use of Liquid Argon Time Projection Chambers (LArTPC) detectors, a fundamental technology also for the future DUNE experiment. The SBN experimental infrastructure consists of three detectors aligned along the Booster Neutrino Beamline at Fermilab. Among them, the detector located closest to the neutrino source, SBND (Short-Baseline Near Detector), positioned approximately 110 meters from the target, plays a key role in directly characterizing the initial neutrino flux. This allows for a direct comparison with the measurements from the far detector, ICARUS, located about 600 meters from the source, in order to search for potential signs of anomalous neutrino oscillations. My master's thesis focuses on the commissioning and characterization activities of the SBND detector, with particular reference to the Cosmic Ray Tagger (CRT). The CRT is a subsystem for identifying and rejecting events produced by cosmic rays, which constitute the main source of background for surface experiments like SBND. The activity began with the commissioning of the final components of the detector, as well as their validation to verify their correct functioning and signal acquisition. A central part of my work involved studying the veto efficiency of the CRT system, analyzing the rate of cosmic ray-induced events to quantify any loss of neutrino-induced events caused by cosmic background. This allowed for a more precise evaluation of the systematic impact of the CRT on the useful physics sample. A further phase of my analysis involved an in-depth study of the temporal correlation between the CRT signals and those acquired by the LArTPC's internal photodetector system, consisting of photomultiplier tubes and X-ARAPUCA devices. The objective is to explore the possibility of using combined temporal information as an additional criterion for discriminating between cosmic signals and signals genuinely due to neutrino interaction. Preliminary results indicate the presence of characteristic temporal signatures that could be exploited to improve event selection and increase the purity of the neutrino-induced sample. These methodologies will certainly contribute to the optimization of SBND analysis strategies and, more generally, to a better understanding of background mechanisms in next-generation LArTPC experiments.

Corallo, Annalea [Ferrara U.]↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

Measurement of the total cross section and $\rho$-parameter from elastic scattering in pp collisions at $\sqrt{s}=13$ TeV with the ATLAS detector

In a special run of the LHC with β* = 2.5 km, proton–proton elastic-scattering events were recorded at $\sqrt{s}=13$ TeV with an integrated luminosity of $340$ μb -1 using the ALFA subdetector of ATLAS in 2016. The elastic cross section was measured differentially in the Mandelstam t variable in the range from - t = 2.5 · 10 -4 GeV 2 to - t = 0.46 GeV 2 using 6.9 million elastic-scattering candidates. This paper presents measurements of the total cross section σ tot , parameters of the nuclear slope, and the p -parameter defined as the ratio of the real part to the imaginary part of the elastic-scattering amplitude in the limit t → 0. These parameters are determined from a fit to the differential elastic cross section using the optical theorem and different parameterizations of the t-dependence. The results for σ tot and p are σ tot (pp → X) = 104.7 ± 1.1 mb, p = 0.098 ± 0.011. The uncertainty in σ tot is dominated by the luminosity measurement, and in p by imperfect knowledge of the detector alignment and by modelling of the nuclear amplitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of Pop-up Detector Arrays on Si Wafers

High sensitivity is a basic requirement for a new generation of thermal detectors. To meet the requirement, close-packed, two-dimensional silicon detector arrays have been developed in NASA Goddard Space Flight Center. The goal of the task is to fabricate detector arrays configured with thermal detectors such as infrared bolometers and x-ray calorimeters to use in space fliGht missions. This paper focuses on the fabrication and the mechanical testing of detector arrays in a 0.2 mm pixel size, the smallest pop-up detectors being developed so far. These array structures, nicknamed "PUDS" for "Pop-Up Detectors", are fabricated on I pm thick, single-crystal, silicon membranes. Their designs have been refined so we can utilize the flexibility of thin silicon films by actually folding the silicon membranes to 90 degrees in order to obtain close-packed two-dimensional arrays. The PUD elements consist of a detector platform and two legs for mechanical support while also serving as electrical and thermal paths. Torsion bars and cantilevers connecting the detector platform to the legs provide additional flexures for strain relief. Using micro-electromechanical structure (MEMS) fabrication techniques, including photolithography, anisotropic chemical etching, reactive-ion etching, and laser dicing, we have fabricated PLTD detector arrays of fourteen designs with a variation of four parameters including cantilever length, torsion bar length and width, and leg length. Folding tests were conducted to test mechanical stress distribution for the array structures. We obtained folding yields and selected optimum design parameters to reach minimal stress levels. Computer simulation was also employed to verify mechanical behaviors of PUDs in the folding process. In addition, scanning electron microscopy was utilized to examine the flatness of detectors and the alignment of detector pixels in arrays. The fabrication of thermistors and heaters on the pop-up detectors is under way, preparing us for the next step of the experiment, the thermal test.

