Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sounding-Diagnosed Convective Environments and Preliminary Energy Budgets Diagnosed during the TRMM Field Campaigns

An overview of mean convective thermodynamic and wind profiles for the Tropical Rainfall Measuring Mission (TRMM) Large Scale Biosphere-Atmosphere Experiment (LBA) and Kwajalein Experiment (KWAJEX) field campaigns will be presented, highlighting the diverse continental and marine tropical environments in which rain clouds and mesoscale convective systems evolved. An assessment of ongoing sounding quality control procedures will be shown. Additionally, we will present preliminary budgets of sensible heat source (Q1) and apparent moisture sink (Q2), which have been diagnosed from the various sounding networks.

Halverson, Jeffrey B.↗

A Wolter imager on the Z machine to diagnose warm x-ray sources

A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm 3 field-of-view and measured 60-300-μm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. Here, we provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosable systems for intermittent faults

The fault diagnosis capabilities of systems composed of interconnected units capable of testing each other are studied for the case of systems with intermittent faults. A central role is played by the concept of t(i)-fault diagnosability. A system is said to be t(i)-fault diagnosable when it is such that if no more than t(i) units are intermittently faulty then a fault-free unit will never be diagnosed as faulty and the diagnosis at any time is at worst incomplete. Necessary and sufficient conditions for t(i)-fault diagnosability are proved, and bounds for t(i) are established. The conditions are in general more restrictive than those for permanent-fault diagnosability. For intermittent faults there is only one testing strategy (repetitive testing), and consequently only one type of intermittent-fault diagnosable system.

Mallela, S.↗

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short-term numerical precipitation forecasts initialized using a diagnosed divergent-wind component

Use of the diagnosed-divergence initialization procedure of Tarbell et al. (1979) to predict the hourly rainfall data used in short-term precipitation forecasts is examined experimentally. Data simulations using a mesoscale model and balanced and internally consistent data were conducted; the physical and numerical characteristics of the mesoscale model are described. The real experiment used rainfall data from April 25-26, 1979 to investigate the capabilities of the initialization procedure to improve short-term precipitation forecasts. The derivation of the diagnosed-divergent wind using a mesoscale omega equation which includes the effects of latent heating is discussed. The diagnosed-divergence initialization forecasts are compared to nondivergence or observed-divergence initializations. It is observed that the diagnosed-divergence initializations provide better rainfall data than the other initializations.

Salmon, Ellen M.↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Multiple Fault Diagnosability using Possible Conflicts

Multiple fault diagnosis is a difficult problem for dynamic systems. Due to fault masking, compensation, and relative time of fault occurrence, multiple faults can manifest in many different ways as observable fault signature sequences. This decreases diagnosability of multiple faults, and therefore leads to a loss in effectiveness of the fault isolation step. We develop a qualitative, event-based, multiple fault isolation framework, and derive several notions of multiple fault diagnosability. We show that using Possible Conflicts, a model decomposition technique that decouples faults from residuals, we can significantly improve the diagnosability of multiple faults compared to an approach using a single global model. We demonstrate these concepts and provide results using a multi-tank system as a case study.

multiple faults↗

{sup 68}Ga-PSMA-11 PET/CT in newly diagnosed prostate cancer: diagnostic sensitivity and interobserver agreement

