Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large mass single electron resolution detector for dark matter and neutrino elastic interaction searches

Large mass single electron resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CEvNS). In this paper we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of ~ 1e - /h + pair and a leakage current on the order of 10 -16 A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CEvNS like searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Minimum Resolution Requirements for Gamma Identification Algorithms

Each year there are millions of dollars spent on the research and production of high-resolution detectors. This research indicates that the pursuit of higher resolution detectors is not always necessary. The terminal resolution of a NaI detector, or highest detector resolution, at which identification algorithms fail to identify highly enriched uranium (HEU) was evaluated using GADRAS, Genie, and GammaVision. GADRAS employs a template matching algorithm, while Genie and GammaVision utilize a mathematical approach for peak search and identification. The NaI spectra utilized for evaluation were generated using the GADRAS Inject tab and source modeling functions. Each spectrum included terrestrial and cosmic background from Dallas, TX. The resolutions for each spectrum were increased from a default 8.92% to a point where each algorithm would fail to identify 235 U from a HEU source. Six different source configurations were used in this research: bare HEU, 50% shielded HEU, 90% shielded HEU, bare HEU with an interference source of 99 mTc, bare HEU with 99 mTc both shielded 50%, and bare HEU with 99 mTc both shielded 90%. T

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of the Workshop on M400 High-Resolution CZT Detector Safeguards Applications

In September 2023, the US Department of Energy (DOE) National Nuclear Security Administration’s (NNSA’s) Office of Nonproliferation and Arms Control sponsored a workshop on M400 high-resolution cadmium zinc telluride (CZT) detector safeguards applications under its Safeguards Technology Development Program. The workshop brought together internationally recognized subject matter experts (SMEs) in the field of gamma spectrometry and uranium/plutonium isotopic analysis and experts from H3D Inc. (H3D), the vendor for M400.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning

The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating μ + →e + γ decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR (μ + →e + γ) ≤ 4.2×10 –13 at 90% confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of 6×10 –14 . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG (7×10 7 μ + /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for measuring the time variation of astrophysical neutrino sources at dark matter detectors

We study the prospects for measuring the time variation of solar and atmospheric neutrino fluxes at future large-scale xenon and argon dark matter detectors. For solar neutrinos, a yearly time variation arises from the eccentricity of Earth’s orbit and, for charged current interactions, from a smaller energy-dependent day-night variation due to flavor regeneration as neutrinos travel through Earth. For a 100-ton xenon detector running for ten years with a xenon-136 fraction of ≲ 0.1 % , in the electron recoil channel a time-variation amplitude of about 0.8% is detectable with a power of 90% and the level of significance of 10%. This is sufficient to detect time variation due to eccentricity, which has amplitude of ∼ 3 % . In the nuclear recoil channel, the detectable amplitude is about 10% under current detector resolution and efficiency conditions, and this generally reduces to about 1% for improved detector resolution and efficiency, the latter of which is sufficient to detect time variation due to eccentricity. Our analysis assumes both known and unknown periods. We provide scalings to determine the sensitivity to an arbitrary time-varying amplitude as a function of detector parameters. Identifying the time variation of the neutrino fluxes will be important for distinguishing neutrinos from dark matter signals and other detector-related backgrounds and extracting properties of neutrinos that can be uniquely studied in dark matter experiments. Published by the American Physical Society 2024

Zhuang, Yi (ORCID:0000000277138724)↗

Particle track classification using quantum associative memory

Pattern recognition algorithms are commonly employed to simplify the challenging and necessary step of track reconstruction in sub-atomic physics experiments. Aiding in the discrimination of relevant interactions, pattern recognition seeks to accelerate track reconstruction by isolating signals of interest. In high collision rate experiments, such algorithms can be particularly crucial for determining whether to retain or discard information from a given interaction even before the data is transferred to tape. As data rates, detector resolution, noise, and inefficiencies increase, pattern recognition becomes more computationally challenging, motivating the development of higher efficiency algorithms and techniques. Quantum associative memory is an approach that seeks to exploits quantum mechanical phenomena to gain advantage in learning capacity, or the number of patterns that can be stored and accurately recalled. Here, we study quantum associative memory based on quantum annealing and apply it to the particle track classification. We focus on discrimination models based on Ising formulations of quantum associative memory model (QAMM) recall and quantum content-addressable memory (QCAM) recall. We characterize classification performance of these approaches as a function detector resolution, pattern library size, and detector inefficiencies, using the D-Wave 2000Q processor as a testbed. Discrimination criteria is set using both solution-state energy and classification labels embedded in solution states. We find that energy-based QAMM classification performs well in regimes of small pattern density and low detector inefficiency. In contrast, state-based QCAM achieves reasonably high accuracy recall for large pattern density and the greatest recall accuracy robustness to a variety of detector noise sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Isotopic gamma lines for identification of shielding materials

Identifying the constituting materials of concealed objects is crucial in a wide range of sectors, such as medical imaging, geophysics, nonproliferation, national security investigations, and so on. Existing methods face limitations, particularly when multiple materials are involved or when there are challenges posed by scattered radiation and large areal mass. Here we introduce a novel brute-force statistical approach for material identification using high spectral resolution detectors, such as HPGe. The method relies upon updated semianalytic formulae for computing uncollided flux from source of gamma radiation, shielded by a sequence of nested spherical or cylindrical materials. These semianalytical formulae make possible rapid flux estimation for material characterization via combinatorial search through all possible combinations of materials, using a high-resolution HPGe counting detector. An important prerequisite for the method is that the geometry of the objects is known (for example, from X-ray radiography). We demonstrate the viability of this material characterization technique in several use cases with both simulated and experimental data in spherical geometry.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of online pulse-finding algorithms for the Mu2e Stopping Target Monitor and an evaluation of the signal to background ratio for the Mu2e stopped-muon rate determination

This thesis presents a determination of the acceptance of the Mu2e Stopping Target Monitor (STM) detector for both signal and background events. The rate of X-rays of a specific energy in the STM is used to determine the rate of stopped muons in the aluminium stopping target, which is used as the normalisation for all Mu2e measurements, particularly the branching ratio for a charged lepton flavour violating (cLFV) process. The acceptance for the 347\,keV $2p-1s$ aluminium signal X-ray is determined to be $(8.03 \pm 0.05) \times 10^{-10}$\,cm$^{-2}$ and the acceptance for the background photons (at 347\,keV) to be $(3.19 \pm 0.21) \times 10^{-8}$\,cm$^{-2}$. This results in a signal-to-background ratio of approximately two which is significantly higher than had previously been estimated. These signal-to-background rates are used to determine the time required to achieve a statistical uncertainty of 10\% on the number of 347\,keV X-rays as a function of the detector resolution and back ground rate. For a resolution of 2\,keV, and the background rate determined in this thesis, approximately one minute of data is required. The three corrections needed to be applied to the measured 347\,keV rate to determine the rate of stopped muons are also determined and potential sources of bias arising from the background shape, background fit range and energy calibration are investigated and found to be insignificant. The raw energy of the particles in the STM detector comes from a 16-bit ADC digitising at $\sim 300$\,MHz. It is not possible to store all the raw digitisations and online algorithms have been developed to rapidly select pulses in the detector and reconstruct their energy. The performance of these algorithms has been characterised with simulated data as a function of detector rate and resolution and optimum operating points for the algorithms have been defined. The integrity of the algorithms has also been demonstrated and characterised on test-beam data at high r ates and with radioactive sources at low rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