Search NASASearch

SEARCH · Search NASA

Results for “detector modelling and simulations I”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

GPU-friendly surface model for Monte-Carlo detector simulations

The demands for Monte-Carlo simulation are drastically increasing with the Large Hadron Collider’s high-luminosity upgrade, and are expected to exceed the currently available compute resources. At the same time, modern high-performance computing has adopted powerful hardware accelerators, particularly GPUs. The AdePT and Celeritas projects aim to address the demanding computational needs by leveraging these heterogeneous computing architectures. While both have successfully ported realistic detector simulations to GPUs using the VecGeom library, the complexity of geometry modeling emerged as a bottleneck. Thread divergence and high register usage were degrading the GPU performance. Therefore, a new, GPU-friendly surface-based model has been introduced in the VecGeom library that decomposes the divergent code of the 3D primitive solids into simpler and more balanced surface algorithms. In this work, we present the latest developments, focusing on the additions required to efficiently model complex setups like the CMS Phase-2 geometry. This includes memory reduction techniques, and adding accelerating structures for faster traversal.

Diederichs, Severin [CERN]

HEAO-1 analysis of Low Energy Detectors (LED)

The activities at Penn State University are described. During the period Oct. 1990 to Dec. 1991 work on HEAO-1 analysis of the Low Energy Detectors (LED) concentrated on using the improved detector spectral simulation model and fitting diffuse x-ray background spectral data. Spectral fitting results, x-ray point sources, and diffuse x-ray sources are described.

Nousek, John A.

Simulating the X-Ray Image Contrast to Set-Up Techniques with Desired Flaw Detectability

The paper provides simulation data of previous work by the author in developing a model for estimating detectability of crack-like flaws in radiography. The methodology is being developed to help in implementation of NASA Special x-ray radiography qualification, but is generically applicable to radiography. The paper describes a method for characterizing X-ray detector resolution for crack detection. Applicability of ASTM E 2737 resolution requirements to the model are also discussed. The paper describes a model for simulating the detector resolution. A computer calculator application, discussed here, also performs predicted contrast and signal-to-noise ratio calculations. Results of various simulation runs in calculating x-ray flaw size parameter and image contrast for varying input parameters such as crack depth, crack width, part thickness, x-ray angle, part-to-detector distance, part-to-source distance, source sizes, and detector sensitivity and resolution are given as 3D surfaces. These results demonstrate effect of the input parameters on the flaw size parameter and the simulated image contrast of the crack. These simulations demonstrate utility of the flaw size parameter model in setting up x-ray techniques that provide desired flaw detectability in radiography. The method is applicable to film radiography, computed radiography, and digital radiography.

Koshti, Ajay M.

Performance Analysis of a Hardware Implemented Complex Signal Kurtosis Radio-Frequency Interference Detector

Radio-frequency interference (RFI) is a known problem for passive remote sensing as evidenced in the L-band radiometers SMOS, Aquarius and more recently, SMAP. Various algorithms have been developed and implemented on SMAP to improve science measurements. This was achieved by the use of a digital microwave radiometer. RFI mitigation becomes more challenging for microwave radiometers operating at higher frequencies in shared allocations. At higher frequencies larger bandwidths are also desirable for lower measurement noise further adding to processing challenges. This work focuses on finding improved RFI mitigation techniques that will be effective at additional frequencies and at higher bandwidths. To aid the development and testing of applicable detection and mitigation techniques, a wide-band RFI algorithm testing environment has been developed using the Reconfigurable Open Architecture Computing Hardware System (ROACH) built by the Collaboration for Astronomy Signal Processing and Electronics Research (CASPER) Group. The testing environment also consists of various test equipment used to reproduce typical signals that a radiometer may see including those with and without RFI. The testing environment permits quick evaluations of RFI mitigation algorithms as well as show that they are implementable in hardware. The algorithm implemented is a complex signal kurtosis detector which was modeled and simulated. The complex signal kurtosis detector showed improved performance over the real kurtosis detector under certain conditions. The real kurtosis is implemented on SMAP at 24 MHz bandwidth. The complex signal kurtosis algorithm was then implemented in hardware at 200 MHz bandwidth using the ROACH. In this work, performance of the complex signal kurtosis and the real signal kurtosis are compared. Performance evaluations and comparisons in both simulation as well as experimental hardware implementations were done with the use of receiver operating characteristic (ROC) curves. The complex kurtosis algorithm has the potential to reduce data rate due to onboard processing in addition to improving RFI detection performance.