Purpose: To determine the diagnostic sensitivity and interobserver agreement of Gallium 68-prostate-specific membrane antigen positron emission tomography/computed tomography ({sup 68}Ga-PSMA-11 PET/CT) imaging for diagnosis and staging of patients with newly diagnosed prostate cancer (PC). Materials and methods: One hundred and seventy-three men (mean age, 68 ± 7.7 years; range 46–84 years) with newly diagnosed, untreated PC were enrolled in this prospective study between January 2017 and August 2018. All patients underwent a {sup 68}Ga-PSMA-11 PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value (SUVmax) for primary prostatic tumor and extraprostatic metastases. The diagnostic sensitivity and interobserver agreement of {sup 68}Ga-PSMA-11 PET/CT for diagnosis and staging of PC were established by histopathology as the reference standard. Results: {sup 68}Ga-PSMA-11 PET/CT examinations were interpreted as positive for PC in 166 of 173 patients (101 patients had primary prostatic tumor only, two patients had extraprostatic metastases only and 63 patients had combined lesions). The sensitivity of {sup 68}Ga-PSMA-11 PET/CT examination in the diagnosis of PC was 96%. {sup 68}Ga-PSMA-11 PET/CT produced a significant change of stage in 28.6% patients with an upstage in 17.9% patients and a downstage in 10.7% patients. The interobserver agreements were almost good to perfect (k = 0.63–0.89) for visual image interpretation, SUVmax measurement, and tumor staging. Conclusion: {sup 68}Ga-PSMA-11 PET/CT is a valuable tool with high diagnostic sensitivity (96%) and high reproducibility for diagnosis and staging of patients with newly diagnosed PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical diagnoses using three-way fuzzy concept lattice and their Euclidean distance

Searching the closest symptoms of a particular disease in the given patient is a major concern for medical diagnoses expert. In most cases, this problem arises due to large number of incomplete, uncertain, or inconsistent information generated in medical diagnoses data set. Recently, some of the researchers tried to pay attention towards precise measurement of uncertainty and vagueness in medical data set using the properties of applied abstract algebra. In this process, researchers noticed that calculus of three-way decision space is more useful to characterize the uncertainty and vagueness in medical data set based on truth, indeterminacy, and falsity membership-values. However, searching some relevant query based on user requirement to diagnoses the disease is a major issue in three-way decision space. To encounter this problem, current paper tried to analyze the medical data set using the properties of single-valued neutrosophic graph-based concept lattice. In addition, another method is proposed to select some of the interesting three-way fuzzy concepts at user-defined granulation for their computed Euclidean distance with an illustrative example.

97 MATHEMATICS AND COMPUTING↗

Tick bite frequency, prevention practices and Lyme disease diagnoses among U.S. Hispanic survey respondents

Abstract Tick bite prevention practices, knowledge of Lyme disease (LD) symptoms and transmission, and patterns of LD diagnoses among Hispanic persons have been reported but not comprehensively evaluated. In 2014, CDC examined questions from a prospective nationwide survey of U.S. Hispanic adults conducted via the Offerwise QueOpinas panel regarding ticks and LD. From October to November, a total of 2,649 surveys were released and 1,006 completed surveys returned. Overall, 44% of respondents reported routinely practising at least one form of personal protection against tick bites, and wearing repellent was the most commonly reported method (29%). Approximately 6% of respondents reported a tick bite for either themselves or someone in their household during the previous 12 months. An individual or household diagnosis of LD in the previous year was reported by 2% of respondents, with the highest proportion of diagnoses reported by respondents from high LD incidence states. The annual incidence of healthcare provider‐diagnosed LD in the survey population was higher than national surveillance estimates for reported LD among U.S. Hispanic persons during 2000–2013. As annual incidence of LD continues to increase, it is important to ensure equitable access to information about LD, including disease transmission, manifestations, and prevention recommendations. Results from this survey can help inform public health outreach focused on effective tick bite prevention methods and early recognition of LD.

Beck, Alyssa↗

Practical Formal Verification of Diagnosability of Large Models via Symbolic Model Checking

This document reports on the activities carried out during a four-week visit of Roberto Cavada at the NASA Ames Research Center. The main goal was to test the practical applicability of the framework proposed, where a diagnosability problem is reduced to a Symbolic Model Checking problem. Section 2 contains a brief explanation of major techniques currently used in Symbolic Model Checking, and how these techniques can be tuned in order to obtain good performances when using Model Checking tools. Diagnosability is performed on large and structured models of real plants. Section 3 describes how these plants are modeled, and how models can be simplified to improve the performance of Symbolic Model Checkers. Section 4 reports scalability results. Three test cases are briefly presented, and several parameters and techniques have been applied on those test cases in order to produce comparison tables. Furthermore, comparison between several Model Checkers is reported. Section 5 summarizes the application of diagnosability verification to a real application. Several properties have been tested, and results have been highlighted. Finally, section 6 draws some conclusions, and outlines future lines of research.

