Search NASA⌕ Search

SEARCH · Search NASA

Results for “detrainment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Causal Directions Matter: How Environmental Factors Drive Convective Cloud Detrainment Heights

This study investigates how environmental factors influence the level of maximum detrainment (LMD) in deep convective clouds. Through a novel application of the Linear Non‐Gaussian Acyclic Model (LiNGAM), we discover causal structures between environmental variables and LMD, observed at six tropical sites operated by the Atmospheric Radiation Measurement (ARM) user facility. LiNGAM effectively identifies causal directions among variables of interest, revealing robust relationships such as those among the lifting condensation level (LCL), level of free convection (LFC), and convective inhibition (CIN), aligning with prior knowledge. Relative humidity is shown to directly influence LMD; however, this relationship exhibits strong nonlinearity and becomes difficult to detect when the contrast between oceanic and continental environments is excluded from the analysis. This study highlights the importance of establishing causal relationships before performing statistical inference.

54 ENVIRONMENTAL SCIENCES↗

Simplified Approximations of Direct Cumulus Entrainment and Detrainment

Abstract In recent years, direct calculations of simulated cumulus entrainment and detrainment have facilitated new physical insights into these highly elusive but critically important processes. However, these calculations require substantial computational resources that may limit their widespread usage. To facilitate such calculations, two simplified approximations of direct cumulus entrainment and detrainment are examined herein. The first approximation, termed the “semidirect” method, follows a standard bulk approach but makes more realistic assumptions about the sources of entrained and detrained air near the cloud edges. In contrast, the second approximation (the “projection” method) uses the governing equations of motion to project whether grid points near the cloud edge will entrain or detrain as the mean cloud ascends by one grid point. Verification exercises using large-eddy simulations reveal that both methods generally agree better with corresponding direct entrainment/detrainment estimates than the traditional bulk formulation, with the projection method outperforming the semidirect method. The two methods can be used in a synergistic fashion, with the semidirect method helping to optimize the projection method, to suit a wide range of applications. Because the latter incorporates the essential dynamics of entrainment and detrainment at the local scale, it can be used to gain physical insight into the causal mechanisms regulating these complex processes.

Meteorology & Atmospheric Sciences↗

Entrainment, Detrainment, and Dilution of Dry and Moist Atmospheric Thermals

Here this study examines the entrainment, detrainment, and dilution of dry and moist (cloud) atmospheric thermals in large-eddy simulations. In a neutrally stable environment (with respect to dry dynamics), moist thermals have an increase in radius R with thermal height z t (α ≡ dR/dz t ) about 4 times smaller compared to dry thermals when density stratification is considered and ~2.4 times smaller without density stratification (i.e., applying the Boussinesq approximation). An analytic expression relating α to several dimensionless parameters is derived from the thermal impulse–circulation relation to clarify the factors impacting α. This expression shows that the difference in buoyancy structure between moist and dry thermals, with buoyancy concentrated in the central cores of moist thermals owing to latent heating, explains their smaller spreading rates. Individual contributions of entrainment and detrainment are analyzed using a direct parcel-based approach in the simulations. Moist thermals have similar fractional detrainment but much smaller fractional entrainment rates compared to dry thermals, consistent with the differences in α. Despite having smaller α, moist thermals are similarly dilute (quantified by a passive tracer) as dry thermals because of their greater mixing efficiency with the environment. Thus, moist thermals are substantially dilute but expand much less in size/volume as they rise compared to dry thermals. The α values for moist thermals in (dry) neutral and statically stable environments are similar, but fractional entrainment and especially detrainment rates are greater in the stable environment. Large detrainment rates are associated with a breakdown of the broader thermal vortex ring structure, especially with low environmental relative humidity, attributed in part to evaporation and buoyancy reversal.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a New Approach for Entrainment and Detrainment Rate Estimation

