Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimizing detector geometry for trace element mapping by X-ray fluorescence

Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate determination of segmented X-ray detector geometry

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. Furthermore, we show that the refined detector geometry greatly improves the results of experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling blur in various detector geometries for MeV radiography

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for applications in MeV radiography. Segmented scintillating detectors, where low Z scintillators combined with a high-Z metal matrix, can be designed in which the resolution increases with increasing metal fraction. Here, the combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution. Select detector geometries were tested by comparing simulation and experimental modulation transfer functions to validate the approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling blur in various detector geometries relevant to DARHT

Monte Carlo transport codes have been used to model the detector blur and energy deposition in various detector geometries for MeV radiography which are applicable to DARHT. Segmented scintillator detectors, where low Z scintillators combined with a high-Z metal matrix, are designed such that the resolution increases with increasing metal fraction. The combination of various types of metal intensification screens and storage phosphor imaging plates has also been studied. A storage phosphor coated directly onto a metal intensification screen has superior performance over a commercial plate. Stacks of storage phosphor plates and tantalum intensification screens show an increase in energy deposited and detective quantum efficiency with increasing plate number, at the expense of resolution which degrades with plate number. Excellent agreement between simulation and experimental modulation transfer functions for select detector geometries was found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

Reconstruction of Charged Particle Tracks in Realistic Detector Geometry Using a Vectorized and Parallelized Kalman Filter Algorithm

One of the most computationally challenging problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is finding and fitting particle tracks during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material e ects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filterbased methods for highly parallel, many-core SIMD and SIMT architectures that are now prevalent in high-performance hardware. Previously we observed significant parallel speedups, with physics performance comparable to CMS standard tracking, on Intel Xeon, Intel Xeon Phi, and (to a limited extent) NVIDIA GPUs. While early tests were based on artificial events occurring inside an idealized barrel detector, we showed subsequently that our mkFit software builds tracks successfully from complex simulated events (including detector pileup) occurring inside a geometrically accurate representation of the CMS-2017 tracker. Here, we report on advances in both the computational and physics performance of mkFit, as well as progress toward integration with CMS production software. Recently we have improved the overall eciency of the algorithm by preserving short track candidates at a relatively early stage rather than attempting to extend them over many layers. Moreover, mkFit formerly produced an excess of duplicate tracks; these are now explicitly removed in an additional processing step. We demonstrate that with these enhancements, mkFit becomes a suitable choice for the first iteration of CMS tracking, and eventually for later iterations as well. We plan to test this capability in the CMS High Level Trigger during Run 3 of the LHC, with an ultimate goal of using it in both the CMS HLT and oine reconstruction for the HL-LHC CMS tracker.

Cerati, Giuseppe↗

Parallelized and Vectorized Tracking Using Kalman Filters with CMS Detector Geometry and Events

The High-Luminosity Large Hadron Collider at CERN will be characterized by greater pileup of events and higher occupancy, making the track reconstruction even more computationally demanding. Existing algorithms at the LHC are based on Kalman filter techniques with proven excellent physics performance under a variety of conditions. Starting in 2014, we have been developing Kalman-filter-based methods for track finding and fitting adapted for many-core SIMD processors that are becoming dominant in high-performance systems. This paper summarizes the latest extensions to our software that allow it to run on the realistic CMS-2017 tracker geometry using CMSSW-generated events, including pileup. The reconstructed tracks can be validated against either the CMSSW simulation that generated the hits, or the CMSSW reconstruction of the tracks. In general, the code's computational performance has continued to improve while the above capabilities were being added. We demonstrate that the present Kalman filter implementation is able to reconstruct events with comparable physics performance to CMSSW, while providing generally better computational performance. Further plans for advancing the software are discussed.

Cerati, Giuseppe↗

Directional response of several geometries for reactor-neutrino detectors

Here we have modeled six abstracted detector designs, with the goal of determining their ability to resolve the direction to an antineutrino source, including two for which we have operational data for validating our computer modeling and analytical processes. We have found that the most promising options, regardless of scale and range, have angular resolutions on the order of a few degrees, which is better than any yet achieved in practice by a factor of at least two. We examine and compare several approaches to detector geometry for their ability not only to detect the inverse beta decay (IBD) reaction, but also to determine the source direction of incident antineutrinos. The information from these detectors provides insight into reactor power and burning profile, which is especially useful in constraining the clandestine production of weapons material. In a live deployment, a nonproliferation detector must be able to isolate the subject reactor, possibly from a field of much-larger power reactors; directional sensitivity can help greatly with this task. We also discuss implications for using such detectors in longer-distance observation of reactors, from a few kilometers to hundreds of kilometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Source Geometry on Detector Response Matrix Efficiency: Simulations of the PFUNS-MUSiC Experiments