Cavada, Roberto↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Expert Vocabulary Usage Patterns Between Mental Health and Nonmental Health Clinicians When Diagnosing Pediatric Anxiety Disorders

Objective: To compare the utilization patterns of expert vocabulary (EVo) in diagnosing pediatric anxiety between mental health and non-mental health clinical notes from electronic health records to understand the role of Evo in informing classification and decision-making in anxiety diagnoses. Study design: We conducted a retrospective study using a cohort less than age 25 from Cincinnati Children's Hospital including 897 685 patients with 61 586 446 notes. We analyzed EVo, collected from mental health clinicians, in both mental and nonmental health notes. We compared classification accuracy using EVo-based patient-level embedding from all clinical notes, mental-health notes, and nonmental health notes for 2 tasks: 1) pre-vs postdiagnosis anxiety patients, and 2) prediagnosis anxiety vs nonanxiety patients. Results: EVo usage was highest in prediagnosis anxiety, lower in nonanxiety, and lowest in post-diagnosis. Classification models using EVo features from all, mental-health, and non-mental health notes showed similar F1 scores for prediagnosis anxiety (0.70 ± 0.2 for 2 categories). For anxiety vs nonanxiety classification, all clinical and nonmental health notes had better F1 scores than mental-health notes (above 0.90 for 3 categories). There was a notable difference in class-wise performance across both tasks. Conclusions: There are significant differences in anxiety EVo use between mental health and nonmental health clinicians. Despite less anxiety-specific terminology, non-mental health notes still captured key aspects of patient presentations, emphasizing the importance of including all clinicians' notes in analysis. EVo's utility for anxiety classification is most effective in prediagnostic phases, suggesting the need for a dedicated diagnostic lexicon and further study before incorporating EVo into classification models.

feature engineering↗

Unabsorbed light beamlets for diagnosing coronal density profiles and absorption nonuniformity in direct-drive implosions on OMEGA

Laser light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. The 3ωGOI (gated optical imager) beamlets diagnostic images unabsorbed light from all 60 OMEGA beams as distinct “beamlet” spots for each beam. The implosion can be diagnosed using the position and intensity of these beamlets. The position of each beamlet in the image is determined by refraction and can be used to fit the coronal plasma density profile of the implosion. The inferred plasma density profiles are comparable to profiles predicted by the 1-D hydrodynamics code LILAC but suggest the predictions underestimate the density farther out in the corona. The intensity of light in each spot depends on the cumulative effects of absorption and cross-beam energy transfer along the beamlet’s path through the corona. Furthermore, the measured variation in intensity and polarization between similar spots indicates that absorption during OMEGA implosions is less uniform than previously known.

47 OTHER INSTRUMENTATION↗

Diagnosing low-mode (ℓ < 6) and mid-mode (6 ≤ ℓ ≤ 60) asymmetries in the post-stagnation phase of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA

Low- and mid-mode perturbations are possible candidates for performance limitations in cryogenic direct-drive implosions on the OMEGA laser at the Laboratory of Laser Energetics. Simulations with a 3D hydrocode demonstrated that hotspot imagers do not show evidence of the shell breakup in the dense fuel. However, these same simulations revealed that the low- and mid-mode perturbations in the dense fuel could be diagnosed more easily in the post-stagnation phase of the implosion by analyzing the peak in the x-ray emission limb at the coronal–fuel interface than before or at the stagnation phase. In experiments, the asymmetries are inferred from gated images of the x-ray emission of the implosion by using a 16-pinhole array imager filtered to record x-ray energies >800 eV and an x-ray framing camera with 40-ps time integration and 20-μm spatial resolution. Furthermore, a modal analysis is applied to the spatial distribution of the x-ray emission from deuterium and tritium cryogenic implosions on OMEGA recorded after the bang time to diagnose the low- and mid-mode asymmetries, and to study the effect that the beam-to-target ratio (Rb/Rt) has on the shell integrity.

47 OTHER INSTRUMENTATION↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