Li, Mary J.↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Lunar Observations to Validate Pointing Accuracy and Geolocation, Detector Sensitivity Stability and Static Point Response of the CERES Instruments

Validation of in-orbit instrument performance is a function of stability in both instrument and calibration source. This paper describes a method using lunar observations scanning near full moon by the Clouds and Earth Radiant Energy System (CERES) instruments. The Moon offers an external source whose signal variance is predictable and non-degrading. From 2006 to present, these in-orbit observations have become standardized and compiled for the Flight Models -1 and -2 aboard the Terra satellite, for Flight Models-3 and -4 aboard the Aqua satellite, and beginning 2012, for Flight Model-5 aboard Suomi-NPP. Instrument performance measurements studied are detector sensitivity stability, pointing accuracy and static detector point response function. This validation method also shows trends per CERES data channel of 0.8% per decade or less for Flight Models 1-4. Using instrument gimbal data and computed lunar position, the pointing error of each detector telescope, the accuracy and consistency of the alignment between the detectors can be determined. The maximum pointing error was 0.2 Deg. in azimuth and 0.17 Deg. in elevation which corresponds to an error in geolocation near nadir of 2.09 km. With the exception of one detector, all instruments were found to have consistent detector alignment from 2006 to present. All alignment error was within 0.1o with most detector telescopes showing a consistent alignment offset of less than 0.02 Deg.

Daniels, Janet L.↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EQ-SANS Detector Distance Check with Laser Alignment Method

In Small-Angle Scattering experiments, accurate distance information between sample and the detector is important. During the winter outage, January 2021, positions of detector, especially along the beam direction, were measured with the laser alignment tool to confirm values regularly deduced from silver behenate measurements. The results show that the current detector-z position of the EQ-SANS is accurate at all typically used detector positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment of the straw tracking detectors for the Fermilab Muon $g − 2$ experiment and systematic studies for a muon electric dipole moment measurement

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the coming months. The final goal of the experiment is to determine the muon magnetic anomaly to a precision of 140 ppb. This level of precision will provide indirect evidence of new physics, if the central value agrees with the previously-measured value of the magnetic anomaly. Essential in reducing the systematic uncertainty, through measurements of the muon beam profile, are the in-vacuum straw tracking detectors. A crucial prerequisite in obtaining accurate distributions of the beam profile is the internal alignment of the tracking detectors, which is described in this thesis. As a result of this position calibration, the tracking efficiency has increased by 3%, while the track quality increased by 4%. This thesis also discusses an additional measurement that will be made using the tracking detectors: a search for an electric dipole moment (EDM) of the muon, through the direct detection of an oscillation in the average vertical angle of the electron from the muon decay. An observation of a muon EDM would be evidencemore » of new physics and would provide a new source of CP violation in the charged lepton sector. Essential in measuring the EDM are accurate and precise estimations of potential non-zero radial and longitudinal magnetic fields, which were estimated using the Run-1 data. In addition, a preliminary analysis using the Run-1 data was undertaken to estimate the available precision for the magnetic anomaly measurement using the tracking detectors.« less

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Solar sensor subsystems alignment check using solar scans for the Halogen Occultation Experiment

The alignment of a dual-axes sun sensor subsystem to a telescope having a multiple sensor subsystem is described. The sun sensor consists of two analog and one digital silicon detectors. The analog detectors are shadow mask type operating in the visible spectrum. The detectors are mounted for azimuth and elevation positioning of biaxial gimbals. The digital detector is a linear diode array that operates at a spectral position of 0.7 micron and is used for elevation positioning. The position signals correspond to relative angles between the sun sensor and the solar disk. These three detectors are aligned on an Invar structure which is mounted to a Cassegrain telescope. This telescope relays solar radiance to an eight channel detector subsystem operating in the infrared range from 2 to 10 microns. The test technique and results to check the boresight alignment of these two subsystems by scanning the solar disk will be reported. The boresight alignment for both the azimuth and elevation axes of the two detector subsystems is verified using this technique.

Jurczyk, S. G.↗

Electro-optic Lightning Detector

The design, alignment, calibration, and field deployment of a solid-state lightning detector is described. The primary sensing component of the detector is a potassium dihydrogen phosphate (KDP) electro-optic crystal that is attached in series to a flat plate aluminum antenna; the antenna is exposed to the ambient thundercloud electric field. A semiconductor laser diode (lambda = 685 nm), polarizing optics, and the crystal are arranged in a Pockels cell configuration. Lightning-caused electric field changes are related to small changes in the transmission of laser light through the optical cell. Several hundred lightning electric field change excursions were recorded during five thunderstorms that occurred in the summer of 1998 at the NASA Marshall Space Flight Center (MSFC) in northern Alabama.

Koshak, William J.↗