This work looks at two different bare highly enriched uranium (HEU) systems, configuration one from Measurements of Uranium Subcritical and Critical (MUSiC) and Prompt Fission Uranium Neutron Spectrum (PFUNS) to see the effect geometry has on detector efficiency and the response matrix. The distance from the multiplying source, the medium between the source and detector, and the geometry of the source all play a part in the efficiency of the detector. These factors are especially important when performing spectrum unfolding. Spectrum unfolding is a process used to reconstruct a true spectrum from measured detector response data. It involves interpreting a set of measured values, such as a light signal from a scintillator, to recover the original neutron energy spectrum. This leads to the question, how much will the efficiency of a detector change when you measure a point source compared to an extended source? The distance and solid angle from the source to the detector may be different. It may only be a minuscule change, but in the spectrum unfolding process it can have a considerable effect on the unfolded spectrum

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Alignment of the ATLAS Inner Detector in Run 2

The performance of the ATLAS Inner Detector alignment has been studied using pp collision data at s√=13TeV collected by the ATLAS experiment during Run 2 (2015–2018) of the Large Hadron Collider (LHC). The goal of the detector alignment is to determine the detector geometry as accurately as possible and correct for time-dependent movements. The Inner Detector alignment is based on the minimization of track-hit residuals in a sequence of hierarchical levels, from global mechanical assembly structures to local sensors. Subsequent levels have increasing numbers of degrees of freedom; in total there are almost 750,000. The alignment determines detector geometry on both short and long timescales, where short timescales describe movements within an LHC fill. The performance and possible track parameter biases originating from systematic detector deformations are evaluated. Momentum biases are studied using resonances decaying to muons or to electrons. The residual sagitta bias and momentum scale bias after alignment are reduced to less than ~0.1 TeV -1 and 0.9×10 -3 , respectively. Impact parameter biases are also evaluated using tracks within jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Leveraging the checkpoint-restart technique for optimizing CPU efficiency of ATLAS production applications on opportunistic platforms

Data processing applications of the ATLAS experiment, such as event simulation and reconstruction, spend considerable amount of time in the initialization phase. This phase includes loading a large number of shared libraries, reading detector geometry and condition data from external databases, building a transient representation of the detector geometry and initializing various algorithms and services. In some cases the initialization step can take as long as 10-15 minutes. Such slow initialization has a significant negative impact on overall CPU efficiency of the production job, especially when the job is executed on opportunistic, often short-lived, resources such as commercial clouds or volunteer computing. In order to improve this situation, we can take advantage of the fact that ATLAS runs large numbers of production jobs with similar configuration parameters (e.g. jobs within the same production task). This allows us to checkpoint one job at the end of its configuration step and then use the generated checkpoint image for rapid startup of thousands of production jobs. By applying this technique we can bring the initialization time of a job from tens of minutes down to just a few seconds. In addition to that we can leverage container technology for restarting checkpointed applications on the variety of computing platforms, in particular of platforms different from the one on which the checkpoint image was created. We will describe the mechanism of creating checkpoint images of Geant4 simulation jobs with AthenaMP (the multi-process version of the ATLAS data simulation, reconstruction and analysis framework Athena) and the usage of these images for running ATLAS Simulation production jobs on volunteer computing resources (ATLAS@Home) and on Supercomputers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Tiny Triplet Finder as a Versatile Track Segment Seeding Engine for Trigger Systems

In high energy physics experiment trigger systems, track segment seeding is a resource consuming function and the primary reason is the computing complexity of the segment finding process. As the Moore's Law is reaching its physical limit, reducing computing complexity should be carefully considered, rather than keep piling up silicon resources. The Tiny Triplet Finder is a scheme that reduces the computing complexity of the segment seeding. As a proof of concept, a 3D track segment seeding engine core based on the Tiny Triplet Finder has been implemented and tested in a low-cost FPGA device. The seeding engine is designed to preselect and group hits (stubs) from detector layers to feed subsequent track fitting stage. The seeding engine consists of a Hough transform space for r-z view and a Tiny Triplet Finder for r-phi view to implement 3D constraints. The seeding engine is organized as a pipeline so that each hit is processed in a single clock cycle. Taking advantage of the register-like storage block scheme which enables effectively resetting of a block RAM within a single clock cycle, clearing or refreshing the seeding engine takes only one clock cycles between two events. The Tiny Triplet Finder is also a generic coincidence finding scheme that can be used for many tasks. As a versatility demonstration, track segment finding performances for two distinctive detector geometries are tested in our seeding engine. In a collider barrel-layer geometry, the fake segment rates are studied for 3D (i.e., both r-phi and r-z views) and 2D (i.e., r-phi or r-z view only) configurations for high hit multiplicity events (>4000 hits/layer in the barrel region). Another detector geometry contains strip plane layers with timing information. The numbers of coincidences, both real or fake, with or without timing ("3D" or "2D") information at various hit multiplicities are studied.

43 PARTICLE ACCELERATORS↗