Entrainment and detrainment rates (ε and δ) constitute the most critical free parameters in mass flux schemes commonly employed for cumulus parameterizations. Recently, Zhu et al. (2021) introduced a new approach that utilizes aircraft observations to simultaneously estimate ε and δ for cumulus clouds, overcoming the limitation of other observation-based approaches that solely yield ε without offering insights into δ. This study aims to comprehensively evaluate the reliability of this new approach. First, evaluation using an Explicit Mixing Parcel Model demonstrates the capability of the new approach to back-calculate predetermined ε and δ based on the physical properties before and after the entrainment mixing. Second, evaluation using large-eddy simulations illustrates that the new approach yields consistent ε and δ profiles compared to the traditional approach. Sensitivity tests indicate a weak sensitivity of the estimated δ with the new approach to the entrained air source. A decrease in the proportion of cloudy air in the assumed detrained air leads to a reduction in the estimated δ, while ε remains unaffected. Finally, the most appropriate assumptions for entrained and detrained air are discussed. Estimating ε for cumulus parameterizations involves acquiring ambient air more than 500 m away from the cloud edge as entrained air. Due to implicit mean field approximations in the traditional approach, determining the optimal assumption for detrained air properties proves challenging. Finally, this study confirms the reliability of the new approach in estimating ε and δ, providing confidence in its application to extensive observational data and advancement in parameterization.

54 ENVIRONMENTAL SCIENCES↗

Factors Controlling Precipitation Onset and Maintenance: Inferences From Large Eddy Simulations of Two Afternoon Deep Convective Regimes Over Amazon

To investigate the environmental factors controlling the onset and maintenance of afternoon precipitation over tropical rainforests, two contrasting cases are created for large eddy simulations (LES) using GoAmazon observations: one features a single-pulse rain dissipating quickly in earlier afternoon, while the other shows double pulses lasting until evening. For these two specific cases under consideration, LES confirms that early-morning relative humidity dominates afternoon rain patterns. The attributed impacts are distinct: moisture determines the rain onset timing while temperature affects the peak rain intensity. Single-pulse day observes one round of strong precipitation and cold pools, which further suppresses convection. On double-pulse day, the first precipitation peak results from an intermediate development of congestus clouds, whose detrainment leads to a gradual moistening of the lower-to-middle troposphere. This behavior of convection favors a second pulse of stronger precipitation with more convective organization, whose development decouples from surface fluxes and sustains until evening.

Amazon↗

Dependencies of Simulated Convective Cell and System Growth Biases on Atmospheric Instability and Model Resolution

Abstract This study evaluates convective cell properties and their relationships with convective and stratiform rainfall within a season‐long convection‐permitting weather research and forecasting simulation over central Argentina using radar, satellite, and radiosonde measurements from the RELAMPAGO‐CACTI field campaign. The simulation slightly underestimates radar‐estimated rainfall over the ∼3.5‐month evaluation period but underestimates stratiform rainfall by 46% and overestimates convective rainfall by 43%. As convective available potential energy (CAPE) increases, the convective rainfall overestimation decreases, but the stratiform rainfall underestimation increases such that the contribution of convective to total rainfall remains constantly high biased by ∼26%. Overestimated convective rainfall arises from the simulation generating 2.6 times more precipitating convective cells (14,299) than observed by radar (5,662) despite similar observed and simulated cell growth processes, with relatively wide cells contributing mostly to excessive convective rainfall. Relatively shallow cells, typically reaching heights of 4–7 km, contribute most to the cell number bias. This cell number bias increases as CAPE decreases, potentially because cells and their updrafts become narrower and more under‐resolved as CAPE decreases. The gross overproduction of precipitating shallow cells leads to overly efficient precipitation and inadequate detrainment of ice aloft, thereby diminishing the formation of robust stratiform rainfall regions. Decreasing model horizontal grid spacing from 3 to 1 or 0.333 km for low (<300 J kg −1 ) and high CAPE (>1,000 J kg −1 ) cases results in minimal change to cell number, depth, and convective‐to‐stratiform partitioning biases. This suggests that improving prediction of these convective properties depends on factors beyond solely increasing model resolution.

54 ENVIRONMENTAL SCIENCES↗

An Optimized Parameterization of Sub‐Grid Scale Advection for Convection Permitting Models

Convection‐permitting models (CPMs) explicitly resolve deep convection yet under‐resolve the organized lateral exchanges among drafts and their environment that control entrainment/detrainment, precipitation efficiency, and mesoscale structure. In this work, we introduce the Optimized Advection Scheme (OAS), which introduces a small rotation of the Cartesian frame of reference for the horizontal winds relative to other variables used in advection that induces cross‐gradient transport to mimic under‐resolved convective mixing. The rotation angle is selected to minimize the Kullback–Leibler divergence between the simulated and satellite observed precipitation intensity distributions, yielding a physically consistent perturbation that is computationally inexpensive and portable. Optimized Advection Scheme is implemented in WRF and evaluated over Amazon (April 2014). It shifts precipitation–precipitable‐water joint distributions toward lighter rain, reduces overly intense rates, and improves mesoscale convective system (MCS) lifetime and propagation. Mechanistically, the added cross‐gradient transport promotes convective detrainment and environmental mixing, which cools and moistens the mid‐troposphere, weakens downward momentum transport, alleviates excessive downwelling shortwave biases, and warms the surface temperature. The optimized rotation angle yields comparable improvements at 4‐km and 1‐km grid spacing, demonstrating resolution‐independent benefits across the CPM gray zone. By targeting the dynamical root of under‐mixed convective circulations, rather than tuning model microphysics or closures, OAS delivers robust, scale‐aware improvements in precipitation statistics, cloud vertical structure, and characteristics of MCS (MCSs), offering a practical pathway to more reliable CPM simulations for weather and climate applications.

CPM↗

High-resolution lidar observations of sedimentation-induced size sorting of droplets near a laboratory cloud top

Cloud optical properties and precipitation, which are crucial to weather and climate, are strongly influenced by cloud microphysical properties that are still poorly understood. Here, we develop a high-resolution time-correlated single-photon-counting lidar and apply it to observe cloud microphysical properties at one-centimeter range resolution in a convection chamber under well-controlled conditions. Together with concurrent in-situ measurements and theoretical analysis, our lidar observations indicate that although turbulent mixing tends to homogenize the cloud in the bulk region, entrainment and sedimentation cause inhomogeneities in droplet concentrations near the cloud top. Specifically, the topmost region is directly affected by entrainment, and lidar profiles show clear evidence of entrained air and detrained cloud filament. The transition region below exhibits vertical size sorting of cloud droplets caused by sedimentation. Our results suggest that using a single sedimentation velocity for all cloud droplets, as is done in many atmospheric models, overlooks key physics relevant to the microphysical structure near the cloud top. In conclusion, our conceptual model used to describe these measurements can serve as a step toward improving the current modeling of processes in the cloud top region.

54 ENVIRONMENTAL SCIENCES↗

Hydrometeor Transport and the Stratiform Water Budget in Amazonian Mesoscale Convective Systems

A significant portion of precipitation falls within the stratiform regions of mesoscale convective systems (MCSs). These regions are formed from convective clouds that have either weakened and formed a horizontally stratified structure or have advected hydrometeors to form a trailing-stratiform region, with further precipitation growth promoted by in situ dynamical and microphysical processes. Green Ocean Amazon 2014/5 (GoAmazon2014/5) field campaign observations are used to quantify the stratiform water budget of six MCSs (three each from the wet and dry seasons) utilizing the framework from Leary and Houze, with an emphasis on the transfer of hydrometeors (C A ) from the convective to the stratiform regions. The storms were predominantly leading-line/trailing-stratiform MCSs, but two had embedded convection in the stratiform region, which can complicate water budget calculations. A pulse-like pattern with a mean interval of 21 min occurs in C A during each storm resulting from a lag between the initial convective updrafts and the subsequent hydrometeor transport and sedimentation in the stratiform region. Here, the peaks in C A were followed by peaks in hydrometeor growth associated with the mesoscale updraft (C mu ) in the stratiform region. Averaged over the six storms, the positive contributions of C A and C mu to the stratiform water budget were roughly equal, although storm-to-storm variations existed. Negative contributions from evaporation below cloud base in the mesoscale downdraft and detrainment from the stratiform region into the nonprecipitating anvil cloud and environment accounted for 53% and 21% of the sum of C A and C mu , respectively, resulting in a mean stratiform region precipitation efficiency of 26%.

54 ENVIRONMENTAL SCIENCES↗

Collaborative Proposal: Improving understanding of the internal structure and dynamics of deep convection using ARM observations and large eddy simulations

Recent observational and large eddy simulation (LES) modeling studies have nearly unanimously supported the view of deep cumulus convection being composed of a series of quasi-spherical bubbles of buoyant air, known as moist thermals. Despite the prevalence of moist thermals in deep convection, a comprehensive theory for the dynamics of these structures is lacking. Most current conceptual models for cumulus convection are based on canonical scaling theories for dry thermals or plumes; however, there is considerable evidence that the behavior of moist thermals differs markedly from these theories. Furthermore, the theoretical basis for most cumulus parameterizations originates from the plume conceptual model, and therefore these parameterizations are inconsistent with the real structure of moist convection. Motivated by the aforementioned knowledge gaps, this “end-to-end” research effort use theory, observations, numerical simulations, and direct improvements to the Zhang-McFarlane (ZM) convection scheme in the global climate Community Atmosphere Model (CAM) to address the following research questions: What key environmental parameters determine whether or not shallow convection will transition into deep convection, in the context of thermal-like updrafts? What factors regulate the size of thermals within cumulus updrafts? How does vertical wind shear influence thermal behavior, and as a consequence, vertical velocity and mass flux profiles and the shallow-to-deep convective transition? What are the critical processes that determine updraft vertical velocities and their connection to the vertical mass flux profile for thermal-like updrafts? Idealized LES modeling will be used in conjunction with theoretical models for the core properties of thermal-like updrafts to better understand key processes that regulate thermal ascent rates and entrainment properties. Thermal-tracking procedures will be used to characterize the behavior of thermals within the LES, and recently developed direct measures of entrainment and detrainment will be used to quantify entrainment/detrainment rates. Building from these results, we will analyze the structure of moist thermals from hemispheric range-height indicator scans taken during the Atmospheric Radiation Measurement Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign, and from “real case” LES of CACTI events. This combined modeling and observational analysis will provide essential validation for the existing body of research on moist thermal dynamics, which is based primarily on modeling studies. With the insight gained from the aforementioned activities, we will modify the Zhang-McFarlane convection scheme to improve its representation of updraft vertical velocity and entrainment rate profiles. These process-level changes will be tested in the Community Atmosphere Model to assess the impact on global climate simulations.

54 ENVIRONMENTAL SCIENCES↗

Aerosol-deep convection interaction based on joint cell-thermal tracking in Large Eddy Simulations during the TRACER campaign

In cumulus clouds, aerosol concentrations control cloud droplet concentrations, modifying cloud radiative properties, precipitation processes, and cloud electrification. However, mechanisms of aerosol-deep convection interactions are not well understood due to complex cloud dynamics and microphysics. We investigate the interaction of aerosols with isolated deep convection using Large Eddy Simulations of two cases during the TRacking Aerosol Convection interactions ExpeRiment (TRACER) near Houston, Texas, using a joint cell-thermal tracking algorithm. Cumulus thermals are droplet generators, since supersaturation and droplet nucleation coincide with thermal centers, where the strongest updrafts occur. Primary ice crystal formation does not take place inside thermals, but at layers where previous thermals detrained moisture. As subsequent thermals containing supercooled droplets penetrate these layers, hail and graupel form at or near these thermals. Higher aerosol concentrations result in higher droplet concentrations that suppress drizzle, delay warm rain processes, and transport more moisture aloft. This increases snow and ice amount, as well as graupel and hail, leading to more lightning. Polluted thermals initiate at slightly higher altitudes, and are slightly larger and faster, suggesting a weak invigoration. We also find more thermals per cell, but fewer isolated cells, since convection is more aggregated and intense, especially near the end of the 24 h simulation. Non-linear mesoscale feedback likely triggered by temperature and moisture responses to aerosol-thermal interactions causes the aggregation. Time-lagged aerosol-reinitialization experiments show that the mesoscale response is the predominant forcing for the invigoration. These changes happen within one day, on a smaller scale than previously suggested.