microwaves

Performance Analysis of a Hardware Implemented Complex Signal Kurtosis Radio-Frequency Interference Detector

Radio-frequency interference (RFI) is a known problem for passive remote sensing as evidenced in the L-band radiometers SMOS, Aquarius and more recently, SMAP. Various algorithms have been developed and implemented on SMAP to improve science measurements. This was achieved by the use of a digital microwave radiometer. RFI mitigation becomes more challenging for microwave radiometers operating at higher frequencies in shared allocations. At higher frequencies larger bandwidths are also desirable for lower measurement noise further adding to processing challenges. This work focuses on finding improved RFI mitigation techniques that will be effective at additional frequencies and at higher bandwidths. To aid the development and testing of applicable detection and mitigation techniques, a wide-band RFI algorithm testing environment has been developed using the Reconfigurable Open Architecture Computing Hardware System (ROACH) built by the Collaboration for Astronomy Signal Processing and Electronics Research (CASPER) Group. The testing environment also consists of various test equipment used to reproduce typical signals that a radiometer may see including those with and without RFI. The testing environment permits quick evaluations of RFI mitigation algorithms as well as show that they are implementable in hardware. The algorithm implemented is a complex signal kurtosis detector which was modeled and simulated. The complex signal kurtosis detector showed improved performance over the real kurtosis detector under certain conditions. The real kurtosis is implemented on SMAP at 24 MHz bandwidth. The complex signal kurtosis algorithm was then implemented in hardware at 200 MHz bandwidth using the ROACH. In this work, performance of the complex signal kurtosis and the real signal kurtosis are compared. Performance evaluations and comparisons in both simulation as well as experimental hardware implementations were done with the use of receiver operating characteristic (ROC) curves.

radiometers

Advancing set-conditional set generation: Diffusion models for fast simulation of reconstructed particles

The computational intensity of detector simulation and event reconstruction poses a significant difficulty for data analysis in collider experiments. This challenge inspires the continued development of machine learning techniques to serve as efficient surrogate models. We propose a fast emulation approach that combines simulation and reconstruction. In other words, a neural network generates a set of reconstructed objects conditioned on input particle sets. To make this possible, we advance set-conditional set generation with diffusion models. Using a realistic, generic, and public detector simulation and reconstruction package (COCOA), we show how diffusion models can accurately model the complex spectrum of reconstructed particles inside jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. Here, the measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly

The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.

Physics

Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

43 PARTICLE ACCELERATORS

GEANT4 code for DANCE with NEUANCE detector-response simulations

A new GEANT4 model for DANCE with NEUANCE has been developed to account for the change in the DANCE configuration when NEUANCE is installed. In this model, the energy resolution and the shape of the threshold of the individual DANCE detectors are used as an input to provide realistic representation of the measured γ-ray spectra. In addition, the distance from each detector to the target is defined in an input file as well as the physical presence of the a detector in the DANCE and NEUANCE arrays. The azimuthal angle of NEUANCE is also an external parameter to be tuned to represent the measurement. Simulated spectra are compared with measurements with standard γ-ray calibrated sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

The Urban Deployment Model: A Toolset for the Simulation and Performance Characterization of Radiation Detector Deployments in Urban Environments

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

Machine learning for single-ended event reconstruction in PROSPECT experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

47 OTHER INSTRUMENTATION

Unifying simulation and inference with normalizing flows

There have been many applications of deep neural networks to detector calibrations and a growing number of studies that propose deep generative models as automated fast detector simulators. We show that these two tasks can be unified by using maximum likelihood estimation (MLE) from conditional generative models for energy regression. Unlike direct regression techniques, the MLE approach is prior independent and non-Gaussian resolutions can be determined from the shape of the likelihood near the maximum. Using an ATLAS-like calorimeter simulation, we demonstrate this concept in the context of calorimeter energy calibration. Published by the American Physical Society 2025

Hadronic calorimiters

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS

Estimating Cosmic Ray Spectral Parameters from Simulated Detector Responses

A simple power law model consisting of a single spectral index al is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 100 TeV, with a transition at kink energy Ek to a steeper spectral index a2>al above Ek. The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, Leonard

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION