Search NASA⌕ Search

SEARCH · Search NASA

Results for “dew point”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of the thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery efficiency, and the acid dew point is a key parameter for this optimization. In this work, we analyze and discuss the theory of the sulfuric acid condensation process and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface, and the surface temperature of the window is slowly decreased until condensation is first observed, yielding an accurate measurement of the dew point. The basis of the instrument is that a collimated beam from a diode laser generates scattered light when encountering surface condensate, and a sophisticated array detector is used to sensitively monitor the light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, we propose a calibration system based on a liquid bubbler, which can generate a stable gas flow with known sulfuric acid dew point, to test the dew point meter. Test results show that the dew point meter can accurately measure the acid dew point over a wide range.

Cheng, Mao↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

Impact of air distribution on dew point evaporative cooler thermal performance

A new geometry of the dew-point indirect evaporative cooler structure was proposed which enables uniform distribution of water in the working channels and application in traditional air handling units. This arrangement requires a complicated structure of the product channel in which the air is cooled. Further, the airflow direction changes and complicated structure it is associated with local losses affecting the total pressure loss. High-pressure drop limits the use of this dew point evaporative cooler as an alternative source of cooling. Therefore, a verified method based on numerical fluid dynamics (CFD) was used to determine the pressure drop and air distribution in the exchanger. The combination of the CFD method and modified epsilon-NTU allows the thermal performance of the device including the uniformity of air distribution, cooling capacity, and coefficient of performance to be determined. Finally, the appropriate exchanger dimensions, i.e., the channel height, or final distribution regulation may be found depending on the exchanger application.

42 ENGINEERING↗

Analysis of heat and mass transfer potential of a dew-point cooling tower in different climatic conditions

In this study, the performance of the Dew-Point Cooling Tower (DPCT) was analyzed for different factors in a variety of climate conditions. For this purpose, a dedicated numerical model describing heat and mass transfer processes was developed and validated. The results of the numerical simulations allowed to analyze the potential of utilizing the heat and mass transfer process with the dew-point phenomenon for water cooling. It was established that the operational parameters that have a high impact on the performance of the DPCT are: inlet water temperature and inlet air humidity ratio. It was also established that DPCT achieves the highest COP and Specific Cooling Capacity for cold subtropical highland climates and that it achieves highest Wet-bulb Effectiveness for monsoon-influenced humid subtropical climates. In conclusion, the regions where all the efficiency factors achieved above-average values included warm, arid, and desert climates.

42 ENGINEERING↗

Dew Point Simulation and Analysis of the Heat Melt Compactor Gas Effluent

The effluent gases and water vapor of the Trash Compaction and Processing System (TCPS) can be vented through the Vacuum Exhaust System (VES) if requirements are met. One of the constraints in this venting scenario is the dew point of the exhaust gases disposed into the VES must be less than 15.5 °C. With simulations using Aspen Plus and the effluent gas sample results of the Heat Melt Compactor (HMC), flash calculations were conducted in the modeling study to calculate the feed temperature and dew point at fixed pressures. Saturated vapor curves were produced and provided a preliminary result on optimal feed conditions that satisfy the dew point and vapor-phase only requirements after flashing across the throttle valve towards the VES.

trash↗

Analytical investigation of the dew point water recovery system with potential application for drinking water production

The article presents the analytical investigation of the Dew Point Water Recovery (DPWR) system with potential application for drinking water production. Four different configurations of the DPWR system were proposed, differing in the number and type of dew point cooling exchangers used, and their operation was described using a validated convective heat transfer coefficient mathematical model. It was found that the three stage configu-ration of the DPWR system with a regenerative exchanger has the best water recovery performance, while the three stage configuration with a counter-flow exchanger has the best ratio of energy supplied to the system in relation to the amount of water produced. It was also found that the DPWR system can operate in a wide range of operating conditions with a specific electric energy consumption reaching below 0.9 kWh/m 3 and GOR in the range of 0.36-2.16. What distinguishes the DPWR system from other methods of drinking water production is the ability to work without an additional source of thermal energy apart from the energy of the air supplied to the system. Thanks to this property, the system has the potential to fill the technological gap of a low-energy and easily accessible method of drinking water production.

42 ENGINEERING↗

High Response Dew Point Measurement System for a Supersonic Wind Tunnel

A new high response on-line measurement system has been developed to continuously display and record the air stream dew point in the NASA Lewis 10 x 10 supersonic wind tunnel. Previous instruments suffered from such problems as very slow response, erratic readings, and high susceptibility to contamination. The system operates over the entire pressure level range of the 10 x 10 SWT, from less than 2 psia to 45 psia, without the need for a vacuum pump to provide sample flow. The system speeds up tunnel testing, provides large savings in tunnel power costs and provides the dew point input for the data-reduction subroutines which calculate test section conditions.

Blumenthal, Philip Z.↗

Transport-induced shifts in condensate dew-point and composition in multicomponent systems with chemical reaction

Partial heterogeneous condensation phenomena in multicomponent reacting systems are analyzed taking into consideration the chemical element transport phenomena. It is demonstrated that the dew-point surface temperature in chemically reactive systems is not a purely thermodynamic quantity, but is influenced by the multicomponent diffusion and Soret-mass diffusion phenomena. Several distinct dew-points are shown to exist in such systems and, as a result of transport constraints, the 'sharp' locus between two chemically distinct condensates is systematically moved to a difference mainstream composition.

Rosner, D. E.↗

Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983

A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

Fishman, Jack↗

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of dew-point detection for quantitative measurement of sweating rate

A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

Brengelmann, G. L.↗

Dew point meter, components thereof, and methods of use thereof

In one aspect, the present disclosure is directed to a sample cell for a dew point meter, the sample cell comprising: a flow channel configured to receive a gas sample, the flow channel comprising: a non-mirror window surface, wherein the flow channel is configured to allow a first optical beam originating from an optical source to impinge on the non-mirror window surface and output a second optical beam from the non-mirror window surface towards an optical detector.

Cheng, Mao↗

Overview of On-Line Optical Measurements at High Pressure for Flue Gases, Particulates and Acid-dew Point of Pressurized Oxy-Combustion

Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.

Cheng, Mao↗